Military Engineer Services Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date7 Aug 2020
Closing Date28 Sep 2020
Tender Amount₹ 21,90,000 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 43,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_354492_3Bid Award Id
ViewTender No
GE SGNR/TOK-17 OF 2020-21Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for PCC 1:4:8 Type D-2 using 40mm graded aggregate in foundation , filling and mass concrete etc. complete all as specified and directed by Engineer - in - Charge
3
-
10
... More
M&L for 100 mm thick, PCC 1:4:8 Type D-2 using 40mm graded aggregate as in sub base complete all as specified and directed by Engineer - in - Charge
82
-
10
... More
M&L for 40 mm thick PCC 1:2:4 Type B-0 using 12.5 mm graded stone aggregate as in damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed by Engineer - in - Charge.
9
-
10
... More
M&L for 75 mm thick PCC 1:3:6 Type B-1 using 20mm graded stone aggregate as in plinth protection complete all as specified and directed by Engineer - in - Charge.
20
-
10
... More
M&L for cement concrete 1:2:4, Type B-1 using 20 mm graded aggregate as in kerb stone etc. complete all as specified and directed by Engineer - in - Charge.
1.2
-
10
... More
M&L for 20-25 mm thick machine cut kota stone slab flooring 20mm thick laid over and including screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer - in - Charge.
45
-
10
... More
M&L for 20-25 mm thick machine cut kota stone slab as in vertical surfces such as skirting, dados, laid over and including 10 mm thick backing coat in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer - in - Charge.
5
-
10
... More
M&L for reinforced cement concrete 1:2:4, Type B-1 using 20 mm stone aggregate M-25 (nominal mix) in foundations ,beams, plinth beams, base of columns complete all as specified and directed by Engineer - in - Charge.
10.37
-
10
... More
M&L for reinforced cement 1:2:4, Type B-1 using 20 mm stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer - in - Charge.
4.5
-
10
... More
M&L for reinforced cement concrete 1:2:4, Type B-1 using 20 mm stone aggregate as in beams, cantilevers, bressumers, lintels over 1.5 m span complete all as specified and directed by Engineer - in - Charge.
1
-
10
... More
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.on rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge.
2.25
-
10
... More
M&L for form work to sides of concrete foundations, footings bases of columns, sides and soffffits (if any) of foundation and plinth beams ans similar works; vertical or to batter on rough finished surfaces of concretecomplete all as specified and directed by Engineer - in - Charge.
17.2
-
10
... More
M&L for form work to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular or palygonal on rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge.
60
-
10
... More
M&L TMT bars as in reinforcement 10 mm dia and over cut to length bent to shape required incl cranking bending spirally for hooping for cols, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia complete all as specified and directed by Engineer - in - Charge.
620
-
10
... More
M&L TMT bars as in reinforcement 06 to 08 mm dia and over cut to length bent to shape required incl cranking bending spirally for hooping for cols, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia complete all as specified and directed by Engineer - in - Charge.
390
-
10
... More
M&L for hard core of gauge n. exc 63 mm, deposited spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed by Engineer - in - Charge.
8.5
-
10
... More
M&L for sand filling under floors, path or in foundations including watering and consolidation complete all as specified and directed by Engineer - in - Charge.
1.2
-
10
... More
M&L for precast machine pressed rubber moulded concrete interlocking paver blocks of any shape and sizeconfirming to IS 15658-2006 of 80 mm thickness, M -35 grade,set,jointed & pointed in neat cement slurry in floor/pavings/path etc with grey cement and pigment. complete all as specified and directed by Engineer - in - Charge.
30
-
10
... More
M&L for brick work with Fly ash bricks (old size), straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
36
-
10
... More
M&L for rendering 15 mm thick in CM 1:4 on brick work or concrete work surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
120
-
10
... More
M&L for rendering 15 mm thick in CM 1:6 on brick work or concrete work surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
115
-
10
... More
M&L for Treating bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-charge .
22.5
-
10
... More
M&L for Treating the backfills in contact with foundation at the arte of 7.5 litres of emulsion per square metre of vertical surface ( area of the structure in contact with backfill to be measured) complete all as specified and directed by Engineer-in-charge .
