Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MES_558074_1Bid Award Id
ViewTender No
GE (N) BKN TOKEN NO 58 /2022-2023Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply only spring charging motor 220 V AC/DC supply.
1
-
-
Shunt Release EA1 415V AC
2
-
-
Under-voltage Release 415V AC
2
-
-
Closing Preventer 415V AC
2
-
-
Supply only Jaw contact Assy. 630/1000A S1
1
-
-
Supply only Jaw contact Assy. 800/1000A C/H & 1250A S1
1
-
-
Supply only Jaw contact Assy. 1250/1600A C/H, 1600/2000A S1
1
-
-
Supply only Pole Assy. 630-1250 S1 D/O
1
-
-
Supply only Pole Assy. 1250/1600 C & 1600 S1 D/O
1
-
-
Taking out old underground LT Cable of size 10 sqmm to 120 Sqmm of 3.5 core from LT Panelstrenches/floors /road/wall/ pipe/pole/including taking out loop from trenches upto 1.5 mtrs depth, cutting the faulty end of cable and refixing the cable in original position by using flat aluminium sockets/ thimble/ and insulating the all nacked wires of any size including making connection with MCCB's/ Switches complete all as directed by Engineer-in-Charge. Note : Exacavation for taking out LT cable from will measured and paid separatly.
60
-
-
All as per item No. 13 here-in-before but 150 Sqmm to 630 Sqmm 3.5 core
30
-
-
Excavation in trenches not exceeding 1.5 mtr wide, and not exceeding 1.5 mtr in depth; for laying of cables, pipes in soft/loose soil etc and not exceeding 10 Sqm on plan and getting out including trimming of sides all as specified and directed by Engineer-in-Charge
582.14
-
-
Returning filling in, including spreading , levelling, watering and well ramming in layers each not exceeding 25cm in soft/loose soil complete all as specified.
349.29
-
-
Removing surplus spoil to distance not exceeding 50metre and depositing where directed at level not exceeding 1.5metre above the starting point complete all as specified.
232.86
-
-
Supply and laying un-reinforce precast concrete cable cover, class LV type-1 with peak, size 250 mm X150 mmx 40mm for protection of ht cable
6000
-
-
Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by Engineer-in-Charge.
198
-
-
Dis connecting the LT panel of any size and Cap and repair of complete panel by taking out the cable ,Bus -bar , Voltmtr , Amp mtr ,including wiring and other minor parts, cleaning the complete accessories carefully. Minor repairs shall be rectified Parts/accessories shall be cleaned properly and refixing the parts at its original locations, checking and repair of the internal panel wiring with suitable size of wire and remove the carbon deposited inside the contact, cleaning all other spare parts all as directed by the Engineer-in-charge and reassembled after repair/replacement of following parts.
25
-
-
Supply and fixing in replacement Cable indoor/outdoor end terminal jointing kit for LV/LT 1100 V cable heat shrinkable type joint kit complete with jointing material, 04 Nos coloured sleeves(Red, Blue, Yellow and black) each 45 cm long and accessories thimbles etc suitable for 25 sqmm to 50 sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing fixing in replcement complete all as specified and as directed by Engineer- in - charge.
35
-
-
Ditto All as per Srl Item No.21 Here in above but 70 Sqmm to 150 sqmm 3.5 core
25
-
-
Ditto All as per Srl Item No.21 Here in above but 185 Sqmm to 300 sqmm 3.5 core
8
-
-
Ditto All as per Srl Item No.21 Here in above but 400 Sqmm 3.5 core
8
-
-
Ditto All as per Srl Item No.21 Here in above but 500 Sqmm 3.5 core
2
-
-
Ditto All as per Srl Item No.21 Here in above but 630 Sqmm 3.5 core
2
-
-
Supply and fixing in replacement Cable jointing kit for LV/LT 1100 V cable for straight through , heat shrinkable type joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-Charge.
8
-
-
Ditto All as per Srl item No 27 here in above but 70 Sqmm to 150 sqmm 3.5 Core
7
-
-
Ditto All as per Srl item No 27 here in above but 185 Sqmm to 300 sqmm 3.5 Core
2
-
-
Supply and fixing in replacement Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminium conductor, 1100 volts LT grade of cross-sectional area 10 Sqmm 02 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid in repair including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.(ii) Road manually cutting/floor cutting/cutting holes etc in wall required for laying /fixing of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same) Make : /Havells/Finolex/Polycab
755
-
-
Ditto All as per Srl item No 30 here in above but size of cable 16 Sqmm 4 core
400
-
-
Ditto All as per Srl item No 30 here in above but size of cable 25 Sqmm 4 core
500
-
-
Ditto All as per Srl item No 30 here in above but size of cable 35 Sqmm 3.5 core
500
-
-
Ditto All as per Srl item No 30 here in above but size of cable 50 Sqmm 3.5 core
375
-
-
Ditto All as per Srl item No 30 here in above but size of cable 95 Sqmm 3.5 core
200
-
-
Supply and fixing in replacement GI pipe light grade 40 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge.
