Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 19,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686272_1Tender No
8279/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply & Fixing MCCB 400 Amps, 415 volts AC with breaking capacity 36 KA, four pole complete all as specified and directed at site
2
-
-
... More
Supply & Fixing MCCB 250 Amps, 415 volts AC with breaking capacity 36 KA, four pole complete all as specified and directed at site
3
-
-
... More
Supply & Fixing MCCB 100 Amps, 415 volts AC with breaking capacity 16 KA, four pole complete all as specified and directed at site
5
-
-
... More
Supply & Fixing MCCB 160 Amps, 415 volts AC with breaking capacity 36 KA, three pole complete all as specified and directed at site complete all as specified and directed at site
4
-
-
... More
Taking down old unserviceable LT cable, of size 10 sqmm x 2 core with aluminium lugs etc all as specified directed by Engineer In charge
200
-
-
... More
All as per ser item no 8 above here in before but size of 16 sqmm x 4 core all as specified directed by Engineer In charge
150
-
-
... More
All as per ser item no 8 above here in before but size of 25 sqmm x 3.5 core all as specified directed by Engineer In charge
300
-
-
... More
All as per ser item no 8 above here in before but size of 50 sqmm x 3.5 core all as specified directed by Engineer In charge
100
-
-
... More
All as per ser item no 8 above here in before but size of 70 sqmm x 3.5 core all as specified directed by Engineer In charge
100
-
-
... More
M&L for Laying of XLPE insulate, armoured, heavy duty electric cable, aluminium conductor, 1100 volts grade of size 10 sqmm x 2 core all as specified directed by Engineer In charge
200
-
-
... More
All as per ser item no 13 above herein before but size of cable 16 sqmm x 4 core all as specified directed by Engineer In charge
150
-
-
... More
All as per ser item no 13 above herein before but size of cable 25 sqmm x 3.5 core all as specified directed by Engineer In charge
300
-
-
... More
All as per ser item no 13 above herein before but size of cable 50 sqmm x 3.5 core all as specified directed by Engineer In charge
100
-
-
... More
All as per ser item no 13 above herein before but size of cable 70 sqmm x 3.5 core all as specified directed by Engineer In charge
100
-
-
... More
S&F Aluminium sector lugs-long barrel of size up to 25 sqmm complete all as specified and as directed by engr-in-charge
20
-
-
... More
S&F Aluminium sector lugs-long barrel of size from 25Sqmm to 50 sqmm complete all as specified and as directed by engr-in-charge
20
-
-
... More
S&F Aluminium sector lugs-long barrel of size up from 50Sqmm to 70 sqmm complete all as specified and as directed by engr-in-charge
20
-
-
... More
Excavation in trenches not exc 1.5m wide and n. exc 1.5M deep for fdn / trenches and getting out for hard/dense soil all as specified directed by Engineer In charge
186.3
-
-
... More
Removing excavated material any type n exc 50m and depositing at a level n.exc 1.5M above ground. all as specified directed by Engineer In charge
65.43
-
-
... More
Returning/filling in layers, spreading leveling, watering and well ramming in layers n.exc 25m in sof/loose soil. all as specified directed by Engineer In charge
120.87
-
-
... More
M&L for sand cushioning to PVC cable with tibba sand and punning to provide required cover all as specified directed by Engineer In charge
55.08
-
-
... More
Supply and laying Jodhpur stone patti for cable protection of lenth between 55 to 60 cm but width between 25 to 30 cm thicknes not less than 5 cm complete as per site requirement incl removing old unsv patti and direction of engineer in charge.
153
-
-
... More
M & L for Cutting, trimming and vending tree branches falling on overhead head lines( HT/LT) after arranging electrical shutdown from department or RSEB including taking all precautions while working on lines. [Note:- (i) The length of span between two poles shall be measured in which trees are falling on overhead electric conductors. (ii) Required T & P will be arranged by the contractor at his own cost all as specified directed by Engineer In charge
60
-
-
... More
Supply and fix LT 1100V pin type porcelain/ vitreous china, white, brown, or green insulator hight 100 mm, 65mm dia, 1100 V grade incl. one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete [ISI marked]. Make : BHEL, Modern. all as specified directed by Engineer In charge
20
-
-
... More
Supply and fix LT 1100V shackle type porcelain/ vitreous white, 75mm height 90mm dia incl. one galvanised mild steel spindle, washer insulator bolt & GI nut complete [ISI marked]. Make : BHEL, Modern all as specified directed by Engineer In charge
20
-
-
... More
M&L repair for prestressed cement concrete pole 9 metre long, 102mm x 172mm at top and 102mm x 279mm at bottom (or nearest higher size as approved by State Electricity Board), Class-10 conforming to IS-1678-1998, over and including marking alternate white and black strips 30 cm height (Total 5 Nos), with two coats of synthetic enamel paint over a coat of primer & Pole nos. complete all as specified & directed by Engineer-in-charge.
