Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 89,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MES_555184_1Bid Award Id
ViewTender No
GE (N) BKN TOKEN NO 55 /2022-2023Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L for point wiring with and including single core FRLSH PVC insulated and unsheathed stranded copper conductor cable of size 1.5 sqmm 1100 volts grade drawn through and including suitable size of PVC concealed conduit with accessories with laminated top cover fixed on MS sunken box for housing of switch, socket, regulator etc complete with and including 1.5 sqmm FRLSH PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling ,including distemper paint,etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge for the following
(a) One Light/fan/ex-fan/Bell point controlled by one switch.
290
-
-
(b)One pin 5 amps socket point on the same board with other switches complete
84
-
-
(c) One 3 pin 5 amps socket on independent board.
116
-
-
all as per item No 4 above but with 4 sqmm copper wire for 3 pin socket outlet 15 Amp on independent board complete and all as directed by Engr-in-charge.
72
-
-
all as per item No 4 above but but one light point controlled by two 02 way switch board complete and all as directed by Engr-in-charge.
2
-
-
S&F switch Modular type, 6 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge.
405
-
-
S&F switch Modular type, 16 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge.
64
-
-
M&L socket outlet 3 Pin 6 Amps modular type, 2/3 pin combined 2 module 230 Volts complete all as specified and directed by Engr-in-Charge.
200
-
-
M&L socket outlet 3 Pin 6/16 Amps modular type, 2/3 pin combined 2 module 230 Volts complete all as specified and directed by Engr-in-Charge.
57
-
-
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed by engineer-in-charge.
15
-
-
supply and fixing Bell push, flush type, 5 amp 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge.
12
-
-
supply and fixing Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed by Engr-In-Charge.
12
-
-
S&F ceiling rose, surface backelite , three terminal AC, 230 volt complete all as specified.
254
-
-
supply and fixing fan step regulator modular type,120W -2 module electronic socket type five step controlled 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge.
42
-
-
Supply and fixing LED mirror light fitting , type with high out put diffuser 2 feet, 5watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.HAVELLS CAT PART NO-ENDURALINEARNEOBS10WLED865SPCWH/WIPRO CAT PART NO-LL20-111-XXX-65NE3/BCLSB 10 WH
12
-
-
Removing and Refixing LED tube light fitting, 1x 20-22 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge.
127
-
-
Removing & Refixing LED bulk head ,09W / 10 W, IP65 diacast aluminium housing powder coating finished 0.9 complete all as specified and directed by Engineer-in-charge. Cat Part no. SSk-BH-9W in make Syska / havell's / Phillips.
20
-
-
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings
42
-
-
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
12
-
-
S&F MCB TPN 40-63 amp, 4 pole, 415 volts, fixed type breaking capacity 10KA complete all as specified and as directed by Engr-in-charge.
2
-
-
S&F sheet metal enclosure MCB DB, double door, Vertical TPN 8 way with 200 Amps rated busbar all as specified and as directed. Make:- Hegar/Legrand/Seimens
1
-
-
Supply and fix in replacement of MCB DB SPN 8 Way with metal double door, (IP43 Protection) flush mounting epoxy powder control having 200 nos rated bus bar complete all as specified and directed by Engr-in-Charge.
18
-
-
S & F MCB SPN, 5-32 Amps, 240 volts, breaking capacity 16KA complete all as specified and as dircted by Engr-in-charge.
28
-
-
S & F MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA 'C' Curve complete all as specified and as dircted by Engr-in-charge.
108
-
-
S&F sheet metal enclosure MCB DB, double door, TPN 4 way with 200 Amps rated busbar all as specified and as directed. Make:- Hegar/Legrand/Seimens
4
-
-
S&F MCB 100 amps, 4 pole, 415 volts, fixed type breaking capacity 16KA complete all as specified and as directed by Engr-in-charge.
