Military Engineer Services Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 73,529Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_696613_1Bid Award Id
ViewTender No
8296/GE/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for rendering 10mm thick on concrete surfaces of any description in cement mortar (1:6) is to be finished even and smooth (without using extra lime or cement) complete all as specified and directed.
25
-
-
... More
Supply, laying or fixing or passing through GI pipe, commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of size 10 sqmm 2 core cross section area including suitable size lugs complete all as specified and directed at site
Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
90
-
-
... More
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site.
418
-
-
... More
M&L for tibba sand for cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
127
-
-
... More
M&L for 40 to 50 mm thick rough dressed Jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cable including taking down all as specified and directed.
1383
-
-
... More
M&L for Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
214
-
-
... More
M&L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
277
-
-
... More
M&L for GI Tubes, of size 40mm bore, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed.
81
-
-
... More
S&F for Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way single pole and neutral complete all as specified and directed.
7
-
-
... More
S&F for MCB, 40-63 Amp, SPN, 240 Volt. complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
S&F for MCB, 6 to 32 Amp, SP, 240 Volt. complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
M&L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 6.00 Sq mm 1100 volts grade including and 6.00 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in conduit Engineer-in-Charge. Note :- Two run of 6.0 Sqmm cable and one run of 6.0 Sqmm cable as earth continuity conductor shall be measured & paid as one unit.
17
-
-
... More
M&L for Antistatic Flooring 3 mm thick vinyl for electrostatic discharge as per manufacturers specifications complete including scraping down the existing surface to finished level appropriate for laying of the ESD surface all as specified and directed by Engineer-in-Charge.
18
-
-
... More
M&L for copper strip 20 x 3mm with saddles and fixing screws etc for roof conductors and down conductors above ground and connected to existing earthing complete all as specified and directed by Engineer-in-Charge.
45
-
-
... More
M&L for earthing complete with CPRI tested 50mm dia, pure copper earth electrode pipe of length 3000mm, pipe in copper strip Technology with NABL tested, RoHS compliant earth enhancement compound 50 Kg in each bore hole in tripod configuration (three numbers of 50mm dia pure copper electrode pipe) interconnected with copper strip of size 20x3 mm and connected by means of exothermic brazing & porected by GI pipe light grade 32mm bore and PCC (1:3:6) type C1 earth chamber & cast iron earth pit cover 300x300x3mm connecting to test point & testing on ground complete includingexcavation, earth work, boring in any type of soil strata & cleaning of site complete all as specified and directed.Note (i) Cost of copper strip 20x3 mm and 32mm dia GI pipe light grade required for interconnection of three numbers of pure copper 50mm dia earth electrode and 7.5 mtr 20x3mm strip and 05 mtr of 32 dia GI Pipe, light grade is deemed to be included in unit quoted rates. (ii) Cost of earth work, boring, PCC earth pit, CI cover, testing of earth after completion, connecting and commissioning is deemed to be included in unit quoted rates.(iii) Marking & painting of earth pit with iron plate of suitable size is deemed to be included in unit quoted rates(iv) The boring will take place for 3 meter depth & 350mm dia for three numbers of pure copper earth electrode pipe to form tripod configuration. Earth enhance compound to be filled around the earth electrode in 100mm dia in 3 layers of 1 mtr each by means of PVC pipe of 100mm dia as casing/formwork. The remaining volume of bore shall be filled with clay soil (available from vicinity) in 3 layers of 1 mtr each. The PVC pipe to be removed sinultaneously. The cost of all this is deemed to be included in the quoted rate.(v) Minimum distance between each earthing is not less than 3 running meter.(vi) Testing of earthing shall be conducted and result should be less than 1.00 Ohms
2
-
-
... More
Supply and fix 32 Amps rating 2P+E industrial wall mounted plug socket complete all as specified and directed.
1
-
-
... More
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR.
2
-
-
... More
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site.