90
-
10
... More
M&L for Treating the top surface of filled earth at the rate of 5 lires of emulsion per square metre of surface complete all as specified and directed by Engineer-in-charge.
21.6
-
10
... More
M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-charge.
20
-
10
... More
M&L for Treating the soil along with external perimetre of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by Engineer-in-Charge.
38
-
10
... More
M&L for preparation of new plastered surfaces of walls and applying two coats of plastic emulsion paint over one coat of primer complete all as specified and directed by Engineer - in - Charge. complete all as specified and directed by Engineer-in-charge.
115
-
10
... More
M&L for preparation of new plastered surfaces of new walls and applying two coats of exterior emulsion paint over one coat of primer complete all as specified and directed by Engineer-in-Charge.
120
-
10
... More
M&L for preparation of new steel surfaces, over 10 cm width or girth and applying two coats of synthetic enamel paint, over one coat of red oxide primer complete all as specified and directed by Engineer - in - Charge.
36
-
10
... More
S&F anodised aluminium frames for doors, windows,ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
75
-
10
... More
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed by Engineer - in - Charge.
2.5
-
10
... More
S&F powder coated anodised aluminium windows and ventilator luver type shutters, side hung type, without sash bars aluminium saction weighing 0.55 kg/sqm including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitting such as peg stay 150mm long (1 no) hinges type B21 100 mm long (2 No) suitable handle (1No) complete all as specified and directed by Engineer-in-Charge.(Make of pump-Kirlosker).
6
-
10
... More
S&F powder coated aluminium grills to aluminium windows including all necessary fixing arrangments of size 50 mm and 5 mm thick complete all as specified and as directed by Engineer - in - Charge. Note:- Design shall be approved by Engineer - in - Charge.
6
-
10
... More
S&F 100 mm long Aluminium anodised barrel tower bolt of extruded section complete all as sp
17
-
10
... More
S&F for 5.5mm thick sheet glass (tinted),selected quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-charge.
9
-
10
... More
S&F factory made Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, gear operated type with chain wheel and hand chain complete all as specified and directed by Engineer-in-charge. Note: Thickness of laths shall be 1.00 mm
6
-
10
... More
S&F rolled MS roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W(Gde-E- 250)quality-'A' complete all as specified and directed by Engineer - in - Charge.
800
-
10
... More
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any achment conforming to Fe 410-W(Gde-E- 250)quality-'A' complete all as specified and directed by Engineer - in - Charge.
20
-
10
... More
M&L pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer - in - Charge
65
-
10
... More
M&L pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed by Engineer - in - Charge
6
-
10
... More
S&F PVC False Ceiling consisting of 600mmx600mmx6mm thick plain PVC Sheet Used as panel insert in a framework made using powder coated aluminium T-Section of Sizes (25mmx25mmx1mm thick) in square pern of grid Sizes of (600mmx600mm) The Aluminium frame work is supported from the ceiling with the help of GI wire/6mm MS Rods of required sizes to maintain proper level etc. the aluminium frame work is Supported on the wall side with Use of aluminium L section of Size (25mmx25mmx2mm thick) angles etc. complete all specified and directed by Engineer - in - Charge (PVC Ceiling make : Rajshree or equivalent of Sintex or polycon Aluminium T and angle Make : Hindlco,jindal,indalco.
46
-
10
... More
S&F harrison rails, anodised aluminium alloy chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed by Engineer-in-Charge.
6
-
10
... More
M&L for point wiring using approved colour coding as per IS with zero halogen flame retardant (HFFR), smoke free, non toxic, non corrossive installation cable with UNILAY construction copper conductor 1.5 sqmm (nominal area), single core insulated and unsheathed stranded cable 1100 volt grade ISI-694 marked IEC and FIA approved in and including heavy duty electric resistance welded (ERW) stove enameled conduit, heavy duty ISI marked as per IS-9557 (part-1) 1980 for one light/ fan point controlled by one way switch including HFFR insulated unsheathed unilay construction copper conductor 1.5 sqmm (nominal cross sectional area) wire as earth continuity conductor up to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
4
-
10
... More
M & L for point wiring complete for light on independent / combined board with cable 1.5 Sqmm (Nominal Area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC casing and caping, hooks, elbows, junction covers and junction boxes and sinking's for sunken cast iron/ pressed steel terminal boxes 60 cm deep, suitable length and 1.2 mm thick for mounting, switches, sockets, fan regulators with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers, duly grouting and painted with red oxide metal primer and making the good disturbed surfaces of ball with existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper FRLS PVC insulated cable for one light/ fan point controlled by one way switch and connected to common earth dolly, complete all as specified and directed by Engineer in charge.
