Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date23 Dec 2024
Closing Date11 Jan 2025
Tender Amount₹ 47,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
7.5 HP

2

-

-

... More
supply & fix of following Items against Item No 1.00 above suitable for 30/25 HP capacity centrifugal pump sets.

-

-

-

... More
CI Impeller

3

-

-

... More
Casing Ring

3

-

-

... More
Impeller ring brass nut

3

-

-

... More
Impeller key

3

-

-

... More
Coupling key

3

-

-

... More
Coupling rubber bushes/ Tyre coupling

3

-

-

... More
Shaft sleeve (Steel)

3

-

-

... More
Ball Bearing

6

-

-

... More
Brass Bush

6

-

-

... More
MS coupling (Beam, Jaw, Gear any type for both Pump and motor)

3

-

-

... More
Gland cap CI

3

-

-

... More
Gland bolt/ nut

12

-

-

... More
supply & fix of following Items against Item No 1.00 above suitable for 20/15/12.5 HP capacity centrifugal pump sets.

-

-

-

... More
CI Impeller

4

-

-

... More
Casing Ring

4

-

-

... More
Impeller ring brass nut

4

-

-

... More
Impeller key

4

-

-

... More
Coupling key

4

-

-

... More
Coupling rubber bushes/ Tyre coupling

4

-

-

... More
Shaft sleeve (Steel)

4

-

-

... More
Ball Bearing

8

-

-

... More
Brass Bush

8

-

-

... More
MS coupling (Beam, Jaw, Gear any type for both Pump and motor)

2

-

-

... More
Gland cap CI

3

-

-

... More
Gland bolt/ nut

12

-

-

... More
supply & fix of following Items against Item No 1.00 above suitable for 7.5 HP capacity centrifugal pump sets.

-

-

-

... More
CI Impeller

2

-

-

... More
Casing Ring

2

-

-

... More
Impeller ring brass nut

2

-

-

... More
Impeller key

2

-

-

... More
Coupling key

2

-

-

... More
Coupling rubber bushes/ Tyre coupling

2

-

-

... More
Shaft sleeve (Steel)

2

-

-

... More
Ball Bearing

4

-

-

... More
Brass Bush

4

-

-

... More
MS coupling (Beam, Jaw, Gear any type for both Pump and motor)

2

-

-

... More
Gland cap CI

2

-

-

... More
Gland bolt/ nut

8

-

-

... More
Taking down existing motor/pump from base plate after disconnecting the electrical connection and transporting to & from workshop for cutting (i.e machining, work, welding, grinding, turning & polishing, lathe work, filler work etc.) and taking burn out copper winding complete and cleaning properly. Rewinding the motor with same gauge and same turn ratio for proper RPM, best quality copper enamelled winding wire and packing properly with packing materials, varnishings, drying & replacing wornout bearing/terminal plate, reassembling, fixing in original position, testing & commissioning complete of following sizes all as directed by Engineer-in-charge :- Note : Supply only bearings and terminal plates will be measured and paid separetely under respective item of this schedule

-

-

-

... More
180 HP

1

-

-

... More
100 HP

1

-

-

... More
75/70/60 HP

1

-

-

1

-

-

2

-

-

... More
20/15 HP

2

-

-

... More
12.5/10 HP

1

-

-

... More
7.5 HP

2

-

-

... More
Supply and fix in repairs motor cooling fan of same size as existing suitable for motor including all fiiting,fixtures,etc as directed by Engineer-in-charge as following : -

-

-

-

... More
180/100 HP

2

-

-

... More
75/70/60 HP

2

-

-

... More
30/25/20 HP

2

-

-

... More
15/12.5 HP

3

-

-

... More
7.5/05 HP

3

-

-

... More
03/01 HP

2

-

-

... More
Lifting of electric motor from existing position after disconnection of all electrical connection for renewal of U/S bearing and applying grease after removal of old grease and re-installing at site where directed after refilling new grease and reconnecting all electrical connection and testing complete. Note : (a) Necessary payment for bearing shall be measured and paid separately under relevant items. (b) Quoted rate deemed to include cost of grease as per site. (c) The contractor shall lift the motors as directed by the Engineer-in-charge for normal servicing.

