Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 87,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_644527_1Bid Award Id
ViewTender No
8433/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
General pages, special conditions and particular specifications etc
BOQ Items
M & L for rough cast plaster mix with crusted stone (6-10 mm), sand and cement in the ratio 1:1:1 , over 15mm thick rendering in CM 1:4 as in under coat including dubbing coat (if required) complete all as specified and directed.
223
-
-
Supply only liquid water proofing compound of approved quality and make confirming to IS complete all as specified and directed.
54
-
-
M&L for preparation of new plastered surfaces of wall and applying two coats of Plastic emulsion paint over a coat of primer over applying wall care putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
1460
-
-
M&L for complete removal of existing treatment and preparation to Old plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
100
-
-
M&L for preparation and complete removal of existing treatment of Old plastered surfaces of wall and applying two coats of Plastic emulsion paint over a coat of primer over applying wall care putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
1300
-
-
M & L preparation new decorated surfaces of walls for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
1514
-
-
M & L preparation and complete removal of existing treatment of Old decorated surfaces of walls for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.complete all as specified and directed.
660
-
-
NOTES for item No 9.00 & 10.00 above:-
The following precautionary measures shall be ensured by the contractor before and during execution of work
(i) All painting works shall be got executed through original materials manufacturing company or their authorised applicators as approved by GE and contractor should submitt MOU with the manufacturing company or their authorised applicators before execution of work and entire work shall be executed with the approved firm.
(ii) After completion of painting work contractor shall remove and clean all the droplets /stain of paint left on the floor, glasses and joinery.
(iii) OEM/authorised OEM applicator should give guaranttee of minimum 05 years and mentioned in MOU submitted to the department before commencement of work.
(iv) Aurthorised applicator shall be and all materials shall also be of similar make as approved by GE.
-
-
-
Dismantling floor, hearth or wall tiles, including cement mortar, removing serviceable tiles from site & rubbish off the premises, complete all as specified and directed.
245
-
-
M&L non skid ceramic coloured tiles 7 to 8mm thick area of each tile not exceeding 0.18 Sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bedding in cement mortar 1:6 complete all as specified and directed.
80
-
-
M&L for glazed ceramic coloured tiles 7 to 8mm thick in vertcial surfaces of size exceeding 0.11 Sqm but not excceding 0.18 Sqm set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick screed plaster in cement mortar 1:4 complete all as specified and directed.
160
-
-
M&L for 18 to 20mm thick granite ( of any type ) work (table rubbed and polished ) in steps, jambs, pillars, window -cills, cooking platforms and like pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including laid over 15mm thick screed bed in CM (1:6) and rounding to edges of stone slab, complete all as specified and directed.
5
-
-
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
1
-
-
M&L RCC, type B-1 (1:2:4) using 20mm graded aggregate in, slab supported on wall, walls beams and columns in floors, roof landings complete all as specified and directed.
1
-
-
M&L TMT bars of 6 to 8mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia complete all as specified and directed.
60
-
-
M&L form work for flat fair finished surfaces of concrete to soffits of suspended slabs such as roof slab not exceeding 200mm thick complete all as specified and directed.
4
-
-
S&F in repairs, 25mm dia stainless steel curtain rod heavy duty with a pair of decorative Curtain Finials/ knob & heavy Curtain Support Bracket for rod made of stainless steel, etc. complete all as specified and directed
50
-
-
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc 1.50 sqm each and removing from site complete all as spd & directed and making good disturbed surface of walls in cement mortar (1:3) complete all as specified and directed
4
-
-
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm and n.exc 4.00 Sqm each and removing from site complete and making good disturbed surfaces of wall in CM (1:3) complete all as specified and directed.
15
-
-
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with M.S. square tube and fixing in opening as per specification & drawing complete all as specified and as directed.
18
-
-
S & F for factory Made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
6
-
-
S & F sheet glass 4mm thick ordinary quality and glazing with oil putty / beads / pin in square not exc 0.50 Sq.m in each pane, complete all as specified and directed.
25
-
-
S & F 4.8mm thick tinted glass of any colour complete all as specified and directed.
28
-
-
S&F powder coated anodised aluminium frame for doors,partition wall, windows, ventilators with one or more rebates including joining cleat , glazing clips, rubber packing, anodised aluminium snap beading, screws, hinges and rubber packing and fixture for movement and fixing etc. complete all as specified etc. complete all as specified and directed.
