Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Dec 2024
Closing Date10 Jan 2025
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fix in replacement cable jointing kit for 11 KV (Earthed) grade , Indoor termination heat shrink type, complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 Sqmm to 95 Sqmm all as per manufactuer recommendation complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fix in replacement cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 Sqmm to185 Sqmm all as per manufactuer recommendation complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fix in replacement cable jointing kit for 33 KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 240 Sqmm to 300 Sqmm all as per manufactuer recommendation complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply and fix in replacement cable jointing kit for 33 KV grade out door termination heat shrink type, complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 240 Sqmm to 300 Sqmm all as per manufactuer recommendation complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Taking out old unserviceable HT cable and Supplying, laying, jointing, testing and commissioning of XLPE insulated PVC outer seathed and (earthed) PVC inner sheath, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminum conductors, 11 KV(E) grade and conforming to IS : 7098 and, of size 185 sqmm, 3 core, laid in trenches / ducts / encased in GI pipe / fixed to pole, complete all as specified and directed at site. Note : Earth work, protection pipe and Cable Joints etc shall be measured and paid separately.

120

-

-

... More
Taking out old unserviceable HT cable and Supplying, laying, jointing, testing and commissioning of XLPE insulated PVC outer seathed and (earthed) PVC inner sheath, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminum conductors, 11 KV(E) grade and conforming to IS : 7098 and, of size 120 sqmm, 3 core, laid in trenches / ducts / encased in GI pipe / fixed to pole, complete all as specified and directed at site. Note : Earth work, protection pipe and Cable Joints etc shall be measured and paid separately.

120

-

-

... More
Taking out old unserviceable HT cable and Supplying, laying, jointing, testing and commissioning of XLPE insulated PVC outer seathed and (earthed) PVC inner sheath, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminum conductors, 11 KV(E) grade and conforming to IS : 7098 and, of size 95 sqmm, 3 core, laid in trenches / ducts / encased in GI pipe / fixed to pole, complete all as specified and directed at site. Note : Earth work, protection pipe and Cable Joints etc shall be measured and paid separately.

135

-

-

... More
Supply and fixing in replacement of GI Pipe light grade 80 mm dia with necessary accessories/ fittings bracing with pole/wall by FI clamps made with 32x6mm for cable protections/pole for crossing of culverts/nallah/road and all as specified and directed sizes:-

6

-

-

... More
Excavating in trenches n.exc 1.5 m in width and n.exc 1.5m in depth for taking out cable and cable cover and getting out in any type of soil

160

-

-

... More
All as per ser No-12 above but depth exc 1.5 mtr but not exc 3.00 mtr

4.5

-

-

... More
Returning, filling in, including spreading levelling, watering and well ramming in layers n.exc 25 cm thick in any type of soil complete all as specified and directed by Engr-in-Charge.

110

-

-

... More
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point

50

-

-

... More
M&L for tibba sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. Note :- Punned thickness only be measured for payment purpose.

30

-

-

... More
Supply and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx180mmx40mm laid perpendicular to cable length in trench and air gap should not more than 5mm to each other after sand cushioning to cable complete all as specified and directed by Engr in Charge.

2000

-

-

... More
Dismantling of existing PCC/Steel Pole and S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-64 (12 metres long) complete all as directed by Engineer-in- Charge.

4

-

-

... More
Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole or in any situation complete all as specified and directed.

3.56

-

-

... More
Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole or in any situation including necessary formwork complete all as specified and directed.

2.25

-

-

... More
S&F in replacement of GI stay assembly set comprising of 14mm dia 400mm iron stay bow and16mm dia, 2150mm long stay rod, stay plate 230x230x6mm thick, GI stay wire 7/8 SWG of required length complete with all accessories as shown in electric plate No 1 of SSR Part 1 2009 complete with excavation earth work including PCC 1:3:6 of type C-1 required quantity with loop insulator, clamps nut bolts etc complete all as required and directed.

4

-

-

... More
Taking out old unserviceable PG Clamp and supply and fix new PG clamp in replacement all as directed and specified.

