Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Pipes and Pipe Related Activities
Eprocure
Opening Date15 Sep 2020
Closing Date19 Oct 2020
Tender Amount₹ 15,65,234 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and for depth not exceeding 1.5m and getting out in hard rock by chiselling complete all as specified and as directed.

39.3

-

-

... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and for depth exceeding 1.5m but not exceeding 3.0m and getting out in hard rock by chiselling complete all as specified and as directed.

24.2

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick as in soil complete all as specified and as directed.

47.69

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick as in rocks complete all as specified and as directed.

49.83

-

-

... More
Removal of excavated material [soils] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.

54.61

-

-

... More
Removal of excavated material [rocks] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.

104.6

-

-

... More
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removing rubbish to out side MD land complete all as specified and as directed.

76

-

-

... More
M&L PCC 1:3:6 type C2 by using 40mm graded stone aggregate as in foundations filling mass concrete and surface channels of drain complete all as specified and directed.

4.65

-

-

... More
M & L walling of random rubble masonry,un coursed, well bonded ,bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.

60

-

-

... More
M & L walling of random rubble masonry,un coursed , well bonded ,bedded and solidly hearted built in cement mortar 1:6 except stone complete all as specified and directed.

16

-

-

... More
M & L PCC 1:3:6 type C-1 (20mm graded crushed stone aggregate) as in coping including necessary form work complete all as specified and as directed.

2

-

-

... More
Extra over stone walling for hammer dressing to face granite or trap stones with maximum depression on face from a straight edge held against the dressed surface not exceeding 40mm and dressing face beds and joints as specified of random rubble walling un-coursed or brought upto courses complete all as specified and as directed .

150

-

-

... More
M&L flush pointing in cement mortar (1:3) to random rubble masonry , un coursed complete all as specified and directed .

15

-

-

... More
Taking down chowkats or frames (without taking of shutters from the frames) area exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and as directed .

4

-

-

... More
Taking down chowkats or frames (without taking of shutters from the frames) area not exceeding 1.5 Sqm each complete all as specified and as directed.

6

-

-

... More
M&L rolled mild steel bands,straps,hold fasts ,MS frames for doors and similar works etc., conform to Fe-290 Gde E-165 complete all as specified and as directed.

80

-

-

... More
M&L 35mm thick factory made 2nd class HW glazed and skelton shutter and open rebated and prepared to receive glass, gauge etc (without sash bars), edges or framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I Section 8 Clause 8.24 (a) complete all as specified and as directed.

5.2

-

-

... More
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.

10

-

-

... More
S&F 35 mm thick second class hard wood factory made plain, framed, panelled shutters, with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and Style as per IS:1003 (Part-1), kiln seasoned and chemically pressure treated complete all as specified and as directed.

10

-

-

... More
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specifications complete all as directed .

18

-

-

... More
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and as directed.

8

-

-

... More
S&F 250 mm length aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed .

12

-

-

... More
S&F100mm size butt hinges, medium weight, cold rolled mild steel, complete all as specified and as directed.

24

-

-

... More
S&F 150 mm size aluminium anodised handles, caste type, complete all as specified and as directed.

12

-

-

... More
S&F 200 mm size aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.

12

-

-

... More
Preparation of new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed .

30

-

-

... More
M&L preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified and as directed.

35

-

-

... More
Preparation of old painted steel surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.

30

-

-

... More
S&F 140 mm floor door stopper of aluminium alloy body and tongue , anodised ,with hard drawn steel spring ,fixed in floor, complete all as specified and directed.

4

-

-

... More
M&L Machine cut kota stone slab flooring using 20 to 25mm thick slab of 550 x 550 mm size, laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 including dismantling old existing floor, hearth tiling including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and directed.

140

-

-

... More
M&L Machine cut kota stone slab skirtting / dado using 18 to 20mm thick , laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish over and including 10mm thick CM 1:4 on backing coat on brick or concrete surfaces including dismantling wall tiling including cement mortar bedding and rubbish of the premises complete all as specified and directed.

