Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 Jan 2025
Closing Date30 Jan 2025
Tender Amount₹ 55,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for TIBBA sand in trenches as sand cushioning to underground cable in trenches/existing cable trenches/ducts including punning down in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed. (Note :- 18 cm Punned thickness shall only be measured and paid).

202

-

-

... More
M&L for 40 to 50 mm thick rough dressed Jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cableall as specified and directed.

3100

-

-

... More
Supply and spread 40mm graded stone aggregate in the substation/ as where directed at site complete all as specified and directed.

30

-

-

... More
Supply, fix and test Cable Jointing Kit for 11 KV grade cable for outdoor termination heat shrinkable joint complete with jointing material and accessories suitable for XLPE armored aluminum cable of size 95 sqm 3 core complete all as specified and directed.

10

-

-

... More
Supply, fix and test Cable Jointing Kit for 11 KV grade cable for indoor type termination heat shrinkable joint complete with jointing material and accessories suitable for XLPE armoured aluminum cable of size 95 sqm 3 core complete all as specified and directed.

10

-

-

... More
Supply, lay, testing and commissioning of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 120 sqmm complete all as specified and directed.

15

-

-

... More
Supply, lay, joint and test Under ground XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 Volts grade (HT) earthed system of size 95 Sqmm 3 core laid in trenches, in floor, in duct, through pipesor along the pole complete all as specified and directed.

550

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of 20mm nominal bore GI light grade and lugs etc complete all as specified and directed (d) 40mm nominal bore medium grade GI protection pipe 7.5m long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.

20

-

-

... More
Repairs/overhauling to 11KV HT control Panels complete in and including the following repair works :- (a)Taking out 11KV High Tension VCBs/OCBs of 300Amps to 800 Amps rating trolley from High Tension control Panel after switching off electric supply.Checking of mechanical system for proper functioning of upward/downward movement of High Tension Vacume Circuit Breakers trolley including opening the VCB & checking the quality of vacume bottles/links , & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the VCB including connection to HT panel complete and refixing the same after repair complete all as directed. (b). Taking out existing relay set from high tension of any type and size, 11KV, VCB control panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibration the relay by giving the primary and secondry injection and checking the tripping system by relay testing kit for over current and earth fault & proper plug setting as per reqd load & time delay and fixing the relay set in High Tension control panels complete all as specified and directed by EIC .Note:- Testing of above job to be carried out by Authorized commisioning Engineer (b) spare parts to be replaced shall be measured & paid separately under the relevent items as supply only.

8

-

-

... More
Supply only Fixed contact block of VCB 630 Amps, 11 KV including taking down old material

3

-

-

... More
Supply only support insulator (75mm dia) of VCB 630 Amps, 11 KV.

3

-

-

... More
Supply only auxiliary switch (6NO + 6NC) of VCB 630 Amps, 11 KV.

3

-

-

... More
Supply only solenoid closing coil 110 v DC, suitable for type V 207G VCB 630 A VMX Breaker.

8

-

-

... More
Repairs/overhauling to 11KV HT RMUs complete in and including the following repair works :- (a) Checking & testing of Load break mechanisim and Isolator Mechanisim of 11KV High Tension RMUs of 300Amps to 800 Amps ratings after switching off electric supply.Checking of mechanical system for proper functioning of all movement of High Tension Ring main units & servicing of all moving parts & blowing out dust and applying the proper lubrication/ greasing and reassembling the RMU mechanisim after repair complete all as directed. (b). Taking out existing relay set from high tension of any type and size, 11KV, RMUs and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibration the relay by giving the primary and secondry injection and checking the tripping system by relay testing kit for over current and earth fault & proper plug setting as per reqd load & time delay and fixing the relay set in High Tension control panels complete all as specified and directed by EIC .Note:- Testing of above job to be carried out by Authorized commisioning Engineer (b) spare parts to be replaced shall be measured & paid separately under the relevent items as supply only.