17

-

-

... More
M&L cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nut/bolts washers, welding, bending, cold or hot drilling holes for bolts of any shape and size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking out old unserviceable complete all as directed.

1

-

-

... More
Supply fixing and connecting and testing single pole zinc oxide (gaplesssurge type) heavy duty station class, self supporting outdoor type lighting arrester having rated voltage 30 KV (rms) discharge current 65 KA insulationlevel 35/75 KV/KVP (Peak) suitable for rated system voltage of 33 KV supplysystem with maximum continuous operating voltage (MCOV) not less than17.05 KV (rms) with highly non linear ceramic resister made of zinc oxide inhermetically sealed container complete with metal base, base inculator and suitable terminals for ground connections and pressure relieving arragement complete all as specified. Note : The rate quoted against above item shall include necessary fixing arrangement of lightening arresster on two pole/four pole structure as per recommendations of manufactures.

1

-

-

... More
Supply and Fixing in replacement of Lightning arrestor single pole zinc oxide (gapless surge type) heavy duty station class, self supporting outdoor type lighting arrester having rated voltage 09 KV (rms) discharge current 65 KA insulation level 28/75 KV/KVP (Peak) suitable for rated system voltage of 11 KV supply system with maximum continuous operating voltage (MCOV) not less than 7.65 KV (rms) with highly non linear ceramic resister made of zinc oxide in hermetically sealed container complete with metal base, base inculator and suitable terminals for ground connections and pressure relieving arragement complete all as specified . Note : The rate quoted against above item shall include necessary fixing arrangement of lightening arresster on two pole/four pole structure as per recommendations of manufactures.

4

-

-

... More
Supply and fix in replacement of HT 33 KV outdoor type triple pole gang operated air-break switch double stack type suitable for horizontal mounting rotating type with 9 insulator 200 amps current rating complete mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore medium grade GI pipe of suitable length with locking arrangement, flat iron clamp 50x6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers complete all as directed

1

-

-

... More
Supply and fix in replacement of air break switch gang operated tripple pole mechanically operated mechanism, switch air break gang operated mounted on 15 Nos insulator and steel frame with operating rod of 25 mm bore GI Pipe and locking arrangements worked from ground level for current rating 400 Amps, HT 11 KV grade including drop out fuses and necessary silver coper coating jumpers and making all electrical connections complete.

4

-

-

... More
Supplying and fixing in replacement male contact/moving contact for Horizontal/Vertical gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.

10

-

-

... More
Supplying and fixing in replacement female contact /fix contact jaw for Horizontal/Vertical gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.

10

-

-

... More
Supplying and fixing in replacement tinned copper flexible jumper 200 Amp/400 Amp for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.

10

-

-

... More
Supplying and fixing in replacement MS jumper carrier for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.

10

-

-

... More
Supplying and fixing in replacement back connector plate for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.

10

-

-

... More
Supplying and fixing in replacement porcelain post insulator for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.

10

-

-

... More
S&F in replacement 25 mm bore heavy grade GI pipe including all fitting for HT 11 KV Gang operated air break switch all as specified and directed.

12

-

-

... More
Supplying and fixing in replacement male contact/moving contact for Horizontal/Vertical gang operated air break device 33 KV complete all as directed at site by Engr-in-charge.

4

-

-

... More
Supplying and fixing in replacement female contact /fix contact jaw for Horizontal/Vertical gang operated air break device 33 KV complete all as directed at site by Engr-in-charge.

4

-

-

... More
Supplying and fixing in replacement tinned copper flexible jumper 200 Amp/400 Amp for gang operated air break device 33 KV complete all as directed at site by Engr-in-charge.

4

-

-

... More
Supplying and fixing in replacement MS jumper carrier for gang operated air break device 33 KV complete all as directed at site by Engr-in-charge.

4

-

-

... More
Supplying and fixing in replacement back connector plate for gang operated air break device 33 KV complete all as directed at site by Engr-in-charge.

4

-

-

... More
Supplying and fixing in replacement porcelain post insulator for gang operated air break device 33 KV complete all as directed at site by Engr-in-charge.

