Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_695766_1Tender No
84297/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F in repair exhaust fan motor ( heavy duty) , 1400 RPM 450mm copper wire winding for heavy duty desert cooler complete all as specified and directed by the Engineer-in-charge. Make:- Crompton/bajaj/usha/universal
30
-
-
... More
S&F in repair exhaust fan blade ( heavy duty) suitable for heavy duty desert cooler motor which specified in item no -5 complete all as specified and directed by the Engineer-in-charge.
30
-
-
... More
S&F in repair fan motor of 1/7 HP, (2800/1365 RPM) CLASS B , OUT PUT WATTAGE 60/107 approx amp 0.36 to1.0 with copper wire winding suitable for PLASTIC desert cooler AS avaliable at site complete all as specified and directed by the Engineer-in-charge. NOTE-TYPE OF MOTOR WILL BE SAME AS AVALAIBLE ON SITE.
30
-
-
... More
S&F in repair PLASTIC fan blade ( heavy duty) suitable for PLASTIC desert cooler motor which specified in item no -7 complete all as specified and directed by the Engineer-in-charge.
30
-
-
... More
S&F in repair, top of desert cooler , of any capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet including gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair, front side grill of desert cooler of any capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet including gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair, side/back shutter fabric item made out of 1 mm thick galvanised iron sheet of size suitable for desert cooler of air delivery capacity 4000/5000 Cum/hour in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair, corner of the desert cooler made out of 1 mm thick galvanised iron sheet of size suitable for desert cooler height as per the existing (up to 1.2 M) including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair, bottom tank of desert cooler , of any capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet with gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair, Front panel on which Desert cooler motor mounted on inner side and grill will be mounted on front side of panel including the empty switch & regulator box of desert cooler of any capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet including gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S &F in repair, Front plate of desert cooler complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair, PVC flexible pipe of 16 mm outer dia complete for desert cooler complete all as specified and directed by the Engineer-in-charge.
500
-
-
... More
S &F in repair, desert cooler selector switches three way 230 volts single phase complete all as specified and directed by the Engineer-in-charge.
400
-
-
... More
S &F in repair, wood wool pad size of 36" x 24" (Set of three) fixed in three sides panel of desert cooler complete all as specified & directed by Engineer-in-charge.
700
-
-
... More
S&F in repair, plug top 3 pin 5 amps, 230 volts (ISI marked) complete all as specified and directed by the Engineer-in-charge.
340
-
-
... More
S&F in repair switch piano type 240 volts, single pole one way 5 amps complete all as specified and directed by the Engineer-in-charge.
340
-
-
... More
S&F in repair PVC insulated and PVC sheathed round flexible three core copper conducter cable suitable for upto 10 Amp with plug top and 1.5 mtr length minimum complete all as specified and directed by the Engineer-in-charge.
340
-
-
... More
S&F in repair, capacitor suitable for 4000/5000/6000 cfm for fan motor of desert coolers complete all as specified and directed by the Engineer-in-charge.
300
-
-
... More
S&F in repair, submersible pump PVC body 230 volts, 18 W, 1.6 m head.0.025HP of desert cooler complete all as specified and directed by the Engineer-in-charge.
739
-
-
... More
S&F in repair, MS fan blade, powder coated for fan motor of desert cooler 20 inch swee, 5mm thickness complete all as specified and directed by the Engineer-in-charge.
540
-
-
... More
S&F in repair, legs of desert cooler including of nuts& bolts suitable for desert coolers complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair, cast iron ring for desert cooler fan motor with clamps & nuts& bolts suitable for desert complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair, Flexible copper wire of 1.5 sqmm for connection of different item of desert cooler complete including connecting and testing complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair, PVC 2 way elbow distributor suitable for 15 mm flexble pipe with nuts and screws for desert coolers complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair, PVC 3 way distributor suitable for 15 mm flexble pipe with nuts and screws for desert coolers complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair fan motor suitable for water cooler of capacity 40/80 ltr to 150/180 ltr, copper wound complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
12
-
-
... More
S&F in repair condensor coil of water cooler of capacity 40/80 to 150/180 ltr complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
1
-
-
... More
S&F in repairs fan blade suitable for water cooler of capacity 40/80 Ltr to 150/180 liters complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
12
-
-
... More
S&F in repair, Capacitor of any capacity and any type (suitable or as per existing sample) for water coolers/refrigerator/deep freezer complete all as specified and directed by the Engineer-in-charge. Make-As per existing make and model
65
-
-
... More
S&F in repairs float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for 15 mm bore iron pipe, weight not less than 140 grams/each, suitable for water/desert coolers complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repairs any size water tap, cast copper alloy, chromium plated push type suitable for water cooler of any capacity complete all as specified and directed by the Engineer-in-charge.