6

-

-

... More
Supply only Load Break Mechanisim Assembly (2PA mechanisim without hex rod) having two position spring assisted, integrated line earthing siwtch making capacity complete all as specified of 11 KV RMUs, 11 KV Control panels as per existing complete all as specified and directed

2

-

-

... More
Supply only Isolator Mechanisim Assembly having two position spring assisted, integrated line earthing siwtch making capacity complete all as specified of 11 KV RMUs, 11 KV Control panels as per existing complete all as specified and directed

2

-

-

... More
Supply only SF 6 Gas in RMUs, SF 6 Control panels (09 Kg per cylinder) as per requirement complete all as specified and directed, Cat Part No S194-5600-103-17 of ABB or equivalent make of Schneider or crompton

2

-

-

... More
Supply only Bushing 400 series bolted type with "O' Ring, clamping nut and wave washers M 12 complete all as per existing specifred and directed

3

-

-

... More
Supply only Cable Bushing Plate as per existing complete all as specified and directed

3

-

-

... More
Supply only ON push button with Z lever complete as per existing complete all as specified and directed,

4

-

-

... More
Supply only OFF push button with Z lever complete as per existing complete all as specified and directed,

4

-

-

... More
Supply, fix and connect in replacement Announciator suitable for 11 KV indoor control panel with necessary wiring and testing on completion complete all as specified and directed.

1

-

-

... More
Supply only Shunt Trip Coil Assembly suitable for High Tension ,VCB control panels, operating on 30/110 volt system and testing complete all as specified and directed.

2

-

-

... More
Supply only Charging Motor for high tension, 11 KV, VCB panels, 400 Amps, operated on 230 volts AC or 30 Volts DC as per sample complete all as specified and directed.

1

-

-

... More
Supply only Spout HT 11 KV VCB as per sample and fixing on panel all as required at site complete all as specified and directed.

3

-

-

... More
Supply only Male Contact made of tinned copper VCB panel 11 KV made of brass as per sample and fixing testing all as required and directed at site complete all as specified and directed.

3

-

-

... More
S&F Resin/Epoxy casted air cooled high tension current transformer of dual ratio of 200-100/5 Amps, 10 VA burden out put, accuracy class - 0.5, suitable for rated voltage system of 11KV conforming to IS 2705/IEC 60044-1for metering/protection of breakers c including taking down omplete all as specified and directed.

3

-

-

... More
S&F Resin/Epoxy casted circuit spout with metallic fittings of good conductivity as specified to connect/match with the existing 11KV bus bar complete in all respect as directed. including taking down omplete all as specified and directed.

3

-

-

... More
Supply and fix in replacement, Over Current and Earth Fault Relay having auxilary voltage 24-110 volts, + 15% AC/DC complete all as specified and directed,

6

-

-

... More
Supply and fix in replacement Panel Lighting lamp with holder with on/off toggle switch complete all as specified and directed,

10

-

-

... More
Supply and fix in replacement Bakelite HRC fuses in control/VCB panels complete all as specified and directed,

15

-

-

... More
Supply and fix in replacement Power Factor Meter as per existing or as approved by the GE complete all as specified and directed,

2

-

-

... More
Supply and fix in replacement Digital Multifunctional Meter as per existing or as approved by the GE complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement Selector Switch for various type of control panels as per existing complete all as specified and directed.

5

-

-

... More
Supply and fix in replacement Indicator Lamp with holder for various control panels/ VCB panels complete all as specified and directed.

20

-

-

... More
M&L for boring hole under the road / pavement / hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting GI pipe of size 100/80 mm not less than one metre below ground level complete all as specified & directed.

30

-

-

... More
Disconnecting and taking down faulty / defective aluminium / copper wound transformer of capacity up to 750 KVA ratio 11 KV / 0. 433 or 0.415 KV from 2/4 pole structure or sub station in Jaisalmer/chandan air force stn and transporting & depositing to AGE E/M AF Jaisalmer or as directed by the Engr-in-charge complete all as specified and directed by EIC.

2

-

-

... More
Transporting of aluminium / copper wound transformer of capacity up to 750 KVA, ratio 11 KV / 0.433 or 0.415 KV from AGE E/M (AF) Jaisalmer yard to any sub station located in Jaisalmer/Chandan and connecting the same electrically and earthing complete

2

-

-

... More
Transporting faulty / defective transformer rating upto 750 KVA ratio 11 KV / 0.433 or 0.415 KV to contractor workshop from AGE E/M (AF) Jaisalmer and opening the top cover of transformer, carrying out of the followings works / repairs/maintenance and transporting back :- (a) Taking out the transformer oil from transformer into seperate container barrel. (b) Taking out the core / coil assembly of transformer. (c ) Cleaning of transformer inside by used transformer oil. (d) Re-fixing the core/coil in transformer including heating up of transformer core assembly to remove moisture after carrying out the repair as required in respective serials of Sch 'A' items. (e) Replacement the rubberised gasket set for top cover, spindles, HT / LT bushing etc. as required Note :- i) All labour costs are included in this serial. In case of replacement of LV / HV bushing / spindles / rewinding of HV / LV coils / top changer etc will be paid separately under respective serial. (ii) Filtration / centrifuging of usable transformer oil to remove moisture and suspended dust particles to be measured & paid for separately. (iii) Topping of transformer oil (if required) will paid under respective item. (f) Refilling of the removed transformer oil after heating up for removal of moisture. (g) Re-fixing of the transformer top cover with nuts, bolts and washers (h) Testing of transformer Complete.

2

-

-

... More
Repairs / reconditioning of LV leg coil aluminium / copper for transformer of capacity up 750 KVA to be done only in case where only insulation is damaged and conductor strip is intact i.e. not deformed. This work will involve valve all turns of leg coil to be reconditioned removing complete insulation from conductor strip, cleaning of conductor, wrapping of conductor with fresh DPC insulation and remaking of LV leg coils with reconditioned strip for use in transformer under repairs complete all as directed by EIC.

3

-

-

... More
Repairs / reconditioning of HV leg coil aluminium / copper for transformer of capacity upto 750 KVA including insulation, varnishing by vaccum impregnation and backing of coil assembly complete all as specified and directed by EIC.

3

-

-

... More
Supply only LV leg coil of aluminum conductor for transformer of capacity upto 750 KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly, etc. complete all as specified and directed.

30

-

-

... More
Supply only LV leg coils of copper conductor for transformer of capacity up to 750 KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly, etc complete all as specified & directed by the EIC

60

-

-

... More
Supply only HV leg coils of Aluminum conductor for transformer of capacity up to 750 KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly, complete all as specified and directed.

30

-

-

... More
Supply only HV leg coils of copper conductor for transformer of capacity up to 750 KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly, etc complete all as specified & directed by the EIC.

80

-

-

... More
Supply only HV bushing 11 KV for transformers up to capacity 750 KVA complete all as specified and directed.

6

-

-

... More
Supply only LV bushing 0.433 / 0.415 KV for transformer up to rating 750 KVA complete all as specified and directed.

8

-

-

... More
Supply only HV spindle (metal part) made out of brass with nuts and washers complete for transformer of capacity up to 750 KVA complete all as specified and directed.

6

-

-

... More
Supply only LV spindle (metal part) made out of brass with nuts and washers complete for transformer of capacity up to 750 KVA complete all as specified and directed.

8

-

-

... More
Supply, filling and topping up new transformer oil, low viscosity type of dielectric strength 35 to 40 KV breaking voltage conforming to IS complete for indoor / outdoor transformer in various sub stations under GE (AF) Jaisalmer (of capacity up to 750 KVA transformer) all as directed.

1200

-

-

... More
S&F silica gel complete suitable for up to 750 KVA transformer rating complete all as specified and directed.

5

-

-

... More
S&F silica gel breather (transparent type) with silica gel complete suitable for up to 750 KVA transformer rating all as specified and directed.

10

-

-

... More
S&F dial type thermo meter of minimum 100 mm dia with maximum temperature indicator for transformer of capacity up to 750 KVA all as specified and directed.

2

-

-

... More
M&L for centrifusing (Filteratin/dehydration of transformer oil including filter action using automatic centrifusing machine including arrnging elect supply for operation of machine to achieve min. 50 to 60 KV breaking capacity at 4 mm gap by absorbing and abolishing all sludge particles for use as per BS-B 66-1983 complete all as specified and directed.

5000

-

-

... More
Opening the top cover (in case of replacement of HT/LT spindle and bushing for arresting leakage) and taking out transformer oil as required and S&F rubberised synthetic gasket for top cover, LT terminal box, LV / HV bushings, spindles etc suitable for transformer of rating upto 750 KVA all as specified and directed. Note:- In case replacement bushing / spindle will be paid as supply only.

2

-

-

... More
Repairs to tap changer switch including replacement of unserviceable parts such as bakelite sheet, connecting rod with nuts, bolts and washers, HV lead duly taped, provision of glass sleeve of required size & length including necessary welding works for transformer of capacity upto 750 KVA complete all as specified and directed.

