Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 98,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681554_1Tender No
GE/JODH (A) NO 1- OF 2024-25 (9299/E8)Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per item No. 1.00 here-in-above, but cross sectional area 35 sq mm 3.5 core.
700
-
-
All as per item No. 1.00 here-in-above, but cross sectional area 50 sq mm 3.5 core.
800
-
-
All as per item No. 1.00 here-in-above, but cross sectional area 70 sq mm 3.5 core.
500
-
-
All as per item No. 1.00 here-in-above, but cross sectional area 95 sq mm 3.5 core.
400
-
-
All as per item No. 1.00 here-in-above, but cross sectional area 150 sq mm 3.5 core.
300
-
-
S&F in replacement of twin core aluminium conductor 1100 volts grade cross sectional area 10 sq mm 2 core, laid in trenches/ducts /encased in GI pipe /fixed to pole/service connection complete all as specified and directed by Engineer-in-Charge.
400
-
-
Supplying and laying in Material and Labour for GI tubing medium grade in repairs incl. accessories for protection of cables on poles / under road crossing of sizes 80 mm bore, complete all as specified and directed.
40
-
-
All as per item No. 10.00 here-in-above, but sizes 50 mm bore
50
-
-
All as per item No. 10.00 here-in-above, but sizes 40 mm bore
40
-
-
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil, complete all as specified and directed.
731
-
-
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth upto 3.0 m for erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and getting out in hard/dense soil, complete all as specified and directed.
3
-
-
M&L for dry clean tibba sand as in sand cushioning to underground cable including punning down of sand layer, complete all as specified and as directed. Note :- Punned thickness shall only be measured and paid.
248
-
-
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250 mm x 150 mm x 40 mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10 mm over underground cables for protection, complete all as specified and as directed.
13650
-
-
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soils complete all as specified and directed.
450
-
-
Removal of excavated material soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
282
-
-
M&L for Auguring/ Driling /Boring of holes under road, pavement, hard standing by trenchless technology by mannual /machine, including fixing of HDPE pipe of 100 mm bore dia, complete all as specified and directed.
100
-
-
Re-routing/relaying of existing LT cable PVC/XLPE insulated aluminium conductor armoured with glavanised steel wire complete of any size and core from any position i.e ground /wall/poles/ culverts etc complete with protection cover, sand, pipe complete all as specified and directed by Engineer-in-charge. Note:- (i) Old cable as obtained shall be re-used. (ii) Old serviceable protection cover, protection pipe and sand obtained under this item shall be reused if found serviceable.
(iii) Earth work and any other new items shall be measured and paid separately under relavent items.
200
-
-
Material and labour for spray painting to outdoor type double door LT panels/feeder pillar box and replacement of door hinges, sliding bolts, cable entry MS sheets, cable glands, pedestal locks, bow handle and connected accessories where required by welding, cutting, drilling etc and incl fixing with MS nuts and bolts and cleaning of panels from inside and outside and removing any faulty part of cable and preparing the cable for connection with suitable Al lugs and insulating with proper colour code PVC tape whereever required and including two coats of spray painting by synthetic enameled paint complete all as specified and directed by Engr-in-Charge. Note:- 1) Proper shut down will be taken by the authorised rep only. 2) Panel should be made vermin proof and close properly after repair.
30
-
-
Material and labour in replacement for steel structure, cross arms, bracing supports, clamps, back plates of any type, section incl. nuts, bolts, washers, welding, fabrication/bending cold or hot in any size and shape required at site complete applying of two coats of aluminum paints over a coat of red oxide primer incl dismantling complete all as directed by Engr-in-charge.
6
-
-
Material and labour for replacement of old unserviceable CT of LT Panel /Feeder pillar box with CT of ratio upto 200/5 Amps or as required at site according the load incl connecting, disconnecting and testing complete all as directed at site.
4
-
-
Material and labour for replacement of old unserviceable indicator lamp any type with LED based indicating lamps of RYB colour incl disconnecting and connecting of the same all as directed at site.
25
-
-
Material and labour for fabrication of copper busbar iE26:E29 hot in any size and shape all as directed and including RYB insulation mounted on epoxy cast/polymer glass insulators all as directed by Engr-in-charge.