14

-

-

... More
M&L for makarana white marble tiles 30cmx20cm x 20mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing complete over and including 15mm thick screed bed in CM 1:6 including dismantling floor, hearth tiling including cement mortar bedding and rubbish of the premises complete all as specified and directed

4

-

-

... More
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removing rubbish to out side MD land complete all as specified and as directed.

510

-

-

... More
M&L 15 mm thick, internal plastering in CM1:6 on brick PCC block masonry or concrete surfaces finished even and smooth with out using extra cement complete all as specified and as directed.

100

-

-

... More
M&L providing reinforced cement concrete type B1 (1:2:4) using 20 mm graeded stone aggregate as in lintel upto 1.5 m clear span. Cill,steps; seismic and other similar bands ,plinth courses ,string courses, lacing courses ,parapets and railings upto 60 cm in height ,copings , kneelers,apex stones bed plates ,water troughs and the like including necessary form work weathering, slighting rounded or chamfered angles and throating all as directed and specified.

4

-

-

... More
Demolition of cement concrete in ground floor or pavings n exc 15 cm in depth, below or above ground level and removing rubbish to out side MD land complete all as specified and as directed.

20.85

-

-

... More
M&L 100 mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate for sub base as in floor complete all as specified and as directed .

139

-

-

... More
M&L PCC 100mm thick,1:2:4 type B2 by using 40 mm graded crushed stone aggregate as in floor including necessary form work and finishing the surface even and smooth without using extra cement and making impressions of expanded metal complete all as specified and as directed.

139

-

-

... More
M&L PCC 75 mm thick,1:3:6 type C -1 by using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even and fair including filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight complete all as specified and as directed.

80

-

-

... More
M & L PCC 25mm thick, 1:2:4 type B 1 using 20mm graded crushed stone aggregate, including finishing the surface even and smooth with out using extra cement complete all as specified and as directed.

20

-

-

... More
M&L 15 mm thick, external plastering in CM 1:4 on brick masonry or concrete surfaces finished fair and even with out using extra cement complete all as specified and as directed.

160

-

-

... More
M&L 10mm thick, plastering in CM1:6 on brick masonry or concrete surfaces finished even and smooth with out using extra cement complete all as specified and as directed.

150

-

-

... More
M&L plastering 5 mm thick in CM 1:3 on concrete surfaces of ceiling , finished even and smooth without using extra cement complete all as specified and as directed.

100

-

-

... More
Preparation of old decorated surfaces of ceiling surfces and applying one coat of white wash complete all as specified and as directed.

60

-

-

... More
Preparation of new plastered or unplastered surfaces and applying three coats of white wash on ceiling surfaces complete all as specified and as directed.

100

-

-

... More
Preparation of old decorated surfaces of wall surfces and applying one coat of white wash complete all as specified and as directed.

70

-

-

... More
Preparing new plastered or unplastered surfaces and applying two coats of oil bound distemper over one coat of alkali resistant primer on walls complete all as specified and as directed.

150

-

-

... More
M&L preparation of new plastered or un-plastered surfaces of walls and applying two coats of cement base paint over a coat of white cement as primer in camouflage pattern complete all as specified and as directed .

160

-

-

... More
Demolition of cement concrete of any description and in any position including removal of existing water proofing treatment of any description and bedding in any type of roof and removing rubbish to out side MD Land complete all as specified and as directed.

7.68

-

-

... More
Preparing the surfaces of roof slab by brushing with wire brushes for removing of loose / dirt materials etc., and sweeping with brooms or gunny bags or mechanical device etc.,and applying neat cement slurry with 3kg of cement per sqm complete all as specified and as directed.

130

-

-

... More
M&L screed 10 mm thick in CM 1:3 on roof for laying of water proofing treatment using with liquid water proofing compound as per manufacturer instructions complete all as specified and directed. NOTE:- liquid WPC shall be measured and paid separately under respective item.

130

-

-

... More
M&L APP based polymeric membrane minimum weighing not less than 3kg / Sqm and minimum 3mm thick reinforced with polyester non woven fabric weight not less than 150 gms / Sqm and on primed surface of one coat of approved bituminous primer@0.40 Ltr per Sqm by torch application method complete all as specified and as directed .

