Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,45,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_675961_1Bid Award Id
ViewTender No
84229/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S&F in repair of synthetic rubberised gaskets 4mm thick for top cover and other joints for transformer capacity 25 KVA to 75 KVA ,11/0.433 KV complete all as specified & directed by Engineer-in - Charge.
1
-
-
S&F in repair of synthetic rubberised gaskets 4mm thick for top cover and other joints for transformer capacity 160 KVA to 630 KVA ,11/0.433 KV complete all as specified & directed by Engineer-in - Charge.
4
-
-
M&L for taking out unserviceable core and limb and HV/LV winding of transformer and taking out burnt copper winding wire cleaning carefully and rewinding the same with new superior quality 99.99% pure copper enamelled wire as per existing gauge including insulating material for transformer 25 KVA to 630 KVA complete all as specified & directed by Engineer-in - Charge.
550
-
-
Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV complete all as specified & directed by Engineer-in - Charge.
Note : For any capacity of Transformer
20000
-
-
Supply only transformer oil for topping up of transformers any capacity all as conforming to IS - 335 at different transformers & different locations complete all as specified & directed by Engineer-in - Charge.
Note:- (i) The dielectric strength of the transformer oil must be 45 KV r.m.s (min). (ii) Test certificate in respect of the same to be submitted by the contractor duly signed by the Engr-In-Charge.
3000
-
-
M&L in repair of unserviceable HT brass stem with nuts, washers of transformer 63 KVA to 630 KVA complete all as specified & directed by Engineer-in - Charge.
20
-
-
M&L in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 25 KVA to 63 KVA complete all as specified & directed by Engineer-in - Charge.
10
-
-
M&L in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 100KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
10
-
-
M&L in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 315KVA to 630 KVA complete all as specified & directed by Engineer-in - Charge.
10
-
-
M&Lin repair of unserviceable breather assembly with new silica gel of transformer 11/0.433 KV of capacity 25 KVA to 100 KVA complete all as specified & directed by Engineer-in - Charge.
20
-
-
M&L in repair of unserviceable breather assembly with silica gel of transformer 11/0.433 KV of capacity 160 KVA to 630 KVA complete all as specified & directed by Engineer-in - Charge.
20
-
-
S&F in repair of winding tempreture indication gauge anlog type complete suitable for transformer 11/.433 KV, 100 KVA up to 630 KVA complete all as specified & directed by Engineer-in - Charge.
5
-
-
S&F in repair of porcelain transformer bushing 11 KV suitable for transformer 63 KVA to 100 KVA complete all as specified & directed by Engineer-in - Charge.
12
-
-
S&F in repair of porcelain transformer bushing 11 KV suitable for transformer 160 to 630 KVA complete all as specified & directed by Engineer-in - Charge.
10
-
-
S&F in repair of porcelain transformer bushing 433 volts suitable for transformer up to 100 KVA complete all as specified & directed by Engineer-in - Charge.
10
-
-
S&F in repair of porcelain transformer bushing 433 volts suitable for transformer 160 KVA upto 630KVA complete all as specified & directed by Engineer-in - Charge.
10
-
-
S&F in repair tap changer suitable for 11/440 KV transformer of capacity 63 to 630 KVA complete all as specified & directed by Engineer-in - Charge.
2
-
-
S & F in repair dimmer suitable for voltage stablizer 50 kva complete all as specified and directed by Engineer-in-Charge. Make:- Digitec or equivalent make as approved by GE.
3
-
-
S & F in repair dimmer suitable for voltage stablizer 75 to 100 KVA complete all as specified and directed by Engineer-in-Charge.
3
-
-
S & F in repair servo motor 3 Kg / Sqcm suitable for voltage stablizer 50/75 KVA (3x25) complete all as specified and directed by Engineer-in-Charge.
6
-
-
S&F in repair PCB, including carben bush, limit swith, push button etc suitable for voltage stablizer 50/75 KVA (3x25) complete all as specified and directed by Engineer-in-Charge.
3
-
-
Supply, Jointing and testing indoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 50 Sqmm to 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as specified and directed by Engineer-in-Charge.
10
-
-
All as per item No. 25 above but here-in-before 120 Sqmm to 185 Sqmm 3 core
8
-
-
Supply, Jointing and testing outdoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as specified and directed by Engineer-in-Charge.
15
-
-
All as per item No. 27 above but here in before 120 Sqmm to 185 Sqmm 3 core.
10
-
-
Supply jointing and testing straight through heat shrinkable joint kit 11 KV unearthed grade suitable for size 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as specified and directed by Engineer-in-Charge.
