Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 30,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_674172_2Tender No
82425/47/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(ii) Temperature gauge suitable for HVAC system for hot/chilled water water pipeline as existing with accessories.
2
-
-
... More
(iii) Pressure gauge analog type with stainless steel syphon suitable for HVAC plant of capacity upto 45 TR as per existing.
2
-
-
... More
(iv) L.P. cut out
2
-
-
... More
(v) HP cut out
2
-
-
... More
(vi) Oil failure switch
2
-
-
... More
(vii) Oil Pressure Switch
2
-
-
... More
(viii) Compressor oil
30
-
-
... More
All as per item No. 1.00 here-in-above but suitable for compressor unit of 10 TR capacity AC PLANT
3
-
-
... More
Supply only in replacement of following parts/items suitable for 10 TR package type units against item no. 3.
-
-
-
... More
(i) Fan belt s for blower motor as per existing size
4
-
-
... More
(ii) Bearing of shaft of blower
3
-
-
... More
(iii) Complete wiring Resetting of Package Unit
5
-
-
... More
(iv) Dryer filter
5
-
-
... More
(v) Air filter of 10 TR package unit
5
-
-
... More
(vi) LP switch suitable for existing AC plant cap 5/7.5/10 TR (Package type).
2
-
-
... More
(vii) HP switch suitable for existing AC plant cap 5/7.5/10TR TR (Package type).
3
-
-
... More
Supply, fixing, testing and commissioning as in replacement of reciprocating type sealed compressor suitable for existing 5 TR capacity AC plants, 3 Phase, 380-420 Volts, 50 Hz , Thermally protected, complete all as specified and directed.
2
-
-
... More
Supply, fixing, testing and commissioning as in replacement of Scroll type sealed compressor suitable for existing 13 TR capacity AC plants Model No. SZ 18554RC, 380-400 V, 50 Hz thermally protected system volume 31.0L at LP side and 2.0 L at HP side, PS from 25 bar to 31.9 bar, complete all as specified and directed.
3
-
-
... More
Supply, fixing, testing and commissioning as in replacement of PCB assy suitable for 25TR chiller unit complete with display model no SCR 25 TR (MPD) V4 type Delux HMI range 10/7/2 current range 5/30 A Aux supply 0-11VAC, 0-13VAC display (model No. 25TRHMI (5-30A), complete all as specified and directed including programming of PCB all as per existing make & model.
2
-
-
... More
Supply, fixing, testing and commissioning as in replacement of PCB assy suitable for 37.70 TR chiller unit complete with display Sl no DX-3LD-45 unit , complete all as specified and directed.
2
-
-
... More
M&L in servicing of Hot water Generator as per manufacturer norms of capacity 63/24/30 KW 3 steps any make, complete all as specified and directed.
2
-
-
... More
Supply, fixing, testing and commissioning as in replacement of heating coil as per sample of hot water generator of capacity 63 KW model No RC63, 3 steps any make as per sample, complete all as specified and directed.
4
-
-
... More
Material labour for replacement of following parts/items suitable for 10000/14000/4000 CFM capacity AHU unit, complete all as specified and directed.
-
-
-
... More
(i) Contactor 4 pole 40Amps
4
-
-
... More
(ii) Contactor 4 pole 32 Amps
3
-
-
... More
(iii) Temperature gauge suitable for HVAC system for hot/chilled water water pipeline as existing with accessories
2
-
-
... More
(iv) Pressure gauge analog type with stainless steel syphon suitable for HVAC plant of capacity upto 30 TR as existing
2
-
-
... More
(v) Digital Amps meter
5
-
-
... More
(vi) Fan belt for AHU as per existing.
5
-
-
... More
(vii) Thermal Relay 4-16 Amps of existing make
6
-
-
... More
(viii) Three way motorised direct mounted actuator valve complete set 3"/2.5"/4" with all accessories and including piping arrangement, providing connections etc complete as specified and directed by EIC.
Note : cost of welding work for connection and disconnection of valve and pipeline, cost of MS pipe heavy duty of size 3"/2.5"/4" upto 3 mtrs pieces is deemed to be included in quoted rates.
1
-
-
... More
(ix) Thermostat for AHU
2
-
-
... More
Supply and fixing in repair of following spare parts of cooling tower motor of capacity 2HP/3 HP, 3 ph 415 Volts, 50 Hz,
-
-
-
... More
(i) Rotor shaft with rotor
2
-
-
... More
(ii) Bearing as per existing size and model.
2
-
-
... More
(iii) Immersion proof cable gland as existing.
2
-
-
... More
(iv) Connecttion plate
2
-
-
... More
(v) Outer casing with anti corrosion coating on the outside.
2
-
-
... More
Material and labour for descaling of condenser after opening from both side and using the descaling compound and brushes with long iron rod to clean the deposition in side the copper tubes and check the water flow in side the tubes including replacement of gasket set, nuts and bolt, suitable for following capacities, complete all as directed.
Note :- Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction.
-
-
-
... More
(a) 7.5 TR AC Plant.
2
-
-
... More
(b) 35 TR AC Plant.