130

-

-

... More
M & L hydraulically pressed concrete tiles 25cm x 25cm x 20-22 mm thick laid over and including screed bed or bedding layer of 15mm thick in CM 1:4 set, jointed and grouted and flush pointed in CM1:3 mixed with WPC as per manufacturer instructions complete all as specified and directed. NOTE :- liquid WPC shall be measured and paid separately under respective item.

130

-

-

... More
M&L PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate in roof padding , the surface of concrete is to be finished even and fair with out using extra cement complete all as specified and as directed.

6.4

-

-

... More
Supply only liquid water proofing compound( ISI Marked)

68

-

-

... More
S&F in repairs 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia and PVC connection 15mm size, 450 mm long with PTMT nuts complete all as specified and as directed.

4

-

-

... More
S&F in repairs bib tap standard of PTMT any colour high prresure screwed for 15 mm bore (min weight 90 gms) iron pipe complete all as specified and as directed .

6

-

-

... More
S&F in repair stop valve,standard of PTMT any colour high prresure, with long shank and cup (concealed type), screwed for 15 mm bore (min weight 110 gms) iron pipe complete all as specified and as directed .

6

-

-

... More
S&F 600 mm X 450 mm bevelled edge mirror of selected quality glass, 5 mm thick, with PVC frame , mounted on 6mm thick AC building board and fixed to wooden plug with CP brass screws and cup washers complete all as specified and as directed.

4

-

-

... More
S&F sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane including hacking out old broken glass [any thickness, size, quality or description] from metal frames including punching or drilling out old glazing pins / spring clips complete all as specified and as directed.

4

-

-

... More
Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and as directed.

30

-

-

... More
Taking up or down 20mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and as directed.

40

-

-

... More
Re fixing / Re laying old 15mm bore GI tubing and connections in new or old position including provision of new GI fittings ( as ordered) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed .

10

-

-

... More
Re fixing / Re laying old 20mm bore GI tubing and connections in new or old position including provision of new GI fittings ( as ordered) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed .

10

-

-

... More
M&L GI tubing (ISI marked) 15mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floorscomplete all as specified and as directed.

20

-

-

... More
M&L GI tubing (ISI marked) 20mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floorscomplete all as specified and as directed.

30

-

-

... More
M&L for Non skid ceramic tiles, coloured, of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 including demolition of tiles complete all as specified and as directed.

30

-

-

... More
M&L for Non skid ceramic tiles, coloured, of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in skirtings/ dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including10mm thick backing coat in CM 1:4 including demolition of tiles complete all as specified and as directed.

4

-

-

... More
M&L Glazed coloured ceramic tiles of size 450mmx350mmx7mm/ 450mm x 300mm x 7mm thick on vertical surface such as dado/ skirting etc., over and including 10mm thick backing coat in CM 1:4 set and jointed in neat cement slurry and pointed in white cement / coloured cement to match the tiles including demolition of tiles complete all as specified and as directed.

50

-

-

... More
Opening of manhole covers and cleaning the under ground existing sewage lines of 100/150mm dia SGSW/ RCC pipe by rodding the deposited solid / liquid sludge in sewage line and manholes of any depth and size including getting out sludge material by mechanical means through sewage line manholes chamber and removing the same out side MD land and closing the manhole with manhole covers in its original position complete all as required and as directed.

30

-

-

... More
S & F 150 mm bore reinforced cement concrete pipes, one end socketed, class NP2, laid in trenches and jointed with collar in cement mortar (1:1) complete including demolition of existing pipe complete all as specified and as directed .

40

-

-

... More
M&L PCC 1:4:8 type D-2 (using 40 mm graded crused stone aggregate) as in bed to150 mm bore RCC drain pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and as directed.

40

-

-

... More
S&F 500 ltrs capacity rotational moulded polythene water storage tanks white three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including ball valves for 15mm bore pipe, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (minimum weight 142 gms) and taking down old tank complete all as specified and as directed.