(Note :- Necessary excavation, earth work and same work shall be measured and paid for separately.)
70
-
-
Ditto All as per Srl item No 36 here in above but dia of pipe 50 mm
50
-
-
Boring of holes under road 100 mm dia, pavement, hard standing by trench less technology(manually) with out disturbing the top surface of roads for laying of cables/GI pipes complete all as specified and as directed by the Engineer-in-Charge.
80
-
-
Taking out old LT underground cable from trench depth upto 1.5 mtrs and laying after removing of defects any type/size laid in trenches including testing complete all as specified and as directed by Engineer-in-Charge.
702
-
-
Supply and fixing in replacement shutters made out of 3.15.00 mm thick mild steel sheet, bent to shape, including taking out old damaged unservicable shutter complete with hinges, handle etc. complete all as directed by Engineer-in-Charge.
10
-
-
Supply and fixing in replacement mild steel medium weight Butt Hinges 100 mm long and fixed with steel screws complete all as specified.
10
-
-
Supply and fixing in replacement mild steel medium weight Butt Hinges 75 mm long and fixed with steel screws complete all as specified.
10
-
-
Supply and fixing in replacement mild steel pressed handles, size 75mm,complete all as specified and as directed by Engineer-in-Charge.
12
-
-
Supply and fixing in replacement mild steel pressed handles, size 100 mm,complete all as specified and as directed by Engineer-in-Charge.
12
-
-
Supply and fixing in replacement digital type tree phase Ampere meter range 0–400/300/200 Amps, with built in selector switch including CTs with proper ratio, square type, flush mounted of size 96 mm x 96 mm including making connection with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge. Make L&T/havells/C&S
10
-
-
Supply and fixing in replacement digital type Volt meter with built in selector switch, range 50 – 520 volts, square type, flush mounted of size 96 mm x 96 mm , accuracy class 1.0, Aux supply 80-300 VAC, CT seconday site selectable 1A/5A, CT/PT programmable frequency including making connection with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge. Make L&T/C&S/havells
10
-
-
Supply and fixing in replacement indicator lamp in diffrent colour code LED/Neon type complete (RYBW) including wiring with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge.
40
-
-
Supply and fixing in replacement Aluminium bus bar of any size with aluminium thimbles nuts, bolts, washers etc complete all as specified and as directed by Engineer-in-charge Note- Aluminium bus bar strips shall be covered with PVC insulation tape of red , yellow, blue and black colour for proper colour coding as per IE rules. Cost of nuts ,bolts, washers, insulation etc. shall be inclusive in the quoted rates.
50
-
-
Supply and fixing in replacement Bakelite sheet 10 mm thick, ISI marked complete all as specified and as directed by Engineer-in-charge.
10
-
-
Material & labour wiring with PVC insulated stranded copper conductor cable 4.00 sqmm complete all as specified and as directed by Engineer-in-charge.
90
-
-
Material & labour wiring with PVC insulated stranded copper conductor cable PVC wire 6 Sqmm single core copper conductor
90
-
-
Material & labour wiring with PVC insulated stranded copper conductor cable 16 sqmm single core complete including suitable size of Luxes/thimble all as specified and as directed by Engineer-in-charge.
90
-
-
Cleaning and preparation of old painted surface of LT panel board complete and spray painting with two coat of synthetic enamel paint with appoved paint all as specified and directed by Engineer-in-Charge.