6
-
-
... More
(c) 10 TR AC Plant
3
-
-
... More
(d) 25 TR AC Plant.
6
-
-
... More
Material and Labour for cleaning, servicing of cooling tower with cleaning agent complete pipe lines, and FRP tank, greasing, servicing of cooling tower, motor and fan & make the necessary alignment , suitable for following capacities, complete all as directed.
Note :- Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction
-
-
-
... More
(a) 20 TR AC Plant.
1
-
-
... More
(b) 15 TR AC Plant.
1
-
-
... More
(c) 50 TR AC Plant.
1
-
-
... More
(d) 70 TR AC Plant.
1
-
-
... More
Material and labour for repair/overhauling of centrifugal monoblock pump set of 5/7.5 HP by opening Gland bush , studs, nuts & washers Ball bearing of pump set Remetling grinding and polishing of pump shaft to required size Gland packing ,replacement of pump bearings and making its proper alignment etc & refixing after repair all as directed .
4
-
-
... More
All as per item No. 15.00 here-in-above but of capacity 10 HP
5
-
-
... More
Disconnecting the electrical connection and taking down the burnt out cooling tower motor of capacity 01/02/03 HP from any location and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as pr existing gauge including replacement of bering & correcting minor defects reassembling, transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified and directed by EIC.
Note :- Contractor must ensure reinstallation of pumpset and make the plant good functioning after rewinding within 48 Hrs of receiving the complaint. Any delay will be imposed as fined of rate Rs 1000 per hour.
4
-
-
... More
Disconnecting the electrical connection and taking down the burnt out monoblock pumpset of capacity 05/7.5 Hp from any location and transporting to workshop for repair, dismantling the pumpset & taking out burnout copper winding and rewinding the same with super enamelled copper wire as pr existing gauge including replacement of bering & correcting minor defects reassembling, transporting monoblock pumpset from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified and directed by EIC.
Note :- Contractor must ensure reinstallation of pumpset and make the plant good functioning after rewinding within 48 Hrs of receiving the complaint. Any delay will be imposed as fined of rate Rs 1000 per hour.
6
-
-
... More
All as per item No. 18.00 here-in-above but of capacity 02/03 HP
4
-
-
... More
All as per item No. 18.00 here-in-above but of capacity 10 HP
4
-
-
... More
Material and Labour for repair/servicing greasing etc of compressor motor capacity upto 7.5/10 HP of repair / replacement of Ball bearing of motor and Remetling grinding and polishing of motor shaft to required size all as directed refixing the same with existing compressor with proper alignment.
4
-
-
... More
Material and Labour for replacement unserviceable sprinkler Assy of Cooling Tower of capacity 45 to 70 TR, complete all as specified and directed.
2
-
-
... More
Supply, installation, testing and commissioning of 125/150 mm dia butterfly valve, class-II, heavy duty for discharge & liquid line, including taking down old u/s butterfly valve, complete all as specified and directed.
3
-
-
... More
All as per item No. 23.00 here-in-above but suitable for 200 mm dia.
3
-
-
... More
All as per item No. 23.00 here-in-above but suitable for 80 mm dia.
3
-
-
... More
All as per item No. 23.00 here-in-above but suitable for 100 mm dia.
3
-
-
... More
Supply and fixing in replacement Gun metal globe or gate valve, suitable for 25mm bore pipe, with iron wheel head, screwed both ends for iron pipe, complete all specified and as directed.
6
-
-
... More
Supply, installation, testing and commissioning of solenoid valve (as per existing make & model), class-II, heavy duty for discharge & liquid line, including taking down old u/s valve, complete all as specified and directed.
1
-
-
... More
Supply & Charging Maffron gas R-22 at Centre & Package type AC plant, complete all as specified and directed.
Note - Nitrogen gas for Leakage detection, if required the cost of N2 gas is deeemed to included in the quoted rate.
120
-
-
... More
Supply & Charging Maffron gas R-407 at Centre & Package type AC plant, complete all as specified and directed.
Note - Nitrogen gas for Leakage detection, if required the cost of N2 gas is deeemed to included in the quoted rate.
80
-
-
... More
Supply and fixing in replacement CT fan blade (made of aluminum) of cooling tower of cap 70/50 TR as per existing size.
2
-
-
... More
Material and labour for replacement of cooling pad /Fills for cooling tower/ air cooling plant including complete fitting as existing at various instalations.
100
-
-
... More
Disconnecting & Taking out old existing unserviceable current transformer of Amp meter of any description and Supply, fixing & testing round/ring type current transformer of ratio 100/5 Amp to 150/5 Amp, rated burden 5 VA and accuracy class 1.0, complete all as specified & directed.
6
-
-
... More
Supply, laying, testing & commissioing, PVC insulated, armoured unsheathed Aluminuim conductor XLPE cable, size 50 Sqmm 3.5 core suitable upto 1100 Volts conforming to IS-694, including disconnecting, dismantling & taking out old existing unserviceable cables of any description & in any position, complete all as specified & directed.