280
-
-
M & L in repairs (including taking down shutter and refixing the same) Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
8
-
-
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
22
-
-
Taking down old unserviceable 15mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed.
25
-
-
Taking down old unserviceable 20mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed.
10
-
-
S&F 15mm GI water tubing( Concealed type), medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed.
25
-
-
S&F 20mm GI water tubing, medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed.
10
-
-
Taking out old unserviceable water closet and S & F padestal pattern Omega Siphonic flush alongwith soft close seat cover size 660 x330 x 720 mm, white (including atach flush tank alongwith all flushing cistern arrangements ) with ‘P’ or ‘S’ trap, front or back inlet including connection to trap and to flushing pipe, anti syphonage pipe , including PCC (1:2:4) type B-1 for fixing of WC and making good the floor to match the existing complete all as specified and directed.
3
-
-
Takinng down old unserviceable WHB and S&F in repair Vitreous China wash basin, white, oval type excluding taps, waste chain & plug & porcelain stopper but including brackets , wastepipe and coupling, complete all as specified and directed.
6
-
-
Taking down old unserviceable urinal and S&F Vitreous China Urinal white colour, Half stall type,white incl waste pipe complete all as specified and directed.
4
-
-
Taking out old u/s water closet and S&F vitreous China "Orissa pattern" size 580 x 440mm" coloured, with intergral foot rests with vitreous china 'P' or 'S' trap front or back inlet including connection to trap and to flushing pipe, anti syphnage pipe and making good the floor to match the existing complete all as specified and directed.
1
-
-
S&F in repair PVC valve less, syphonic action type flushing cistern, 10 Litre capacity, low level, white with inlet, ball vlave float, handle including PVC rigid pipe 32mm bore as flush pipe fixed on walls by drilling holes and using PVC rawl plug of suitable size complete all as specified and directed.
1
-
-
Taking out old unserviceable looking mirror & S&F looking mirror of 5.5mm thick of selected quality, mounted on PVC frame/stylish design and fixed to and including wooden plugs with chromium plated brass screws washer cup washer complete all as specified and directed.
3
-
-
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
4
-
-
M&L for towel Rail 600mm long of stainless steel chromium plated fixed with and including Chromium plated brassscrews and wooden/plastic cleats(Minimum weight 190gms) complete all as specified and directed.
4
-
-
Taking down old unserviceable PVC connection and S & F PVC connection, heavy duty 15 mm bore, 45 cm long with two Nos PTMT nuts at both ends of approved quality complete all as specified and directed
14
-
-
S&F in repair 110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new PVC clamps complete all as specified and directed.
20
-
-
S&F in repair 75mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new PVC clamps of FI 50 x 3mm complete all as specified and directed.
15
-
-
S&F in repair 110mm PVC (SWR) junction single, (Single T) equal or unequal with access door with cement joint complete all as specified and directed.
4
-
-
S&F in repair 75mm PVC (SWR) junction single, (Single T) equal or unequal with access door with cement joint complete all as specified and directed.
3
-
-
S&F in repair 110mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed.
8
-
-
S&F in repair 75mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed.
5
-
-
S&F in repairs PVC (SWR) floor trap/ Nahani trap 75mm, plain with grating including jointing to waste pipe fixed in cement concrete type (1:2:4) complete all as specified and directed.
10
-
-
S&F in repairs 110mm bore PVC (SWR) vent cowl complete all as specified and direted.
4
-
-
S&F in repairs Chromium plated fancy type Pillar taps15 mm dia, cast copper alloy, with capstan heads,chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
6
-
-
S&F in repairs Chromium plated fancy type Angle stop cock 15 mm dia screwed down light pressure screwed both ends for iron pipe or for union complete all as specified and directed.
15
-
-
S&F in repairs Chromium plated fancy bib taps, with capstan heads, screwed down for iron pipe or for brass ferrule & fixed for 15 mm bore pipe complete all as specified & directed.
5
-
-
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth & applying two coat of synthetic enamel paint of approved quality, tint to achieve glossy finish, complete all as specified and directed.
20
-
-
M & L for preparation of old wooden surface over 10cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of pink primer complete all as specified and directed.
35
-
-
Demolition of cement concrete (unreinforced ) in floors and pavings n. exc 15cm thickness (above or below GL) complete all as specified and directed
9
-
-
M&L PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 75mm thick as in plinth protection finished fair & even laid in alternative bays n. exc 2M in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
120
-
-
Dismantling Asbestos Cement (corrugated, semi corrugated, etc) sheets in roof covering complete all as specified & directed.