2
-
-
M & L for submain (single phase) wiring complete with and including 6.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through CONCLED PVC conduit of suitable size including accessories and fixed on walls and 6 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 6.0 sqmm PVC insulated wire and one run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit length.and making good to the disturbed surfaces of wall, floor, ceiling ,including distemper paint,etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge
400
-
-
Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as directed by Engineer-In-Charge.
26
-
-
Taking down Exhaust fan,sealing cable end,dismantling blades and removing fan and blades & refixing Exhaust fan of any make, any sweep , keeping side in store in safe custody for painting of Exhaust fan complete,in situ with synthetic enamel paint byspraying including filling cavities with filler,one coat after cleaning all dust and reassembling the fan complete including writing MES No at the site.
3
-
-
Taking down Geyser of any capacity from wall complete all as specified and directed by Engineer-in-Charge.
2
-
-
Refixing of geyser with including fixing arrangement complete all as specified and directed by engineer-in-charge
2
-
-
S&F GI bracket made out of 40 mm bore GI pipe light grade /medume grade, ISI marked, medium grade 1.2m long bent to shape suitable for fixing of street light fitting including with 2 Nos MS clamps made with 40x3mm flat iron, bolts, nuts, washers etc including two coats of synthetic enamel paint over one coat of zinc chrome primer and fixing on electric pole complete all as specified and as directed by Engr-in-charge.
12
-
-
Supply & fix LED Wall light 12W, sun / prismatic made up of unbreakable poly carbonate suitable for mounting on wall/ surface omplete all as specified and directed by Engineer-in-charge.MAKE-SURYA Cat Part no. SLEWE 12W -GP200
8
-
-
Supply and laying Sand coarse dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness all complete as specified and as directed.
8
-
-
Supply and laying bricks (old size) for cable protection by using common burnt clay building bricks, sub-class ‘B’ designation 75 laid dry flat across length of the cable with width of the trenches equal to length of bricks and all as directed.
0.73
-
-
S&F GI tubing light grade 40mm dia for protection of cable on pole/ wall etc complete all as specified and as directed by Engr in charge.
6
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50sq mm 3.5 core complete all as specified and directed.
80
-
-
S&F MCCB 200 amps, 4 pole, 415 volts, Adjustable type breaking capacity 36KA complete all as specified and as directed by Engr-in-charge.
1
-
-
M&L for submain wiring using 4 runs of single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 4runs of 10 Sqmm of voltage rating 1100V for three phase & neutral, drawn in and including concealed PVC conduit of dia not less than 25 mm dia with standard acessories, along with two run of FRLS PVC insulated, unsheathed, stranded copper conductor of size 2x 6.0 Sqmm as earth continuity conductor all as specified and directed(Note-4 runs of single core FRLS PVC cable 10sqmm for three phase & neutral with Two run of earth conductor as earth and conduit shall be measured as one unit)
100
-
-
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion.
6
-
-
S&F switch Modular type, 6 Amp, 1 module single pole two way, 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge.
4
-
-
M & L white metal shade study lamp white base complete with led bulb 7watt
8
-
-
S & F MCB DP,D CURVE 40 Amps , 240 volts, complete all as specified and as dircted by Engr-in-charge.
8
-
-
S&F MCCB 63amps, 16KA 4POLE, 415 volts, complete all as specified and as directed by Engr-in-charge.
2
-
-
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m
8
-
-
Taking down fan,sealing cable end,dismantling blades and removing fan and blades & refixing ceiling fan of any make, any sweep , keeping side in store in safe custody for painting of ceiling fan complete,in situ with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust and reassembling the fan complete including writing MES No at the site.
16
-
-
Supply, installation, testing and commissioning desert cooler (overall minimum size 26"x26"x39") made out of 18 gauge galvanised sheet, depth of water tank shall be 11" ( min), electric driven,230 volt ,single phase, 50 Hz supply having nominal air existing platform /stand including provision of PVC connection heavy duty 750 mm long with brass union at both end for necessary water connection, Desert cooler comprising of the following:- (a) Float valve of size 15mm shall be deemed to be inclusive with cost of desert cooler.