2
-
10
... More
All as described in Srl item No -47 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed by Engineer - in - Charge.
16
-
10
... More
All as described in Srl item No. 47 here in before but for one switch socket combination 6 pin 5/15 Amps on independent board with 2.5 Sqmm (Nominal Area) FRLS PVC insulated multistranded unsheathed copper conductor and continuous earth contuity conductor along with point wiring of 2.5 sqmm copper FRLS PVC insulated cable copper cable complete all as specified and directed by Engineer - in - Charge.
16
-
10
... More
S & F switch piano flush type 5/6 Amp single pole one way complete all as specified and directed by Engineer - in - Charge
2
-
10
... More
S&F Switch socket combination 2 in 1, 6 pin , 15/16 Amp flush type all as spd and directed by Engr in charge.
16
-
10
... More
S & F switch socket combination 5 pin, 5/6 Amps flush type complete all as specified and directed by Engineer - in - Charge
16
-
10
... More
S & F ceiling rose, surface bakelite 65x50 mm three terminals complete all as specified and directed by Engineer - in - Charge.
4
-
10
... More
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer - in - Charge.
4
-
10
... More
S & F Fluorescent tube light fitting. flameproof type FLP-WP of T5 1x28 w including integral reflector made of aluminium alloy LM6 , with electronic ballast, bipin holders, connector block, etc., and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor with suitable size complete all as specified and directed by Engineer - in - Charge.
2
-
10
... More
S & F water tight bulk head fitting, comprision of connector galvanised cast iron back plate, weather proof enamelled gallery, glass well and including 10 w LED lamp complete all as specified and directed by Engineer-in-Charge. Make :-Havells cat part No. HEXAFT10WLED857SSYMBOPC / Bajaj / Phillips or as equivalent mention in list of make
2
-
10
... More
S&F flame proof exhaust fan complete heavy duty with louvers shutters Ac singlephase 230Volt of size 380mm sweep (15") single phase 0.25 HP motor, 1440 RPM, 2350 cfm sweep by grouting both endsin wall upto required length and making hole of suitable size in wall, making good the existing surface and connecting with ceiling roses with and including flexible cable 3 core copper conductor of size 23/.0076 of suitable length complete all as specified and directed by Engineer-in-Charge
2
-
10
... More
S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
1
-
10
... More
S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 4 ways, 240 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
2
-
10
... More
S & F sheet metal enclosure double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounting VTPN 4 ways, 415 Volts, 250 amps bus bar, stove enamelled dust and vermin proof, IP:43 protection suitable for incorporation FP MCCB (v-Tech) N1 Frame upto 125A, isolators and including give connection with wire and cable etc complete all as specified and directed by Engineer - in - Charge.
1
-
10
... More
S & F MCB ‘B’ series type suitable for 415 volts, AC supply 32 Amps, TP & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
2
-
10
... More
S & F MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
1
-
10
... More
S & F MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
6
-
10
... More
S&F MCCB TPN 40 Amps with breaking capacity 16 KA, fixed TM and 415 volts AC Supply complete all as specified and directed by Engineer - in - Charge.
