Military Engineer Services Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Electrical and Electronics
Coronavirus COVID 19
Eprocure
Opening Date27 Aug 2019
Closing Date17 Sep 2019
Tender Amount₹ 30,00,000 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 60,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_272640_2Bid Award Id
ViewTender No
GE SGNR/ DSSC /TOK-28 OF 2019-20Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in soft/loose soil complete all as specified and directed by Engineer-in-Charge
500
-
10
... More
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level n.exc 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
100
-
10
... More
Dismantling insulators of any type and make including clamps from poles complete all as specified and directed by Engineer-in-Charge.
60
-
10
... More
Dismantling and taking down cross arm of MS channel or angle section etc complete all as specified and directed by Engineer-in-Charge.
2
-
10
... More
Dismantling and taking down ACSR conductor of any size complete all as specified and directed by Engineer-in-Charge.
2
-
10
... More
Dismantling of stay assembly complete all as specified and directed by Engineer-in-Charge
2
-
10
... More
Dismantling and taking out of GI tubing 50 mm bore from trenches/ floors/ walls/poles etc complete all as specified and directed by Engineer-in-Charge.
30
-
10
... More
Dismantling and taking out of GI tubing 80 mm bore from trenches/ floors/ walls/poles etc complete all as specified and directed by Engineer-in-Charge.
30
-
10
... More
Supplying, laying, jointing, testing and commissioning in replacement 10 sq mm, 2 core, XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/ paths/ drain/ culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
800
-
10
... More
Supplying, laying, jointing, testing and commissioning in replacement 16 sq mm, 4 core, XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/ paths/ drain/ culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
1000
-
10
... More
Supplying, laying, jointing, testing and commissioning in replacement 25 sq mm, 4 core, XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
1200
-
10
... More
Supplying, laying, jointing, testing and commissioning in replacement 50 sq mm, 3.5 core, XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
350
-
10
... More
Supplying, laying, jointing, testing and commissioning in replacement 70 sq mm, 3.5 core, XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
350
-
10
... More
Supplying, laying, jointing, testing and commissioning in replacement 95 sq mm, 3.5 core, XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
250
-
-
... More
Supplying, laying, jointing, testing and commissioning in replacement 120 sq mm, 3.5 core, XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
200
-
10
... More
Supplying, laying, jointing, testing and commissioning in replacement 150 sq mm, 3.5 core, XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
100
-
10
... More
M & L for sand cushioning with dry coarse canal sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge.
Note : Thickness after punning shall be considered for payment.
208
-
-
... More
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
9000
-
-
... More
Laying only, sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Note:- Serviceable bricks obtained from srl item No '1&2' shall be reused.
2000
-
-
... More
S&F cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size including applying two coats of aluminum paint over a coat of red oxide primer on exposed steel surface and applying one coat of red oxide primer on unexposed steel surface complete all as specified and directed by Engineer-in-Charge.
2
-
10
... More
S&F aluminium conductor steel reinforced (ACSR) of any size fixed on HT/LT poles fixed on insulators and binding with & including binding wire 14 SWG complete all as specified and directed by Engineer-in-Charge. Note : The weight of binding wire shall not be considered for payment.
2
-
-
... More
S&F shackle type insulators, vitreous porcelain white, brown or green for working pressure 1100 volts grade of 100 mm height and 115 mm dia including galvanized mild steel straps of 31mm x 5mm size,14mm dia insulator bolts, washers and nuts complete all as specified and directed by Engineer-in-Charge.
60
-
-
... More
S&F stay assembly complete with accessories as shown in electrical plate No 1 using stay rod 20 mm dia x 1.8 metre long, stay bow 14mm dia and stay plate 30 cm x 30 cm x 6 mm including stay wire 8 SWG x 7 strands, loop type insulator, stay clampswith and including painting to exposed surfaces of mild steel work with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
Note : Excavation, earthwork and PCC in foundation shall be measured and paid seperately under respective items of BOQ.
2
-
-
... More
S&F GI pipe 80 mm bore light grade for protection of cable including provision of clamps, nuts, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-Charge.
NOTE: (i) Cost of Clamps & nuts/ bolts required for fixing included in the quoted rate of item. (ii) Excavation & earth work shall be measured and paid separately under respective items of BOQ
30
-
-
... More
S&F GI pipe 50 mm bore light grade for protection of cable including provision of clamps, nuts, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-Charge.
