Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 84,700Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_678140_1Bid Award Id
ViewTender No
8419/24-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
10
-
-
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soil complete all as specified & directed by Engineer-in-Charge.
102
-
-
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock all as specified & directed by Engineer-in-Charge.
3
-
-
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
29
-
-
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
3
-
-
M&L for powder coated anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified & directed by Engineer-in-charge. Note :- Powder coating of any colour shall be of 50 micron thick.
371
-
-
S&F powder coated aluminium door shutters (minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc.complete all as specified & directed by Engineer-in-charge.
7.2
-
-
S&F powder coated anodised aluminium window and ventilator shutters (minimum thickness of powder coating 50 micron) ,powder coated side hung / sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified & directed by Engineer-in-charge.
5.4
-
-
S&F 4.8 mm thick sheet glass, ordinary quality and glazing in squares exceeding 0.5 Sqm in each pane complete all as specified & directed by Engineer-in-charge.
9
-
-
M&L for 12mm thick prelaminated particle board interior grade with both side laminated with decorative choice fixed with screws to timber frames work or aluminium work for shutters of ward robes ,cabinets, partitions, doors etc complete all as specified & directed by Engineer-in-charge.
90
-
-
S & F in repairs Powder coated Decorail curtain rods 25mm dia with suitable size of decorative type bracket complete all as specified & directed by Engineer-in-charge.
20
-
-
Taking down chowkats or frames exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frame), complete all as specified & directed by Engineer-in-charge.
1
-
-
Demolition of brick work or stone/ boulder masonery built in cement mortar including all quoins arches, pillers etc complete all as specified & directed by Engineer-in-charge.
3.48
-
-
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
3
-
-
Extra over stone walling for hammer dressing to face stones with maximum depression on face from straight edge not exc 20mm and dressing face beds and joints as specified to squared rubble walling, Jodhpur type brought upto courses complete all as specified & directed by Engineer-in-charge.
5
-
-
M&L for Roughly squared stone lintels hammer dressed on face and soffits, hoisted, set and pointed in cement mortar (1:6) complete, n.exc 3m in length complete all as specified & directed by Engineer-in-charge.
0.3
-
-
M&L brickwork with old size fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified & directed by Engineer-in-charge.
12
-
-
Material and labour for 15 mm thick rendering in cement mortar (1:6) on fair faces stone masonry or concrete surfaces finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
17
-
-
Material and labour for 15 mm thick rendering in cement mortar (1:4) on other side of lathing of stone masonry or concrete surfaces finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
17
-
-
M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer complete all as specified & directed by Engineer-in-charge.
17
-
-
M&L for preparation of newly plastered surfaces and applying two coats of cement based paint over a coat of primer complete all as specified & directed by Engineer-in-charge.
57
-
-
M&L for complete removal of existing treatment on walls surfaces and applying two coats of oil bound distemper over a coat of putty and primer including preparation of old plastered surfaces complete all as specified & directed by Engineer-in-charge.
75
-
-
M&L for washing/rubbing down and stopping of destempered, plastered and painted surfaces of wall including cornices etc and making good of holes by filling holes in plastered surfaces with POP mixed with distemper and applying one coat of distemper oil emulsion complete all as specified & directed by Engineer-in-charge.
50
-
-
M&L for preparation of old decorated existing surfaces including cornices, plasterd or un plasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying two coat of white wash on wall complete all as specified & directed by Engineer-in-charge.
74
-
-
M&L for preparation of old painted steel surfaces of any description over 10 cm width girth and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-charge.
10
-
-
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge.
56
-
-
S&F 15mm bore tubes medium grade galvanized with all fittings such as Tee, elbows, sockets, unions, plugs, short lenghts etc. and fixed complete to walls and ceilings or laid in floors concealed or open of any length including taking down or up existing GI tubing & connections all as specified and directed by Engr-in-charge.
25
-
-
S&F Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20 mm dia (minimum weight 210 gms) complete all as specified & directed by Engineer-in-charge.
2
-
-
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed by Engineer-in-charge.
25
-
-
S&F Steel door of 1mm thick including frame, projecting type hinges, sliding door bolt,steel handle, complete, with glazing bars, dovetailed or welded complete all as specified & directed by Engineer-in-charge.