51
-
-
... More
M&L for tibba Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
15
-
-
... More
Supply, laying or fixing or passing through GI pipe, commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of size 25 sqmm 3.5 core including providing of suitable size cable lugs. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
215
-
-
... More
Drilling (Horizontally) existing road ( Maximum 10 mtr wide) suitable for passing GI tubing upto 80/100mm complete all as specified and directed.
12
-
-
... More
Design, supply, erection, commissioning and testing of outdoor type LT feeder pillar box, double door, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Copper bus bar not less 150 Amps for distribution system and type tested at CPRI, fabricated in factory having modern fabrication and testing facility which includes seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032.The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.15mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom and having welded equal angle of 75mmx75mmx6mm of length 0.9mtr, 04 nos, 30cm of of angle shall be embedded in PCC 1:2:4, 20mm graded stone agregate below GL level and 30cm shall be above ground level of size as directed by Engr-in-charge at site. The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. Necessary cable gland shall be provided for all incoming and outgoing cables. The feeder pillar shall be comprising of the followings and all as shown in drawings :- CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables, INCOMING :- MCCB 100 Amps, 4 pole, 415 volts, 16 kA, 50 Hz, thermal magnetic release - 01 Nos.OUTGOING : (a) MCCB 63 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, thermal magnetic release - 01 Nos.(b) MCCB 40 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, - 02 Nos.(c) MCB 40 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, - 02 Nos.(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos.(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 100 Amps, accuracy class 1% - 01 Nos .(f) Current transformer (CT) of rating 100/5, tape wound, rated burden 5 VA - 03 Nos .(g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01).(h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (j) PVC insulated Copper conductor cable shall be used for branch connection of suitable size and length from main bus bar to MCCBs and MCBs - 05 Nos.(k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (l) Danger Notice Plate -02 Nos.(m) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 1.20 Sqm front area) .Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurement of LT panel for approval alongwith CPRI approval. Foundation will prepared as per instructions of manufacturer and rate of fondation shall be deemed to be included in the quoted rates.
1
-
-
... More
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
12
-
-
... More
Supply and erecting steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410 SP 55 of 11 mtr long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emebeded portion shall be painted with two coat of black bituminous paint all as specified in IS with following specifications:-
(i) Excavation in trenches in any types of soil ,returning filling in & well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points.
(ii PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation bedding of size 600x600mm, 200mm base all as specified and directed .
(iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level of size 600x600mm for casing of pole upto planting depth.
(iv) PCC (1:2:4) type B-2 using 20mm graded stone aggregate as in coping including necessary form work above GL level. (v) Writing pole No with yellow shade on black base using synthetic enamel paint having height of words exc 5 cm as directed by Engr-in-charge.
6
-
-
... More
Supply, laying or fixing or passing through GI pipe, commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of size 10 sqmm 4 core cross section area including suitable size lugs complete all as specified and directed at site.
Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
870
-
-
... More
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site.
189
-
-
... More
M&L tibba sand for cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engineer-in-Charge.
57
-
-
... More
Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is 30 lux and for switching off 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw Three phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed by the Engineer-in-Charge. Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclouser - Sintax or equivalent
6
-
-
... More
Supply & fixing MS Cross arms , bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding , bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. Note : Unexposed surface shall be given one coat of primer only.
2.5
-
-
... More
Supply, fixing connecting and testing LED flood light of capacity 150 watt, aesthetically design, having epoxy powder coated pressure die cast aluminium housing with IP 66 protection efficient high output emitter LED for better thermal management of capacity 150W(5700K CCT) , individuals LED's should have lenses for better throw across, system luminous efficacy lm/w grater than or equal to 100lm/w, high efficiency long life LED module with SMD LED package mounted on MCPCB, viewing angle 120 degree, high quality toughened glass cover, IK 07 powered by 02 Nos , inetgral , isolated electronic LED drivers (SMPS based constant current supply) with lower THD output open/short circuit protection, over voltage protection, surge voltage, protection with SPD not less than 10 KV and other sagety test as Per IS-15885 part -2/sec 13, the LED flood light should be LM 79 report and IES file, complete all as specified and directed
36
-
-
... More
M&L for cutting of black top cover of existing road upto 0.6 mtr depth and upto 45cm wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 upto 30cm from top of the road surface complete all as specified and directed by Engr - in-charge
5
-
-
... More
Supply, fixing and connecting elastomer insulated, flat,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 complete
72
-
-
... More
Supply, laying or fixing or passing through GI pipe, commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of size 10 sqmm 2 core cross section area including suitable size lugs complete all as specified and directed at site
Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
62
-
-
... More
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site.