2

-

-

... More
S&F in repair viterous china bowl urinal flat back, of size 465 x 355 x 265mm white (Minimum) with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement including CP stop cock 15mm bore, ,PVC connection pipe 15mm bore 600mm length, PVC waste coupling 32mm and waste pipe etc complete all as specified and as directed.

2

-

-

... More
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.

6

-

-

... More
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removing rubbish to out side MD Land complete all as specified and as directed.

4.32

-

-

... More
M&L for rolled mild steel confirming Fe-290 (Gde E-165) in door or gates of angle or other section with gusset plate, rail braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (inclding of steel, sheeting or other covering ) and hanging also fastening and fixing complete all as specified and as directed.

1100

-

-

... More
M&L mild steel TMT bars, 6 to 8 mm dia cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.

190

-

-

... More
M&L mild steel TMT bars, 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.

120

-

-

... More
M&L granite slab 18 to 20mm thick with machine cut edges, rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of any colour / shade, design / pattern as directed, as in steps, jambs, pillars and like bedded and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the shade of granite stone over and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:3 complete all as specified and directed.

22

-

-

... More
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions of any shape / cross section for rough finished surfaces of concrete complete all as specified and as directed.

21

-

-

... More
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits [if any] of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed.

5.4

-

-

... More
M&L reinforced cement concrete type B-1 [Nominal Mix] 1:2:4 using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and as directed.

2.5

-

-

... More
M&L reinforced cement concrete type B-1 [Nominal Mix] 1:2:4 using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts etc complete all as specified and as directed.

4

-

-

... More
M&L sand stone slabs, 5 cm thick, Jodhpur pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and as directed.

50

-

-

... More
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc . removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.

66

-

-

... More
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.

3

-

-

... More
M&L Point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including PVC casing & caping in wall / roof / floor etc, ISI marked with1.6mm thick mild steel/prestressed steel sunken/concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for, one light point controlled by one, one way switch 5Amps complete all as specified and directed .

43

-

-

... More
All as per serial Item No.91.00 above for one ceiling / exhaust fan point controlled by one, one way switch 5Amps

6

-

-

... More
All as per serial Item No.91.00 above but for one 3 pin socket outlet 5 Amps on the same board with other switches complete all as specified and as directed.

9

-

-

... More
All as per serial Item No.91.00 above for one 3 pin socket outlet 5 Amps on independent board complete all as specified and as directed

6

-

-

... More
All as per serial Item No.91.00 above but for 15 Amps 5/6 pin socket point on independent board with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire complete all as specified and directed .

4

-

-

... More
M&L factory made distribution board in sheet metal enclosure in double door with 200A rated bus bar,SPN 8 way, 240V for fixing MCB's complete all as specified and as directed.

2

-

-

... More
M&L factory made distribution board in sheet metal enclosure in double door with 200A rated bus bar,SPN 4 way, 240V for fixing MCB's complete all as specified and as directed.

3

-

-

... More
M&L MCB SPN ‘C’ Curve 10KA, 40 amps complete all as specified and directed .

4

-

-

... More
M&L MCB SP ‘C’ Curve 10KA , 6 to 40 amps 230V complete all as specified and as directed .

16

-

-

... More
M&L switch piano, flush type, single pole, one way, 5/6 Amps, 230 Volts complete all as specified and as directed.

64

-

-

... More
M&L switch piano 15 Amp flush type single pole one way with ISI marked, complete all as specified and as directed.

4

-

-

... More
M&L socket outlet 5Amps 2-in-1,3 pin 230V AC flush type, complete all as specified and directed.

17

-

-

... More
M&L socket outlet 5/15 Amps 2-in-1,3/5 pin 230V AC flush type, complete all as specified and directed.

3

-

-

... More
M&L ceiling rose, 3 phase / PVC / Polycarbonate, isolated bodycomplete all as specified and as directed.

29

-

-

... More
Supply & replacement of LED light fitting 1X10W bulk head surface mounted, decorative oval bulk head edge- lit LED luminaries comprising of high brightness LED's etc., complete with all accessories and connectiong up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed Make : Havells Cat Part No.RUGBYNEONFT10WLED860SSYMTOPC or techno commercially equivalent model of make Bajaj /Philips / CG / Wipro.