4

-

-

... More
M&L for checking , tightening & Replacement of jumpers , clamps connectors of 33 KV bus bar for the Power transformer in the yard / sub station complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
M&L for straightenig of cross arms with clamps including tightening of nut bolts , washers complete all as specified and directed by Engr-in-Charge

30

-

-

... More
M&L for resagging of overhead conductor section of 11 KV including binding/re-binding of conductor with suitable size of wire and providing of jumpers at the ends as per site requirements complete all as specified and directed by Engr-in-Charge. Note :- (i) Length of span shall be 40 to 50m. (ii) Due care shall be given while resagging of overhead conductor that there shall be no damage to pin/post/disc insulator and pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible.(iii) Proper shut down will be taken from department and T&P will be provided by conractor.

30

-

-

... More
M&L for replacement of rusted/broken GI earth wire of 4 mm dia for guard on Overhead line by providing reels and clamps and any other items required for fixing as per site requirement complete all as specified and directed by Engr-in-Charge.

500

-

-

... More
Dismantling and taking down HT pole of old ACSR conductor complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
M&L for Replacement of old ACSR conductor with new ACSR conductor including binding of wire and providing jumpers at the end as per site requirement complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Fixing and restringing of old serviceable (ACSR) conductor obtained from items No 45 here in before including binding complete all as specified and directed.

1

-

-

... More
M&L for replacement of defective/damaged type Pin type, pocelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvaanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade with fixing on existing 2 pole/4pole/single pole including taking down of old unsv insulator and all as specified and directed.

9

-

-

... More
Supply and Fix Disc type insulator porcelain, vitreous 145mm high and 255 mm dia ball and socket type white, brown or green, double disc with tension clamp for conductor for working pressure voltage 11000 V including dismantling/ taking out unserviceable from Pole complete all as specified and as directed.

2

-

-

... More
Taking out old unserviceable 33 KV pin insulator incl taking out 33 KV OH ACSR conductor and supply and fix 33 KV pin type, porcelain, vitreous, insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for fixing of insulator on HT pole incl refixing the OH ACSR conductor at the same place incl binding the conductor to insulator with new binding wire complete all as directed.

6

-

-

... More
M&L for replacement of defective/damaged Disc insulators suitable for 33 KV overhead conductors including removing/providing jumpers with line conductors as per requirement at site complete all as specified and directed by EIC.

3

-

-

... More
M&L for painting with two coats of synthetic enamalled paint over one coat of red oxide primer on cross arms, bracing supports clamps,MS sheet from structural steel sections including Tower poles of 33 KV Line From Surpura 33 KV Yard to Nagtalao 33 KV Yard & before painting completely clean the rust on iron complete as directed . Note :- Proper Shutdown of 33 KV shall be taken before commencement of painting work.

70

-

-

... More
Material and labour for Periodical servicing & Calibration of switch gear VCB of capacity 400-630 Amp capacity,33KV indoor/Outdoor type including control remote panel by tripping off the breaker servicing and overhauling the mechanical parts with applying the grease and checking the control wiring and tripping mechanism, replacement of damaged minor parts such as control wiring, ferrules, HRC fuse, caliberation of processor numerical/digital relay existing on panels with secondery injection kit and setting the relay of earth fault, short circuit, time delay settings as per existing load of feeder and all as specified and direted by engr-in-charge at Power House Nagtalao.

6

-

-

... More
Material and labour for Periodical servicing & Calibration of HT switch gear VCB of capacity 400-630 Amp capacity ,11KV by tripping off the breaker and draw out the trolley and servicing and overhauling the mechanical parts with applying the grease and checking the control wiring and tripping mechanism, replacement of damaged minor parts such as control wiring, ferrules, HRC fuse, caliberation of IDMT/Microprocessor numerical/digital relay existing on panels with secondery injection kit and setting the relay of earth fault, short circuit, time delay settings as per existing load of feeder and all as specified and direted by engr-in-charge at Nagtalao Area

16

-

-

... More
Disconnecting HT Supply, 11 KV opening the RMU (indoor/outdoor) after positioning the earth of indl feeder, material and labour for servicing /testing of RMU/control panel including CT, PT and relays in control panel of RMU of capacity 630- 800 Amp, 3-4 way and rating 11 KV complete as details mentioned as under:-

1

-

-

... More
(a) Details of servicing of RMU :- (i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust and dirt and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts. (vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish.