-

-

-

... More
10 to 60 HP

11

-

-

... More
75/70/60 HP

4

-

-

... More
S&F front / rear ends bearing of same size as existing suitable for motor incl all fiiting,fixtures,etc (including taking out motor if not in repair) as directed by Engineer-in-charge as following : -

-

-

-

... More
180 HP

4

-

-

... More
100 HP

2

-

-

... More
75/70/60 HP

4

-

-

... More
30/25 HP

4

-

-

... More
20/15 HP

4

-

-

... More
12.5/10 HP

4

-

-

... More
7.5/05 HP

4

-

-

... More
03/02/01 HP

4

-

-

... More
Taking down mono block pump set, dismantling and taking out burnout copper winding wires after opening the motor (i.e machining,work, welding, grinding, turning & polishing, lathe work, filler work etc.) & cutting & cleaning complete with proper cleaning solution and rewinding the motor with appropriate gauge & best quality copper enamelled wire with packing material, varnishing complete and testing & commissioning for following capacity complete all as directed by Engineer-in-charge. Note :- The other spare parts will be measured and paid separately under relevent items of Sch 'A'

-

-

-

... More
15/12.5 HP

3

-

-

... More
7.5/05 HP

2

-

-

... More
03/02 HP

2

-

-

... More
1.5/01 HP

2

-

-

... More
Supply & fix against Item No. 9.00 above the following spares parts suitable for 15/12.5 HP Pump Set 3 Phase capacity monoblock pump sets complete all as directed by Engineer-in-charge.

-

-

-

... More
CI Impeller

2

-

-

... More
Impeller nut GM

2

-

-

... More
key for Impeller MS

2

-

-

... More
Front bearing

2

-

-

... More
CI front inner cap.

2

-

-

... More
CI rear inner cap.

2

-

-

... More
Rear bearing

2

-

-

... More
CI rear outer cap.

2

-

-

... More
Terminal board bakelite

2

-

-

... More
Supply & fix against Item No 9.00 above the following spares parts suitable for 7.5/05/03/2/1/1.5 HP Pump Set 3 Phase capacity monoblock pump sets complete all as directed by Engineer-in-charge.

-

-

-

... More
CI Impeller

4

-

-

... More
Impeller nut GM

5

-

-

... More
key for Impeller MS

5

-

-

... More
Front bearing

5

-

-

... More
CI front inner cap.

5

-

-

... More
CI rear inner cap.

5

-

-

... More
Rear bearing

5

-

-

... More
CI rear outer cap.

5

-

-

... More
Terminal board bakelite

5

-

-

... More
S&F pump gland plate fitting of suitable size complete all as per specified and directed by Engineer-in-charge.

5

-

-

... More
S&F gland packing of pump of suitable size complete all as per specified and directed by Engineer-in-charge.

40

-

-

... More
S & F in repair contactor, 3 phase AC 440 volt of following capacity complete all as specified & directed by Engineer-in-charge :-

-

-

-

... More
18 Amps

2

-

-

... More
25 Amps

3

-

-

... More
32 Amps

5

-

-

... More
40 Amps

5

-

-

... More
70 Amps

4

-

-

... More
95 Amps

3

-

-

... More
115 Amps

4

-

-

... More
185 Amps

4

-

-

... More
225 Amps

2

-

-

... More
S&F in repair of DOL starter suitable size of motors 05/03/01 HP and pumps including indicating push button etc.complete with necessary copper wiring as required for connection complete all as per specified and directed by Engineer-in-charge.

4

-

-

... More
Supply and fix single phase preventor suitable for 3 phase 415 V motor of any make any size complete all as per specified and directed by Engineer-in-charge.

6

-

-

... More
S&F in replacement of over load relay complete all same as per existing capacity for the following :-

-

-

-

... More
7.5 HP

2

-

-

... More
10 to 15 HP

3

-

-

... More
20 to 30 HP

3

-

-

... More
60 to 75 HP

2

-

-

... More
S&F Electronic motor protection relay having overload/phase loss /locked rotor/phase revesal/Current unbalance/ short circuit/under current /earth fault protection complete all same as per existing capacity for the following:-

-

-

-

... More
100 HP

2

-

-

... More
180 HP

2

-

-

... More
S&F Electronic/block star delta timer (0-60 Second) complete all same as per existing capacity complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
S&F Add ON Block 1 NO+ 1 NC complete all same as per existing capacity complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
S&F in repair Push button for start & stop operation of Motor starter complete all same as per existing capacity complete all as specified and directed by Engineer-in-charge.

