Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 28,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MES_415880_1Bid Award Id
ViewTender No
GE(A)/BMR-64 OF 2020-21Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick in any type of soil complete all as specified and as directed .
144
-
-
... More
Removal of excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed .
154.5
-
-
... More
M&L PCC 1:4:8 type D2 by using 40mm graded stone aggregate as in foundations filling and mass concrete, complete all as specified and directed.
3
-
-
... More
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams sides and soffits (if any) of foundation and plinth beams and similar work; including rough finished surfaces of concrete complete all as specified and directed.
35
-
-
... More
Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions including rough finished surfaces complete all as specified and directed.
28
-
-
... More
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) including rough finished surfaces complete all as specified and directed.
76.6
-
-
... More
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
57
-
-
... More
All as per item no. 10.00 but suitable for exc 5cm but not exc.10cm wide
7
-
-
... More
M&L TMT steel bars of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
2354
-
-
... More
M&L TMT steel bars of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
750
-
-
... More
M&L RCC M-25 by using 20mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc., basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed.
7.85
-
-
... More
M&L RCC M-25 by using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts and the like complete all as specified and directed.
2
-
-
... More
M&L RCC M-25 by using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified and directed.
0.7
-
-
... More
M&L RCC M-25 by using 20mm graded stone aggregate as in Slabs supported on walls, roofs, landings, balconies, canopies, deck slabs and in shelves and the like and the like complete all as specified and directed.
11
-
-
... More
M&L brickwork with fly ash bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed.
14
-
-
... More
M&L half brick thick wall with fly ash bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:4 complete all as specified and as directed.
7.5
-
-
... More
M&L rendering 15mm thick in CM 1:4 on brick or concrete surfaces, finished fair and even without using extra cement mixed with water proofing compound as per manufacturer instructions complete all as specified and directed. Note :- WPC will be measured and paid seperately.
62
-
-
... More
Supply only water proofing compound (ISI Marked)
15
-
-
... More
M&L rendering 10mm thick in CM 1:6, on fair faces of brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
68
-
-
... More
M&L rendering 5mm thick in CM 1:3, on fair faces of concrete surfaces, as in ceiling finished even and smooth without using extra cement complete all as specified and directed.
56
-
-
... More
M&L 25 mm thick PCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate for as in flooring, surface even and smooth complete all as specified and as directed .
48
-
-
... More
M&L 75 mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate for as in sub base of flooring, laid in panels complete all as specified and as directed .
30
-
-
... More
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr in depth for foundation of pole, taking out cable / pipe line etc and not exceeding 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed.
30
-
-
... More
All as per Item No. 26.00 here in above but in hard / dense soil.
157
-
-
... More
S&F 2000 ltrs capacity rotational moulded polythene water storage tanks white three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I complete all as specified and as directed.
1
-
-
... More
S&F PTMT ball valve heigh pressure with epoxy coated aluminium rod and high density plastic ball suitable for 25mm bore pipe weight not less than 455 gms complete all as specified and as directed.
1
-
-
... More
Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in any type soil complete all as specified and as directed complete all as specified and directed.
500
-
-
... More
M&L 100 mm thick PCC 1:4:8 type D2 by using 40mm graded stone aggregate as in sub-base concrete, complete all as specified and directed.
85
-
-
... More
M&L 100 mm thick PCC 1:2:4 type B1 by using 20mm graded stone aggregate as in flooring, finishing surface even and smooth without using of extra cement complete all as specified and directed.
85
-
-
... More
M&L Forming Construction joint 30mm deep x 10mm wide filled with sealing compound, complete all as specified and directed.
1.6
-
-
... More
M&L 75 mm thick PCC 1:4:8 type D2 by using 40mm graded stone aggregate as in sub-base concrete, complete all as specified and directed.