NOTE: (i) Cost of Clamps & nuts/ bolts required for fixing included in the quoted rate of item. (ii) Excavation & earth work shall be measured and paid separately under respective items of BOQ
30
-
-
... More
M&L for in replacement Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth of not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm bore. by means of bolts, nuts and washers of the earth wire galvanized iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanized iron pipe light grade 40mm dia. up to earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm bore. GI medium grade of length 2.25 meter and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 6mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Complete all as specified and directed by Engineer-in-Charge.
Notes: - (i) GI strip up to earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 meter away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement shall be 1 kg for each earth pit cover
6
-
10
... More
M&L for in replacement earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanized iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanized iron pipe light grade 40mm bore. up to earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm bore. GI medium grade of length 2.25 meter and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 6mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Complete all as specified and directed by Engineer-in-Charge.
Notes: - (i) GI strip up to earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 meter away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement shall be 1 kg for each earth pit cover
25
-
10
... More
S&F in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other situation for loop earthing etc as required using 32x6mm galvanized iron strip complete all as specified and directed by Engineer-in-Charge.
50
-
10
... More
Supplying and erecting in replacement 9 meter long ,type 410 SP- 31 steel tubular swaged pole in true vertical position complete with cast iron base plate, finial taper plug, bolts nuts and screws including painting with two coat of synthetic enamel paint black and white in alternate strips 30cm each up to 1.5 meter height from top of PCC coping and remaining portion of pole shall be painted with two coats of aluminum paint including writing pole No. with black synthetic enamel paint over 15 cm dia. yellow round base prepared with synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. NOTE: - Excavation, earth work and concrete work for embedding poles shall be measured and paid separately.
8
-
10
... More
S&F in replacement new generation energy saving & environmental friendly long life versatile pressure die-cast aluminum IP-66 road way luminaries 45 watt LED with high power LEDs as light source and electronic driver including testing complete all as specified and directed by Engineer-in-Charge. Makes: - CG Cat part No LSTP-45-CDL or equivalent in any of the Make mentioned in list of product.
25
-
10
... More
S&F in replacement ,continuous earth wire/guard cradle hexagonal rectangular, fabricated out of 4 mm dia galvanized steel wire including mild steel wire of 1.63mm dia complete all as specified and directed by Engineer-in-Charge.
1
-
10
... More
S&F in replacement on pole / wall /in panel , Sheet metal enclosure Bus bar chamber consisting 4 pole 400 Amp 415 volts ,copper bus bar suitable for connecting cable as a junction including connecting of existing cables with suitable sizes aluminum thimbles complete all as specified & directed by Engineer-in-Charge.
1
-
10
... More
S&F in replacement on pole / wall /in panel , Sheet metal enclosure Bus bar chamber consisting 4 pole 200 Amp 415 volts ,copper bus bar suitable for connecting cable as a junction including connecting of existing cables with suitable sizes aluminum thimbles complete all as specified & directed by Engineer-in-Charge.
1
-
10
... More
S&F in replacement on pole / wall /in panel , Sheet metal enclosure Bus bar chamber consisting 4 pole 100 Amp 415 volts ,copper bus bar suitable for connecting cable as a junction including connecting of existing cables with suitable sizes aluminum thimbles complete all as specified & directed by Engineer-in-Charge.
4
-
10
... More
S&F in replacement on pole / wall /in panel ,Sheet metal enclosure Bus bar chamber consisting 3 pole 32 Amp 415 volts ,copper bus bar suitable for connecting cable as a junction complete all as specified & directed by Engineer-in-Charge.
5
-
10
... More
S&F in replacement Hot moulded (FRP) junction box of size 240mm x 160130mm x 110 mm for street light pole with locking arrangement with 32 Amps, 4 way heavy duty terminal block suitable connection for three phase incoming cable three phase outgoing cable and single phase connection for light fittings with control MCB SP 2.5 Amps 01 Nos enclosed in thermoplastic box in closed shock proof safe IP 65, weather, vermin proof, dust and water proof complete with two number cable entry gland of standard size with suitable size mild steel clamps of size 25x3mm with nut and bolt to fix on pole complete all as specified and directed by Engineer-in-Charge. Make : Sintex cat No: GS-JB-2817 / Indo Asian / Havells
5
-
10
... More
S&F in replacement MCCB 400 Amp, four pole, 415 Volts with adjustable thermal and adjustable magnetic setting with breaking capacity not less than 35 KA complete all as specified & directed by Engineer-in-Charge.
2
-
10
... More
S&F in replacement MCCB 315 Amp, four pole, 415 Volts with adjustable thermal and adjustable magnetic setting with breaking capacity not less than 35 KA complete all as specified & directed by Engineer-in-Charge.