3

-

-

... More
Taking down of RYB phase indicator and repair/renewal of RYB phase indicator of any size and any type of LT Panel complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
M&L Repair/replacement of LT panel board complete by replacing following unserviceable items/parts like selector switch, busbar, cable lugs, voltmeter, ammeter, panel wiring,etc complete (if required with necessary copper wiring, lugs,etc complete to make item functional ) complete all as per specified and directed by Engineer-in-charge.

-

-

-

... More
Digital Voltmeter 0-500 V

7

-

-

... More
Digital Ammeter 0-200 A

7

-

-

... More
Ammeter CT type 0-300 A

5

-

-

... More
Selector switch as per existing

10

-

-

... More
Aluminium Busbar as per existing

6

-

-

... More
Cable lugs as per existing

10

-

-

... More
Supply and fixing the following items complete all as per specified and directed by Engineer-in-charge :-

-

-

-

... More
MCCB, 63 Amps, four pole,16 KA, 415 volt Note :- Ics = 100%Icu

4

-

-

... More
MCCB, 100 Amps, four pole,16 KA, 415 volt Note :- Ics = 100%Icu

2

-

-

... More
MCCB 125 Amps, 4 pole, 16 KA, 415 volt Note :- Ics = 100%Icu

2

-

-

... More
MCCB, 160 Amps, four pole, 16 KA, 415 volt Note :- Ics= 100%Icu

2

-

-

... More
MCCB, 200 Amps, four pole, 25 KA, 415 volt Note :- Ics = 100%Icu

2

-

-

... More
MCCB, 250 Amps, four pole, 25 KA, 415 volt Note :- Ics = 100%Icu

2

-

-

... More
MCCB, 400 Amps, four pole, 36 KA, 415 volt Note :- Ics = 100%Icu

2

-

-

... More
MCB SP, 6 to 32 Amps, Type 'C', 10 KA, 240 volt

5

-

-

... More
MCB SPN, 32 Amps, 240 volt

5

-

-

... More
Supply, laying and fixing or passing through pipes, ducts or laid under floor of through walls etc jointing and testing LT XLPE insulated, PVC sheathed electric cable 1100 volt grade heavy duty ISI marked with copper conductor and over all served with an outer sheath of PVC from panel to motor including providing copper lugs as per site requirement along with including taking down old cable complete all of following sizes complete all as per specified and directed by Engineer-in-charge :-

-

-

-

... More
70 Sqmm single core.

250

-

-

... More
50 Sqmm single core.

250

-

-

... More
35 Sqmm single core.

150

-

-

... More
25 Sqmm single core.

230

-

-

... More
16 Sqmm single core.

180

-

-

... More
10 Sqmm single core.

120

-

-

... More
Supply, laying XLPE insulated PVC FRLS, screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor including taking out old un-serviceable cable of following sizes as specified and directed by Engineer-in-charge :-

-

-

-

... More
10 Sqmm 4 core.

150

-

-

... More
16 Sqmm 4 core.

150

-

-

... More
50 Sqmm 3.5 core.

120

-

-

... More
Taking out the submersible pump set of 17.5/20/33 HP capacity from deep bore well with connected cable and column pipes of 3M length with flange end 3"/2'' dia approx 40 to 45 Nos per bore well and disconnecting the cable for removing the submersible pump set for carrying out necessary repairs complete all as per specified and directed by Engineer-in-charge.

7

-

-

... More
Lowering of submersible pump set 17.5/20/33 HP in bore well with connected cable & column pipes, re-assembling column pipe of 3M long with flange ends 3"/2'' dia appx 40 to 45 Nos and testing and commissioning of pump set after repairs including rectification of any leakage to the entire satisfaction of complete all as per specified and directed by Engineer-in-charge.