14
-
-
... More
S&F in repair, relay and over load protector set suitable for water cooler/refrigerator/split ac/deep freezer of any capacity complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
110
-
-
... More
S&F in repair, PVC drain out pipe, heavy duty 32/40 mm dia, wall thickness 2 mm having length not less than 1.0 mtr complete with fittings such as nipple, clip etc complete fixed to water coolers of any capacity complete all as specified and directed by the Engineer-in-charge.
20
-
-
... More
M&L for cutting and removing unservicable freezer unit of refrigerator capacity 165 to 285 Litres of any make, and supply and fix new freezer unit including jointing, brazing, recharging of refrigerant gas NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER and testing for smooth functioning complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
6
-
-
... More
M&L for cutting and removing unservicable freezer unit of refrigerator capacity 285 to 400 Litres of any make, and supply and fix new freezer unit including jointing, brazing, recharging of refrigerant gas NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER and testing for smooth functioning complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
6
-
-
... More
S&F in repairs thermostat suitable for refrigerator/water cooler/deep freezer of ANY capacity complete all as specified and directed by the Engineer-in-charge. Make-Make- As per existing make and model
55
-
-
... More
M&L for servicing of spilt type AC of capacity 1.5/2TR of any make by opening the condenser unit fixed on outside and cooling unit fixed inside the building,and cleaning (Including complete pressurized chemical washing with pressure pump and plastic bag covering avoid dust & water spreading) the complete condensor unit and cooling unit including fins and checking/testing of all parts for its serviceability, and rectification of unusual noise of motors, checking of refrigerant standing pressure, replacement of minor parts such as nut/bolt washers etc and reassembling of complete unit including testing for smooth functioning complete all as specified and directed by the Engineer-in-charge.
320
-
-
... More
M&L for servicing of window type AC of capacity 1.5/2 TR of any make including cleaning of filter on front side by removing dust, cleaning (Including complete pressurized chemical washing with pressure pump and plastic bag covering avoid dust & water spreading)the condenser including fins, blower fan motor and checking/testing of all parts for its serviceability, oilling/greasing to condenser cum blower fan motors, rectification of unusual noise, checking of refrigerant standing pressure, replacement of minor parts such as nut/bolt washers etc. and reassembling of complete AC including testing for smooth functioning complete all as specified and directed by the Engineer-in-charge.
2
-
-
... More
M&L for shifting of window AC of capacity 1.5/2TR of any make by opening the window AC complete with accessories and fittings and transporting the AC to the site where it is to be installed, installing the AC at site in and including making necessary drilling and cutting of window and making proper arrengement for installation of window ac also including checking/testing of all parts for its serviceability and rectification of unusual noise of motors, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete unit including testing for smooth functioning complete all as specified and directed by the Engineer-in-charge.
2
-
-
... More
M&L for shifting of spilt type AC of capacity 1.5/2TR of any make by opening the indoor and outdoor unit complete with accessories and fittings including filling of drilled hole of wall using high quality plaster and transporting the AC to the site where it is to be installed, installing the AC at site in and including making necessary drilling in wall making electrical connections indoor/outdoor unit and checking/testing of all parts for its serviceability and rectification of unusual noise of motors, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete unit including testing for smooth functioning complete all as specified and directed by the Engineer-in-charge.