20
-
-
S&F 6mm thick asbestos cement corrugated or semi corrugated sheets in roof fixed with L-type or J-type or cranked hook bolts complete all as specified & directed at any height complete all as specified and directed.
20
-
-
M & L for cement concrete (Type B0, 1:2:4, 12.5 mm graded aggregate) in copings, kneelers, apex stones, bed plates, water troughts and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
1
-
-
M&L for brick work with flyash old size bricks, straight or curved on plan exc. 6mm mean radius, built in in cement mortar 1:6.complete all as specified and directed
1.5
-
-
M & L for Fly ash brickwork with sub-class `B`, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
5
-
-
Taking out old unserviceale 1000 ltr water storage tank and S& F rotational moulded water storage tank1000 litre capacity hoisted & fixed in position all as specified in SSR Part-I complete all as specified and directed.
2
-
-
Taking down existing unservicable treatment of any description including cement plaster/conctrete any thickness from roof surface cleaning of roof surfaces and and preparing it for further treatment and removing rubbish from the site up to 02 KMs complete all as specified and directed.
250
-
-
M&L PCC 1:2:4 type B-0 Mixed with water proofing compound as in levelling course over RCC roof surfaces complete all as specified and directed.
2
-
-
For Non-Acessable Roof:- M&L for provn of water proofing roof treatment to RCC roof with APP modifed plain membrane, thickness of membrane not less than 3 mm and weighing not less than 3 kg/sqm comprising with following :-
(a)The surface of roof, parapet and gutters, drain mouths, etc. over which waterproofing treatment is to be applied shall be cleaned of all foreign matter such as, fungus, moss, dust etc by wire brushing and dusting. For cast iron drain out lets a grove shall be cut around to tuck in the treatment. Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) around obstacles such as pipes, chimneystacks, etc. and other similar situation to ease up about corners.incl 10mm thick screed bed in CM 1:4 mix with water proofing compound under Bitumious based Primer conforming to IS: 3384 @ 0.3 Kg/SM to be applied on prepared surface, till the surface is properly impregnated.
250
-
-
Note:for item no 65.00 continue:-
(c) After the application of approved bituminous primer the water proofing membrane shall be laid on the primed surface by torch application method as per manufacturer’s instruction. The overlap while torching shall be 100mm in longitudinal direction and 100mm in transverse direction. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer and seling it with the help of hot trowel. The overlap joints shall be made as a monolithic layer. (d) All joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane.(e)A fillet of PCC (1:2:4) type B-0 of 100x100mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of direction. The membrane should not be taken over at any steep turns and hence all corners/timers should be rounded, Apply two coats of bituminous aluminium paint over APP membrane @ 0.30 Kg/Sqm complete all as per manufacturers instructions. complete all as per manufacturers instructions. after as specified and directed.
-
-
-
Dismantling of ceiling board/lathing and PVC panneling any thickness including frame work complete all as specified and directed.
160
-
-
Providing & Fixing false ceiling with Everest Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30 mm thick sheet, spaced at 1200 mm c/c and cross "T" of size 15x32 mm made of 0.30 mm sheet, 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size15x32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20 mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, all complete at all heights as per direction of Engineer-in-charge.
90
-
-
S&F 5-8mm thick PVC wall cladding hollow cored and a tongue and grooved edge fixed with screw incl required PVC cleat at edges and at corner coplete all as per manufacturer instruction and directed by Engr-in-Charge.
70
-
-
Dismatling of single layer mangalore pattern or similar tiles in roofing complete all as specified and directed.
54
-
-
M&L roof tiles, mangalore pattern interlocking at side joints, laid dry complete all as specified and directed.
50
-
-
M&L ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all as specified and directed.
12
-
-
M & L for dismantling of loose / disintegrated portion of RCC chajjas bend shelves beams balconies and similar work at any position or any height and doubbing out with pcc 1:1.5:3 15 mm to 50 mm thick using 6 to12 mm graded stone aggregate to make up and finished required shape including applying anti corrosive paint on exposed surfaces and provision of ncessory suporting from work and including 10 mm thick plastering in CM 1:4 finished fair and even on concrete/brick masonry surfaces finished even and smooth complete all as specified.
21.5
-
-
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, holders, regulators, sockets etc., removing materials from site and making good disturbed surface of walls, floors etc.