18
-
-
Cutting chases, pinning in, making good to facings on stone concrete block or slab walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good,cutting exceeding 20cm girth complete all as specified & directed by Engineer-in-charge.
36
-
-
M&L for Machine cut cudappah stone slab 20-25mm thick as in shelves including rubbing and polishing complete all as specified & directed by Engineer-in-charge.
12.96
-
-
M&L for Rounding to edges of stone slabs one edge such as in steps, cooking platform, and other similar situations complete all as specified & directed by Engineer-in-charge.
21.6
-
-
M&L for precast cement concrete (1:3:6) type C1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
8
-
-
M&L rendering 15 mm thick in CM (1:4) on fair face of brick work/ concrete surface finished even and smooth without using extra cement mix with using water proofing compound as per manufacturers instructions complete all as specified & directed by Engineer-in-charge. Note:- Water proofing compound shall be measured and paid seperately.
40
-
-
Supply only integral water proofing compound (ISI marked) complete all as specified and directed by Engineer-in-charge.
6
-
-
M&L for glazed ceramic colour tiles 350x250mmx7mm/ 450X350X7mm thick, in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick backing coat in CM (1:4) complete all as specified and directed by the Engineer in charge.
40
-
-
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
26
-
-
Earth work excavating in post holes (or similar holes) in soft/disintegrated rock, each not exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50 Mtr and making good surface complete all as specified and directed by Engineer-in-charge.
4
-
-
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundations, filling & mass concrete complete all as specified and directed by Engineer-in-charge.
0.5
-
-
S&F, rolled mild steel framed work as in doors or gates of angle or other section confirming to Fe 410-W (Gde E-250 quality-A) with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door, fittings and hanging, also fastering and fixing complete all as specified and directed by Engineer-in-charge.
800
-
-
S&F Pre-painted galvalume aluminium zine coating GI based corrugated steel sheeting 0.50mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws complete all as specified & directed by Engineer-in-charge. Note :- (i) The fixing of Galvalume roof sheet as in sun-shades & in walls at certain places to be fixed by making of grooves cutting 75mm minimum with making good surface are inlcuded in the cost of item itself. No extra cost shall be paid for the same. (ii) The pattern and design of sunshades to be fixed as per directions of Engr-in-charge.
200
-
-
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified & directed by Engineer-in-charge.
44
-
-
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
1
-
-
M&L Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
Note : Modular switch and socket shall be measured and paid separately.Make: Polycab/Havells
-
-
-
a) One light point controlled by one switch
20
-
-
b) One ceiling point controlled by one switch
8
-
-
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
4
-
-
All as per item No 48 here on before but with copper conductor cable of nominal class area 2.50 sq mm for phase ,neutral & earth for One 2/3 pin socket outlet 5Amps on independent board.
8
-
-
All as per item No 48 here on before but with copper conductor cable of nominal class area 4.0 sq mm for phase ,neutral & earth for power socket point 15 A .
4
-
-
S&F modular switch one way 6A, 1 module complete all as specified & directed by Engineer-in-charge.
40
-
-
S&F modular socket 6A-2/3 pin combined 2 module complete all as specified & directed by Engineer-in-charge.
12
-
-
S&F modular switch socket combined 6A/16A , 6 pin, 3 module complete all as specified & directed by Engineer-in-charge.
4
-
-
S&F step type modular fan regulator 120W -2 module ISI Marked with valid CML No complete all as specified & directed by Engineer-in-charge.
4
-
-
S&F ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and directed by Engineer-in-charge.
20
-
-
M& L Point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm with 3 mm thick phenolic laminated white sheet cover for mounting of Piano Type switches, sockets, fan regulators complete for the following :-
-
-
-
(a) One light point controlled by one switch.
4
-
-
(d) One socket outlet 6 amp controlled by one switch on the same board with other switches.
1
-
-
S&F switch piano flush button single pole one way 5/6 amp complete all as specified & directed by Engineer-in-charge.
5
-
-
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete all as specified & directed by Engineer-in-charge.