1
-
10
... More
M&L for 28 mm (outer dia) 1.2 mm thick copper pipe fittings made of copper and suitable for a stem of working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections complete all as specified and directed by Engineer-in-Charge. Note:-All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005
15
-
10
... More
M&L for 22 mm (outer dia) 0.9 mm thick ( Vacuum) copper pipe fittings made of copper and suitable for a stem of working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections complete all as specified and directed by Engineer-in-Charge. Note:-All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005
100
-
10
... More
M&L for 15 mm (outer dia) 0.9 mm thick ( Oxygen) copper pipe fittings made of copper and suitable for a stem of working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections complete all as specified and directed by Engineer-in-Charge. Note:-All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005
150
-
10
... More
Supplying, installing, testing and commissioning of Vacuum Central supply system with accessories comprising of following:- (i) Type :Reciprocating, Air-cooled. (ii) Capacity :60 cfm, 1700 lpm (iii) No. of Cylinders :2 Nos. in each vacuum pump (iv) Drive :Belt driven. (v) No. of Vacuum pumps : 2 Nos. (vi) Motor Capacity : 5.0HP/3.7 KW - 2 SETS
(vii) Receiver Capacity : 1000 liters water capacity vertical type ( included in the system) (viii) Receiver type : Vertical type with inlet, outlet and drain provisions (ix) Accessories : Non-return value, Vacuum Switch, Vacuum gauge, Isolation Valves & Vacuum Filter. (x) Interconnecting Piping : Copper pipe with brass / Mild Steel fittings Note : To run alternative system one main & one standby
1
-
10
... More
Supplying, installing, testing and commissioning of Compressed Air system with accessories (Oil Free) comprising of following:- (i) Type :Reciprocating, Air cooled (ii) Capacity 20 cfm 800 lpm (iii) No. of Cylinders : 2 Nos. in each Air Compressor (iv) Drive :Belt driven (v) No. of Air Compressors : 2 Nos. (vi) Motor Capacity : 05 HP, 1000 liters water capacity receiver ( included in the system) (vii) Receiver type : Vertical type with inlet, outlet & drain provisions 2 SET (viii) Air Drier Type : Heatless Desiccant Type (ix) Air Drier Make : Trident/GEM (x) Air Drier Capacity : 20 cfm (xi) No. of Air driers : 1 No. (xii) Accessories : Non return valves, Air pressure switch, Pressure Gauge, Isolation Valves. Air Filters etc. (xiii) Interconnecting Piping : Mild Steel Pipe of 2" with fittings. Note : To run alternative system one main & one standby
1
-
10
... More
Supplying, installing, testing and commissioning of Oxygen system (3+3) size of oxygen manifold complete with Automatic Control Panel 6 NRVs and 6 Nos High pressure Flexible tail pipes and should be suitable to withstand a pressure of 140 Kg/Cm2 and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mm (internal dia) x 1.5mm, 1 wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm (internal dia) x 1.5mm wall thick. The design of middle and bottom frames should be provided to fit both round and flat bottom complete all as specified and directed by Engineer-in-Charge. Note:- Automatic control panel will be measured and paid separately under srl item no 72 of BOQ
1
-
10
... More
Supplying, installing, testing and commissioning of Oxygen system (1+1) size oxygen Manifold (Emergency Manifold) with 02 NRV, 02 Flexible high pressure Tailpipesand should be suitable to withstand a pressure of 140 Kg/Cm2 and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mm (internal dia) x 1.5mm 1 wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm (internal dia) x 1.5mm wall thick. The design of middle and bottom frames should be provided to fit both round and flat bottom complete all as specified and directed by Engineer-in-Charge.
1
-
10
... More
Supplying, installing, testing and commissioning of Fully Automatic Oxygen Control Panel comprising of following:-
(i) Control Panel Should be enclosed in a metal cabinet with a hinged cover. The side covers of the panel should be made of fiberglass.
(ii) Panel cover should be fitted with a lock to prevent unauthorized access can be swung open for maintenance.
(iii) Should be Fully Automatic Changeover operation and no manual action
(iv) The service gas should pneumatically operate gas change over system.
(v) Delivery of gas through control panel should not be dependent on electricity.
(vi) Should be capable of delivering very high flow rate not less than 1000 litrs per minute at delivery pressure
(vii) Should have Visual indication of the state of the manifold by 3 gauges within the control panel, which should be clearly visible through the transparent cover.
(viii) Should have Audio – visual alarm indication for changeover of empty cylinder bank to filled cylinder bank.
(ix) Built in transformer to ensure safe operation by low voltage.
(x) Microprocessor based alarm signal control with high ‘db’ Siren system.