22
-
-
... More
S&F in repair single pole contactor of any capacity suitable for 1.5/ 2 TR split / window ac of both type AC /DC complete including testing commissioning complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
44
-
-
... More
S&F in repair outdoor / blower fan motor of any capacity and type of copper wound suitable for split type AC1.5 /2 TR, AC/DC complete including testing commissioning complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
13
-
-
... More
Repair to condenser fan motor from window type A/C of 1.5/2 TR capacity, including replacement of gun metal bush, side rubber packing and refixing of motor in original position with new washer nuts & bolts complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
2
-
-
... More
S&F in repair capacitor any capacity and any type (3/ 4 pin/6 pin or existing) suitable for split AC and window ac of both type AC and DC of capacity 1.5/2 TR complete all as specified and directed by the Engineer-in-charge. Make-As per existing make and model
90
-
-
... More
S&F in repair Stand of outdoor unit of split ac with complete nut bolt etc. , suitable for any type of split ac as avaliable on site complete all as specified and directed by the Engineer-in-charge.
20
-
-
... More
Repair/Replacement of refrigerator fan motor suiable of capacity upto 400 ltr complete including testing complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model.
5
-
-
... More
S&F in repair, drain out pipe of split AC of PVC, heavy duty of 15 mm dia and 1.5 mm wall thickness complete with fittings,spacer and saddles etc complete all as specified and directed by the Engineer-in-charge.
85
-
-
... More
S&F in repair, condenser fan blade suitable for window type AC 1.5/2 TR capacity complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
1
-
-
... More
S&F in repair, blower/ outdoor fan blade of any type split type AC 1.5/2 TR capacity complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
13
-
-
... More
S&F in repairs remote control (Micro processor) unit suitable for split type AC 1.5/2 TR capacity complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
10
-
-
... More
Cutting and taking out compressor of window type AC of 2TR and supply and fixing the compressor with jointing of copper refrigerant pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING ccomplete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
1
-
-
... More
Cutting and taking out compressor of window type AC of 1.5 TR and supply and fixing the compressor with jointing of copper refrigerant pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
1
-
-
... More
S&F in repair, of thermostat suitable for split/window type AC 1.5/2 TR capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
36
-
-
... More
Cutting and taking out compressor of split type AC of 1.5 TR and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
15
-
-
... More
Cutting and taking out compressor of split type/ Cassette AC of 2TR and supply and fixing the suitable compressor with jointing of copper refrigerant pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
8
-
-
... More
S&F in repair, copper condenser coil suitable for split/Cassete type AC of capacity 1.5 TR complete including top up gas charging and checking complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
2
-
-
... More
S&F in repair, copper condenser coil suitable for split/Cassete type AC of capacity 2 TR complete including top up gas charging and checking complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
1
-
-
... More
S&F in repair, copper condenser coil suitable for window type AC of capacity 1.5 TR complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
1
-
-
... More
S&F in repair, copper condenser coil suitable for window type AC of capacity 2 TR complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
1
-
-
... More
S&F in repair, plug top three pin 15/16 Amps 230 volts AC complete all as specified and directed by the Engineer-in-charge.
33
-
-
... More
S&F in repair, Air Filter for Air conditioner split type having capacity1.5/2.0 ton (Set of 3 pieces) complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
13
-
-
... More
S&F in repair, PCB suitable to Split/Cassette type AC 2 TR complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
5
-
-
... More
S&F in repair, PCB suitable to Split/Cassette type AC 1.5 TR complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
7
-
-
... More
S&F in repair,INDOOR PCB suitable for DC invertor type Split/Cassette type AC 2 TR complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
2
-
-
... More
S&F in repair,INDOOR PCB suitable for DC invertor type Split/Cassette type AC 1.5TR complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
2
-
-
... More
S&F in repair,OUTDOOR PCB suitable for DC invertor type Split/Cassette type AC 2 TR complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
2
-
-
... More
S&F in repair,OUTDOOR PCB suitable for DC invertor type Split/Cassette type AC 1.5TR complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
2
-
-
... More
S&F in repair, PCB suitable to window type AC 1.5/2 TR complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
1
-
-
... More
S&F in repair, PCB suitable to invertor refrigerator to any capacity complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
2
-
-
... More
S&F in repair copper tube size 1/4" of split AC having capacity 1.5/2 ton complete with PUF insulation complete all as specified and directed by the Engineer-in-charge.