-

-

-

... More
Supply and fix Over Current and Earth fault protection relay suiable for 33/11 KV VCB Panel complete all as specified and directed by Engr-in-Charge. Model SLR 140 C of CG or its equivalent.

2

-

-

... More
Supply and fix Master Trip relay operating viltage 110V AC and 24V DC suiable as per existing make for 33/11 KV VCB Panel complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fix announciator panel 12 window type as per existing make and capacity complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fixing in replacement Buch, WTI , OTI Trip relay suitable existing size for 33/11 KV VCB Panel complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fixing in replacement Digital Volt meter suitable for HT VCB Panel complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fixing in replacement Digital Ammeter suitable for HT VCB Panel complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in replacement Auxialiary relay for Buch, WTI,OTI Alarm suitable for HT VCB Panel all as specified and directed by Engr-in--Charge. Model: CGXH1 3 element Aux relay or its equivalent

1

-

-

... More
Supply and fixing in replacement of Spring charging Motor 230V AC/DC universal type for existing VCB complete all as specified and dirtected by Engr-in-Charge

1

-

-

... More
Supply and fixing in replacement of Gear assembly Big size for existing VCB complete all as specified and dirtected by Engr-in-Charge

1

-

-

... More
Supply and fixing in replacement of Gear assembly small size for existing 11 KV VCB complete all as specified and dirtected by Engr-in-Charge

2

-

-

... More
Supply and fixing in replacement of Trip holding Shaft for existing 11KV VCB complete all as specified and dirtected by Engr-in-Charge

1

-

-

... More
Supply and fixing in replacement of Trip coil for existing VCB complete all as specified and dirtected by Engr-in-Charge

2

-

-

... More
supply and fixing in replacement of Close holding shaft for existing VCB complete all as specified and dirtected by Engr-in-Charge

1

-

-

... More
supply and fixing in replacement of Close coil for existing VCB complete all as specified and dirtected by Engr-in-Charge

3

-

-

... More
Supply and fixing in replacement of spring suitable for 11 KV VCB 400-630 Amp complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of Drum Switch for 11 KV VCB 400-630 Amp complete all as specified and dirtected by Engr-in-Charge

1

-

-

... More
Supply and fixing in replacement of Anti Pumping device 24V DC for existing VCB complete all as specified and dirtected by Engr-in-Charge

2

-

-

... More
Supply and fixing in replacement of Vaccum interruptor for existing VCB complete all as specified and dirtected by Engr-in-Charge

1

-

-

... More
Supply only in replacement Limit switch complete all as specified and dirtected by Engr-in-Charge

1

-

-

... More
Supply only in replacement TNC switch for 11 KV VCB breaker as per existing make and specification and directed by EIC

4

-

-

... More
Supply only in replacement Local remote switch for VCB breaker as per existing make and specification and directed by EIC

2

-

-

... More
Supply and fixing in replacement of 11 KV VCB trolly gear having 9 teeth complete all as specified and directed by Engr-in-Charge

1

-

-

... More
Supply only in replacement Service position switch for existing 11 KV VCB complete all as specified and directed by Engr-in-Charge

1

-

-

... More
Supply only in replacement Local remote switch for existing11 KV VCB complete all as specified and directed by Engr-in-Charge

1

-

-

... More
Taking out Old unserviceable indicator lamp from 11 KV VCB Panel and Supply and fix new phase indicating lamp neon type 24DCV/110DCV complete as per existing make and size with contct block & holder assembly of RYB Colour as directed

16

-

-

... More
Supply and fixing in replacement Dual Core CT Indoor type suitable for 11000 volts for existing VCB complete all as specified and directed by Engr-in-Charge

1

-

-

... More
Supply and fixing in replacement 11 KV PT resin cast ration 11KV /110V 25VA class 0.2 for existing VCB complete all as specified and dirtected by Engr-in-Charge