5
-
-
Supply, fixing and replacement of MCCB 800 Amps 4 pole 50 KA 415 Volts 3 Phase 4 wire, microprocesssor release type MTX1.0 (Icu=Ics=100%), Uimp=8kV including accessories like spreaders, nut bolts, lugs etc suitable setting complete all as directed by Engineer-in-Charge.
1
-
-
All as per item No. 26.00 here-in-above, but MCCB 400 Amps 4 pole 36 KA.
5
-
-
All as per item No. 26.00 here-in-above, but MCCB 250 Amps 4 pole 36 KA, thermal magnetic adujstable release type.
5
-
-
All as per item No. 26.00 here-in-above, but MCCB 160 Amps 4 pole 36 KA, thermal magnetic adujstable release type.
10
-
-
Supply, fixing and replacement of MCB SP 40 Amp, 10 KA 240 Volt complete all as directed by Engineer-in-Charge.
12
-
-
M&L for end outdoor/indoor jointing kit suitable for 4 to 16 sqmm 3.5 /4 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable, complete all as specified and directed.
10
-
-
M&L for end outdoor/indoor jointing kit suitable for 25 to 50 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable, complete all as specified and directed.
10
-
-
M&L for end outdoor/indoor jointing kit suitable for 70 to 150 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable, complete all as specified and directed.
5
-
-
M&L for end outdoor/indoor jointing kit suitable for 185 to 300 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable, complete all as specified and directed.
5
-
-
M&L for earthing complete with galvanized steel earth plate electrodes 600mmx600mmx6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2010 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of strata incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site. Note : 1) Rate included for excavation & earth work in any type of strata as shown in electric plate no-3 in SSR Part-I. 2) Rate included for dismantling of old earth pit and removal from site.
20
-
-
M&L for earthing complete with copper earth plate elctrodes 60x60cm x 6 mm thick and 20x3 mm copper strip as earthing lead buried directly in ground (Preferably in veritical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL) connected to Copper strip of size 20x3 mm earth lead by means of bolts, nuts, check nut and washer of copper including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore "medium grade" galvanized iron water tubing fixed with case iron funnel and wire mesh and 25 mm bore "light grade" galvanized iron protection pipe for earth lead copper strip upto 5m length charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on comletion.
Note:- 1.(Rate included for excavation & earth work in any type of strata as shown in electric plate no-3 in SSR Part- 2)
32
-
-
Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 400 amps duly insulated by insulation of RYB colour 800 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm and including of lowers on both sides including embedding the panel in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and including danger board and including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and comprising of the following:-
2
-
-
(A) IN COMING:- (a) MCCB 4 Pole 415 Volts 36 KA 400 Amp rating microprocessor adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -02 No
-
-
-
(b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No.
-
-
-
(c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No
-
-
-
(B) OUT GOING:- (a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating microprocessor adjustable release release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -02 Nos
-
-
-
(b) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating microprocessor adjustable release release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 Nos
-
-
-
(c) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating microprocessor adjustable release type including spreaders , nut, bolts, lugs etc (Icu=Ics=100%) -02 No
-
-
-
(d) MCCB 4 Pole 415 Volts 36 KA 100 Amp rating microprocessor adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -02 No
-
-
-
(e) MCB 32 Amp TPN including , nut, bolts, lugs etc -02 Nos
-
-
-
Supply, install, testing and commissioning as in replacement of feeder pillar box, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 4 PH, 50 HZ, AC supply system having aluminium bus bars duly insulated by insulation of RYB colour 600 Amps rating mounted on porcelain insulators. The size of the panel should not be less than 600 X 500 X350 mm and panel shall be powder coated, factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm and ground clearance 600 mm minimum duly embedded in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone agg.) as in plateform and including wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable complete all as directed by Engr-in-charge and comprising of the following:-
3
-
-
(A) IN COMING:- (a) MCCB TPN 415 Volts 35 KA 250 Amp rating microprocessor adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No
-
-
-
(b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No.
-
-
-
Material and labour Cement concrete (1:2:4) type B -1 using 20 mm graded stone aggregate for pedestal of poles/copping including necessary frame work ,fair finishing to exposed surfaces using extra cement complete form, all as directed by EIC.
3
-
-
Material and labour for Cement concrete (1:3:6) type C -2 using 40 mm graded stone aggregate for foundation of pole /struts/stay assembly etc complete all as directed by EIC.