70
-
-
... More
S&F in repair copper tube size 1/2" of split AC having capacity 1.5/2 ton complete with PUF insulation complete all as specified and directed by the Engineer-in-charge.
70
-
-
... More
S&F in repair copper tube size 3/8" of split AC having capacity 1.5/2 ton complete with PUF insulation complete all as specified and directed by the Engineer-in-charge.
10
-
-
... More
S&F in repair insulation for copper tube suitable for split AC 1.5/2 TR complete complete all as specified and directed by the Engineer-in-charge.
150
-
-
... More
S&F in repair for indoor motor of any type and any capacity for suitable of split AC of both type AC and DC any make any type all as per sample complete all as specified and directed by the Engineer-in-charge.
4
-
-
... More
S&F in repair for split AC valve of ½” dia all as per sample complete all as specified and directed by the Engineer-in-charge.
40
-
-
... More
S&F in repair for split AC valve of ¼” dia all as per sample complete all as specified and directed by the Engineer-in-charge.
40
-
-
... More
S&F in repair for split AC valve of 3/8” dia all as per sample complete all as specified and directed by the Engineer-in-charge.
10
-
-
... More
S&F in repair, condensor fan motor for deep freezer of any type and any capacity complete suitable for deepfeezer complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
2
-
-
... More
Cutting and taking out compressor of deep freezer of capacity 150 to 210 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in andincluding charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
4
-
-
... More
Cutting and taking out compressor of deep freezer of capacity 210 to 380 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in andincluding charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
6
-
-
... More
Cutting and taking out compressor of water cooler of capacity 40/80 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
7
-
-
... More
Cutting and taking out compressor of water cooler of capacity 60/120 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
7
-
-
... More
Cutting and taking out compressor of water cooler of capacity 150/180 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
4
-
-
... More
Cutting and taking out compressor of refrigerator(ordinary/invertor type) of capacity 285 to 400 litres of any make, & replacing the same compressor with new of same make of model complete, re-installing in original position with all accessoriesincluding charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
5
-
-
... More
Cutting and taking out compressor of refrigerator(ordinary/invertor type) of capacity 165 to 215 litres of any make, & replacing the same compressor with new of same make of model complete, re-installing in original position with all accessories including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
6
-
-
... More
Cutting and taking out compressor of refrigerator (ordinary/invertor type)of capacity 220 to 280 litres of any make, & replacing the same compressor with new of same make of model complete, re-installing in original position with all accessories including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model
4
-
-
... More
S&F in repair, capillary tube with filter suitable for any make & capacity water cooler/refrigerator/ AC complete all as specified and directed by the Engineer-in-charge. Make- As per existing make and model.
100
-
-
... More
Supply & charging of refrigerant gas R-22 (freon) for charging in Refrigerator/water cooler/DF/ window/split type AC of 1.5/2 TR capacity complete and checking of leakage, testing for proper functioning complete all as specified and directed by the Engineer-in-charge. Note : Measurement of Gas cylinder to be done in the presence of JE/Engr-in-charge and daily usage record to be maintained at the time of leaving the station.
230
-
-
... More
Supply & charging of refrigerant gas R-410A for charging in Refrigerator/water cooler/DF/ window/split type AC of 1.5/2 TR capacity complete and checking/testing for proper functioning complete all as specified and directed by the Engineer-in-charge. Note : Measurement of Gas cylinder to be done in the presence of JE/Engr-in-charge and daily usage record to be maintained at the time of leaving the station.
107
-
-
... More
Supply & charging of refrigerant gas R-134C (freon) for Refrigerator/water cooler/DF/ window/split type ACs of any capacity complete and checking/testing for proper functioning complete all as specified and directed by the Engineer-in-charge. Note : Measurement of Gas cylinder to be done in the presence of JE/ Engr-in-charge and daily usage record to be maintained at the time of leaving the station
175
-
-
... More
Supply & charging of refrigerant gas R-32 (freon) for Refrigerator/water cooler/DF/ window/split type ACs of any capacity complete and checking/testing for proper functioning acomplete all as specified and directed by the Engineer-in-charge. Note : Measurement of Gas cylinder to be done in the presence of JE/ Engr-in-charge and daily usage record to be maintained at the time of leaving the station
104
-
-
... More
Supply & charging of refrigerant gas 600A for refrigarator/water cooler of any capacity complete and checking/testing for proper functioning complete all as specified and directed by the Engineer-in-charge. Note : Measurement of Gas cylinder to be done in the presence of JE/Engr-in-charge and daily usage record to be maintained at the time of leaving the station.