1
-
-
S & F for MCB DB SPN 4 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
1
-
-
S & F for MCB DB SPN 8 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
1
-
-
Supply and fixing MCB's single pole and neutral 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve. complete all as specified & directed by Engineer-in-charge.
1
-
-
Supply and fixing MCB's single pole and neutral 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve.complete all as specified & directed. Maske :-Legrand Cat No Cat No 408617 or equivalent in Appx 'C' list of makes.
16
-
-
Supply and fixing MCB's single pole and neutral 40 to 63 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
1
-
-
Supply and fixing MCB's single pole 6 Amps to 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
8
-
-
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified & directed by Engineer-in-charge. (Note :- Two runs of 10.00 Sqmm cable & one run of 10.00 Sqmm cable as earth wire and one run of PVC conduit shall be measured and paid as one unit length)
35
-
-
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.00 Sqmm (FRLS) for phase and neutral in PVC conduit pipe size 20 mm or above including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 4.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified & directed by Engineer-in-charge. (Note :- Two runs of 4.00 Sqmm cable & one run of 4.00 Sqmm cable as earth wire and one run of conduit shall be measured and paid as one unit length)
250
-
-
S&F building security light fitting LED 35 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lighting souce and PC cover having TOP opening sepreate drive compartment with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable of size 1.5 Sqmm complete all as specified & directed by Engineer-in-charge.
6
-
-
S&F bracket of GI pipe medium grade of 40mm dia, 1.2 meter in length clamps made of FI 40 mm x 6mm incl nuts, bolts & washers, painting and including taking down existing bracket complete all as specified & directed by Engineer-in-charge.
6
-
-
S&F surface and wall mounted LED tube light along with fixture, 4 ft, 20W, extruded aluminium housing provided for efficient heat disspation with polycarbonate, operating voltage 240 V, 50HZ, AC supply and operating tempureture 0 to 50 C, power factor 0.9, lumen output 2000 and provision of new 3 core multistanded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe omplete all as specified & directed by Engineer-in-charge.
14
-
-
S&F wall mounted fan AC single phase 230V of size 400mm sweep with blades and frame and louvers omplete all as specified & directed by Engineer-in-charge.
4
-
-
Taking down ceiling fan/ exhaust fan of any sweep, dismanting blade and including preparation, filling cavity applying one coat of synthetic enamel paint by spraying with machine, re-assembling the fan body to fan and re-fixing in its original position or any other position complete all as specified & directed by Engineer-in-charge.
Note :- Rate quoted by the contractor shall deemed to inclusive of replacing of quarter pin, nut bolt with check nut, rubber real etc.
4
-
-
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron strip 32 x 6mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified & directed by Engineer-in-charge.
2
-
-
M&L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with copper pipe 40 mm bore 3 meter long with minimum thickness of 1.8 mm tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to copper strip 32x6mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified & directed by Engineer-in-charge.
4
-
-
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron wire 4 mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion and including taking down existing earthing complete all as specified & directed by Engineer-in-charge.
1
-
-
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron wire 4 mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion complete all as specified & directed by Engineer-in-charge.
1
-
-
NOTE FOR ITEM No. 72.00 to 75.00
[i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M
[ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways.
[iii]. Main earthing wire from earth electrode to test point upto 7.5 mtr.
[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd.
[v]. GI protection pipe of size 40 mm bore light grade 7.5m.
-
-
-
M&L in repair of for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with GI wire 4 mm mm size complete all as specified & directed by Engineer-in-charge.
6
-
-
S&F steel water tubing 20 mm bore, 'light grade' galvanised, fixed to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
6
-
-
S&F steel water tubing 40 mm bore, 'light grade' galvanised, fixed to walls and ceilings or laid in floors in trench on pole for protection of cable etc complete all as specified & directed by Engineer-in-charge.
6
-
-
S&F steel water tubing 50 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc complete all as specified & directed by Engineer-in-charge.
6
-
-
Supply, laying, testing and commissioning of cable LT XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size of cross sectional aera 10 Sqmm 2 core with cable lugs, gland, cable termination box etc complete all as specified & directed by Engineer-in-Charge.