7

-

-

... More
Repairs to submersible pumping set 17.5/20/33 HP by dismantling pumps and motor carrying out required repairs to pump by machines ie grinding/polishing reassembling after renewal of all worn out spare parts, cleaning and refixing with motors with required coupling etc complete testing complete all as per specified and directed by Engineer-in-charge. Note :- Rewinding of motor & renewal of parts will be measued & paid separately

4

-

-

... More
Rewinding of AC 3 Phase induction motor of 17.5/20/33 HP capacity (Submersible motor) by cutting of burnt out winding, cleaning of starter slots, cleaning, bleaching of motor and rewinding with appropriate gauge of PVC insulated copper winding wire complete including all required parts complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
Supply & fix against Item No 29.00 above the following spares parts of pump of submersible pump set suitable for 17.5/20/33 HP pump :-

-

-

-

... More
Impeller

45

-

-

... More
Stage bowl

45

-

-

... More
Bowl fixing steel bolt and nut with washer

6

-

-

... More
Bearing sleeve

6

-

-

... More
Shaft nut with washers

6

-

-

... More
Bearing bush suitable

6

-

-

... More
Neck ring suitable

6

-

-

... More
Casing wear ring

6

-

-

... More
Strainer

6

-

-

... More
Shaft seal

6

-

-

... More
Stage gasket

6

-

-

... More
Supply & fix against Item No 29.00 above the following parts for motor of submersible pump set suitable for 17.5/20/33 HP motor :-

-

-

-

... More
Thrust bearing plate

6

-

-

... More
Assembly for coupling sleeve

6

-

-

... More
Winding protector set

6

-

-

... More
Motor bearing bush

6

-

-

... More
Drain plug suitable

6

-

-

... More
Sand Guard

6

-

-

... More
Key for thrust plate

6

-

-

... More
Renewal of Heavy duty terminal plate made of bakelite suitable for electric motor of capacity 60 to 180 HP with brass nuts of suitable size best quality as approved by GE complete all as specified and directed.

4

-

-

... More
Renewal of Terminal plate cover made of CI for fixing over the terminal plate with cover for 60 to 180 HP electric motor best quality as approved by GE complete all as specified and directed.

4

-

-

... More
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete as specifed and directed by Engineer-in- charge.

40

-

-

... More
Supply and fixing Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body having ISI certified as specified and directed by Engineer-in- charge.

40

-

-

... More
Supply and fixing in repair LED building security light fitting 35 Watt ,230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with electronic driver including thermal management in multiple optics complete with IP 65/66 protection complete with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 1 Sqmm from ceiling rose to fitting including taking down old unserviceable LED light complete all as directed by Engineer-in-Charge.

20

-

-

... More
S & F in repair GI pipe bracket medium grade of 40 mm dia for building security light,clamps made of FI 40 mm x 6 mm Incl nuts,bolts & washers,painting complete as specified.

20

-

-

... More
Supply, install, testing and commissioning of LT motor control panel AC 415 V, 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 52, suitable for indoor use, with bottom cable entry with suitable cable glands structure made of 2.00 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs , with sloping canopy at top, double hinged doors at front and back with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated with 100A electrical grade copper bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved, internal wiring all including the following incoming complete all as specified and directed :- (a) MCCB 4 P 100 Amps rating, 25 KA breaking capacity- 01 No.(Incoming) (b) MCCB TP 63 Amps rating, 16 KA -2 nos, (c) Fully automatic star delta starter, Motor protection relay, suitable for 20/25 HP electric driven submersible pump set to be mounted in panel comprising of all types of contactors, Motor Protection Relay, thermal over load range with in built Earth Fault protection, timer and phase reversal, ON and OFF switch respective starters/motors -02 Nos (d) Ampere meter & Volt meter digital type with suitable CTs & selector switch - 1 No each, (e) MCB SP 6 Amps -03 Nos, (f) Indicator lamp LED type - 3 Nos

2

-

-

... More
S&F in repair Electrical insulation rubber mat of class A/ anti skid / shock proof ISI certified having size of (1 meter x 2 meter x 10 mm) complete all as per specified and directed by Engineer-in-charge.

25

-

-

... More
S&F rubber insertion gasket suitable for 3"/2" dia flange complete all as per specified and directed by Engineer-in-charge.

100

-

-

... More
S&F 1/2" MS bolt 2" long full threaded with 2 washers and nut complete all as per specified and directed by Engineer-in-charge.