200
-
-
Supply and fixing in replacement MCCB, 63 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified. Make :- Havells/L&T/legrand
12
-
-
Supply and fixing in replacement MCCB, 100 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.Make :- Havells/L&T/legrand
15
-
-
Supply and fixing in replacement MCCB, 160 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
6
-
-
Supply and fixing in replacement MCCB, 200 Amps, 4 pole, 415 Volts, rupturing capacity not less than 36 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.Make :- Havells/L&T/legrand
12
-
-
Supply and fixing in replacement MCCB, 320 Amps, 4 pole, 415 Volts, rupturing capacity not less than 36 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.Make :- Havells/L&T/legrand
4
-
-
Supply and fixing in replacement MCCB, 400 Amps, 4 pole, 415 Volts, rupturing capacity not less than 36 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.Make :- Havells/L&T/legrand
4
-
-
Supply and fixing in replacement MCCB, 630 Amps, 4 pole, 415 Volts, rupturing capacity not less than 50 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.Make :- Havells/L&T/legrand
2
-
-
Repair of manual operated PF control panel / micro processor based automatic power factor control panel capacity of 21 KVAR to 500 KVAR fixed on various locations including testing, checking and repair and after removing deposited dust/seals/sludge and including taking out burnt/defective items and after fixing required necessary new items ie capacitor, MCBs, circuit wiring etc all as directed by Engr-in-Chaerge.
25
-
-
Supply only MPP type heavy duty power factor improvement capacitor (H/D ) with connector suitable for indoor/out door operation and provided with discharge resistors of rated voltage 440 v 50 HZ 3 phase with delta connection of rating 1 KVAR to 35 KVAR all as specified Make : L/T , SIEMEN Epcos
1100
-
-
Supply only Push botton switch 6 A capacity 240 volts Make RAAS/Alfa/ Veeco
10
-
-
Supply only Miniature circuit breaker triple pole 40 Amp (C curve) 10 KA of capacity
18
-
-
Supply and fixing in replacement MCCB, 100 Amps, 3 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.Make :- Havells/L&T/legrand
2
-
-
Supply and fixing in replacement MCCB, 160 Amps, 3 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and ast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.Make :- Havells/L&T/legrand
2
-
-
Supply and fixing in replacement LT current transformers of capacity 100/5,200/5,300/5,500/5, Amps Make Alfa/ AE/ Veeco
10
-
-
Panel mounted 3 Pole contactor of suitable rating operational voltage 500 volts, AC 50 HZ, inbuilt aux. contacts- 1 No + 1 NC or 2 NO + 2 NC with standard coil voltage 220 volts the surge resistor contract shall be post break type and damping resistances after closing be cut of current rating cap 15 Amp. Make :ABB/BCH/ Siemens/L&T
6
-
-
All as per item No. 68 here in before but rating of capacity 25 Apms.
3
-
-
All as per item No. 68 here in before but rating of capacity 40 Amps.
3
-
-
All as per item No. 68 here in before but rating of capacity 63 Amps.
3
-
-
All as per item No. 68 here in before but rating of capacity 100 Amps.
2
-
-
Supply and fixing in replacement APFC Relay 8 stage with built in multifuction meter for basic, THD and energy with 1 CT/3 CT sensing Option, smart switching, auto setup, THD protection, dual target PF, RS 485 communication, remote monitiring software complete all as directed by Eng-in-charge
2
-
-
All as per item No. 73 here in before but for 12 stage.
2
-
-
Dis connecting the LT servo seteblizer of cap 25 KVA to 200 KVA of any Make and repair of completeservo steblizer by taking out the main circuit plate, servo motors with gears, micro servo voltage controller, cable ,cable terminals etc ,including wiring and other minor parts, cleaning the complete accessories carefully. Minor repairs shall be rectified Parts/accessories shall be cleaned properly and refixing the parts at its original locations, checking and repair of the main circuit panel wiring with suitable size of wire and remove the carbon deposited inside the contact, cleaning all other spare parts all as directed by the Engineer-in-charge and reassembled after repair/replacement of following parts. Note: Spare parts as required for replacement of existing worm out parts shall be measured and paid separately under appropriate items Nos a to here-in-after as supply only.
2
-
-
Supply only servo motor for automatic voltage controller 220 Volts, 50 Hz 10 Kg cap
2
-
-
Supply only automatic voltage controller 220 Volts, 50 Hz
2
-
-
Supplying and filling new mineral grade transformer oil conforming to IS 3357 of 1983 for filling and for topping up in transformer duly filtered with filtration plant to obtain high dielectric strength not less than 40 KV (gap 2.5mm) complete all as specified and as directed by Engineer in charge.
200
-
-
Taking down carefully the defective street light fittings any kind any type from the poles/walls and refixing the same on poles/walls after repair complete all as directed by Engineer in Charge.( Note: A Team of workers for emergency are avlaible inside the camp for 24 Hours) 1. T&P i.e, ladder will provided by the contractor.2. The contractor/his rep will collect the complaint from JE every day 9.00 hrs , the same will be rectified before sunset on same day,If the contractor fail to rectify the defect mentioned in the complaint slip on same day, he will be charged Rs 100/per complaint and same will be recovered from the contract amount.