1

-

-

... More
Supply and fixing in replacement of Insulating rubber matting ISI mark for 11KV 2.50mm thickness of matt confirming to IS:15652-2006 complete fixing on floor with suitable pasting material complete as per specification as directed by EIC

15

-

-

... More
Supply ,fixing and testing in replacement of 12V 2Ah battery 55 Nos for output 110 V DC ( 55 Nos battery for 2 Ah in series connection installed on iron rack suitable for battery holding in three compartment) maintence free battery complete connected to existing HT VCB Panel of 33/11 KV complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Disconnecting electric outdoor/indoor Power transformer 33 KV capacity upto 2000 KVA from HT/LT terminals and lowering down/getting out from 2/4 pole structure/plinth or from inside sub station for major/Minor repair and transportation to workshop and return back for installation it on original position/location after repairing from workshop complete all as specified and directed . Note : (Rate is deemed to be inclusive of transportation, T&P and man power)complete all as specified and directed .

1

-

-

... More
Labour for strip opening of Power transformer up to 2000 KVA & physical joint inspection of core coil assembly (removing all 3 limb HV & LV winding from core assembly) , washing of core assembly hot oil for removing burnt carbon & copper particles & cleaning of complete top yoke by oil , reassembly of complete core assembly & core coil assembly rewinding with new coils and new tap leads of OLTC, re-taning, tightening of top cover , fixing of HV and LV bushing, OLTC overhauling, Filling of New oil, conservator tank and Drying/Ovening of complete CCA in vaccum Chamber & continues monitoring for Improvement of IR Value. Note :- (i) The quoted rates shall be deemed to include minor parts like nuts, bolts, washers of different sizes and gasket from top cover ,4.0mm/6.0mm (ii) HT/LT leg coils, HV/LV Bushing including brass spindle and transformer oil shall be measured and paid separately under respective items of schedule. (iii) Contractor shall submit one year guarantee effective from date of commissioning of the transformer.

1

-

-

... More
Supply only HT/LT coils with super enamelled copper wire/strip /DPC of high quality duly matching with the existing guage and impedance complete all as specified and directed ..

50

-

-

... More
Material and Labour for ON load centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine electric operated without any shutdown of transformer including testing oil sample before and after dehydration and filteration oil complete all as specified and directed . Note : (i) Transformer oil required for top up shall be measured and paid for separate (ii) Contractor have to arrange the dehydration machine and testing kit from his own resources without any extra cost. (iii) dielectric strength of transformer oil not less than 45 KV at 2.5 mm gap (iv) Record of dehydration to be maintained duly sign by GE, Engr-in Charge & Contractor

7200

-

-

... More
Supply and filling the transformer oil in factory sealed barrel with IS-336 of di-electric strength not less than 45 KV at 2.5 mm gap and toping up the oil where ever required in Army area Nagtalao and all as specified and directed.

400

-

-

... More
Preventive maintance /servicing and testing of power transformer 1.0/2.0 MVA of 33/11KV at MRSS Ralawas, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge. (a). Magnetic balance test (b). IR Test (c).WTO/OTI tripping (d).Oil level and leakage (e). Transformer oil test (i). earthing valve check body and netural (ii).Megar/dielectric streanth Complete all as specified and directed by EIC. Note.The test shall be carried out by authorised vendor of transformer and contractor will submit Test report at the time of payment of RAR/Final Bill. .

1

-

-

... More
Preventive maintance /servicing and testing of power transformer 1.0 MVA of 33/11KV at MRSS Ralawas, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge. (a). Magnetic balance test (b). IR Test (c).WTO/OTI tripping (d).Oil level and leakage (e). Transformer oil test (i). earthing valve check body and netural (ii).Megar/dielectric streanth Complete all as specified and directed by EIC. Note.The test shall be carried out by authorised vendor of transformer and contractor will submit Test report at the time of payment of RAR/Final Bill. .