5
-
-
... More
M&L for PCC 1:4:8 type D-2 using 40mm grade stone aggregate in foundation of pole all as specified & directed by engr-in-charge
2.7
-
-
... More
M&L for PCC 1:3:6 type C-2 using 40mm grade stone aggregate in foundation of stay all as specified & directed by engr-in-charge
0.2
-
-
... More
M&L for PCC 1:3:6 type C-1 using 20mm grade stone aggregate for pole coping incl necessary form work & finishing concrete surface even & smooth without using extra cement all as specified & directed by engr-in-charge
0.46
-
-
... More
Supply and fix in repair stay assembly complete comprising of MS galvanized stay plate 23cm x23cmx6mm, MS galvanised stay rod 16 mm dia with nut 215 cm long, MS galvanised stay bow 40cm long with 2 Nos galvanized thimbles with and including all fittings all as specified in SSR 1991 Part I. (Excavation, PCC for foundation, loop type insulator to be measured and paid seperately) all as specified directed by Engineer In charge
1
-
-
... More
Supply and fix insulator, loop type, porcelain vitreous, white or brown with overall dimensions of 65 x 90 mm clearance of hole 16 mm all as specified directed by Engineer In charge
1
-
-
... More
M&L for galvanised stay strand 7/2.24mm size complete all as specified & directed by Engr-in-Charge
0.5
-
-
... More
Servicing of APFC panel cleaning, tightning of connections, setting programme, testing of CT'S including calibration of APFC panel and replacing unserviceable capacitors, capacitor contactor, breakers, power factor controllers, relays, MCBs/MCCBs including wiring after servicing testing panel complete all as directed and specified by Engr-in-Charge. Note: (i) Quoted rate includes replacement of damaged panel locks as per existing as per site requirement. (ii) Painting of panels with mounting stand (with two coat of paint as specified by Engr in charge ) included in quoted rate .
(iii) suitable size of lugs and cable gland for panel deemed included in quoted rate. (iv) Necessary MS sheet,Hinges and welding including coated rate.
(v) Rate includes cleaning of panel by using high speed air blower to remove dust.
(vi) Capacitors, Capacitor contactor, power factor controller measered and paid separately.
2
-
-
... More
Supply and fix APFC relay set for APFC Panel of 80/100 KVAR 8 Step capacity 415 V including CT input including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply and fix APFC relay set for APFC Panel of 80/100 KVAR 12Step capacity 415 V including CT input including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply and fixing in repairs push buttons / rotary switches as per existing complete all as specified and directed by Engineer-in-Charge
5
-
-
... More
Supply and fixing in repairs LED indication lamp R/Y/B as per sample complete all as specified and directed by Engineer-in-Charge.
6
-
-
... More
Supply and fixing in repairs current transformer with suitable CT ratio as per existing complete all as specified and directed by Engineer-in-Charge.
6
-
-
... More
Supply and fixing MCB TP 32 amps, 3 pole operating voltage, 415V, 3 Phase, 50Hz and braking apacity 10KA complete including taking down old unsv MCBs all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Supply and fixing LED Digital type Voltmeter, 415 V, 3Phase, 50Hz all as specified directed by Engineer In charge
2
-
-
... More
Supply and fixing Digital type Ammeter, 415V, 3 Phase, 50Hz all as specified directed by Engineer In charge
2
-
-
... More
Supply and fixing in repairs 3 Phase capacitor duty contactor type (MNX 12 to 50) as per existing including taking down of old unserviceable complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Supply and fixing in repairs capacitor heavy duty cylindrical type of 5 KVAR including taking down of old unserviceable complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Supply and fixing in repairs capacitor heavy duty cylindrical type of 10 KVAR including taking down of old unserviceable complete all as specified and directed by Engineer-in-Charge.
3
-
-
... More
Supply and fixing in repairs capacitor heavy duty cylindrical type of 20 KVAR including taking down of old unserviceable complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Supply and fixing in repairs capacitor heavy duty cylindrical type of 25 KVAR including taking down of old unserviceable complete all as specified and directed by Engineer-in-Charge.
3
-
-
... More
M&L of aluminium conductor steel reinforced (ACSR) on pole, stringing properly on insulators and binding with aluminium binding wire, jumpers etc complete for any size i.e., Ferret, Weasel, Squirel of conductor. including taking down old unserviceable conductor complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
M&L cross arm , bracing support MS clamps etc including necessary fabrication, bolts, nuts, washers etc and painting with one coat of red oxide and two coats of aluminium paints including taking down old unserviceable cross arm all as directed complete all as specified directed by Engineer In charge
0.5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%