5

-

-

... More
S&F lamp holder, PVC / polycarbonate type suitable for LED bulb including LED lamp 9W 230 volts complete all as specified and as directed .

8

-

-

... More
S&F LED light fitting 20W with batten ( integrated driver), 6500K colour temp, decorative type with all accessories internally pre wired including tube rod and connectiong up with twin core twisted flexible copper conductor cable with suitable size including taking down unserviceable fitting complete all as specified and as directed Make : Havells Cat Part No. LHEXBXPNIN1W020 or techno commercially equivalent model of make Bajaj /Philips / CG

20

-

-

... More
Supply, fix ,connecting and testing of energy efficient, pressure die cast housing with heat resistant toughened glass and individual high power LEDs with secondary optics and IP-66 protection of street light luminaries 25 watt , impact resistance, fixed on pole with bracket made out of 25mm dia light grade GI tubing, bent to shape, of length 1.20 metre fixed with MS clamp of size 25X3mm (02Nos) for fixing / holding GI bracket including taking down unserviceable light fitting complete all as specified and as directed . Make : CG Cat Part No. LSTS-25-CDL or techno commercially equivalent model of make Bajaj/Philips/Havells

8

-

-

... More
S&F Exhaust fan of 300 mm sweepwith louvers complete with bracket frame and fixing the exhaust fan on the bracket frame and making necessary electric connection complete all as specified and as directed .

2

-

-

... More
Dismantling and taking out old burnt out winding and bearing of ceiling fan 1200/1400 mm sweepand rewinding with same gauge & sizeof copper winding wire of superior quality including replacement of 23/0.0076 twin core PVC insulated flexible copper wire of required length complete including painting the fan with two coats of synthetic enamel paint of white colour, replacement of worn out bushes,bearings, capacitor, PVC bushes, writing MES Number etc and fixing at same position after repair complete all as specified and as directed.

4

-

-

... More
M&L earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified and as directed. NOTE :(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-( ii) Item includes the cost of GI pipe up to 7.5m for protection of earth wire. any variation in length beyond 7.50 m shall be measured separately.(iii) Item includes cost of lead wire up to 7.5 m Any variation in length beyond 7.50 m shall be measured separately.(iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.

4

-

-

... More
Supply and spreading clean dry sand ( tibba sand) in trenches for cushioning to PVC cable and punning to provide required cover to UG cable complete all as specified and directed . Note :- Punned thickness shall be measured for the purpose of payment.

18

-

-

... More
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed.

60

-

-

... More
Supply, laying, jointing, testing and commissioning 1100 volt grade heavy duty XLPE insulated LT under ground cable, sheathed, as per IS- 7098 (Part I) 1988, galvanized steel strip armoured heavy duty multi stranded aluminum conductor laid in trenches / passed through pipe/duct road crossing, fixed on poles/ wall with clamps made out of mild steel flat iron including fixing accessories like brass cable glands double compression type, lugs, nuts, bolts, washers etc of size 2 core 10 sqmm complete all as specified and directed

260

-

-

... More
S&F GI tubing 40mm bore light grade with all fittings and laid in trenches/ fixed on walls/ poles or laid under road / paving with clampetc., for protection of cable complete all as specified and as directed.

12

-

-

... More
Supply, fix ,connecting and testing of circular LED flood Light of 140W with tapered fin design and excellent thermal management along with IP66 protection complete all as specified and as directed Make : CG Cat Part No. LFLN11-140-CDL/60 or techno commercially equivalent model of make Bajaj / Philips /Havells

1

-

-

... More
Supply, fix ,connecting and testing of LED luminaries having pleasing proporations and well sculpted lines blending seamless with its surroundings, corrosion resistant, weather proof and made with pressure die- cast aluminium housing powder coated graphite grey to meet all IP 65 protection complete all as specified and as directed Make : Havells Cat Part No. VICTORIAPT35WLED730PSYMTOTG or techno commercially equivalent model of make Bajaj / Philips / CG

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.