11
-
-
... More
M&L for tibba sand for cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Supply and fixing wall mounted fan, 400 mm sweep, 230 volts, swing type, with remote, in and including all fixing/mounting arramgements complete all as specified and directed at site
4
-
-
... More
M&L for surface point wiring with PVC insuleted unsheathed 1100 Volts grade single core multistranded Copper conductor cable 1.5 Sqmm drawn and including PVC casing capping and accessories, fixed on wall/ ceiling etc with necessary fixing accessories and earth continuity conductor cable of size 1.5 Sqmm green colour Connected to common earth and earth dolly including cast iron/pressed steel terminal/wooden boxes(as per site requirment) Covered with laminated sheet top cover switches/ sockets/ fan regulators fixed with cadmium plated machine screws all as specified for the following: (a) One socket outlet 3 Pin, 6 Amp on independent board
4
-
-
... More
S&F for switch piano flush type single pole one way 5 Amp (ISI Marked)
4
-
-
... More
S&F for socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked)
4
-
-
... More
Supply, laying or fixing or passing through GI pipe, commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of size 10 sqmm 2 core cross section area including suitable size lugs complete all as specified and directed at site
Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
920
-
-
... More
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site.
216
-
-
... More
M&L tibba sand for cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
65
-
-
... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of of rating SPN 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed
3
-
-
... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of of rating SP 5 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed
18
-
-
... More
M&L for cutting of black top cover of existing road upto 0.6 mtr depth and upto 45cm wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 upto 30cm from top of the road surface complete all as specified and directed by Engr - in-charge
3
-
-
... More
M & L for boring hole under the road / pavement / hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting GI pipe of size 100/80 mm not less than one metre below ground level complete all as specified & directed by Engineer-in-charge.
12
-
-
... More
Surface excavation in soft/loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out
60
-
-
... More
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
3
-
-
... More
M & L for machine pressed precast concrete interlocking paver block rubber moulding any shape and size with grey cement and pigment cnfirming to IS-15658-2006 of 60 mm thickness, M-35 grade over and 25mm thick sand/stone dust complete all as spfd & directed by Engr-in-Charge. (Sand cusion paid separetely)
40
-
-
... More
M & L sand filling under floors or in cushion layer complete all as spd and dir.
1
-
-
... More
M&L 75 mm thick Cement concrete 1:4:8, type D-2 ( using 40mm graded stone aggregate)as in sub-base/hard standing complete all as specified and directed.
40
-
-
... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), includingmaking drainage opening wherever required complete.
1.8
-
-
... More
Surface excavation n exc 30cm deep and averaging 24cm deep and getting out in ordinary/loose soil.
31.57
-
-
... More
Removing of surplus excavated soil obtained from item No 1 above to a distance exc 250m but n exc 500m and depositing where directed at a level n exc 1.5m above the starting point.
31.57
-
-
... More
M & L hard core of gauge n. exc 63mm, deposited, spread and levelled in layers n. exc 15cm thick watered and rammed to a true surfaces in broken stone or boulders.
19.73
-
-
... More
M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone agg as in sub-base including formwork etc all as specified and as directed.
100
-
-
... More
Factory made chequered cement concrete tiles, 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with mixture of grey cement and pigment over and including 15mm thick screed bed in cement and sand mortar 1:6 complete all as specified and directed.