2
-
10
... More
S&F in replacement MCCB 250 Amp, four poles, 415 Volts with adjustable thermal and adjustable magnetic setting with breaking capacity not less than 25 KA complete all as specified & directed by Engineer-in-Charge.
5
-
10
... More
S&F in replacement MCCB 200 Amp, four pole, 415 Volts with fixed thermal magnetic setting with breaking capacity not less than 36 KA complete all as specified & directed by Engineer-in-Charge.
8
-
10
... More
S&F in replacement MCCB 100 Amp, four pole, 415 Volts with fixed thermal magnetic setting with breaking capacity not less than 16 KA complete all as specified & directed by Engineer-in-Charge.
16
-
10
... More
S&F in replacement MCCB 63 Amp, four pole, 415 Volts with fixed thermal magnetic setting with breaking capacity not less than 16 KA complete all as specified & directed by Engineer-in-Charge.
6
-
-
... More
S&F in replacement sheet metal enclousure double door, made out of CRCA mild steel sheet with insulated material like polyster with epoxy powder coated surface mounting VTPN 4 way 415 volt 200 Amp capacity bus bar, stove enameled dust and vermin proof IP:43 protection suitable for incorporation FP MCCB(V-Tech) N3 frame upto 200Amp isolator and including connection with wireand cable etc complete all as specified and directed by Engr in charge. Make: Indoasian/schneider/Havells
6
-
10
... More
S&F in replacement street light timer switch i.e. nature switch, which works on the basis of measurement of lux level of infra red rays along with enclosure box having dust and termite proof, outdoor type mounted on electric panel or on pole single phase with contactor, MCB rating 32 Amps with load bearing capacity of 6 KW complete all as specified and directed by Engineer-in-Charge.
Make - Indo Asian Cat part No TL032ASO/ Havells Cat part No. IHXTSS01060A /Sandeep Cat part No. 02ES5KWIP
2
-
10
... More
Supplying, jointing and testing in replacement straight through joints suitable for PVC cable 16 Sq mm 4 core including making connections complete all as specified and directed by Engineer-in-Charge.
5
-
-
... More
Supplying, jointing and testing in replacement cable jointing kit for 11KV (earthed) straight through suitable for XLPE cable 50 Sq mm 3.5 core including making connections complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Supplying, jointing and testing in replacement cable jointing kit for 11KV (earthed) straight through suitable for XLPE cable 70 Sq mm 3.5 core including making connections complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Supplying, jointing and testing in replacement cable jointing kit for 11KV (earthed) straight through suitable for XLPE cable 95 Sq mm 3.5 core including making connections complete all as specified and directed by Engineer-in-Charge.
3
-
10
... More
S&F in replacement air break gang operated switch, triple pole, 11 KV (outdoor type) mechanically operated, suitable for vertical mounting fixed type complete with 3 Nos silicon rubber polymeric insulators and steel frame, with operating mechanism worked from ground level with fixed contacts of phosphorous bronze and moving control of copper, for current rating upto 400 Amps including GI pipe heavy duty of required size and with locking arrangement including Godrej (Freedom) 65mm pad lock with two keys with fuse mounts, fuse carriers and HT fuse elements having 400 amp rating conforming to CPRI approval and IEC 61109 suitable for HT 11 KV, 50 Hz, AC supply including necessary electric connections, mild steel ISMC-75 of required length fixed with mild steel clamps made out of 50mm x 6 mm flat iron,nut,bolts and washers of required size for fixing GOD complete and painting structural steel with 2 coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces, complete (Set of three)complete all as specified and directed by Engineer-in-Charge. Make - Jaipuria/oblum/pactil
1
-
-
... More
Supply, installation, testing and commissioning in replacement, LT feeder pillar boxduly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of CRCA sheet 3.0 mm thick (outdoor type) machine pressed CPRI approved suitable for 440 Volt AC, 50 Hz, 3 phase, 4 wire having insulated aluminum bus bar 200 Amps,4 strip from pole with open able double shutter on both sides (rear and front side) with locking arrangement duly pre-wired with suitable size of copper conductor cable of suitable size fitted with proper size copper lugs/thimbles and connecting the incoming and outgoing MCCBs with suitable size copper strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including bottom frame and legs made out of angle iron 50mm x 50mm x 6mm and 600mm long 4 legs grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete with the following:-