22
-
-
... More
S&F in repair MCB SP 25 Amps protected plug top & socket, cat no-Havells DBOXx , 240 Volts complete all as specified and directed by the Engineer-in-charge.
38
-
-
... More
supplying and laying of 16 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings in trenches complete all as specified and directed by the Engineer-in-charge.
80
-
-
... More
S&F IN REPAIR self closing taps of 15 mm inner dia of cast iron or malleable cast iron , galvanised screwed for iron pipe and fixed complete all as specified and directed by the Engineer-in-charge.
30
-
-
... More
S&F in repair Stop cock of 15mm dia complete all as specified and directed by the Engineer-in-charge. Make: Make as per exixting at site
50
-
-
... More
S&F in replacement of PVC connection pipe 15mm dia of both ends PTMT nuts and 450mm length complete all as specified and directed by the Engineer-in-charge.
50
-
-
... More
S&F in repair NRV VALVE for Refrigerator/water cooler/DF/ window/split type AC of any capacity complete all as specified and directed by the Engineer-in-charge.
110
-
-
... More
S&F in repair voltage stablizer of 5-KVA suitable for split/ window ac of 1.5/2 TR complete all as specified and directed by the Engineer-in-charge. Make-V-GUARD/MICROTECH/PIXELS
21
-
-
... More
S&F in repair flexible copper cable of 2.5 sqmm 3- core complete suitable for split ac complete all as specified and directed by the Engineer-in-charge.
100
-
-
... More
S&F in repair bottom tray of window ac of 1.5/2 TR complete all as specified and directed by the Engineer-in-charge.
1
-
-
... More
S&F in repair FAIR NUTS of any size for window/split type AC of any capacity complete all as specified and directed by the Engineer-in-charge.
30
-
-
... More
M&L in replacement indoor unit suitable for 1.5 ton split air conditioner complete all as specified and directed by the Engineer-in-charge.
5
-
-
... More
M&L in repair/servicing for voltage stablizer including removing from the wall and after repairing fixing the same at same location complete all as specified and directed by the Engineer-in-charge.
55
-
-
... More
Labour only for attending split ac/ refrigrator/deep freezer/ water cooler etc complaints.including minor repair such as leakage recitfication of copper condensor tubes and copper tubes, brizing etc. complete all as specified and directed by the Engineer-in-charge.
529
-
-
... More
M&L in repair for outdoor unit (casing) suitable for 1.5 tone split AC ( with out compressor). MS body, self standing.including condensor, suction& dischage valve,,fan motor,fan blade,capaliary filter,connecting copper tube and connector with connecting wiring kit complete all as specified and directed by the Engineer-in-charge.
5
-
-
... More
The above all Items Quoted rates shall to be included :-
(a) As the above work is required to be carried out for repair/maint of cooling appliances entire Mil Stn Jaisalmer , hence complaints of the US equipment’s (Desert coolers/refrigerators (ordinary/inverter)/DF/ACs (ordinary/inverter)/ water coolers/voltage stabilizers) to be handed over daily basis for different units locations and repairs to be carried out on the same day or next day or as directed by Engr-in-Charge.
(b) The contractor shall depute adequate AC mechanic and helper (As per the complaint) with all connected tools on daily basis with suitable vehicle arrangement to repairs and attend the complaints in various units under AOR of GE (A) Jaisalmer and manage all spares included in this CA in advance or as directed by Engr-in-Charge. (c) Non attending the complaints with in 48 hrs Rs 200/- per day per complaints shall be recovered. (d) the contractor should print complaint slip in prescribed formate as specified by engg-in-charge at the starting of the contract
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%