100
-
-
... More
M&L for PCC 1:2:4 type B1 (using 20mm graded stone agg) in coping, benching of manholes etc, and including necessary formwork etc all as specified and as directed.
3.15
-
-
... More
M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railiings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed.
36
-
-
... More
M & L Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed.
66.02
-
-
... More
M & L for RCC 1:2:4 (using 20mm graded stone agg) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like and set in cement mortar 1:4 complete all as specified and directed.
1
-
-
... More
M&L for precast cement concrete (1:3:6) type C1 (20mm graded stone aggregate) solid block masonary exc 10 cm in width and set in CM (1:6)
2.5
-
-
... More
M&L for rendering 10mm thick on stone / concrete block masonry surfaces of any description in cement mortar (1:6) is to be finished even and smooth (without using extra lime or cement) complete all as specified and directed.
30
-
-
... More
S & F for Framed work as in doors or gates of angle or other sectionwith gusset plates,rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooksn and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-410 W (Gde E-250 Quality B)
35
-
-
... More
Supply only 10mm MS round or square bars, as in horizontal line wire/bar in available lengths, complete all as specified and as directed.
35
-
-
... More
M&L for RCC nominal mix type B1 (1:2:4) using 20 mm graded crushed stone aggregate in Spiral staircases (including landings) complete all as specified and as directed.
1
-
-
... More
M&L for TMT bars 6 to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed.
25
-
-
... More
S&F for framed double door steel cabinet cover of thickness 1.25 mm of size appx 2.1x1.2 m pre painted and fixed firmly on site masonary/concrete shelves with locking arrangements and key set complete all as specified and as directed.
3
-
-
... More
M&L for glazed coloured ceramic tiles 7-8mm thick (square or rectingular)area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 etc complete.
15
-
-
... More
M&L in repair for Machine pressed precast conctete interlocking paver block any shape and size with gray cement and pigment confirming to IS -15658-2006 of 60 mm thickness, M-35 Grade
55
-
-
... More
M&L 25 mm thick sand cushoning for fixing of paver block
1.38
-
-
... More
M&L 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) finishing surface even and smooth without using extra cemnt as in floor & Plinth protection.
10
-
-
... More
M&L for preparation of newly plastered of wall surfaces and applying two coat of oil emulsion distemper over a coat of cement primer in different tints in sigma / camouflaging pattern as approved complete all as specified.
30
-
-
... More
M&L for square rubble walling Jodhpur type brought up to courses well bonded, bedded and solidly hearted in cement mortar 1:6 etc complete all as specified.
3
-
-
... More
M&L for 15mm thick rendering in CM 1:4 on stone / concrete block masonry surfaces other than fair faces of concrete / brick is to be finished even and smooth (without using extra lime or cement) complete all as specified.
30
-
-
... More
M&L for preparation of newly plastered of wall surfaces and applying two coat of oil emulsion distemper over a coat of cement primer in different tints in sigma / camouflaging pattern as approved complete all as specified.
30
-
-
... More
S&F SFRC drain covers with rectangular shape of size 44x26 inch M-10 fixed at site upto satisfaction of Engr-in-charge .
48
-
-
... More
M&L 75MM thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as sub base.
22
-
-
... More
S & F pull push or manual type steel rolling shutter with thickness of laths 1.00 mm including top cover, anchoring rod, hasp and staple and one shop coat of primer and erect in position all as specified and as directed.
8
-
-
... More
M&L for mild steel conforming to Fe-410-W(Gde E-250) as in plates chequerred ,channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachement.Cutting as per size welding ,framing all including for duct cover.
740
-
-
... More
Taking down chowkhats or frames with shutters (without taking off shutters from the frames exc 1.5 sq. m but n exc 4 sq. m each
9
-
-
... More
S&F anodised aluminium extruded sections as in frame for doors, windows, ventillators, partions including joining cleat for fixing etc complete all as directed powder coated
92
-
-
... More
S&F anodised aluminium sections (powder coated)for door shutters (aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprane packing, extruded anodised aluminium handle 2 Nos in each door shutter and 04 Nos hinges each shutter as per CE(AF) Gandi Nagar Zone Drg No CEAA/TD/63.