20
-
-
All as per item No. 29 above but here in before 120 Sqmm to 185 Sqmm 3 core.
10
-
-
Re-stringing and re-connection of ACSR of any size duly binded with insulators, jumpers etc.(fixed on 9/11mtr poles) complete all as specified and directed by Engineer-in-Charge. Note : (i) The above work includes cleaning pruning of tree branches falling around the conductors (ii) One length shall be measured for complete span of 3/4/5/6 conductors & GI wire.
100
-
-
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (12 Insulators Vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified and directed by Engineer-in-Charge.
6
-
-
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (09 Insulators Vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified and directed by Engineer-in-Charge.
20
-
-
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (09 Insulators Horizental type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. Note :- stack for fixing with poles shall be measure and paid separately
6
-
-
S&F in repair, pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed by Engineer-in-Charge.
50
-
-
S&F in repair, disc type insulator, porcelain, vitreous with hardware, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for 11000 volts grade complete all as specified and directed by Engineer-in-Charge.
30
-
-
Supply & fix in repair insulator, disc type,porcelain series in three with hardware, vitreous,white, brown or green of suitable size socket type, single disc assembly for tension clamp for conductor working pressure 33000 Volt complete all as specified and directed by Engineer-in-Charge.
20
-
-
Supply & fix in repair insulator, pin type,porcelain, vitreous,white, brown or green of suitable size with clamp for conductor working pressure 33000 Volt complete all as specified and directed by Engineer-in-Charge.
50
-
-
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 95 sqmm, 3 core including taking down unserviceable complete all as specified and directed by Engineer-in-Charge.
550
-
-
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 120 sqmm, 3 core including taking down unserviceable complete all as specified and directed by Engineer-in-Charge.
480
-
-
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 185 sqmm, 3 core including taking down unserviceable complete all as specified and directed by Engineer-in-Charge.
350
-
-
Supply and lay cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 33000 Volt grade with stranded aluminium conductor of size 185 Sqmm 3.0 Core complete all as specified and directed by Engineer-in-Charge.
100
-
-
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/disintegrated rock complete all as specified and directed by Engineer-in-Charge.
180
-
-
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified and directed by Engineer-in-Charge.
2
-
-
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
365
-
-
Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/Disintegrated rock in layers complete all as specified and directed by Engineer-in-Charge.
96
-
-
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/loose soil complete all as specified and directed by Engineer-in-Charge.
280
-
-
Removing excavated Soft/Disintegrated rock to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
136
-
-
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as specified and directed by Engineer-in-Charge. Note :- For the purpose of payment only punned thickness will be measured
102
-
-
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified and directed by Engineer-in-Charge.
315
-
-
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-Charge.
50
-
-
S&F in repair GI pipe light grade of dia 80 mm laying in road and along with poles for cable protection complete all as specified and directed by Engineer-in-Charge.
50
-
-
Dismantling & Taking down old climbing device and fixing of new anti-climbing device, comprising 2.24 mm dia galvanised steel-2 strand barbed wire with 2.00 mm dia barbs wrapped spirally round poles to a length of 0.5 to 1.0 mtr clamped and properly secured or as orded complete all as specified and directed by Engineer-in-Charge. Note :- clamps measured seperatly all as specified
0.5
-
-
Supply and fixing in repair Expulsion Fuses with fues barel, single pole for HT 11 KV station class type above 25 & upto 50 Amp complete all as specified and directed by Engineer-in-Charge.
2
-
-
Disconnecting and taking out voltmeter of any description and supply, fixing connecting, testing and commissioing of digital electric voltmeter (0-500V) range with in built selector switch suitable for LT 415 Volts 50Hz AC supply panel board flush pattern, square type 96mm x 96mm with adopter including connected wiring with 1.5 Sqmm PVC cable complete all as specified and directed by Engineer-in-Charge.
4
-
-
Disconnecting and taking out Ampmeter of (0-250) amps and upto (0-400) amps rating of any description and supply, fixing connecting, testing and commissioing of digital electronic Ampmeter suitable as existing amp rating for suitable CT ratio and in built selector switch suitable for LT 415 Volts 50Hz AC supply panel board flush pattern, square type 96mmx96mm with adopter including connected wiring with 1.5 Sqmm PVC cable complete all as specified and directed by Engineer-in-Charge.
4
-
-
M & L for cement concrete (1:3:6) type C-2 using 40mm grade stone aggregate as in foundation of stay assembly struts or pole etc complete all as specified and directed by Engineer-in-Charge.