1
-
10
... More
Supplying, installing, testing and commissioning of Medical Gas Outlet Points / Terminal Unit (Suction & Air ) Surface mounted Gas outlets front loading + Color coded as per NABH Oxygen Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) complete all as specified and directed by Engineer-in-Charge.
15
-
10
... More
Supplying, installing, testing and commissioning of Medical Gas Outlet Points / Terminal Unit ( Suction & Air ) Surface mounted Gas outlets front loading + Color coded as per NABH Vacuum Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) complete all as specified and directed by Engineer-in-Charge.
15
-
10
... More
Supplying, installing, testing and commissioning of Medical Gas Outlet Points / Terminal Unit (Suction & Air ) Surface mounted Gas outlets front loading + Color coded as per NABH Compressed Air Outlets 4 Bar - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) complete all as specified and directed by Engineer-in-Charge.
15
-
10
... More
S&F 15 mm Isolation valves should be 90 degree turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. (internal dia) of the copper pipe and the ball valve should have same dimensions to avoid the flow friction complete all as specified and directed by Engineer-in-Charge. Make :- Zoloto, RN, JSI or equivalent approved Engineer-in-charge.
12
-
10
... More
S&F 22 mm Isolation valves should be 90 degree turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. (internal dia) of the copper pipe and the ball valve should have same dimensions to avoid the flow friction complete all as specified and directed by Engineer-in-Charge. Make :- Zoloto, RN, JSI or equivalent approved Engineer-in-charge.
10
-
10
... More
S&F 28 mm Isolation valves should be 90 degree turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. (internal dia) of the copper pipe and the ball valve should have same dimensions to avoid the flow friction complete all as specified and directed by Engineer-in-Charge. Make :- Zoloto, RN, JSI or equivalent approved Engineer-in-charge.
4
-
10
... More
S&F Oxygen flow meter suitable for Bpc flowmeter with unbreakable humidifier bottle complete all as specified and directed by Engineer-in-Charge.
15
-
10
... More
S&F S.S adaptor suitable for Bpc flowmeter complete all as specified and directed by Engineer-in-Charge.
15
-
10
... More
S&F Ward Vacuum Unit with suction jar of capacity 600 ml + Regulator, suitable bracket complete all as specified and directed by Engineer-in-Charge.
15
-
10
... More
S&F S.S adaptor suitable for Ward Vacuum Unit complete all as specified and directed by Engineer-in-Charge.
15
-
10
... More
S&F Zonal valve box comprising of following:- (i) Wall mounted M.S box with powder coated & lockable. (ii) Frontglassmountingeasilyvisible & using imported brass body quarter turn ball valves Using for opening & closing position.The valve box door cannot be closeduring valve closing position. (iii) Zonal valve box for Three Gas Services
3
-
10
... More
S&F area gas alarm panel six lines, would audio Visual alarms for each gas used on the floor and come fitted with test and mute button Running on electricity 220 V,these units are suggested to be fitted on each floor as well as are as of heavy usage.it would be fitted with a pressure gauge.It indicates low,medium & high pressure sensors complete all as specified and directed by Engineer-in-Charge.
2
-
10
... More
S&F bed head panel 4 ft long of New Model comprising of following:- (i) 5/15 amps switch -sockets -06 nos (ii) Rail for mounting accessories- 01 no (iii) Ward suction jar (Erection included) each- 01 no (iv) Oxygen outlet - 01 no (v) vaccum outlet -01 no (vi) monitor stands -01 no (vii) Oxygen flow meter -01 no (viii) air outlet -01 no Note: Note:- Srl item No 85(iii),85(iv), 85 (v), 85 (vii), 85 (viii) will be measured and paid separately under srl item no 73, 74, 75, 79 and 81 of BOQ
15
-
10
... More
Note : Special Notes (Sr No 65 to Sr No 85) :- (i) The quoted rate deemed to inclusion of designs of the system as per site requirment, supply installation, testing and commisioning. (ii) Prior commencement of work contractor along with a technical team pertains to above work will visit the site,design the system and give the complete detailed drawing of work proposed and get the approval of accepting officer accordingly. (iii) All LED lights should be marked with GE SGNR and date of fixing.
-
-
-