1

-

-

... More
Disconnecting electrically & mechanically indoor/outdoor transforemrs upto 500 KVA capacity carefully for prevent/stoping for leakage of transformer oil by welding / tightening the loose points at site, including opening of top cover, draining out transformer oil and other items and storing the oil in suitable container (container to be provided by the contractor to keep aside for re -use) including replacement of all unserviceable gasket, replacing the unsv HT/LT porcelain Bushing/studs as directed after repairing/stoping of oil leakage the same re-connecting electrically and mechanically, testing complete all as specified and directed. Note. (i) (i) The quoted rates shall be deemed to include minor parts like nuts, bolts, washers of different sizes and gasket from top cover 6.0mm thick (i) The HT/LT porcelain Bushing & transformer oil for topup shall be measured and paid separately under respective items of schedule.

16

-

-

... More
Supply and fixing transformer bushing on LT 433 volt side including brass spindle/rods duly threded at the end complete with gasket nut bolts and washer suitable for indoor/outdoor transformer capacity 63 KVA to 160 KVA complete all as specified and directed .

6

-

-

... More
All as per item No 93 above but of capacity 200 KVA to 400 KVA

6

-

-

... More
All as per item No 93 above but of capacity 500 KVA.

3

-

-

... More
Supply and fixing in porcelain transformer bushing HT 11 KV including brass spindle/rods duly threded at the end complete with gasket nut bolts and washer suitable for indoor/outdoor transformer capacity 63 KVA to 160 KVA complete all as directed by Engineer-in-Charge.

6

-

-

... More
All as per item No 96 above but of capacity 200 KVA to 400 KVA

6

-

-

... More
All as per item No 96 above but of capacity 500 KVA

3

-

-

... More
Supply and Fixing in replacement of transformer silica gel breather complete with all accessories for transformer of capacity 63 KVA to 160 KVA complete all as specified and directed.

2

-

-

... More
All as per item No 99 above but of capacity 200 KVA to 400 KVA

2

-

-

... More
All as per item No 99 above but of capacity 500 KVA

1

-

-

... More
All as per item No 99 above but of capacity 33/11 KV, Upto 2.0 MVA

2

-

-

... More
Supply and fill in replacement silica gel in transformer complete all as directed.

4

-

-

... More
Material & labour for replacement of oil level indicator of Transformer of any Cap all as directed by Engineer-in-charge

1

-

-

... More
S&F in replacement Thermometer of transformer capacity upto 2000 KVA complete all as specified and directed

1

-

-

... More
S&F in replacement the off load Tape changer suitable to 63 to 500 KVA indoor/outdoor transformer with fixing suitable make and fixing and making connection all as required and directed at site .

1

-

-

... More
M&L for cleaning, scraping out old rubbed paint / rust & Painting of transformer complete with two coat of spray painting with synthetic enamelled gray paint (first grade) by spray painting machine on transformer & Making SM NO on surface of transformer of Different capacity outdoor / Indoor type fixed on poles or in Sub Station at different location all as specified and directed.

18

-

-

... More
M&L for Surface excavation n.exc 30 cm deep and averaging 15 cm and geeting out in any type of soil incl cutting and removing grass, vegetation, bushes/shrubs etc from surrounding of 02 Pole/ 4 Pole structure and LT/ HT Panel E/M installations and removing all rubbish and dressing the gravel/soil and spaying the one time herbicide approved brand (Roundup/Noweed) to prevent the further vegetation and all as specified and directed.

600

-

-

... More
Supply and laying the graded coarse stone aggregate 40mm size for E/M installations of 33KV MRS yard/2/4 pole HT/LT pole structures/surrounding area of RMU including cleaning the vegetation developed and making plane of surfece and all as specified and directed at site.

30

-

-

... More
Supply and laying the graded coarse stone aggregate 20mm size for E/M installations of 33KV MRS yard/2/4 pole HT/LT pole structures/surrounding area of RMU including cleaning the vegetation developed and making plane of surfece and all as specified and directed at site.