Incoming (a)MCCB 400 Amps, four pole,35 KA with fixed thermal magnetic release-01Nos Outgoing (b)MCCB 100 Amps four pole, 25 KA with fixed thermal magnetic release-05Nos
(c) Digital volt meter 0-500 volts analog type with selector switch -01 No
(d) Digital Ammeter 0-500 volts with selector switch and CT's of appropriate size - 01 No
(e) Phase indicating lamp LED type R-Y- B -01 set of three
Makes:-ADHUNIK SWITCHGEARS PVT LTD/C & S/GEC/HAVELLS INDIA LTD./INDO- ASIAN/LARSEN & TUBRO (L&T)/POWERTECH SWITCHGEARS (I) PVT LTD (POWERTECH)/SUPERTECH POWER CONTROL PVT LTD/GEC
1
-
-
... More
Supply, installation, testing and commissioning in replacement, LT feeder pillar box in replacement duly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of CRCA sheet 3.0 mm thick (outdoor type) machine pressed CPRI approved suitable for 440 Volt AC, 50 Hz, 3 phase, 4 wire having insulated aluminum bus bar 400 Amps,4 strip from pole with open able double shutter on both sides (rear and front side) with locking arrangement duly pre-wired with suitable size of copper conductor cable of suitable size fitted with proper size copper lugs/thimbles and connecting the incoming and outgoing MCCBs with suitable size copper strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including bottom frame and legs made out of angle iron 50mm x 50mm x 6mm and 600mm long 4 legs grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete with the following:- Incoming (a)MCCB 400 Amps, four pole,35 KA with fixed thermal magnetic release- 01 No Outgoing (b) MCCB 320 Amps four pole, 25 KA with fixed thermal magnetic release - 01 Nos
(c) MCCB 100 Amps four pole, 25 KA with fixed thermal magnetic release- 01 No
(c) Digital volt meter 0-500 volts analog type with selector switch -01 No
(d) Digital Ammeter 0-500 volts with selector switch and CT's of appropriate size - 01 No
(e) Phase indicating lamp LED type R-Y- B -01 set of three
Makes:-ADHUNIK SWITCHGEARS PVT LTD/C & S/GEC/HAVELLS INDIA LTD./INDO- ASIAN/LARSEN & TUBRO (L&T)/POWERTECH SWITCHGEARS (I) PVT LTD (POWERTECH)/SUPERTECH POWER CONTROL PVT LTD/GEC
1
-
-
... More
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, stays & mass concrete complete all as specified and directed by Engineer-in-charge
5
-
-
... More
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in pedestal coping of poles etc including weathering, slightly rounded or chamfered angle and necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
2
-
-
... More
M & L for cutting road /plinth /hard standing for laying of pipe for passing cable through road without damaging Road / Plinth /Floor including making good with bitumen ready mix material as per existing specifications complete all as specified and directed by Engineer-in-Charge.
10
-
10
... More
M&L for opening the joints of HT / LT overhead conductor ( 2 conductor up to 8 nos of conductor ) from the end of poles, re-stretching the overhead aluminum conductor with chain pulley and other T&P machineries, refixing the overhead conductor at the same place so that sagging of conductor is not more than 3% complete all as specified and directed by Engineer-in-Charge. Note: 2 to 8 nos of conductors between 2 poles shall be measured as each span
250
-
10
... More
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT/HT overhead lines with hack saw/axe to clear the LT/HT line upto 3 metre on each side (Horizontal and / or vertical) including disposal of trimmed branches 2 KM away inside the Military station area & clearing site complete all as specified and directed by Engineer-in-Charge. Note :- 3 metre width on each side of LT/HT line shall be cleared and each span having not less than 3/5 conductors and min30-40 m pole to pole distance shall be measured as each span.
200
-
10
... More
Refixing existing surface cable( LT/XPLE/PVC cable) to undergroundof size ranging 10 Sqmm 2 core to 16 Sqmm 4 core including disconnecting it and reconnecting using lugs cable and gland etc complete all as specified and directed by the Engineer-in-Charge
Note Excavation, earth work, and protective work shall be measured and paid separately under respective items of BOQ
250
-
10
... More
Refixing existing surface cable ( LT/XPLE/PVC cable) to underground of size ranging 25 Sqmm 3.5 core to 120 Sqmm 3.5 core including disconnecting it and reconnecting using lugs cable and gland complete all as specified and directed by the Engineer-in-Charge
Note Excavation, earth work, and protective work shall be measured and paid separately under respective items of BOQ
250
-
10
... More
M&L for preparation of old plastered or unplastered surface of walls by brooming down or steel wire brushing,scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of white wash complete all as specified & directed by Engineer-in-Charge.
300
-
100