(b) Cooler fan motor, 145 watt, 1400 RPM, single phase, 500 mm sweep, aluminium blades Make :- Crompton Greeves Ltd/Khaitan/Cool home with standerd clamps fixing to body of cooler. (c) On/Off switch for pump and motor alongwith three speed selector switch for fan. (d) Submersible pump 23 watt (minimum) capacity, 220/240 volts, single phase, 50 Hz having lifting height 2 mtr of make Crompton/Bajaj as approved by GE. (e) Front adjustable grill both side i.e horizontally & vertically. (f) PVC 3-core flexible of size 4 sqmm with plug top for electric connection .
(g) Three side slotted shutter with suitable pad as per standerd practice. (h) Spray painting to external surface of cooler and anticrosive rubber paint to internal surface of water tank portion.
4
-
-
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
766
-
-
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
681
-
-
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
85
-
-
M&L for galvanized steel water tubing medium grade of 150 mm bore (ISI marked) with & including all fittings laid in trenches complete all as specified and as directed.
Note :- Excavation & earthwork shall be measured & paid for separately.
450
-
-
M&L for galvanized steel water tubing medium grade of 100 mm bore (ISI marked) with & including all fittings laid in trenches complete all as specified and as directed.
Note :- Excavation & earthwork shall be measured & paid for separately.
1900
-
-
M&L for galvanized steel water tubing medium grade of 80 mm bore (ISI marked) with & including all fittings laid in trenches complete all as specified and as directed.
Note :- Excavation & earthwork shall be measured & paid for separately.
300
-
-
M&L for galvanized steel water tubing medium grade of 50 mm bore (ISI marked) with & including all fittings laid in trenches complete all as specified and as directed.
Note :- Excavation & earthwork shall be measured & paid for separately.
40
-
-
M&L for galvanized steel water tubing medium grade of 25 mm bore (ISI marked) with & including all fittings laid in trenches complete all as specified and as directed.
Note :- Excavation & earthwork shall be measured & paid for separately.
30
-
-
Supply & fixing mild steel clamps made of flat iron 40x6mm in two halves for tapping through 40 to 150mm bore GI/CI/DI water pipe line including drilling and welding of 25mm GI socket and necessary rubber insertion, nut, bolts & washers, complete all as directed.
1
-
-
S&F 25 mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete, all as specified & directed.
2
-
-
S&F 50 mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete, all as specified & directed.
1
-
-
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 150 mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, complete all as specified & directed.
2
-
-
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 100 mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, complete all as specified & directed.
1
-
-
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 80 mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, complete all as specified & directed.
1
-
-
S&F Non Return Valve of size 150mm bore, cast iron body, as per IS 5312 (ISI marked), heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint complete all as specified and as directed.
2
-
-
S&F Cast Iron Air Release Valve with 2 air outlets 80mm bore and fixed to 80mm to 150mm bore GI pipe line complete all as specified and as directed.
3
-
-
Supply, installation, commissioning & testing electric driven centrifugal pump set horizontal split casing pumps, CI body, stainless steel shaft and bronze impeller with suitable size of 20 HP capacity induction motor, 3 Phase, 415 Volt, 1450 RPM, AC, totally fan cooled, capacity of pump to deliver 1470 LPM at 30 mtr head discharge, complete with pump with flexible tyre type coupling having suction 100mm dia & discharge 80mm dia, fixed on common base frame foundation including suitable size holding down bolts, nuts, washers, grouted in PCC (1:2:4 type B1) as per manufacturer’s recommendation with & including anti vibration pads, connecting with suitable size PVC insulated stranded copper conductor cable, complete all as specified and as directed.