38
-
-
... More
S&F 4mm thick figured glass pin head type and glazing with oil putty or aluminium beads and rubber in squares exc 0.50 Sqmtr each pane complete all as specified and directed by Engr-in-charge.
31
-
-
... More
M & L in repair 12mm Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed suitably .
15.5
-
-
... More
S&F aluminium (extruded section body) door closure hydraulically regulated designation No 3, universal type suitable for door shutters of 851 to 1000mm in width
6
-
-
... More
M&L for rendering 10mm thick on stone / concrete block masonry surfaces of any description in cement mortar (1:6) is to be finished even and smooth (without using extra lime or cement) complete all as specified and directed.
46
-
-
... More
M&L for preparation of newly plastered of wall surfaces and applying two coat of oil emulsion distemper over a coat of cement primer in different tints in sigma / camouflaging pattern as approved complete all as specified.
46
-
-
... More
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
329.81
-
-
... More
M&L for 25mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination fixed with screws to Aluminium frame work as directed and specified by Engineer-in-charge.
75
-
-
... More
M&L for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
17.49
-
-
... More
M&L Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
11
-
-
... More
M & L Aluminium alloy, anodised, sliding door bolt (200 MM) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
6
-
-
... More
M & L Aluminium flush bolt, type 2, anodised and fixed flush. complete all as specified and directed.
3
-
-
... More
M & L Sheet glass, ordinary quality 3mm thick and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and directed.
6
-
-
... More
Pre-cast cement concrete block (Type C1 1:3:6 with 20mm graded aggregate) masonry with solid blocks, exc. 10 cm in width and setting in mortar complete all as specified and directed.
2.5
-
-
... More
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
2.5
-
-
... More
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
2
-
-
... More
M&L Concrete in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like in type B1 1:2:4 (20mm graded stone aggregate) complete all as specified and directed.
0.5
-
-
... More
M&l for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
25
-
-
... More
M&L for Granite (black/green/imperial red) of any type machine cut as in shelves/steps/counter tops, 20mm thick, set and jointed in cement slurry over & including screed of 15mm thick /rendering in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite as specified and directed by Engineer-in-Charge.
5
-
-
... More
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
2.5
-
-
... More
M&L for white wash two coats including surface preparation on new surface on wall complete all as specified and directed.
2.5
-
-
... More
M&L for PCC (1:4:8) type D2 (using 40mm) graded stone aggregate) as in foundation etc complete all as specified and directed.
1
-
-
... More
Formwork (rough finished) on flat surfaces of foundations, footings, bases of columns, raft and faft beams, sides and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter complete all as specified and directed.
4
-
-
... More
M&L for reinforced cement concrete RCC 1:2:4 type B1 (Nominal mix) (using 20mm graded stone aggregate) as in foundations, footings, plinth beams, bases for columns & mass concrete complete all as specified and directed.
1
-
-
... More
M&L for providing RCC 1:2:4 type B1 (Nominal mix) (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed. Note for item No 18.00 & 19.00 : Reinforcement to be measured separately.
1
-
-
... More
M&L for Mild steel TMT bars over 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
60
-
-
... More
M&L for Mild steel TMT bars 6mm dia and over upto and including 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
30
-
-
... More
M&L for Mild steel TMT bars 5 to 10mm dia in stirrups, spacers and binders, cut to Kg length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed.
30
-
-
... More
M&L brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
7
-
-
... More
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
50
-
-
... More
M&L for new steel surfaces preparation, priming with redoxide and painting with two coat synthetic enamel paint complete all as specified and directed.
100
-
-
... More
M&L for framed work as in doors or gates of angle, rectangular hollow section or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing and necessary welding as required complete all as specified and directed.
1504
-
-
Evaluation Notes How It Works ?