30

-

-

... More
M&L for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for 33KV yard/sub stn protection for aggreagte complete all as specified and dirtected

80

-

-

... More
Material and labour for cutting the branches/trees near the HT OH line upto clearance area 5mtr around OH line by cutting the branches and removing the wastage from site to disposal area and all as specified and direced, Note :-(i) The necessary man power tool and plant , cutting tools and JCB if required for cutting/ prunning of branches is deemed to incl in the rate quoted for the job (ii) Proper shut down will be taken from JE E/M only.

100

-

-

... More
Dismantling solid angles, slotted angles, channels of any section, including taking out embedded portion in concrete and making good distrubed ground complete all as specified and directed by Engr-in-Charge.

2.5

-

-

... More
Supply and fixing M.S. structural work fabricated from standard sections i.e. solid angles, slotted angles, channels , fillets,supports including cutting to size, drilling, welding and fixing as directed by Engineer-in-Charge.

250

-

-

... More
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion in concrete and making good distrubed ground complete all as specified and directed by Engr-in-Charge.

41

-

-

... More
Excavating in post holes (or similar holes) each n.exc 0.50 Cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm incluidng watering and removing surplus soil th a distance n.exc 50m and making good surface in hard/dense soil complete all as specified and directed.

15

-

-

... More
M&L for rolled steel section as in posts, struts and staples in fencing including cutting to top to shape (swan neck) as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary bolting or riveting welding etc and similar work confirming to Fe-290 Gde-165 complete all as specified and directed by Engr-in-Charge. Note -: fencing posts should be painted before fixing

239

-

-

... More
Dismantling of wrought iron or mild steel work including of any description not otherwise provided for complete all as specified and directed

0.49

-

-

... More
M&L for rolled steel section framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings including all necessary bolting or riveting welding etc and similar work confirming to Fe-290 Gde-165 complete all as specified and directed by Engr-in-Charge

49

-

-

... More
M & L for two coats of synthetic enamalled paint over one coat of red oxide primer on new steel surfaces exc 100mm width or girth, including preparation of the surface complete all as specified and directed.

13

-

-

... More
Dismantling of fencing wire mesh any type and any size complete all as specified

94

-

-

... More
Supply only Chain link MS galvanised fencing, any size or type, complete all as specified and directed. Note :- A BOO shall be detailed by GE to ascertains the unit weight of chain link fencing.

264

-

-

... More
Fixing only chain link fencing including line wires/ MS round bar (Any numbers), any mesh, size and type to any type of standards rails, straining bolts, etc including provision of binding wire (Note. Supply of flat iron, MS round bar & chain link shall be measured and paid seperately under supply only)

94

-

-

... More
S & F 12 mm dia MS screw bolts any size (machine made) with hexagonal or square heads at one end and screwed the other ends, fitted with washer and one one hexagonal nut exc 5cm long but n exc 10cm cmplete all as specified and directed.

12

-

-

... More
Supply and fixing MS rounded bars Fe-290 (Gde-165) 10 mm dia and over cut to length and bend to shape as required as in tie bars, secured with nut, bolt and washers complete all as specified and directed by Engineer-in-Charge.

111

-

-

... More
Demolition of Brickwork, PCC or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-charge.

4.3

-

-

... More
M&L for squared rubble walling Jodhpur type regular course well bonded bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.

4.3

-

-

... More
Extra over on stone walling for hammer dressing to face stone with maximum depression on face from straight edge n.exc 20 mm and dressing faces beds and joints as specified to square rubble walling regular course Jodhpur type all as specified and directed.

13.35

-

-

... More
Material and labour for 15mm thick rendering in CM 1:4 mixed on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.

0.29

-

-

... More
Material and labour for preparation of newly plastered surface of walls and applying two coats of cement base paint over one coat of alkali resistance primer complete all as specified and directed by Engineer-in-Charge.

14.4

-

-

... More
Dismantling of existing test point and Supply and fix test point terminal block made of Gun metal or phosphorus bronze size 75X75X25 mm drilled and screwed including 3 nos 8 mm dia 25 mm long hex head screw complete all as specified and directed by Engr-in-charge.