415
-
-
... More
M&L 40 mm thick PCC 1:2:4 type B1 by using 20mm graded stone aggregate as in flooring, finishing surface even and smooth without using of extra cement complete all as specified and directed.
415
-
-
... More
M&L 38 mm wide Glass dividing strips, 3 mm thick and inserted in position,
conform to design, complete all as specified and directed.
30
-
-
... More
M&L for drilling and tapping cast iron water main (in position) for branch connections of internal dia 15 mm GI pipe complete all as per specification & directed by Engg-in-charge.
1
-
-
... More
S&F of GI pipes, medium grade of 25 mm dia including all fittings complete all as per specification & directed by Engg-in-charge.
60
-
-
... More
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of any dia, set in cement mortar including PCC in bed and haunching against side including removing debris and rubbish outside MD land complete all as specified and as directed.
70
-
-
... More
S & F 200 mm bore Reinforced cement concrete pipes, with collars, class NP2, laid in trenches and jointed in CM 1:2 complete all as specified and as directed .
70
-
-
... More
M&L PCC 1:4:8 bed type D-2 by using 40 mm graded crused stone aggregate as in bed concrete to 200 mm bore RCC pipe including packing under and haunching against the side of pipes after they are laid and tested complete all as specified and as directed .
65
-
-
... More
M&L Squared rubble walling Jodhpur type, regular coursed, well bonded, bedded and solidly hearted, built in cement motar 1:6 complete all as specified and directed by Engg-in-charge.
22
-
-
... More
All as per item no. 42 here-in-above, but except stone
2
-
-
... More
Extra over to squared rubble walling, Jodhpur type, for hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm and dressing face beds and joints as specified regular coursed complete all as per specified and directed by Engg-in-charge.
75
-
-
... More
M&L PCC 1:2:4 type B-1 (20mm graded crushed stone aggregate) as in coping including necessary form work complete all as specified and as directed.
1
-
-
... More
M&L rendering 15mm thick in CM 1:4 on stone surfaces, finished fair and even without using extra cement mixed with water proofing compound as per manufacturer instructions complete all as specified and directed. Note :- WPC will be measured and paid seperately.
50
-
-
... More
Demolition of cement concrete reinforced in ground floor and paving not exc 15 cm including removing rubbish to out side MD land complete all as specified and as directed.
1
-
-
... More
M&L for RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in precast manhole/drain covers including demolition of RCC slab, manhole/drain cover in any position complete all as specified and as directed.
1
-
-
... More
M&L TMT steel bars of 5mm to 10mm dia bars cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
150
-
-
... More
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150 mm bore of pipe complete all as specified and as directed by Engg-in-charge.
4
-
-
... More
All as per item no. 50.00 here-in-above, but for removing existing branch drain, making good to walling and rendering, cutting out branch channel, and making good benchings complete all as specified and as directed by Engg-in-charge.
2
-
-
... More
M&L cast iron soil, waste and vent 100mm bore pipe in any length with or without ears with cement joint fixed to wall etc complete all as directed.
20
-
-
... More
S&F Cast iron cowl suitable for 100 mm bore pipe complete all as per specified and directed by Engg-in-charge.
4
-
-
... More
S&F Cast iron branch pieces single or unequal ordinary or inverted (Spigot & socketed type) or with parallel branches with door suitable for 100 mm bore pipe complete all as per specified and directed by Engg-in-charge.
5
-
-
... More
S&F Cast iron with door bend suitable for 100 mm bore pipe complete all as per specified and directed by Engg-in-charge.
4
-
-
... More
Filling under floors including spreading, levelling in layers n.exc 25mm thick, watering, well ramming and consolidation etc complete all as directed.
0.7
-
-
... More
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc . removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
24
-
-
... More
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
1
-
-
... More
Taking down unserviceable sub main wiring with copper/aluminium conductor,PVC insulated,unsheathed cable of any size drawn through and including rigid PVC or PVC casing caping including earth wire and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
33
-
-
... More
M&L point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including heavy duty non metallic PVC rigid conduit of 25mm dia with accessories concealed in wall/roof/floor etc, ISI marked with1.6mm thick mild steel/prestressed steel sunken/concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light/ fan/bell point controlled by one, one way switch 5Amps complete all as specified and directed.