15
-
-
Material and labour in replacement for prestressed cement concrete poles 9 M long of size 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10, conforming to relavent latest IS including dismantling and refixing of cross arm, security light fittings, brackets or any other existing fittings etc connecting, testing including dismantling and removal of broken pole and coping complete all as specified and directed at site. NOTE:- (i) Earthwork, PCC will be measured and paid separately under relevant item.
(ii) Removal of dismantled items from site are included in rate quoted by the contractor.
25
-
-
Dismantling and Supply, erection and fixing in true vertical position steel tubler swaged pole 09 mtr long type (410-SP-31) conforming to IS -2713 (part 1 and 2) - 1980 complete with cast iron base plate, pole cap, MS bolts, nuts and screws, welded and reduced section and lonitudinal weld seam throughout entire length of pole including material and labour for 2 coats of black bituminous paint throughout internally and externally upto planting depth and remaining exterior position of pole with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
6
-
-
Dismantling of insulators any type any size from existing poles, complete all as specified and directed.
250
-
-
Supply and fix pin type porcelain insulator, vitreous white brown or green including one galvanised mild steel spindle two GI washer and GI Nuts 100 mm height 65 mm dia for 1100 volts grade, complete all as specified and directed.
180
-
-
Supply and fix shackle Type, porcelain, vitreous, white, brown or green insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel straps of size 31 x 3 mm, insulator bolt of 12 mm dia, washers and nut complete all as specified and as directed.
70
-
-
M&L for disconecting and re-connecting of burnt LT XLPE cable from panel to OH conductor on pole/ panel/equipment including removing of faulty part of cable, preparation of cable for connection, suitable Al lugs, nut bolts, glands, GI pipe etc and as directed on site by EIC. Note: (i) The cost of earth work for taking out LT cable loop and refiling will deemed to be included in above quoted rate. (ii) GI pipe and Al Lugs to be measured under separate Sch 'A' item mentioned.
50
-
-
S&F in replacement of Aluminium lugs of 16 Sqmm all as specified and directed by Engineer-in Charge
50
-
-
S&F in replacement of Aluminium lugs of 25 Sqmm all as specified and directed by Engineer-in Charge
90
-
-
S&F in replacement of Aluminium lugs of 35 Sqmm all as specified and directed by Engineer-in Charge
80
-
-
S&F in replacement of Aluminium lugs of 50 Sqmm all as specified and directed by Engineer-in Charge
50
-
-
S&F in replacement of Aluminium lugs of 70 Sqmm all as specified and directed by Engineer-in Charge
120
-
-
S&F in replacement of Aluminium lugs of 95 Sqmm all as specified and directed by Engineer-in Charge
125
-
-
S&F in replacement of Aluminium lugs of 120 Sqmm all as specified and directed by Engineer-in Charge
75
-
-
S&F in replacement of pathway light LED bollad light 10 watt tripod style inverted pyramid bollaed of made up of aluminium casting with acrylic diffuser for soft illumination, dimension of the bollard must be-810 mm height from base and 180 mm top surface(tripod type surface) both fixture and driver must have separate BIS marked registration number and must be clearly mentioned on fixture & as well as on driver also,complete all as specified and directed by Engineer-in Charge
20
-
-
Labour only for Re-stringing, restraining ACSR conductor laid height up to 12 meter over, OH LT line on steel/PCC poles after removing the binding from insulators, lowering the ACSR conductor or broken OH line due to any reason, jointing the broken conductor, Re-winding the ACSR with insulators including providing binding wire, jumpering & connecting the existing service cables after re-stretching/Re-straining to OH line & removing unavoidable sag in the lines, complete all as specified and directed by Engr-in-charge Note :- 1. Proper shut down will be taken by the authorised rep only. 2. The necessary man power, tool & plant, ledder and JCB/ Veh required for is deemed to incl in the rate quoted for the job.
20000
-
-
Supply, fixing, stringing, testing and commissioning of ACSR insulated rabbit conductor of size 6+1/.35 mm binding with insulators including binding material and connection of all service connections/existing cables complete all as specified and as directed.
Note :- (i) Rate of dismantling of old u/s conductor is deemed to be included in quoted rate.
8400
-
-
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm 2 core nominal cross section in service connections, complete all as specified and directed by Engr-in-charge.