Note : - Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
35
-
-
Supply, laying, testing and commissioning of cable LT XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size of cross sectional aera 16 Sqmm 4 core with cable lugs, gland, cable termination box etc complete all as specified & directed by Engineer-in-Charge.
Note : - Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
40
-
-
Supply, laying, testing and commissioning of cable LT XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size of cross sectional aera 35 Sqmm 3½ core with cable lugs, gland, cable termination box etc complete all as specified & directed by Engineer-in-Charge.
Note : - Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
300
-
-
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge.
(Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
27.5
-
-
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
83
-
-
S & F Distribution board, VTPN, 4 way, vertical type, double door, 415 volts as per IP -43 with provision for DPX 125 MCCB as incommer and SP/TP MCB as outgoing and electrically connecting up complete all as specified and directed by Engr -in- Charge. Maske :- Indoasian Cat No.811888 or equivalent in Appx 'C' list of makes.
3
-
-
Supply and fixing MCCB 4 Pole 125 Amps, breaking capacity 16 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete all as specified and directed by Engineer-in-charge. Maske :-Legrand Cat No 420055 or equivalent in Appx 'C' list of makes.
(Note: ICS = ICU 100%).
3
-
-
M&L for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps, 240 volts complete all as specified & directed by Engineer-in-charge.
10
-
-
Supply, fabricating, Installing, Testing & Commissioning factory made, CPRI approved, Outdoor type, dust & vermin proof, LT Feeder Pillar box, cubical & compartmentalised design, made of 3.15 mm CRCA sheet for outer side & 2 mm CRCA sheet for inner side, duly powder coated, self supporting, compartmentalised design, totally enclosed, dust and vermin proof, suitable for 440 Volt 3 phase 4 wire system, having front double hinged detachable doors with neoprence rubber gasket including danger plate, earthing strip point at rear side, ventilation louvers, bottom detachable gland plate complete, the panel to be mounted on angle iron frame with legs of size 50 mm x 50 mm x 6 mm thick, at height of 60 cm from ground level grouted in and including PCC 1:2:4 type B1 (using 20 mm graded aggregates), using foundation Bolts Foundation of size 1.00 m x 1.00 m x 0.45 m and including of the following components:
1
-
-
ITEM No. 89.00 CONTD...
(a) Bus bar of aluminium strip 4 Nos.400 Amps with colour code PVC sleeves (b) MCCB 400 Amps 35 KA,4 pole-01 No.( Incoming)
(c) Change over 315 Amps -02 Nos
(d) MCCB 160 Amps 25 KA,4 pole- 04 No. (e) MCCB 100 Amps,25 KA, 4 pole -01 No. (f) MCB 63 Amps , 2 Pole- 03 Nos (for meter)
(g) CT ratio :400/5 (h) Space for 3 Phase KWH Meter-01 Nos
(j) Space for 1 Phase KWH Meter-03 Nos (k) Indication lamp R,Y,B (l) Internal electric connections with suitable copper conductor cable glands, lugs, thimble complete.
(m) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T Part No- WL411021OO00
Note:- 1. Cost of fixing of existing meter deemed to be included in unit quoted rate. 2. All MCCBs shall be adjustable type,
-
-
-
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified & directed by Engineer-in-Charge.
6
-
-
M&L air termination, single pointed aluminium rod 12 mm dia 300 mm long with base fixing complete all as specified & directed by Engineer-in-charge.
12
-
-
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with copper strip of 32X6 mm size complete all as specified & directed by Engineer-in-charge.
100
-
-
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in surface or fixed to DBs or any other indicated situation for loop earthing with aluminium strip of 25X4 mm size complete all as specified & directed by Engineer-in-charge.
260
-
-
M&L Earthing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex. head screw.Material and labour for testing/termination point made out of 32 x 6 mm copper strip of length 150 mm duly housed in suitable MS box insulators etc for linking the down conductor and the earth terminals of the lightening arrester system complete all as specified & directed by Engineer-in-charge.
4
-
-
Supply and fix insulators made out of porcelain for fixing the lightening roof conductor and the down conductor complete all as specified & directed by Engineer-in-charge.