14
-
-
... More
All as per serial Item No. 60.00 above for one 3/5 pin socket outlet 5 Amps on independent board complete all as specified and as directed
4
-
-
... More
All as per serial Item No. 60.00 above but for one 3 / 5 pin socket outlet 5 Amps on the same board with other switches complete all as specified and as directed.
2
-
-
... More
All as per serial Item No.60.00 above but for 16 Amps 5/6 pin socket point on independent board with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire complete all as specified and directed .
4
-
-
... More
M&L Modular switch 1 way 6A, 1 Module, one way, 230 Volts complete all as specified and as directed.
20
-
-
... More
M&L Modular switch 1 way 16A, 1 Module, one way, 230 Volts complete all as specified and as directed.
4
-
-
... More
M&L socket outlet 6 Amps, 2/3 pin, combined 2 Module, 230V AC flush type, complete all as specified and directed.
6
-
-
... More
M&L socket outlet 6/16 Amps, 2/3 pin, combined 2 Module, 230V AC flush type, complete all as specified and directed.
4
-
-
... More
M&L modular white cover plate with frame, 2 module complete all as specified and as directed.
2
-
-
... More
All as per item no. 68.00 here-in-above but suitable for 3 module
8
-
-
... More
All as per item no. 68.00 here-in-above but suitable for 6 module
2
-
-
... More
All as per item no. 68.00 here-in-above but suitable for 8 module
1
-
-
... More
M&L ceiling rose, 3 phase / PVC / Polycarbonate, isolated body complete all as specified and as directed.
13
-
-
... More
M&L modular fan regulator, stepped type, 120 W- 2 Module, AC, 230 Volts, fixed on existing laminated sheet complete all as specified and as directed.
2
-
-
... More
S&F LED light fitting 20W/ T8 with batten ( integrated driver), 6500K colour temp, decorative type with all accessories internally pre wired including tube rod and connectiong up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed Make : Havells/ Bajaj /Philips / CG
5
-
-
... More
S&F LED light fitting 10W/ T8 with batten ( integrated driver), 6500K colour temp, decorative type with all accessories internally pre wired including tube rod and connectiong up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed Make : Havells/ Bajaj /Philips / CG
2
-
-
... More
S&F LED light fitting 1 x 9 W, bulk head luminariers decorative type with all accessories internally pre wired and connectiong up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed Make : Havells/ Bajaj /Philips / CG
1
-
-
... More
M&L submain wiring with two runs of 4 sqmm with one run of 4 Sqmm earth wire of 1100V grade FRLS PVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through and including 25mm dia PVC rigid conduit with accessories fixed on wall / ceiling with PVC saddles and cadmium plated steel screws and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed.
Note :- Three runs of 4 sqmm and one run of PVC conduit shall be measured as one length for the purpose of measurement.
15
-
-
... More
M&L submain wiring with two runs of 6 sqmm with one run of 6 Sqmm earth wire of 1100V grade FRLS PVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through and including 25mm dia PVC rigid conduit with accessories fixed on wall / ceiling with PVC saddles and cadmium plated steel screws and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed.
Note :- Three runs of 6 sqmm and one run of PVC conduit shall be measured as one length for the purpose of measurement.
18
-
-
... More
M&L Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amps MCB complete all as specified and as directed.
1
-
-
... More
Supply and spreading clean dry sand ( Tibba sand) in trenches for cushioning to PVC cable and punning to provide required cover to UG cable complete all as specified and directed .
Note :- Punned thickness shall be measured for the purpose of payment.
53.8
-
-
... More
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed.