1

-

-

... More
Supply only Tap Changer Switch complete with handle for transformer of capacity upto 750 KVA.

1

-

-

... More
M&L for painting of Distribution transformer of capacity upto 50 KVA to 750 KVA with two coats of smoke synthetic enamel paint (colour/shed decided by GE) externally after necessary preparation to surfaces including numbering SM/MES No. with white paint, etc complete all as specified and directed.

40

-

-

... More
Taking out the old unsv HT cable after disconnecting from over head line and panel rated voltage of 11000 Volts from trenches, pole etc complete all as specified and directed

850

-

-

... More
M&L relaying of old existing cable retrived from the same after, jointing or necessary repair work and testing XLPE insulated PVC outer seathed and PVC inner sheath, galvanised steel strips armoured, and reconnecting the cable from over head line and panel suitable for rated voltage of 11000 Volts grade Earthed system of size 95/120 sqmm 3 Core and laid in treches/ducts/pipe or on read/pole all as required and directed at site. Note: excavation and earth work joints will be measured and paid seprately

300

-

-

... More
Provide the cable fault locating Machine with necessary T&P at site for locating exact pin point of fault along with the length of armourd 6.6 /11 KV XLPE/PILCA insulated HT cable complete all as required and directed at site

10

-

-

... More
Supply and fix in replacement Feeder Pillers Box (FPB) factory made -out door type made out of MS sheet (CRCA) of thickness not less that 3.15mm. of size 150x65x90cm with copper bus bar strip 3 Nos of size 130 cm in length 4 cm in width and 05mm in thickness suitable for 11000 Volts (HT) mounted on HT porcelain insulator front opening door two leaf braced with hinged, mounted on 4 Nos of angle iron 50x50 mm duly welded with box and grouted in PCC block of size 30cmx30cmx15cm in concrete (1:3:6) type C-1. Top of box MS sheet duly bent in/slope, tapper with projection of 30 mm on all side, weather/vermin proof with high quality of rubber beeding on panel door, cable entry arrangements at bottom includes earthing terminals 2 Nos at both side and painted with smoke grey stove enameled paint two coats over a primer coat all as directed.

8

-

-

... More
Supply, lay, fix, joint or pass through GI pipe/ HDPE (DWC pipe)/duct or along wall or poles including commission and test, XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 Volts grade (LT) of the following cross section area including suitable size lugs including taking out /dismantling of existing cable. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-

-

-

-

... More
(a) 10Sqmm 2 core

500

-

-

... More
(b) 10Sqmm 4 core

500

-

-

... More
(c) 16Sqmm 4 core

500

-

-

... More
(d) 25Sqmm 4 core

500

-

-

... More
(e) 35Sqmm 3.5 core

400

-

-

... More
(f) 240Sqmm 3.5 core

310

-

-

... More
S&F following galvanised steel water tubing ISI marked light grade with necessary fittings unions, tees, elbows, bends, nipples, sockets, reducers and fixtures etc including necessary cutting, threading, laid in trenches/floors, under road and ducts, fixed to walls and ceilings etc with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed.

-

-

-

... More
(a) 40mm bore

60

-

-

... More
(b) 50mm bore

50

-

-

... More
(c) 80mm bore

18

-

-

... More
(d) 100mm bore

18

-

-

... More
Taking out existing PCC/steel tubular LT electric poles of any length including breaking of cement concrete, necessary excavation and earth work, dismantling cross arms, M.S. clamps, insulators etc and carefully taking down existing over head conductors.

25

-

-

... More
Dismantling of old unservicable bus bar chamber and Design, supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947.The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth).

6

-

-

... More
Supply and erect Steel Tubular Poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410SP 31 of 9m long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emebeded portion shall be painted with two coat of black bituminous paint all as specified in IS with following specifications:- (i) Excavation in trenches in any types of soil ,returning filling in & well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (ii PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation bedding of size 600x600mm, 200mm base all as specified and directed . (iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level of size 600x600mm for casing of pole upto planting depth. (iv) PCC (1:2:4) type B-2 using 20mm graded stone aggregate as in coping including necessary form work above GL level. (v) Writing pole No with yellow shade on black base using synthetic enamel paint having height of words exc 5 cm as directed by Engr-in-charge.