280
-
-
M&L for GI Tubing light grade 40mm dia.for earthing strip protection complete all as specified & directed by Engineer-in-charge.
10
-
-
Supply and lay PVC pipe class 5/10 Kg/cm2 confirming to IS 7834/1987 including special/ fittings, OD 160 dia complete all as specified & directed by Engineer-in-charge.
630
-
-
S&F ducting desert cooler of size (72"x36"x36") with stand including pump (02 Nos) of 40 W with fan blade size 24" & motor of 2 HP with canras fittings complete all as specified and directed by Engineer-in-charge.
Note :- Ducting shall be measured and paid separately.
2
-
-
S&F duct sheet for 3 way duct complete all as specified and directed by Engineer-in-charge.
70.25
-
-
S&F duct insulaton sheet (Heat Proof) for duct cooer complete all as specified and directed by Engineer-in-charge.
70.25
-
-
S&F 3 way duct band for ducting complete all as specified and directed by Engineer-in-charge.
4
-
-
S&F duct coder grill of aluminium grill of size (24"x9") complete all as specified and directed by Engineer-in-charge.
4
-
-
S&F remote panel system for duct cooler complete all as specified and directed by Engineer-in-charge.
2
-
-
S&F 500 ltrs capacity white colour three layer rotational moulded polythene water storage tank (Cylinderical vertical with closed top) hoisted and fixed in position with 20mm bore dia ball brass valves high pressure, with polythene float and flynut screwed for iron pipe or brass ferrule complete all as specified & directed by Engineer-in-charge.
2
-
-
S&F circuit/submain wiring alongwith earth wire with 2x6.0 sq. mm + 1x6.0 sqmm earth wire of FRLS PVC insulated copper conductor, single core cable with and including PVC conduit medium gade of size 25mm recessed including making good the distrubed surface as per existing surfaces complete all as specified and directed by Engineer-in-charge.
(Note :- Two runs of 6.00 Sqmm wire & one run of 6.00 Sqmm earth wire and one run of PVC conduit shall be measured and paid as one unit length)
120
-
-
S&F steel water tubing 15mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls, ceilings or laid in floor/ trenches etc complete all as specified & directed by Engineer-in-charge.
10
-
-
Cutting holes/opening for stone/brick masonry work of suitable size for ducting including making good the distrubed surface in cement mortar (1:4) or PCC (1:2:4) type B-1 and including removal of debries to a distance n.exc. 100m complete all as specified & directed by Engineer-in-charge.
8
-
-
Supply only portable water pump, self priming 7 HP, having inlet & outlet 3" ( 75mm) complete all as specified & directed by Engineer-in-charge. Note :-(i) Contractor shall furnish manufacturer guarantee along with 5 years guarantee of contractor.
(ii) Purchase vouchers & RV to submit for payment.
4
-
-
Supply and connect flexible sunction hose pipe (spiral green) suitable for water pumps of dia 3" (75mm) with suitable GI clamps complete all as specified & directed by Engineer-in-charge. Note :- Contractor shall supply of 30 RM of each roll. No small pieses of pipe.
240
-
-
M&L for foot valve made out of PVC, suitable for 75mm spiral pipe complete all as specified & directed by Engineer-in-charge.
4
-
-
Supplying. installing. commissioning and testing of hi wall split type air conditioner units of capacity 1.5 TR, indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality 5 star rating non CFC type with nominal cooling capacity system complete all as specified & directed by Engineer-in-charge.
8
-
-
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified & directed by Engineer-in-charge.
8
-
-
Supply only desert cooler (Steel body) electric driven single phase, having nominal air flow capacity of 6000 CuM per hour aluminium fan blade,copper winding fan motor, submersible pump of make khaitan Zolta (ISI marked) and all body made with minimum 18 gauge GI sheet including primer coat red oxide and synthetic enamel paint with float valve of 15mm dia complete all as specified & directed by Engineer-in-charge.
18
-
-
Supply and fixing AC plug & play 25 Amps all-in-one device complete all as specified & directed by Engineer-in-Charge. Make :- Havells DBOXX SRCD Cat Part No.- DHDDCDP025202503 or equivalent in Appx 'C' list of makes.
4
-
-