6

-

-

... More
Materail and labour for relacement of unserviceableexisting earthing with bore well earthing with the help of mechnical boring machine of 150mm dia 30 mtr depth excuting 50mm dia medium GI pipe duly drilled all around 150mm dia hole at a distance of 200mm from hole to hole upto min 20 mtr depth upto water level including supply and fix 150mm dia (O.D) UPVC pipe 6 Kg/sqcm rating -06 mtr long with the help of suitable size clamps with nuts bolt and washer -01 Nos including charcoal dust,salt fill in bore well for earh conductivity M&L for providing 32X6 mm GI strip upto 10 mtr protected by GI pipe 40mm dia medium grade in ground and coonected to terminal block grounding of borewell withPCC(1:2:4) type B-1 / brick massonary pit of size 45X45X45Cm complete and give the minimum earth test result below 1 ohm complete all asspecified and directed by Engr-in-Charge Note:-(i) The charge for mechnical boring machine, UPVC pipe 150mm dia length 6 mtr ,GI strip 32X6mm with protection GI pipe 40mm dia medium grade &PCC work is deemed to be include in above qouted rate . (ii) GI tubing 50mm dia medium grade deemed to be include in above qouted rate . (iii) Earthing shall be tested by contractor in presence of JE/Engr-in-Charge and record shall be maintained .

4

-

-

... More
M&L for earthing in replacement with galvanized steel earth plate of size 60 cm x 60 cm x 6 mm thick electrode buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth, GI wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron all as shown in electrical plate No.3 of MES SSR Part I connected to earth test terminal point all asa specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil,earth work,PCC pit,PCC cover,funnel with watering pipe, wire mesh, common salt, charcoal etc.all as required at site for complete earthing

1

-

-

... More
M&L for earthing in replacement with galvanized steel earth plate of size 60 cm x 60 cm x 6 mm thick electrode and 32x6mm GI strip length up to 7.5 mtr as earth lead, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth, GI strip of size 32X6 mm dia by means of bolts, nuts, washers of galvanized iron all as shown in electrical plate No.3 of MES SSR Part I connected to earth test terminal point all asa specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil,earth work,PCC pit,PCC cover,funnel with watering pipe, wire mesh, common salt, charcoal etc.all as required at site for complete earthing

4

-

-

... More
Dismantling of existing earth continuity and M&L for earth continuity conductor or main earthing lead fixed to wall on insulators or recess or chases or buried in ground or drawn in conduit/pipe for loop earthing etc. as required 32x6mm galvanized strip complete all as specified and as directed by EIC.

30

-

-

... More
M&L for painting with two coat alunium colours at 33 KV MRS Yard ( 14Nos ) Tower pole 12 mtr height horizental arms and other structures etc complete including all clamps,bars,iron item inside the yard as per site existing complete all as per directed by EIC

1

-

-

... More
M&L for painting with two coats of synthetic enamel paint over a coat of cross arms, bracing supports clamps,MS sheet from structural steel sections including steel poles/Tower poles and mud clay on RCC pole( 2 Pole & 4 Pole also including) before painting completely clean the rust on iron complete as directed . Note :- The item included in the painting 3 Nos 30 cm wide bands black & White synthetic enamel paint in alternate layer upto 1.0 mtr high above foundation and writing the pole No in 5 cm wide on base of Black colour with HT as per direction of Engr-in-Charge.

23

-

-

... More
Supplying & Fixing in replacement Caution plate “CAUTION MEN AT WORK" of size 40cmx30cm made out of ACP Sheet with Red coloured

4

-

-

... More
S&F in replacement of 3 Pole 12 Amp contractor confirming to IEC-60947-4-1 complete all as specified as dirtected.

1

-

-

... More
S&F in replacement of 3 Pole 12 Amp overload protection relay confirming to IEC-60947-4-1 complete all as specified as dirtected Make:- Siemes/L&T or equivalent

1

-

-

... More
S&F in replacement of Electronic timer 03-30 sec 415V 50Hz with mounting kit suitable as per site requirement all complete all as specified as dirtected by EIC.

1

-

-

... More
S&F in repair expulsion fuse (drop out fuse) mounted on 2 Nos of HT insulators, single pole upto 50 Amps 11 KV with spring mechanism complete in all respects and connection as directed.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.