25

-

-

... More
Supply and fix junction box made out of Fiber reinforced plastic with IP 55/IP 65 protection of size not less 200 x 140 x 95 mm (in side dimensions) , having 5 way terminals mounted on din rail for termination of cable with necessary nuts and bolts , including -02 Nos cable gland , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps, in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type all as directed.

35

-

-

... More
Supply and fix junction box made out of fiber reinforced plastic with IP 55/IP 65 protection of in side size not less 350 x 250 x 140 mm (In side dimensions) , having 5 way terminals suitable for 70 to 95 sqmm 3.5 core cable, mounted on din rail for termination of cable with necessary nuts and bolts , including -02 Nos cable gland , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps, in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type all as directed.

40

-

-

... More
M&L for cutting of black top cover of existing road upto 0.6 mtr depth and upto 45cm wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 upto 3-cm from top of the road surface complete all as specified and directed.

30

-

-

... More
S&F Straight through joint LT from 25 sqmm 3.5/4 core upto and including 95 sqmm 3.5 core with jointing all as required and directed at site complete all as specified and directed.

4

-

-

... More
S&F Straight through joint LT cable 120 sqmm 3.5 core to 300 sqmm 3.5 core with jointing all as required and directed at site complete all as specified and directed.

4

-

-

... More
Supply, fix and connect Elastomer insulated, flat,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 complete all as specified and directed

400

-

-

... More
Preperation of surface of RCC LT/HT poles and painting with one coat synthetic enamel paint upto 1.5m height in blue and white colour alternate strips each of 30cm wide all as specified.

300

-

-

... More
Material and labour for painting to steel tubular pole/Rail Pole, swan neck pole of HT/ LT (7.5 mtr to 13 mtr height) over head line and all MS clamps, cross arm work on poles with one coat of superior aluminium paint including necessary preparation of surfaces and painting of alternate strip with white and blue for LT and HT poles, synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/coping complete all as specified and directed.

200

-

-

... More
Material and labour for painting to two pole structure made up using steel tubular pole/Rail Pole, of HT/ LT over head line and all MS clamps, cross arm work on poles with one coat of superior aluminium paint including necessary preparation of surfaces and painting of alternate strip with white and blue for LT and HT poles, synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/coping complete all as specified and directed.

5

-

-

... More
Material and labour for painting to four pole structure made up using steel tubular pole/Rail Pole, of HT/ LT over head line and all MS clamps, cross arm work on poles with one coat of superior aluminium paint including necessary preparation of surfaces and painting of alternate strip with white and blue for LT and HT poles, synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/coping complete all as specified and directed.

1

-

-

... More
Material and labour for painting to all iron work of two pole structure made up using PCC poles of any length, painting shall be carried out to complete iron work like channels, clamps, GODO base frame and operating pipe with handle, GI pipes for cables fixed along two pole structures, clamps of stay assembly connected to PCC Poles of HT/ LT over head lines with two coats of superior aluminium paint including necessary preparation of steel surface and painting of alternate strip with white and blue for LT and HT poles, synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/coping complete all as specified and directed.

4

-

-

... More
Material and labour for painting to all iron work of four pole structure made up using PCC poles of any length, painting shall be carried out to complete iron work like channels, clamps, GODO base frame and operating pipe with handle, GI pipes for cables fixed along two pole structures, clamps of stay assembly connected to PCC Poles of HT/ LT over head lines with two coats of superior aluminium paint including necessary preparation of steel surface and painting of alternate strip with white and blue for LT and HT poles, synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/coping complete all as specified and directed.

15

-

-

... More
Material and labour for painting of 33 KV Gantry yard complete having 50 Nos of standing/supporting chanels/ H-Bean, joist etc, angle iron, nuts & bolts, clamps, strips etc and complete connected iron work, post & flat iron strip and 03 Nos VCB iron stand complete with aluminium paint and marking of white and blue strips alternatively having 30cm wide upto 1.5 mtr length on each supporting channel/Standing channels with synthetic enamel paint all as specified and directed.

1

-

-

... More
Scrubbing of existing paints of existing LT panel board where rusted, LT feeder Pillar boxes, LT bus bar chamber paints of any specification and removing old paints and preparation of surfaces for painting complete and M&L for painting of LT Panels, LT Feeder pillar boxes, LT bus bar chambers internaly and externaly with one coat of superior quality smoke grey paint to achieve fine finishing complete all as specified and directed.