85

-

-

... More
M&L in replacement of GI column pipe heavy grade 3M long 3" bore with welded heavy duty flanges at both ends including a coat of anticorrosive paint complete all as per specified and directed by Engineer-in-charge.

60

-

-

... More
S&F in repair submersible cable PVC insulated and PVC sheathed industrial 1100 Volts grade multistranded copper conductor of size 10 Sqmm flat 3 Core complete all as per specified and directed by Engineer-in-charge.

500

-

-

... More
M&L for painting of following capacity monoblock/centrifugal with foundation (base plate to be scratched and painted) painting (all as per colour code specified) by one coat of synthetic enameled paint after cleaning and preparing surface for painting and testing complete at site on full load all as directed by Engineer-in-charge.

-

-

-

... More
7.5/05/03/01 HP

5

-

-

... More
12.5/15/20/25/30 HP

10

-

-

... More
60/70/75 HP

4

-

-

... More
100/180 HP

5

-

-

... More
M & L for bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground levl connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection and testing including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on including taking down old unserviceable earthing complete all as specified and directed by Engg-in-Charge. NOTE:- (i) GI earth strip and protection pipe beyond 7.5m will be measured and paid separately) (ii) Excavation & earth work in any type of soil including removing of surplus material upto 100M (iii) PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. (iv) Main earthing strip from earth electrode to test point upto 7.5 mtr. (v) Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. (vi) GI protection pipe of size 40 mm bore light grade 7.5m.

11

-

-

... More
M&L for main earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in pipe and fixed to motor/Panel or any other equipment with galvanised strip 25x4 mm including taking down existing galvanised strip of any description complete all as per specified and directed by Engineer-in-charge. Note :- Earth continuity conductor beyond 7.5m length shall only measured under this item.

75

-

-

... More
M&L for preparation of old brokage door by applying welding, painted surface of steel / iron of LT motor starter panel of any capacity by scaping with emery/sand paper,brushing, cleaning, staining grease/oily spots with thinner and applying two coats of superior quality synthetic enamel paint with spray machine over a coat of primer complete all as per specified and directed by Engineer-in-charge.

8

-

-

... More
M&L for preparation of old painted suction & delivery pipeline of any capacity by scaping near pumphouse with emery/sand paper,brushing, cleaning, staining grease/oily spots with thinner and applying two coats of superior quality synthetic enamel paint complete all as per specified and directed by Engineer-in-charge.

240

-

-

... More
Taking up carefully from trenches/walls/pillar GI water mains including all fittings of following sizes complete all as per specified and directed by Engineer-in-charge :-

-

-

-

... More
20 mm bore.

84

-

-

... More
25 mm bore.

204

-

-

... More
40 mm bore.

114

-

-

... More
50 mm bore.

126

-

-

... More
Refixing of old steel water tubing and connections in new or old position (wall/floor/ceilling/trecheh etc) of following sizes complete all as per specified and directed by Engineer-in-charge :-

-

-

-

... More
20 mm bore.

24

-

-

... More
25 mm bore.

24

-

-

... More
40 mm bore.

24

-

-

... More
50 mm bore.

24

-

-

... More
Supply and fix laid in trenches steel water tubing galvanised medium grade with all fittings of following sizes complete all as per specified and directed by Engineer-in-charge :-

-

-

-

... More
25 mm bore.

120

-

-

... More
40 mm bore.

66

-

-

... More
50 mm bore.

66

-

-

... More
Supply and fix complete to walls / ceilings or laid in floors steel water tubing galvanised medium grade with all fittings of following sizes complete all as per specified and directed by Engineer-in-charge :-

-

-

-

... More
20 mm bore.

60

-

-

... More
25 mm bore.

60

-

-

... More
40 mm bore.

24

-

-

... More
50 mm bore.

36

-

-

... More
M & L for cutting existing GI tubing for alteration or additions of sizes including screwing existing GI tubing for tapping & making new connections etc of following sizes complete all as per specified and directed by Engineer-in-charge :-

-

-

-

... More
20 mm bore.

4

-

-

... More
25 mm bore.

4

-

-

... More
40 mm bore.

4

-

-

... More
50 mm bore.

4

-

-

... More
S&F in repairs globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the follwing sizes with ISI marked and as per IS 14846 complete all as per specified and directed by Engineer-in-charge :-

-

-

-

... More
20 mm bore.