223
-
-
Disconnecting and taking down unserviceable sub main wiring of any size including steel/PVC conduit and accessories & removing from site and making good the disturbed surfaces, complete all as specified and directed.
300
-
-
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets etc for re use at site or carrying to the store(To be measured only when found serviceable in all respects complete for re use.) complete all as specified and directed
280
-
-
M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed cable in and including PVC rigid non metallic conduit medium grade not less than 20mm dia ISI marked and fittings and accessories concealed in walls/roof/ ceiling with suitable size of sunk type pressed steel modular terminal box and modular white cover plate with frame for suitable module as per site requirements for mounting of modular switches, sockets, fan regulator etc and one green colour cable of 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed as earth wire up to common earth and connected to earth for the following, complete all as specified and directed:
-
-
-
All as per item No. 76.00 here-in-before but One light point controlled by one, one way switch.
114
-
-
All as per item No. 76.00 here-in-before but One Ceiling fan/wall fan/exhaust fan controlled by one, one way switch.
26
-
-
All as per item No. 76.00 here-in-before but One three pin 5 Amp socket on same board with other switches.
18
-
-
All as per item No. 76.00 here-in-before but One three pin 5 Amp socket on independent board.
35
-
-
All as per item No. 76.04 here-in-before but with 2.5 Sqmm, for one 5 pin 5/15 Amp socket on independent board including 1.5 Sqmm stranded copper conductor (FRLS) PVC insulated green in colour as continous earth conductor connected to common earth complete all as specified and directed.
30
-
-
S&F of modular switch 1 way 6/10Amp , 1 module, complete all as specified and directed.
167
-
-
S&F of modular switch 1 way 16Amp, 1 module, complete all as specified and directed.
30
-
-
S&F of modular socket 6Amp, 2/3 pin combined 2 module complete all as specified and directed.
53
-
-
S&F of modular socket 6Amp/16 Amp, 2/3 pin combined 2 module complete all as specified and directed.
30
-
-
S&F modular stepped type ceiling fan regulator, 230 volt AC, 2 module, complete all as specified and directed.
10
-
-
S&F ceiling rose surface bakelite 3 terminals 63.5 x 17 mm complete all as specified and directed.
140
-
-
Taking down existing exhaust fan & wall mounted fan and re use at site or carrying to the store(To be measured only when found serviceable in all respects complete for re use.) complete all as specified and directed
8
-
-
S&F exhaust Fans AC single phase 230/240 volts of size 300 mm sweep with louver including connecting with three core flexible copper wire from ceiling rose to connector of fan complete all as specified and directed.
6
-
-
S&F of ventillation fan 250mm sweep non metallic white colour including connecting with three core flexible copper wire from ceiling rose to connector of fan complete all as specified and directed. .
4
-
-
S&F of lamp holder PVC/polycarbonate type with back plate complete all as specified and directed. Make : Cona / SSK / Havells
12
-
-
S&F LED box type tube light fitting 20 watt made up of CRCA sheet with pre wired double sided connections including 1x20 watt retrofit LED tube rod with extruded aluminium body , PC diffuser and inbuilt driver , double sided connection, complete with all accessories internally prewired, complete all as specified and directed.
50
-
-
S&F ceiling fan 1200 mm sweep , 230 Volts, AC , 50 Hz, copper winded motor, BE star rated white colour complete with motor, blade set of three nos , down rod, canopy, shackle assy.
10
-
-
Supply and fixing wall mounted decorative luminarie fitting suitable up to 9/10 Watt LED lamp/filament lamp champagne gold finish fixture with plastic body suitable for B22 Base complete all as specified and directed by Engr-in-Charge.
Make: Havells , Model- LHFOECE1TZ1B014,LHFHANDBTN1K007, LHFOAJE2TZ1I060 and LHFHANDBTN1M007 or equivalent model of Mepro/Philips
14
-
-
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
6
-
-
S&F LED light fittings, 10 W bulk head luminaries 230V, 50 Hz complete with all accessories and including cool day/warm/ white light connecting up with three core copper conductor cable with suitable size complete all as specified and directed.
14
-
-
S&F and testing energy saving street light luminaire 15 watt LED , pressure die cast housing with high power LED as lighting source and lens embedded PC cover with IP 66 protection incl connecting with three core copper flexible wire from ceiling rose to connector of light fitting complete all as specified and directed by Engr-in-Charge.