600
-
-
Cutting and trimming of trees and branches to clear the over head line in the arc of LT/ HT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed.
Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever.
2. The cutting / trimming of tree branches shall be done to atleast 2.00 metre radius of OH line.
3. The unit of measurement is 'SPAN' i.e. distance covered between two poles. 4. Proper shut down will be taken by the authorised rep only. 5. The necessary man power, tool & plant, cutting tools and JCB required for cutting/pruning of branches is deemed to incl in the rate quoted for the job
450
-
-
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red color and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 30x25cm size complete all as specified and as directed.
50
-
-
Material and Labour for preparation of old painted surface and ZEBRA painting of PCC/steel poles 9/11 m long alongwith road upto 1.5 m height from pedestal, with two coats of enamel synthetic paints in 30 cm height incl painting of pole coping with white paint all as directed by EIC
200
-
-
M&L for painting in steel tubular pole/rail pole upto 9 mtr long applying two coats of enamel synthetic silver paints over including M&L surface coat of red oxide incl painting of pole coping with white paint and zebra painting upto 1.5 mtr from pole coping all as directed by Engr-in-Charge.
30
-
-
Material and Labour for preparation of old painted surface for steel structure, cross arms bracing supports ,clamps, back plates of any type, section incl. nuts, bolts, washers, pipes mounted on PCC/steel poles 9/11m long alongwith road with two coats of enamel synthetic paints all as specified and directed by Engr-in-Charge
10
-
-
Material and labour for writing pole number of minimum size 10 cm height with black paint over base of yellow paint on PCC/steel poles of LT supply complete all as directed by EIC.
200
-
-
M&L in replacement for stay assembly complete with 230x230x 6 mm thick plate and 16 mm dia stay rod all as shown in elect plate No-1 of SSR-part -1 including stay wire of size 7/4mm dia and suitable loop insulator of appropriate size all as spcified and directed by Engr in charge. Note : Rate quoted is deemed to be included excavation in any type of soil, PCC for stay and dismantling of old stay assy.
8
-
-
Cleaning, servicing, calibration and testing complete LT, Air circuit breaker of any capacity, 415V, 3 phase, 50 Hz after shut down the electric supply, cleaning and de-carbonisation of all terminals, lubricating the all moving mechanical parts and calibrate according the load and replacement of unserviceable part like as battery,OFF button, ON button LED indicators after re-fixing at the same position complete all as directed by Engr-in-Charge.
NOTE:- Quated Rate is to be inclussive of replacemnt of all spare parts.
15
-
-
S&F in replacement of decorative cove light LED ROPE for indoor & outdoor (water proof) with driver (20 meter in length),complete all as specified and as directed.
14
-
-
M&L for straight through joint kit suitable for 10 to 16 sqmm 3.5/4 core XLPE/PVC cable 1100 volts grade,heat shrinkable type complete including preparing of cable all as directed by Engr-in-Charge
14
-
-
M&L for straight through joint kit suitable for 25 to 50 sqmm 3.5 core XLPE/PVC cable 1100 volts grade,heat shrinkable type complete including preparing of cable all as directed by Engr-in-Charge
9
-
-
M&L for straight through joint kit suitable for 70 to 150 sqmm 3.5 core XLPE/PVC cable 1100 volts grade,heat shrinkable type complete including preparing of cable all as directed by Engr-in-Charge
8
-
-
M&L for straight through joint kit suitable for 150 to 240 sqmm 3.5 core XLPE/PVC cable 1100 volts grade,heat shrinkable type complete including preparing of cable all as directed by Engr-in-Charge
8
-
-
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
15
-
-
Supply and laying in replacement of synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (supersending IS 5424) suitable for electrical shock safety of sizes 2X1 m complete all as specified and as directed.
11
-
-
All as per item No. 72.00 here-in-above, but 3 mm thick for voltage upto 33 KV.
10
-
-
Cleaning and re-filling of fire extinguisher, 1 Kg, DCP (dry chemical powder) type including filling media/material and replacement of required accessories for ready to use complete all as specified and as directed.
8
-
-
All as per item No. 74.00 here-in-above, but 6 Kg.
10
-
-
All as per item No. 74.00 here-in-above, but 22.5 Kg, CO2 type
5
-
-
NOTE:- (i)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%