5

-

-

... More
25 mm bore.

10

-

-

... More
40 mm bore.

3

-

-

... More
50 mm bore.

3

-

-

... More
Taking up carefully from trenches/walls/pillar CI/DI water mains incl all fittings with spigot and socket ends including joint/rubber gaskets/lead wool/tyton joint for the following sizes:-

-

-

-

... More
100 mm bore.

666

-

-

... More
350 mm bore.

33

-

-

... More
Relaying, realigning the DI/CI pipe line with spigot and socket ends (in any length) on wall/pillars/trenches with necessary fitments (tyton joint/rubber gasket,etc) for complete assembly of following sizes complete in all respect all as specified & directed by Engineer-in-charge.

-

-

-

... More
100 mm bore.

66

-

-

... More
350 mm bore.

33

-

-

... More
Supply and laying ductile iron pipe with internal cement mortar lining and external zink pipes with class of pipe K-9 of following size complete in all respect all as specified & directed by Engineer-in-charge. :-

-

-

-

... More
100 mm bore.

600

-

-

... More
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in deep but n exc 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in any type of soil complete all as per specified and directed by Engineer-in-charge.

80

-

-

... More
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in deep but n exc 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in soft/disintegrated rock complete all as per specified and directed by Engineer-in-charge.

65

-

-

... More
Returning filling in including spreading levelling watering and well ramming in layers of soil n.exc 25 cm complete all as per specified and directed by Engineer-in-charge.

72

-

-

... More
Returning filling in including spreading levelling watering and well ramming in layers of rock n.exc 25 cm in soil complete all as per specified and directed by Engineer-in-charge.

56

-

-

... More
Removing of excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point of soil complete all as per specified and directed by Engineer-in-charge.

8

-

-

... More
Removing of excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point of soft / disintegrated rock complete all as per specified and directed by Engineer-in-charge.

9

-

-

... More
Taking down Sluice valve of any size complete all as per specified and directed by Engineer-in-charge.

4

-

-

... More
S&F Sluice valve PN-1.6 with SS spindle and wedge nut ISI maked (IS-14846 : 2000) complete with iron wheel of following sizes complete all as per specified and directed by Engineer-in-charge :- Note :- Rate includes neccesary arrangements and cutting the pipe of required dimension with attachments for fitting the sluice valve.

-

-

-

... More
80 mm bore size.

2

-

-

... More
100 mm bore size.

2

-

-

... More
Supply and fix in replacement cast iron non return (reflux) valve size 100mm bore both flanged ends in swing type design as per IS 5312 Part-1, PN-1.0, complete all as per specified and directed by Engineer-in-charge.

2

-

-

... More
Supply, fixing and testing, cast iron air release valve size of 80 mm bore with two air outlet and fixing in existing CI/ DI water supply mains complete including necessary cutting/ drilling inserting tee, nuts, bolts etc including taking out old unserviceable air release valve complete all as per specified and directed by Engineer-in-charge.

2

-

-

... More
Supplying, fixing and testing of CI/DI pipe fitting for spigot socketed pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing/ decreasing or double socket etc). Tee pieces, single branch, “Y” junction, double branch, cross (all sockets or socket and spigot), collars, End caps and plugs, for pipe upto 400mm bore complete all as per specified and directed by Engineer-in-charge. Note:- Rate of cutting existing pipe for insertion of the fitting is included in the quoted rate.

250

-

-

... More
M&L for cutting of DI water mains raising pipeline 350 mm in existing position for branch connection including DI Tee of size of (350 x 350 x 100 mm) rubber coupling , nuts bolts of suitable size including necessary accessories complete all as per specified and directed by Engineer-in-charge.

1

-

-

... More
Labour only for attending water supply complaints and rectifying the faults viz no water supply, water leakage, air lock, low pressure, over flow etc including all necessary patty items like rubber gasket, grease, screws, GI tees, bends, elbow etc and tool required including excavation in any type of strata as per site requirement and making arrangement of electric/diesel pump/JCB/manual additional labour by caulking with pig lead/ lead wool/ tyton joint of size 20mm bore to 100mm bore complete all as specified and directed by Engineer-in-charge.

500

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.