1
-
-
Supply, installing, commissioning and testing factory made and tested (CPRI type test certified) LT Panel Box cubical type (KIOSK) (outdoor type) of size as per IS specifications, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, protection class IP-53, dust & vermin proof for outdoor use, made out of CRCA sheet 3.15 mm thick, powder coated inside & outside of flint grey shade (RAL-7032), machine pressed, both side opening in two halves with provision of rubber beading and locking system, including aluminium bus bar of 300 Amp capacity, TPN, 4 strip in colour code mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers for each MCCB/cubical switch shall have the independent opening, panel shall be mounted on angle iron frame and legs made from angle of size 50x50x5 mm including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size but not less than 6 sqmm with proper ferrule & cable glands, including danger notice sticker, comprising & including the following accessories complete all as specified and as directed :- (Contd…)
1
-
-
Description of serial item No. 69 contd…
(a) MCCB 100 Amp 4 Pole, 36 kA, 415 Volts, AC 50 Hz, Thermal - Magnetic release type – 01 No (Incoming). (b) MCCB 63 Amp 4 Pole, 25 kA, 415 Volts, AC 50 Hz, Thermal - Magnetic release type – 02 Nos (Outgoing). (c) MCB 32 Amp SPN, 10 kA - 01 No (Outgoing). (d) Digital Volt meter with built in selector switch (0-500) - 03 Nos.
(e) Digital Amp meter (0-100) Amp with built in selector switch including necessary CTs (set of three) - 3 Nos.
(f) Indicator Set RYB, “LED” type (set of three) -03 Sets
(g) Fully automatic star delta starter 3 Phase 415 Volt suitable for 25 HP pump set - 02 Nos.
-
-
-
Notes for serial item No. 68 :- (i) Vertical height of legs of LT panel base frame shall be not less than 45 cm from top of nearest road level / PCC floor finish. Legs shall be grouted in PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed drawings of LT Panel approved from GE before fabrication and placing the order to the approved manufacturer. (iii) The quoted rate shall deemed to include supply & provision of built in flush type locks (with 02 keys) of superior quality as directed by Engineer in Charge. (iv) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (v) Cost of MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration where required at site (the decision of GE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
-
-
-
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified.
Note :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
30
-
-
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed.
Notes :-
(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used.
(ii) For the purpose of payment, only punned thickness shall be measured.
3
-
-
M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.
0.24
-
-
S&F 10 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Volts grade submersible flat cable (ISI marked) complete all as specified and as directed.
10
-
-
Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
1
-
-
M&L for Earthing to Panels / Transformer / GOD switch / equipments etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed.
Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
4
-
-
M&L for Valve Pit of internal size 90cm x 90cm x 90cm built in brick masonry complete all as specified in Particular Specifications and as shown on drawing No. BTD-811 Sheet No. 1/2 & 2/2 including dismantling of old existing unserviceable vale pit.
1
-
-
M&L for Valve Pit of internal size 150cm x 150cm x 150cm built in brick masonry complete all as specified in Particular Specifications and as shown on drawing No. BTD-811 Sheet No. 1/2 & 2/2 including dismantling of old existing unserviceable vale pit.
2
-
-
M&L for cutting/dismantling of PCC hardstanding / WBM road with soling & premix carpet of any description for laying/repair/replacement of water supply pipe lines and disposal of debris & rubbish to a distance exc 250m but not exc 500m and making good the same with & including plain cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) complete all as specified & directed.
2
-
-
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
1
-
-
M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed.
2
-
-
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and directed.
Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
11
-
-
Supply only integral liquid water proofing compound (ISI marked).
2
-
-
M&L for preparation of newly plastered / unplastered surfaces of walls & applying three coats of white wash complete all as specified.
11
-
-
M&L for cutting of existing DI/CI/GI pipe upto 150 mm bore in position for reducing to required length for insertion of new branch, tee, collar, tail pieces, etc complete all as specified and as directed. Note :- Excavation & earth work and fittings required for job shall deemed to be included in the rate quoted for this item.
2
-
-
Evaluation Notes How It Works ?