174.55
-
-
... More
Taking down / out old u/s cable from trenches / pole / , of 3.5 core 35 / 70 Sqmm XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor complete all as specified and as directed.
87
-
-
... More
Supply & Lay in trenches, fixing or passing through pole, fixed to wall / pole of 3.5 core 35 Sqmm XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
215
-
-
... More
All as per item no. 83.00 here-in-above, but cable size 3.50 core 50 sqmm
262
-
-
... More
All as per item no. 83.00 here-in-above, but cable size 3.50 core 70 sqmm
290
-
-
... More
S&Fof GI tubing, light grade of 40mm bore , as in road crossings / laid in trenches / fixed on walls / poles etc., for cable protection complete all as specified and as directed.
12
-
-
... More
S&Fof GI tubing, light grade of 50mm bore , as in road crossings / laid in trenches / fixed on walls / poles etc., for cable protection complete all as specified and as directed.
26
-
-
... More
Fixing only of existing change over switch at wall / panel / plywood of any make of size by providing proper fixing arrangement as per siteequirement and makingroper connection of cables with suitable size of lugs complete all as specified and as directed by Engg-in-charge.
3
-
-
... More
S & F in replacement of MCCB,AC,415volts,63 Amp,25KA,4 pole, thermal magnetic release including making necessary connection in existing panel complete all as specified and as directed .
4
-
-
... More
M&L for earthing complete with galvanised steel plate electrode of size 60cm x 60cm x 3.15 mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using 25 X 4 MM size of GI strip by means of bolts, nuts, check nuts and washers made of GI and protected by light grade 40 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 3 of SSR Part I (2009)and Part II (2010) complete all as specified and directed by Engr-in-Charge. Note: 1. The earh resistant value must be well below of 5 ohm irrespective to seasons and any unforeseen condition.
2. Earth should be free from stone.
6
-
-
... More
All as per item no. 90.00 here-in-above, but electrode connection by 4.00 mm dia GI earth wire and protected by 15 mm dia light grade GI pipe.
1
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, classHV, Type-I, flat, size 300mmx 180mm x 40mm as mechnical protection to UG cable , laying with length of cable, complete all as specified and directed.
210
-
-
... More
Supply & Lay in trenches, fixing or passing through pole, fixed to wall / pole of 4 core 16 Sqmm XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
45
-
-
... More
S&F of 25 mm bore gun metal, globe or gate valve, heavy duty confirming to IS -778 with iron wheel head, screwed both ends for iron pipe, non rising forged brass spindle class I and fixed with required necessary GI fittings complete all as specified and directed.
2
-
-
... More
Supply, install, commission and testing facory made cubical type TPN copper bus bar box 200Amp made out of CRCA sheet of 3.15mm thick , outdoor canopy type, CPRI approved , conform to IS-8623, IP-54 class protection, floor mounted, dust and vermin proof,front and rear operated door, mounted on MS angle iron frame work of size 40X40x6mm ,with necessary locking arrangement and duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally and fixed 0.5m above ground level and 0.3m grouted in ground / floor including necessary excavation/ earth work in any type of soil, foundation PCC 1:4:8 type D2 and the panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity of with suitable size of PVC insulated copper conductor, thimbles glands and also space for change over switch up to 125 amps complete all as specified and directed with the following accessories :- (a) MCCB FP 63 Amps, 50 Hz, 415V, 10KA - 01 No (b) DOL starter for 1.50 HP motor
1
-
-
... More
Supply, install, commission and testing industrial type vehicle washing jet pump with 3 plunger system at discharge pressure of 50 to 70 kg/sqcm and max operating flow rate of 11 cum / hr and single phase electric motor driven of capacity 3 HP including 10 mtr high pressure hose with spray nozzle and pressure gauge and controlling valve arrangement complete with necessary foundation and electric connection with suitable size copper conductor cable complete all as directed and specified by Engg-in-charge.
1
-
-
Evaluation Notes How It Works ?