30

-

-

... More
Dismantling of old unserviceable doors, back sheets, side sheet of LT panels, bus bar chamber or feeder pillar box installed at various places by cutting/descrewing after making the system disconnected from Elect supply and M&L for fabrication of doors/frames/ partition, bottom sheet by bending hot or cold, making holes, notching, welding of MS black sheet for LT panel board, bus bar chamber, feeder pillar box made out of 2 mm thick mild steel sheet including providing hinges for opening or closing of door, making handles, locking arrangement and painting of sheet both side with superior quality smoke grey paint after applying a coat of red oxide and matching with the existing ( Complete LT apnel/ Bus bar chamber shall be painted ) complete all as specified and directed by the Engr - in-charge at site. Note : 1. The cost of disconnecting of LT cable and earth strip and reconnecting the same after repair work shall be deemed to be inclussive in the unit quoted rates. 2 Painting of complete LT Pannel/Bus bar chamber shall be carried out , nothing shall be payable extra in this regard.

15

-

-

... More
S&F in replacement Aluminium Bus Bar of suitable size as per site requirement including bending, turning , making holes for nuts and bolts for connecting of MCCBs, making links for connecting to MCCBs in LT bus bar chamber, LT Panels, APFC panels, LT control Panels with necessary nuts and bolts for fixing of busbar with LT DMC insulators complete all as specified and directed at site

20

-

-

... More
S&F in replacement Copper Bus Bar of suitable size as per site requirement including bending, turning , making holes for nuts and bolts for connecting of MCCBs, making links for connecting to MCCBs in LT bus bar chamber, LT Panels, APFC panels, LT control Panels with necessary nuts and bolts for fixing of busbar with LT DMC insulators complete all as specified and directed at site

30

-

-

... More
S&F in replacement Tinned Copper Bus Bar of suitable size as per site requirement including bending, turning , making holes for nuts and bolts for connecting of MCCBs/ACBs, making links for connecting to VCBs, in HT bus bar chamber, LT Panels, APFC panels, LT control Panels with necessary nuts and bolts for fixing of busbar with LT DMC insulators complete all as specified and directed at site.

30

-

-

... More
&F in replacement LT DMC insulators with suitable size nuts, bolts and washers of suitable size and type for fixing of LT busbar of any type in LT panels, bus bar chambers, APFC panels, LT control Panels, AMF panels complete all as directed at site

30

-

-

... More
S&F in replacement HT DMC insulators with suitable size nuts, bolts and washers of suitable size and type for fixing of LT busbar of any type in LT panels, bus bar chambers, APFC panels, LT control Panels, AMF panels complete all as directed at site

30

-

-

... More
Routine and periodical cleaning the inside area of 11 KV Sub Stations including cutting and removal/uprouting of unwanted grass/bushes, small trees near all around sub station and pump houses complex complete including surface dressing and leveling by surface excavation wherever as required or as directed.

10000

-

-

... More
Taking down old unserviceable LT cables of size 10 sqmm 2 core to 240 sqmm 3.5 core and kept in safe custody for schedule of credit/ relaying complete all as specified and directed.

3160

-

-

... More
M&L for Relaying of LT cables after, jointing or necessary repair work and testing XLPE insulated PVC outer seathed and PVC inner sheath, galvanised steel strips armoured, and reconnecting the cable from over head line and panel suitable for rated voltage of 1100 Volts grade 25 sqmm to 300 sqmm 4/3.5 Core and laid in treches/ducts/pipe or under road/ on wall/pole all as required and directed at site. Note: excavation and earth work joints will be measured and paid seprately.

450

-

-

... More
S&F in replacement Duct Cover Mild steel plates, chequered, 5mm thick or over in available sizes in Fe 410-W (Gde-E-250) quality-A in and including cutting in shapes, bending or making support, notching in appropriate size for housing of LT/HT cables, earthing strips, GI pipes or other similar existing material at site , welding including lefting arrangement of duct cover complete all as specified and directed.

2512

-

-

... More
Dismantling/ taking down of existing street light switching system and Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is 30 lux and for switching off 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw Three phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed. Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclouser - Sintax or equivalent

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.