20
-
-
... More
All as per item No. 34.00 here-in-above but cable size 25 Sqmm 3.5 core
20
-
-
... More
All as per item No. 34.00 here-in-above but cable size 10 Sqmm 3 core
20
-
-
... More
Supply and fix in replacement of old unserviceable indicators any type with LED based indicating lamps of RYB colour incl disconnecting and connecting of the same all as directed.
10
-
-
... More
Supply and fix in replacement of single Phase Preventer, type VSP2, suitable for motor protection and making all incoming and out going electric connections complete all a specified and directed.
4
-
-
... More
Supplying and fixing in replacement of AC contactor 3/4 pole, 415 volts current rating 18 A and including making necessary electric connections and testing of circuit on full load complete all as specified and directed.
2
-
-
... More
All as per item No. 39.00 here-in-above but current rating 32 AMPs, 3/4 pole
3
-
-
... More
Taking out old unserviceable MCCBs up to 200 Amp rating and Supply and fixing for MCCB, 4 pole,415Volt, 36 KA including cable lugs of suitable size complete testing, commissioning complete to the entire satisfaction of Engr-in-charge, of 200 Amp capacity.
3
-
-
... More
All as per item No. 41.00 here-in-above but MCCB, 100 Amps,16 KA, 4P, 415V
3
-
-
... More
All as per item No. 41.00 here-in-above but MCCB, 125 Amps, 16 KA, 4P, 415V
3
-
-
... More
All as per item No. 41.00 here-in-above but MCCB, 250 Amps, 36 KA, 4P, 415V
2
-
-
... More
S&F in replacement of overload relay range 4-11 Amp suitable for motor protection with inbuilt earth fault proctection making all incoming and outgoing electric connection complete all as specified and directed.
7
-
-
... More
All as per item No. 45.00 here-in-above but overload relay range 8-22 Amp
3
-
-
... More
All as per item No. 45.00 here-in-above but overload relay range 16-44 Amp
2
-
-
... More
Supply and fix in replacement of timer for motor starter 0-30 sec./3-30 Sec making all incoming and outgoing electric connection complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement air filter of AHU of size as existing suitable for AHU of following capacity :-
(i) 12000 CFM
4
-
-
... More
All as per item No. 49.00 here-in-above but capacity 4000/4200 CFM
4
-
-
... More
All as per item No. 49.00 here-in-above but capacity 10000 CFM
4
-
-
... More
Material and Labour for repairing/servicing / cleaning complete of Air Handiling Unit capacity of 7.5 TR, complete with replacement of worn out /unserviceable parts and rectify the leakages and reassembling the same after complete repair/leakages with accessories as nust, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge
1
-
-
... More
Material and Labour for repairing/servicing / cleaning complete of Air Handiling Unit capacity of 10000 CFM, complete with replacement of worn out /unserviceable parts and rectify the leakages and reassembling the same after complete repair/leakages with accessories as nust, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge
2
-
-
... More
All as per item No. 53.00 here-in-above but capacity 12000 CFM
1
-
-
... More
All as per item No. 53.00 here-in-above but capacity 4200 CFM
1
-
-
... More
M & L for removing existing damaged ducting at several places & Supply, install and commissioning of GSS square/rectangular ducting complete all as per site requirement. (a) 20 gauge (1.0 mm) thick/ 0.8 thick all as per site requirement. Note: Price quoted shall include bending the GSS sheet into existing ducting shape/size along with insulation to be sticked onto the surface of the duct all as specified and directed by engineer-in-charge
30
-
-
... More
S&F in repair, temperature sensor for compressor/chiller unit of central AC plant tube sensor suitable for 25TR chiller or 37 TR chiller all as per existing model with testing and commissioning complete as directed by Engineer-in-Charge.
4
-
-
... More
Supply and fix of flange type High Flow hepa filter(600MM X 600MM) having following specifications: Frame : Aluminium, Media : Micro fibre glass, Sealing of Media: By means of epoxy, Effeiciency: ≥ 99.97 % down to 0.3 Micron particle size,IPD: 31± 10 % mm WG, FPD: 75 mm WG, Separotors: Aluminium, Flange Width: 20 MM Capacity:2000 CFM
8
-
-
... More
M&L for preparation of old painted metal surfaces and applying 1 coat of aluminuim red oxide primer and 2 coats of aluminuim paint complete all as per direction of engineer-in-charge.
60
-
-
... More
M&L of rewinding of blower fan motor of capacity 6000 to 12000 CFM with all accessories required for installing and connection complete all as specified and directed by EIC.
2
-
-
... More
supply and fixing in auto air purge valve of size 15/20/25 mm dia as specified and directed by Engr-in-charge
4
-
-
... More
M&L for attending AC plant faults at MH ICU / OT Cold storage area, to check AC Plant for serviceability of continuous cooling effect rectifying including carrying out minor repairs / replacement etc as required to make AC Plant functional, all as specified and directed by Engr-in-charge. (i) Any other replacement of major items shall be measured & paid separately under respective items of this schedule. (ii) Minor items will be included on the quoted rates only.
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%