800
-
-
Supply and fixing in replacement outdoor Driver unit 25 watt with surge protection. Make –CG/Philips/Havells
20
-
-
Supply and fixing in replacement outdoor Driver unit 40 watt with surge protection. Make –CG/Philips/Havells
50
-
-
Supply and fixing in replacement outdoor Driver unit 45 watt with surge protection. Make –CG/Philips/Havells
125
-
-
Supply and fixing in replacement outdoor Driver unit 75 watt with surge protection. Make –CG/Philips/Havells
75
-
-
Supply and fixing in replacement outdoor Driver unit 150 watt with surge protection. Make –CG /Havells/Philips
20
-
-
Supply and fixing in replacement surge protection devices 5 KV compatible with industrial and outdoor LED fixtures upto rated power of 75 Watt Make CG/Havells/Philps
150
-
-
Taking down Unserviceable time switch , checking / testing Time switch by disconnecting the connection and refixing the same after minor repair/resetting all as directed by Engineer in Charge
Note:- item required for repairing of timer switch will measured and pain seperately under appropriate schedule of item.
25
-
-
S & F MCB SP, 63 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge. Make :- L&T/Havells/C&S
25
-
-
S & F MCB 4 pole , 63 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge. Make :- L&T/Havells/C&S
25
-
-
Supply only Panel mounted 2 Pole contactor MNX-22-2P of suitable rating operational voltage 230 volts confirming to IS/IEC60947-4-1, AC 50 HZ, inbuilt aux. contacts- 1 No+01 NC with standard coil voltage 220 volts the surge resistor contract shall be post break type and damping resistances after closing be cut of current rating cap 22 Amp. Make :L&T/C&S/Havells
10
-
-
Supply only Panel mounted 2 Pole contactor MNX-40-2P of suitable rating operational voltage 230 volts confirming to IS/IEC60947-4-1, AC 50 HZ, inbuilt aux. contacts- 1 No+01 NC with standard coil voltage 220 volts the surge resistor contract shall be post break type and damping resistances after closing be cut of current rating cap 22 Amp. Make :L&T/C&S/Havells
8
-
-
Supply and fixing LT Feeder Pillar Box cubical type of size as per IS specifications , 415 volt, factory made dust proof vermin proof (Kiosik type) for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening in two halves with provision of rubber beading and locking system, inciuding copper bus bar of 150 Amp capacity,4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers each MCCBcubical switch shall have be independent opening, panel should be monthed on angle iron frame and legs (vertcal height of legs not less than 30 cm exept in PCC) made from angle of size 50x50x5 mm, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer legs grouted in PCC(1:3:6) type B-2(using 40 mm graded stone aggregate)complete including all connection/ control wiring with suitable size of copper conductor cable ,including danger notice sticker ,comprising the following accessory including testing complete all as specified. (A) Outgoing MCCB 4 Pole 100 Amps, thermal magnetic type breaking capacity 25 KA with thermal magnetic release at 415 volts - 01 Nos (B) Outgoing MCCB 4 Pole 63 Amps, thermal magnetic type breaking capacity 25 KA with thermal magnetic release at 415 volts - 05 Nos (C) Outgoing MCB 4 Pole 32 Amps, thermal magnetic type breaking capacity 10 KA with thermal magnetic release at 415 volts - 04Nos (D) digital type Volt meter with built in selector switch, range 50 – 520 volts, square type, flush mounted of size 96 mm x 96 mm , accuracy class 1.0, Aux supply 80-300 VAC, CT seconday site selectable 1A/5A, CT/PT programmable frequency including making connection with copper conductor cable of suitable size
(E) digital type tree phase Ampere meter range 0–400/300/200 Amps, with built in selector switch including CTs with proper ratio, square type, flush mounted of size 96 mm x 96 mm including making connection with copper conductor cable of suitable size
5
-
-
M & L for earthing complete with GI Earth Plate Electrode 600mm x 600mm x6mm, thick buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connected to Galvanised iron earth strip 32X6 mm drawn through and including Galvanised Iron protection Pipe 40 mm bore (dia) Light grade upto heightl of the transformer foundation where foundation situated by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete 1:3:6 (20 mm graded aggregrate ), Precast RCC 1:2:4 (20mm graded aggregrate ) cover slab 350 x350 x 50mm thick reinforced with and including 8mm dia TMT Bars @ 10 cm Centre to Centre both ways GI Wire Mesh , Funnel, with GI Watering Pipe 20mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 METRE and all as shown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed.
11
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements