Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693843_1Tender No
CWE/HSR/ALW-55/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M & L for cutting of venturing tubes, flushing out the gas circulating system, evaporator coil & conditioning coil etc including testing and rectification of leakage & defective wiring in system including gas charging with R-12 / R-22 / R-134a/R-600 refrigerant for Window type air conditioner upto TR capacity complete all as specified and as directed.
22
-
-
... More
M & L for cutting of venturing tubes, flushing out the gas circulating system, evaporation coil & conditioning coil etc. including testing and rectification of leakage & defective wiring in system including gas charging with R-12 / R-22 / R-134a/R-600 refrigerant for Refrigerator 165/286/300/310/350 litres capacity complete all as specified and as directed.
45
-
-
... More
M & L for cutting of venturing tubes, flushing out the gas circulating system, evaporation coil & conditioning coil etc. including testing and rectification of leakage & defective wiring in system including gas charging with R-12 / R-22 / R-134a/R-600 refrigerant Deep freezer 210/320/410 litres capacity complete all as specified and as directed.
10
-
-
... More
M & L for cutting of venturing tubes, flushing out the gas circulating system, evaporation coil & conditioning coil etc. including testing and rectification of leakage & defective wiring in system including gas charging with R-12 / R-22 / R-134a/R-600 for Water cooler 40/60/80/150 litres capacity complete all as specified and as directed.
30
-
-
... More
M & L for repair for Split type air conditioner upto 2.0 TR capacity by taking out old unserviceable compressor unit and replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat, vacuumizing the system including charging with R-22/R-134a/R-410/R-600 gas, installation, testing to desired temperature complete all as specified and as directed.
28
-
-
... More
M & L for repair for Window type air conditioner upto 2.0 TR capacity by taking out old unserviceable compressor unit and replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat, vacuumizing the system including charging with R-22/R-134a/R-410/R-600 gas, installation, testing to desired temperature complete all as specified and as directed.
8
-
-
... More
M & L for repair for Refrigerator 165/286/300/310/350 litres capacity by taking out old unserviceable compressor unit and replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat, vacuumizing the system including charging with R-22/R-134a/R-410/R-600 gas, installation, testing to desired temperature complete all as specified and as directed.
14
-
-
... More
M & L for repair for Deep freezer 210/320/410 litres capacity by taking out old unserviceable compressor unit and replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat, vacuumizing the system including charging with R-22/R-134a/R-410/R-600 gas, installation, testing to desired temperature complete all as specified and as directed.
4
-
-
... More
M & L for repair for Water cooler 40/60/80/150 litres capacity by taking out old unserviceable compressor unit and replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat, vacuumizing the system including charging with R-22/R-134a/R-410/R-600 gas, installation, testing to desired temperature complete all as specified and as directed.
14
-
-
... More
S & F in repairs condenser fan motor and reconnecting the same with electrical connections for Split type AC of capacity upto 2.0 TR and testing including removing the unserviceable items complete all as specified and as directed.
24
-
-
... More
S & F in repairs condenser fan motor and reconnecting the same with electrical connections for Window type AC of capacity upto 2.0 TR and testing including removing the unserviceable items complete all as specified and as directed.
10
-
-
... More
S & F in repairs condenser fan motor and reconnecting the same with electrical connections for Refrigerator of capacity 165/286/300/310/350 litres and testing including removing the unserviceable items complete all as specified and as directed.
14
-
-
... More
S & F in repairs condenser fan motor and reconnecting the same with electrical connections for Deep freezer of capacity 10/320/410 litres and testing including removing the unserviceable items complete all as specified and as directed.
7
-
-
... More
S & F in repairs condenser fan motor and reconnecting the same with electrical connections for Water cooler of capacity 40/60/80/150 litres and testing including removing the unserviceable items complete all as specified and as directed.
14
-
-
... More
S & F in repairs condenser fan blade metallic/fibre as site requirements and reconnecting the same with electrical connections for Split type AC of capacity upto 2.0 TR including testing and removing the unserviceable item complete all as specified and as directed.
14
-
-
... More
S & F in repairs condenser fan blade metallic/fibre as site requirements and reconnecting the same with electrical connections for Window type AC of capacity upto 2.0 TR including testing and removing the unserviceable item complete all as specified and as directed.
12
-
-
... More
S & F in repairs condenser fan blade metallic/fibre as site requirements and reconnecting the same with electrical connections for Refrigerator of capacity 165/286/300/310/350 litres including testing and removing the unserviceable item complete all as specified and as directed.
14
-
-
... More
S & F in repairs condenser fan blade metallic/fibre as site requirements and reconnecting the same with electrical connections for Deep freezer of capacity 210/320/410 litres including testing and removing the unserviceable item complete all as specified and as directed.
5
-
-
... More
S & F in repairs condenser fan blade metallic/fibre as site requirements and reconnecting the same with electrical connections for Water cooler of capacity 40/60/80/150 litres including testing and removing the unserviceable item complete all as specified and as directed.
14
-
-
... More
S & F in repairs blower motor for indoor unit suitable for split type air conditioners of capacity upto 2.0 TR with capacitor of 2.5 mfd as per the existing including removing the unserviceable item complete all as specified and as directed.
18
-
-
... More
S & F in repairs blower drum for indoor unit suitable for Split Air conditioners of capacity upto 2.0 TR including removing the unserviceable item complete all as specified and as directed.
18
-
-
... More
S & F in repairs single pole contactor as per the existing size and capacity suitable for split type air conditioners of capacity upto 2.0 TR including removing the unserviceable item complete all as specified and as directed.
18
-
-
... More
S & F in repairs swing motor suitable for split type air conditioners of capacity upto 2.0 TR including testing and removing the unserviceable item complete all as directed complete all as specified and as directed.
18
-
-
... More
Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, automatic voltage stabilizer of capacity 5 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed.
10
-
-
... More
S & F in repairs copper tube of size 1/4" dia including necessary soldering, flaring and connecting the copper tube in between indoor to outdoor units of Split type air conditioners including testing and removing the unserviceable item complete all as specified and as directed.
95
-
-
... More
S & F in repairs copper tube of size 1/2" dia including necessary soldering, flaring and connecting the copper tube in between indoor to outdoor units of Split type air conditioners including testing and removing the unserviceable item complete all as specified and as directed.
95
-
-
... More
S & F in repairs sleeve foam protection suitable for split type AC of capacity upto 2.0 TR including removing the unserviceable sleeve foam complete all as specified and as directed.
20
-
-
... More
S & F in repairs factory made PVC drainpipe suitable for Split type AC of capacity upto 2.00 TR with coupler joint including removing the unserviceable drainpipe complete all as specified and as directed.
50
-
-
... More
S & F in repairs single pole sheet metal enclosure (AC Box) with a two pin and earth plug and socket complete with one single pole MCB 20/25 Amps (240V) including removing the unserviceable items complete all as specified and as directed.
20
-
-
... More
S & F in repairs metal clad plug top (AC's) suitable for (2 Pole & Earth) 20 Amps, 250 V including removing the unserviceable items complete all as specified and as directed.
15
-
-
... More
S & F in repairs metal clad socket (AC's) suitable for (2 Pole & Earth) 20 Amps, 250 V including removing the unserviceable items complete all as specified and as directed.
15
-
-
... More
Taking out unserviceable remote circuit PCB Board of Split type AC of capacity upto 2.00 TR and supply and fix new PCB board as per the existing size and capacity including testing for its working complete all as specified and as directed.
30
-
-
... More
Taking out unserviceable remote circuit PCB Board of Window type AC of capacity upto 2.00 TR and supply and fix new PCB board as per the existing size and capacity including testing for its working complete all as specified and as directed.
10
-
-
... More
Taking out unserviceable remote circuit PCB Board of 1.5/2.0/3.0 TR capacity split/ window type air conditioners and repair the same and fix to the existing AC including testing complete all as specified and as directed.
30
-
-
... More
Taking out the unserviceable relay assembly by disconnecting all the electrical connections and supply and fix new relay assembly and reconnecting the same with electrical connections for refrigerator of cap 165/286/300/310/350 litres complete all as specified and as directed.
25
-
-
... More
Taking out the unserviceable relay assembly by disconnecting all the electrical connections and supply and fix new relay assembly and reconnecting the same with electrical connections for Deep freezer of capacity 210/320/410 litres complete all as specified and as directed.
20
-
-
... More
Taking out the unserviceable relay assembly by disconnecting all the electrical connections and supply and fix new relay assembly and reconnecting the same with electrical connections for Water cooler of capacity 40/60/80/150 litres complete all as specified and as directed.
25
-
-
... More
Taking out the unserviceable overload protector of Refrigerator of capacity 165/286/300/310/350 litres by disconnecting all the electrical connections and supply and fix new overload protector and reconnecting the same with electrical connections including testing of complete all as specified and as directed.
25
-
-
... More
Taking out the unserviceable overload protector of Deep freezer of capacity 210/320/410 litres by disconnecting all the electrical connections and supply and fix new overload protector and reconnecting the same with electrical connections including testing of complete all as specified and as directed.
20
-
-
... More
Taking out the unserviceable overload protector of Water cooler of capacity 40/60/80/150 litres by disconnecting all the electrical connections and supply and fix new overload protector and reconnecting the same with electrical connections including testing of complete all as specified and as directed.
25
-
-
... More
S & F in repairs starting capacitor for compressor and reconnecting the same with electrical connections for water cooler of 40/60/80/150 litres capacity including testing and removing unserviceable item complete all as specified and as directed.
25
-
-
... More
S & F in repairs starting capacitor for compressor and reconnecting the same with electrical connections for Deep freezers of 210/320/ 410 litres capacity including testing and removing unserviceable item complete all as specified and as directed.
20
-
-
... More
S & F in repairs running capacitor for compressor and reconnecting the same with electrical connections for Split/window type AC of capacity upto 2.00 TR including testing and removing unserviceable item complete all as specified and as directed.
60
-
-
... More
S & F in repairs running capacitor for compressor and reconnecting the same with electrical connections for water cooler of capacity 40/60/ 80/150 litres, 36 mfd. including testing and removing unserviceable item complete all as specified and as directed.
40
-
-
... More
S & F in repairs running capacitor for compressor and reconnecting the same with electrical connections for Refrigerator of capacity 165/286/300/310/350 litres, 4 mfd. including testing and removing unserviceable item complete all as specified and as directed.
10
-
-
... More
S & F in repairs running capacitor for compressor and reconnecting the same with electrical connections for Deep freezers of capacity 210/ 320/410 litres, 10 mfd/36 mfd. including testing and removing unserviceable item complete all as specified and as directed.
10
-
-
... More
Taking out the unserviceable capacitor for fan motor by disconnecting the electrical connection and supply and fix capacitor for split/window type AC of capacity upto 2.00 TR, 4/6 mfd complete all as specified and as directed.
15
-
-
... More
Taking out the unserviceable thermostat switch type by disconnecting all the electrical connections and supply and fix thermostat switch including knob plate and reconnecting the same with electrical connections suitable for Water cooler of capacity 40/60/ 80/150 litres complete all as specified and as directed.
15
-
-
... More
Taking out the unserviceable thermostat switch type by disconnecting all the electrical connections and supply and fix thermostat switch including knob plate and reconnecting the same with electrical connections suitable for Refrigerator of capacity 165/286/ 300/310/350 litres complete all as specified and as directed.
15
-
-
... More
Taking out the unserviceable thermostat switch type by disconnecting all the electrical connections and supply and fix thermostat switch including knob plate and reconnecting the same with electrical connections suitable for Deep freezers of capacity 210/ 320/410 litres complete all as specified and as directed.
10
-
-
... More
S & F in repairs pin wall and reconnecting the same with electrical connections for window type AC of capacity upto 2.00 TR including testing and removing the unserviceable item complete all as specified and as directed.
15
-
-
... More
S & F in repairs pin wall and reconnecting the same with electrical connections for Refrigerator of capacity 165/286/300/ 310/350 litres including testing and removing the unserviceable item complete all as specified and as directed.
40
-
-
... More
S & F in repairs pin wall and reconnecting the same with electrical connections for Deep freezer of capacity 210/320/410 litres including testing and removing the unserviceable item complete all as specified and as directed.
20
-
-
... More
S & F in repairs pin wall and reconnecting the same with electrical connections for Water cooler of capacity 40/60/80/150 litres including testing and removing the unserviceable item complete all as specified and as directed.
25
-
-
... More
S & F in repairs drier filter and reconnecting the same with electrical connections for split/window type AC of capacity upto 2.00 TR including testing and removing the unserviceable item complete all as specified and as directed.
20
-
-
... More
S & F in repairs drier filter and reconnecting the same with electrical connections for Refrigerator of capacity 165/286/300/ 310/350 litres including testing and removing the unserviceable item complete all as specified and as directed.
25
-
-
... More
S & F in repairs drier filter and reconnecting the same with electrical connections for Deep freezer of capacity 210/320/410 litres including testing and removing the unserviceable item complete all as specified and as directed.
10
-
-
... More
S & F in repairs drier filter and reconnecting the same with electrical connections for Water cooler of capacity 40/60/80/150 litres including testing and removing the unserviceable item complete all as specified and as directed.
25
-
-
... More
S & F in repairs PVC ICE tray of refrigerator of capacities 165/286/300/310/350 litres complete all as specified and as directed.
10
-
-
... More
S & F in repairs Baffle tray of refrigerator of capacities 165/286/300/310/350 litres complete all as specified and as directed.
10
-
-
... More
S & F in repairs Crisper tray with glass of refrigerator of capacities 165/286/300/310/350 litres complete all as specified and as directed.
10
-
-
... More
S & F in repairs Defrost timer for double door refrigerator of refrigerator of capacities 165/286/300/310/350 litres complete all as specified and as directed.
10
-
-
... More
S & F in repairs Bio metal for double door refrigerator of refrigerator of capacities 165/286/300/310/350 litres complete all as specified and as directed.
10
-
-
... More
S & F in repairs Fan motor for double door refrigerator of refrigerator of capacities 165/286/300/310/350 litres complete all as specified and as directed.
8
-
-
... More
S & F in repairs Cabinet bulb (E-12/14) 15 watt medium thread type of refrigerator of capacities 165/286/300/310/350 litres complete all as specified and as directed.
8
-
-
... More
S & F in repairs PCB for refrigerator double door frost freezer of refrigerator of capacities 165/286/300/310/350 litres complete all as specified and as directed.
8
-
-
... More
S & F in repairs Door switches for refrigerator of refrigerator of capacities 165/286/300/310/350 litres complete all as specified and as directed.
5
-
-
... More
S & F in repairs Freezer chest with door in refrigerator of refrigerator of capacities 165/286/300/310/350 litres complete all as specified and as directed.
5
-
-
... More
S & F in repairs Heater for double door refrigerators of refrigerator of capacities 165/286/300/310/350 litres complete all as specified and as directed.
8
-
-
... More
S & F in repairs Self closing chromium plated water tap 15 mm bore as per site requirement for water coolers of different Make and capacity 40 litres to 150 litres complete all as specified and as directed.
25
-
-
... More
S & F in repairs Self Float valve PVC 15 mm bore with PVC ball and rod as per site requirement for water coolers of different Make and capacity 40 litres to 150 litres complete all as specified and as directed.
20
-
-
... More
S & F in repairs Starting capacitor condenser fan motor 10 mfd as per site requirement for water coolers of different Make and capacity 40 litres to 150 litres complete all as specified and as directed.
10
-
-
... More
S & F in repairs Running capacitor condenser fan motor 6 mfd as per site requirement for water coolers of different Make and capacity 40 litres to 150 litres complete all as specified and as directed.
30
-
-
... More
Shifting of Split type AC from one site to another by completely removing it from the existing place without any damage, and shifting it to new site including making holes to the existing wall made of PCC block / Stone masonry to draw cables and pipes to connect the indoor units to the outdoor units including gas charging to required level, commissioning and testing complete all as specified and as directed.
15
-
-
... More
Shifting of Window type AC from one site to another by completely removing it from the existing place without any damage, and shifting it to new site, making necessary cutting in the wall/window, making it good including gas charging to required level, commissioning and testing complete all as specified and as directed.
5
-
-
... More
S & F in repairs indoor unit suitable for split type air conditioners of 1.5 Ton capacity complete with all accessories (blower drum, blower motor, PC board etc.) as per manufacturer standard and testing including removing the unserviceable item complete all as specified and as directed.
8
-
-
... More
S & F in repairs indoor unit suitable for split type air conditioners of 2.0 Ton capacity complete with all accessories (blower drum, blower motor, PC board etc.) as per manufacturer standard and testing including removing the unserviceable item complete all as specified and as directed.
8
-
-
... More
S & F new wall mount outdoor bracket upto 36" Heavy duty MS iron stand with nuts bolts suitable for 1.5/2.0 TR split/ Window type AC, Load bearing capacity: upto 50 kg and connected works all complete all as specified and as directed.
10
-
-
... More
M & L for Removing of existing unserviceable / leakage aluminium condenser from outdoor unit of capacity split type AC of 1.5/2.0 TR capacity and S & F new copper condenser of capacity 1.5/2.0 TR as per existing installed on site, compatible with all AC's Brands in original position including fixing, brazing, cutting, respective refrigerant gas charging complete all as specified and as directed.
19
-
-
... More
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. Note - Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of casing/capping shall be measured and paid as one unit length.
100
-
-
... More
S & F in repairs brass service valve of size 1/4" suitable for split ACs of any capacity complete all as specified and as directed.
20
-
-
... More
S & F in repairs brass service valve of size 1/2" suitable for split ACs of any capacity complete all as specified and as directed.
20
-
-
... More
M & L in repairs for outdoor unit (casing) suitable for 1.5 tone split AC (without compressor). mild steel, self-standing, including condenser, suction & discharge valve, fan motor, fan blade, capillary filter, connecting copper tube and connector with connecting wiring kit complete all as specified and as directed.
7
-
-
... More
M & L in repairs for outdoor unit (casing) suitable for 2.0 tone split AC (without compressor). MS body, self-standing. including condenser, suction& discharge valve, fan motor, fan blade, capillary filter, connecting copper tube and connector with connecting wiring kit complete all as specified and as directed.
7
-
-
... More
S & F in repairs water lifting pump submersible type suitable for desert cooler complete all as specified and as directed.
400
-
-
... More
S & F in repairs desert cooler fan motor complete 20" sweep 1350 RPM, 230 Volt, 50 C/S complete all as specified and as directed.
400
-
-
... More
S & F in repairs Iron leg (Set of four) suitable for desert cooler complete all as specified and as directed.
400
-
-
... More
S & F in repairs Iron ring suitable for fan motor of desert cooler complete all as specified and as directed.
400
-
-
... More
S & F in repairs aluminium fan blade with bush powder coated for fan motor of desert cooler 20 inch sweep complete all as specified and as directed.
50
-
-
... More
S & F in repairs PVC fan blade 20 inch sweep suitable for fan motor of desert cooler including taking out of u/s fan blade of any capacity complete all as specified and directed. complete all as specified and as directed.
350
-
-
... More
S & F in repairs PVC 3-way distributors with supporting Elbow for 15 mm bore pipe complete all as specified and as directed.
200
-
-
... More
S & F in repairs wood wool pad size 30" X 3" including complete all as specified and as directed.
600
-
-
... More
S & F in repairs wood wool pad supporter of overall size 29" X 30" made of GI Strip complete all as specified and as directed.
600
-
-
... More
S & F in repairs service lead (4 meter long) PVC insulated copper conductor 3 core size 23/0.0076 with & including 6 Amp Plug top complete all as specified and as directed.
50
-
-
... More
S & F in repairs PVC pipe 15 mm bore heavy duty high density complete all as specified and as directed.
50
-
-
... More
S & F in repairs selector switch three way, 230 volts, AC complete all as specified and as directed.
50
-
-
... More
S & F in repairs switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
60
-
-
... More
S & F in repairs, side/back shutter fabric item made out of 1 mm thick galvanised iron sheet of size suitable for desert cooler of air delivery capacity 4000/5000 Cum/hour in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed.
20
-
-
... More
S & F in repairs plug top 3 pin 5/6 Amp 230 volt AC complete all as specified and as directed.
80
-
-
... More
S & F in repairs plug top 3 pin 15/16 Amp 230 volt AC, ISI marked complete all as specified and as directed.
40
-
-
... More
M & L for painting to desert cooler of any size complete after scrapping of old painted surfaces, removing the scaling etc and preparing the surfaces and painting with one coat of smoke grey synthetic enamel paint by spray painting on outer all sides of body and painting with rubber paint on inside surfaces of cooler tank and body complete all as specified and as directed.
590
-
-
... More
S & F CPVC pipes for potable hot and cold water distribution, nominal size 20 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 on walls/ ceiling or laying in floors complete all as specified and as directed.
50
-
-
... More
S & F in repairs, Front panel on which Desert cooler motor mounted on inner side and grill will be mounted on front side of panel including the empty switch box & wiring of desert cooler of any connecting capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet including gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified & directed by the Engineer-in-charge.. Quoted rates shall deemed to be included for 600 mm long PVC connection and 2 metre long 3 core 1.5 Sqmm flexible cord with 5 Amp ISI marked 3 Pin plug top complete all as specified and as directed.
50
-
-
... More
Leak testing of the AC plant with nitrogen (N2) pressure after evacuating of the existing gas from the system into empty cylinder by separating the entire system, like compressors, evaporator, condensers, cooling coil and refrigerant lines and rectifying the leakage including cutting welding brazing etc and replacing of 'O' ring, washers, gaskets etc flushing out the Nitrogen and vacuumizing, recharging the taken out refrigerant gas including testing complete all as specified and as directed to AC plants of 3 X 80 TR capacities. Note: - One complete plant shall be measured as one job, irrespective of Nos of units in that plant for the purpose of payment.
1
-
-
... More
Supply and top up refrigerant gas R-134a complete all as specified and as directed. NOTE: - Empty gas Cylinders shall be returned to contractor after use.
180
-
-
... More
Descaling of one condenser unit of 3 X 80 TR capacity AC plants of any make/type with and including descaling compound DC-98 or suitable chemical solution by using rotary type scaling cutter and brushes in stages as required to remove complete scales from all copper tubes till achieve the desired pressure including renewing of gaskets, nuts, bolts and washers etc. and testing complete all as specified and as directed. Note:- One condenser unit shall be measured as one job for the purpose of payment.
3
-
-
... More
Opening of electronic control panel board and electric panel board and other control switches in chiller AC plant of 3 x 80 TR Capacity of any make/type with technician from OEM for trouble free running of AC plant and calibration/programme reset in microprocessor control board and checking of other parameters like section/discharge pressure, oil pressure cooler entering and leaving temperature etc and including replacing minor springs, washers, bolts, nuts etc for smooth functioning of AC plant at desired temperature complete all as specified and as directed.
2
-
-
... More
Taking out the unserviceable compressor oil and refill the new compressor oil and filling oil Servo Bharat Freezol 68 complete all as specified and as directed.
120
-
-
... More
Opening of the existing Monoblock pump set and servicing by cleaning all dust, carbon including greasing for the bearing and replacement gland as well as US bearing as per existing sizes complete for the 10 HP capacities of pump sets complete all as specified and as directed.
6
-
-
... More
S & F in repairs PVC fills in cooling tower, size 600 mm X 300 mm X 150 mm, honeycomb type, made of virgin PVC, to be installed in cooling tower for central AC Plant of make as per the site requirement or as per approved complete all as specified and as directed.
50
-
-
... More
Disconnecting and taking out the existing old unserviceable water sensor and supply and fix water sensor for entering and leaving water temperature suitable for following capacities compressor of (Voltas/Carrier make) chiller type AC plant of capacity 3 X 80 TR complete all as specified and as directed.
2
-
-
... More
Servicing greasing overhauling of AHU blower motor of capacity 5.0 HP to 10.0 HP by replacing pulley, belts bearings etc complete all as specified and as directed.
2
-
-
... More
Removing the existing unserviceable cooling tower fan assembly and supply & fix new cooling tower fan assembly complete with shaft hub and including fan blade, pully and key suitable for 80 TR cooling tower and testing all as specified and directed. complete all as specified and as directed.
1
-
-
... More
Disconnecting and removing the burnt out Cooling tower/AHU/Chiller fan motor of cap 3 HP from the existing plants, rewinding of the same with supper enamelled copper conductor with same existing gauge including replacement of bearings and reconnecting the same with electrical connections and testing complete all as specified and as directed.
2
-
-
... More
Disconnecting and removing the burnt out Monoblock pumping sets of cap 10.0 HP from the existing plants of central/package type AC plant, rewinding of the same with supper enamelled copper conductor with same existing gauge including replacement of bearings and reconnecting the same with electrical connections and testing complete all as specified and as directed.
6
-
-
... More
Supply and fix in repairs pre-filter, anodised aluminium frame, filter media of non-woven Synthetic supported by aluminium expanded mesh on one side and finished with HDPE mesh on the other side, Efficiency: 99% down to 5 micron, water washable and air cleanable, size 305 mm X 610 mm X 50 mm complete all as specified and as directed. Make: Thermadyne, American air filter, Camfil air filter, Dyna Filters Pvt. Ltd.
5
-
-
... More
Supply and fix in repairs pre-filter, anodised aluminium frame, filter media of non-woven Synthetic supported by aluminium expanded mesh on one side and finished with HDPE mesh on the other side, Efficiency: 99% down to 5 micron, water washable and air cleanable, size 610 mm X 610 mm X 50 mm complete all as specified and as directed. Make: Thermadyne, American air filter, Camfil air filter, Dyna Filters Pvt. Ltd.
7
-
-
... More
S & F in repairs LP/HP cut out MP-15 components of AC plants complete all as specified and as directed.
2
-
-
... More
S & F in repairs V-Belts of A-42 sizes and testing complete all as specified and as directed.
2
-
-
... More
S & F in repairs V-Belts of B-80 sizes and testing complete all as specified and as directed.
2
-
-
... More
Material and labour for servicing of non-return valve with strainer of size 125 mm to 200 mm by suitable chemical solution including removing from installed position and refixing the same after servicing complete all as specified and as directed.
8
-
-
... More
M & L for cleaning the cooling tower of Capacity 80.00 TR by applying wire brush, washing powder and other solvent by removing the deposited impurities such as silt, dust particles mud/ sand inside the dome and around the fills/fins, wire mesh, main shaft etc. and other connected items using chemical compound based on sulphuric acid or hydrochloric acid including painting condenser lines of chiller & cooling tower structure by preparation of old painted surfaces, removing dust and other deposited materials by scrapping from cooling structure along with water lines and painting of structure with two coat of mint green paint over a coat of red oxide zinc chrome primer with synthetic enamel paint (first Grade/quality) from ground including writing 50 mm size figure/letter over blue, black on body for making data entry complete all as specified and as directed.
2
-
-
... More
Material and labour for cleaning and removal of the dust from Air Handling Unit of Cap 32.0 TR by washing with water by suitable method including cleaning of air filter complete all as specified and as directed.
2
-
-
... More
Material and labour for cleaning and removal of the dust from Ceiling Suspended AHU of Capacity 2.00 TR to 4.00 TR with suitable method including cleaning of air filter complete all as specified and as directed.
8
-
-
... More
S & F in repairs 4 pole power contactor AC, 415 V ,18-25 Amps type NO/NC built in surge, along with auxiliary contactor as per the installed / existing complete all as specified and as directed.
6
-
-
... More
Material and labour for shifting of AHU starter panel indoor type cubicle in shape totally enclosed complete with incoming MCCB/MCB & Outgoing MCB/MCCB/DOL Starter/ busbar complete all as specified and as directed.
8
-
-
... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
60
-
-
... More
S & F in repairs, top of desert cooler, of any capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet including gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed.
55
-
-
... More
S & F in repairs, front side grill of desert cooler of any capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet including gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed.
60
-
-
... More
S & F in repairs, corner of the desert cooler made out of 1 mm thick galvanised iron sheet of size suitable for desert cooler height as per the existing (up to 1.2 M) including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed.
52
-
-
... More
S & F in repairs, bottom tank of desert cooler , of any capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet with gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed.
57
-
-
... More
S & F in repairs, capacitor suitable for 4000/5000 cfm for fan motor of desert coolers complete all as specified and as directed.
69
-
-
... More
S & F in repairs Stator of inductor motor of cap 3.0 HP suitable for cooling tower of 80.0 TR Capacity complete all as specified and as directed.
1
-
-
... More
S & F in repairs Rotor of inductor motor of cap 3.0 HP suitable for cooling tower of 80.0 TR Capacity complete all as specified and as directed.
1
-
-
... More
S & F in repairs bearing of inductor motor of cap 3.0 HP suitable for cooling tower of 80.0 TR Capacity complete all as specified and as directed.
1
-
-
... More
S & F in repairs frame of inductor motor of cap 3.0 HP suitable for cooling tower of 80.0 TR Capacity complete all as specified and as directed.
1
-
-
... More
S & F in repairs Cooling fan of inductor motor of cap 3.0 HP suitable for cooling tower of 80.0 TR Capacity complete all as specified and as directed.
1
-
-
... More
S & F in repairs Stator of inductor motor of cap 7.5 HP floor mounted AHU of Capacity 36.0 TR complete all as specified and as directed.
1
-
-
... More
S & F in repairs Rotor of inductor motor of cap 7.5 HP suitable for floor mounted AHU of Capacity 36.0 TR complete all as specified and as directed.
1
-
-
... More
S & F in repairs bearing of inductor motor of cap 7.5 HP suitable for floor mounted AHU of Capacity 36.0 TR complete all as specified and as directed.
1
-
-
... More
S & F in repairs frame of inductor motor of cap 7.5 HP suitable for floor mounted AHU of Capacity 36.0 TR complete all as specified and as directed.
1
-
-
... More
S & F in repairs Cooling fan of inductor motor of cap 7.5 HP suitable for floor mounted AHU of Capacity 36.0 TR complete all as specified and as directed.
1
-
-
... More
Material and labour for servicing of water softener plant consisting of (1) Vertical FRP Dual Media Filter of (consisting of 300 mm bed depth of anthracite, filtering sand and support media and approximate dia of filter is 1000 mm) and (2) Vertical FRP Dual Media Filter(consisting of initial charge of resin) with suitable method complete all as specified and as directed.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%