34
-
-
M & L for cement concrete (1:2:4) type B-1 using 20mm grade stone aggregate as in coping around poles including necessary form work finishing even and smoth with out using extra cement complete all as specified and directed by Engineer-in-Charge.
10
-
-
M & L for cement concrete (1:4:8) type D-2 using 40mm grade stone aggregate in foundation of PCC pole/struts as specified including necessary form work finishing even and smoth with out using extra cement complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L for painting tranformer complete by removing existing oil paint by scrapping and applying two coats of approved colour synthetic enamel paint (1st grade quality) over a coat of primer after preparation of surfaces including writing SM / MES numbers and date of oil tested etc. for the following capacity complete all as specified and directed by Engineer-in-Charge. :-
-
-
-
Transformer of capacity 25 KVA to 75 KVA, 11 KV/0.433 KV.
25
-
-
Transformer of capacity 100 KVA to 200 KVA, 11 KV/0.433 KV.
30
-
-
Transformer of capacity 250 to 630 KVA, 11 KV/0.433 KV.
15
-
-
Servicing the 11 KV GOD by cleaning the contact, disc/ pin insulator with CTC and applying the petroleum jelly at the contact point/ down rod links for smooth operation including replacing the rusted/ corroded bolts & nuts and defective insulator of GOD as required complete all as specified and directed by Engineer-in-Charge. Note :- Insulator shall be measured and paid under relevant items of this schedule.
40
-
-
Supply & fixing Male/ Moving contact (set of 3 Nos) complete all as specified and directed by Engineer-in-Charge.
40
-
-
Supply & fixing Female/ Fixed contact (set of 3 Nos) complete all as specified and directed by Engineer-in-Charge.
40
-
-
Dismantling, taking down and removing the old existing unsv non-functional/broken hinges of any description and in any postiion of existing feeder piller boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 100mm long medium weight mild steel but hines in position with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangments complete all as specified and directed by Engineer-in-Charge. Note : All Hinges fixed in one panel will be considred under one job only
40
-
-
Taking down or removing of rusted body part/panel door existing LT/HT Panel feeder pillar box of any size and shap and supply, fixing and febrication in existing, shap and size with and including 2 mm thick CRCA sheet and all jointing material such as nuts, bolts or washer and welding etc complete all as specified and directed by Engineer-in-Charge. NOTE : (i) The panel board repaired shall be made totally enclosed, weather proof/wemin proof for installing incoming/outgoing MCCB/Switch fuses/cable etc complete all as directed.
(ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, levelling and jointing etc. as directed to match & accommodate with the existing feeder pillar box/panel board. (iii) The external part of full panel shall be painted with two coat of synthetic enamled paint over a coat of red oxide primer.
(iv) The rates quoted by the contrqactor deemed to be with and including dismantling/taking out/removing carefully, any damaed part/portion of the feeder pillar box/panel board as directed.
28
-
-
Preparation of the old decorated existing external and internal steel surfaces for LT/HT feeder pillar boxes/panels/boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow stopping as required and applying tow coats of synthetic enameled paint (grey in colour) with using spray machine on old prepared surfaces complete all as specified and directed by Engineer-in-Charge.
35
-
-
Dismantling & taking down ACSR conductor, of any size, after taking necessary shut down, for 11 KV HT OH line, by loosening the binding wires, jumpers etc. for replacement of insulator / cross arms etc. complete all as specified and directed by Engineer-in-Charge.
2
-
-
Dismantling cross arms of MS channels or angle sections etc complete all as specified and directed by Engineer-in-Charge.
10
-
-
Supply fabricate, fixing structural mild steel RS joist, channel angle iron, flate iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clapms, eye hook and back plate etc fabricated from structural steel section inclduing nuts, bolts,washers, welding (Cold and Hot) drilling holes for bolts, bend to any shape or size as indicated and directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete complete all as specified and directed by Engineer-in-Charge.
8
-
-
Re-fixing of cross arms/clamps/nuts/bolts/washers etc. (as dismantled under item No. 68.00 above) on the refixed/new PCCC/RCC poles of any length complete all as specified and directed by Engineer-in-Charge.
2
-
-
S&F ACSR conductor of size, as required at site, duly binded with insulators, jumpers etc.(fixed on poles) complete all as specified and directed by Engineer-in-Charge.
1.5
-
-
Re-stringing and re-connection of ACSR (as dismantled under item Sl No - 67.00) duly binded with insulators, jumpers etc.(fixed on poles) complete all as specified and directed by Engineer-in-Charge.