12
-
-
S&F recess mounted 2' x 2' LED luminarie 36 watt, cool day/warm/ white light with white powder coated CRCA housing with LED driver, efficiencey 100 Lm/w complete all as specified and directed. Make Crompton/Havells/Philips
18
-
-
S&F street light bracket made of 32 mm GI pipe , 1.2 mtr lenght fixed with two nos of clamp , nut and bolts complete all as specified and directed.
12
-
-
M & L for submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 sqmm multi stranded copper conductor cable drawn through and incl 25 mm dia PVC non metallic rigid concealed conduits and the conduits accessories incl one run of green colour earth continuity conductor with 6 sqmm multi stranded copper conductor cable complete all as specified and directed.
150
-
-
M & L for submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 sqmm multi stranded copper conductor cable drawn through and incl 25 mm dia PVC non metallic rigid concealed conduits and the conduits accessories incl one run of green colour earth continuity conductor with 4 sqmm multi stranded copper conductor cable, complete all as specified and directed.
150
-
-
M& L for TV Socket incl PVC conduit and co axial cable wire complete all as specified and directed.
8
-
-
M& L for Telephone socket incl PVC conduit and telephone wire, complete all as specified and directed.
6
-
-
S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB SP `C' series for AC, complete all as specified and directed
14
-
-
S&F in repair of Change over Three Pole Neutral AC 100 Amp, with bolted type fuse in sheet enclosure with fuses complete all as specified and directed.
1
-
-
S&F wall fan of size 300 mm sweep, Speed upto 2100 RPM, Air Delivery 90 CMM, 230/240 volts including connecting with three core flexible copper wire from ceiling rose to connector of fan complete all as specified and directed. Make :-Havells, Bajaj, Usha
20
-
-
S&F in repair recess mounted LED 12 watt Slim, compact, auminum die cast edge lit panel, cool day/warm/ white light and round fixture with opal diffuser and separate electronic driver complete all as specified and directed by Engr-in-Charge. Make Philips Cat No DN193B LED12S-4000 PSU WH S2, Havells Cat Part No INTEGRANEODLR12WLED857S or equivalent in Crompton.
28
-
-
S&F in repair surface mounted LED downlight 18 watt round shaped , Slim surface mounted LED panel with cool day/warm/ white light premium diffuser to ensure glare free & even light distribution complete all as specified and directed. Make Havells, Model -Trim Cosmo Surface Round, Cat Part No LHEAAHP7IL1W018, or equivalent model of Philips/Compton
22
-
-
S&F of vertical TPN distribution board, IP-43 double door metal, 4 way , made out of CRCA sheet steel , factory made powder coated with insulated vertical phase bus bars , shrouded neutral bars, earth bars, colour coded interconecting wire set , blanking plates suitable for up to 125 amp MCCB's as incomer and MCB's SP/TP as outgoing complete all as specified and directed. Make : Legrand/Schneider/Seimens Note: MCB DB, MCCB and MCB's will be of same make.
2
-
-
S&F MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, DB's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 8 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed. Note : MCB DB and MCB will be of same make.
8
-
-
S&F of MCB distribution board TPN 4 way, 415 volts, double door, with 200 Amps rated bus bar, neutral bar with shrouds, earth bar, IP-43 , made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCBs as incomer and outgoing including blanking plate complete all as specified and directed.
2
-
-
S&F of MCB TPN 100 Amp capacity, 415 volt, complete all as specified and directed. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
1
-
-
S&F in repairs MCCB, 100 Amp, 4 Pole, 25 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , including spreader terminals and phase barriers complete all as specified and directed. Make- Legrand/Siemens/Scneider/Havells
1
-
-
S & F of MCB SP, 240 volt, 6 Amp to 40 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
40
-
-
S & F of MCB SP, 240 volt, 63 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
8
-
-
S & F of MCB SPN, 240 volt, 63 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
5
-
-
S&F of MCB TPN, 415 volt, 63 Amp capacity,10 KA, 'C' curve complete all as specified and directed.
2
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI med grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 incl dismantling of old unsv existing earthing, complete all as specified and directed.
4
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core, complete all as specified and directed.
270
-
-
S&F tubes light grade GI tubing 40 mm dia with all fitting laid in trenches, fixed on pole/on wall for cable protection, complete all as specified and directed.
12
-
-
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
27
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
17
-
-
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
10
-
-
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
10
-
-
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
1
-
-
Total in Figures
-
-
-
Quoted Amount in Words
-
-
-