0.5
-
-
Taking out existing broken/unserviceable stay assembly and supply and fixing new stay assembly complete with accessories and GI stay rod 20 mm dia 1900 mm long, stay wire 7/4 mm stranded galvanised including mild steel stay plate 300 mm X 300 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90 mm x140 mm clearance of hole 25.5 mm complete all as specified and shown in electrical plate No. 1 of SSR part–I complete all as specified and directed by Engineer-in-Charge. Note : Excavation and concrete to be measured separately under respective items.
20
-
-
Dismantling of 9/11 mtr long PCC/RCC/Steel tubular poles after breaking the foundation concrete including necessary excavation of earth, filling the hole with broken pieces of concrete and making good the disturbed area by filling excavated earth, obtained from the hole for new pole to be erected nearby area, to match with the surroudings complete all as specified and directed by Engineer-in-Charge.
20
-
-
Supply and fix Prestressed concrete pole 11.0 metres long,152mmx152mm at top and 152mm x 260 mm at bottom class-9 including necessory connection to over head conductor complete all as specified and directed by Engineer-in-Charge.
10
-
-
M &L steel tubular swaged poles and complete with cast iron / M.S base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 mtrs long) including painting with two coats of aluminium paint over a coat of red oxide metal primer complete all as specified and directed by Engineer-in-Charge.
10
-
-
Material and Labour for ZEBRA painting of PCC/steel poles 9/11 m long alongwith road upto 1.5 m height from ground level/PCC foundation with two coats of synthetic enamel paints in 30 cm height complete all as specified and directed by Engineer-in-Charge.
200
-
-
Material and labour for painting to steel tubular pole of HT/ LT over head line and all MS clamps, cross arm work on poles with one coat of superior aluminium paint including necessary preparation of surfaces and painting of alternate strip with black and blue for LT and Black and red for HT, synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/coping complete all as specified and directed by Engineer-in-Charge.
30
-
-
Material and labour for spreading levelling with 20 mm graded coarse aggregate / gravells laid approximately 75 mm thick layers near Feeder pillar/2/4 pole structure and plateform etc complete all as specified and directed by Engineer-in-Charge. Note : (i) Before spreading of gravells removing the grass and bushing and its roots growing around the 2/4 pole and plate form of transformer
(ii) Rates deems to be included under respective items
80
-
-
M & L in repair of GI wire (guard wire) of dia 4 mm minimum complete fixing below the HT /LT over head line counductor including fixing on height of 6 to 9 mtr above ground level in shape and size complete all as specified and directed by Engineer-in-Charge. Note :- Complete in all respect including the arrangement of tools requested to be carry for job.
3
-
-
Cuttting / trimming of tree branches in close proximity to over head lines to maintain a clearance of 1.5 meters from the over head line to nearby trees complete and removing/ throughing the cutting branches to distance not exceeding 50 m complete all as specified and directed by Engineer-in-Charge. Note :- Only effected area of over head conductor shall be measured as per running meter.
450
-
-
Supply and fixing feeder Piller Box outdoor type single door front openable in two half not less than 1.20mx1.20mx1.00m made out of 3.15 mm thick CRCA sheet podwer coated paint in heat process of sheet, supported on angle iron frame 50x50x6mm having legs 1.2,mtr long grouted in PCC upto 60cm, aluminium bus bar 03 Nos rated capacity 200A (HT) duly insulated 11000 Volt grade for phases supported on HT porcelain insulator , PCC foundation 1:2:4 complete all as specified and directed by Engineer-in-Charge.
7
-
-
M & L for bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 32 x 6 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing and including taking down old unserviceable earthing complete all as specified and directed by Engineer-in-Charge.
18
-
-
M&L for cable Jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 to185 Sqmm complete all as specified and as directed by Engineer-in-Charge.
4
-
-
M&L for cable Jointing kit for 33 KV (Earthed) grade cable for oudoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 to 185 Sqmm complete all as specified and as directed by Engineer-in-Charge
4
-
-
M&L for cable Jointing kit for 33 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L for cable earhing kit for 33 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 Sqmm complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L for finding cable fault with electronic fault detector in LT/HT UG cable of any size complete including earthwork and jointing cable complete all as specified and directed by Engineer-in-Charge.
10
-
-
Removing grass and bushes including its roots growing at Substation yard/around the platefarm of transformer/ two poe/4 pole structure and keep the sub station yard/ plate farm area neat and clean complete all as specified and directed by Engineer-in-Charge.
5250
-
-
Evaluation Notes How It Works ?