Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Dec 2024
Closing Soon10 Jan 2025
Tender Amount₹ 18,38,000
Costs
EMD
₹ 36,760Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair/maint Of Mechanical Laundry, Fire Fight Equipment, Lift And Connected Works Under Ge (a) Suratgarh
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_662316_3Tender No
CA No CWE BKN-Token No 01/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Inspection & checking of Flat work ironer front feed and rear return type and finding of fault by checking control devices, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including making connections complete all as specified and as directed.
1
-
-
... More
Inspection & checking of flat body press machine and finding of fault by checking control devices, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including making connections complete all as specified and as directed.
2
-
-
... More
Inspection & checking of air compressor and finding of fault by checking control devices, safety devices, pipeline, nut bolts, washers, gauges, pressure line leakages, hose pipe etc., removing the defects and refixing in its original position including making connections complete all as specified and as directed.
Notes for serial item No 1.00 to 6.00 : (i) All spare parts for repair shall be procured from manufacturer’s authorised dealer only. (ii) All tools, testing instruments shall be arranged by the contractor including necessary transport. (iii) The fixing/labour element for spare parts required to be replaced shall deemed to be included in quoted rates of this item and spare parts shall be measured and paid for separately as “Supply only” under respective items of this Schedule. (iv) Testing of the boiler by authorised in presence of GE & Engineer-in-Charge & certificate to be submitted before making the payment.
2
-
-
... More
Supply only SS seal bush
5
-
-
... More
Supply only PLC front Panel (ST2002)
1
-
-
... More
Supply only housing ring
3
-
-
... More
Supply only Anabond
5
-
-
... More
Supply only Flexible Pipe (Size: 1/2" X 1mtr.).
8
-
-
... More
Supply only Temperature Controller for boiler and washing machine.
2
-
-
... More
Supply only Probe for Temperature Controller for boiler
1
-
-
... More
Supply only Steam Trap 1/2" for boiler
6
-
-
... More
Supply only bearing RVWE30 Big (bearing NU213).
5
-
-
... More
Supply only bearing RVWE30 Small (bearing 6311).
5
-
-
... More
Supply only mechanical seal RVWE30 (shaft seal 85mm jhon crane).
5
-
-
... More
Supply only oil seal RVWE30.
5
-
-
... More
Supply only Emergency switch red.
2
-
-
... More
Supply only indicator red.
3
-
-
... More
Supply only transformer 415/220 V AC tumble drier.
2
-
-
... More
Supply only pump cylinder (pump bottle).
2
-
-
... More
Supply only NRV as per sample or required at site for boiler.
4
-
-
... More
Supply only data cable
1
-
-
... More
Supply only Pneumatic Valve for (Y - Type, Size : 2")
1
-
-
... More
Supply only Globe gate Valve 1".
1
-
-
... More
Supply only Drain Valve for 30 KG.
2
-
-
... More
Supply only Air solenoid valve.
10
-
-
... More
Supply only Push Button.
2
-
-
... More
S&F in replacement MS Pipe, heavy grade, 20mm bore, ISI marked, including all fittings complete all as specified and as directed.
30
-
-
... More
S&F in replacement MS Pipe, heavy grade, 25mm bore, ISI marked, including all fittings complete all as specified and as directed.
15
-
-
... More
Inspection/checking and calibration of weighing machine of capacity 30 Ton by checking/ repairing all the connections and cleaning of load beam cell, etc to make the machine serviceable and to measure actual weight by replacing defective parts, if any, complete all as specified and directed. Notes : The Cost of parts if repalced deemed to be included in item rate only.
1
-
-
... More
Comprehensive Maintenance of Lifts (03 Numbers) installed at ‘A’, ‘C’ & ‘D’ Block of Military Hospital from Ground Floor to Second Floor (G+2), automatic closing door type of "EVAAN" Make, electrically operated automatic passenger lifts of load capacity 884 Kg (Minimum) – 01 No. & 1020 Kg (Minimum) – 02 Nos. & Lifts and its control safety system with automatic steel sliding doors (Both car and landing), rated speed 1 metre per second & 0.50 metre per second, operated with simplex full collective / selective (SCS) control and Variable Voltage Variable Frequency (VVVF) control drive system to serve lift, keeping the Lifts and its accessories in perfect condition with the repair / replacement of all defective / worn out spare parts / components, lubricating etc complete all as specified and directed.
Notes:- 1. Quoted rates of above item includes the following :-
(a) The cost of all perishable spare parts recommended by the OEM required for repair/ replacement for maintenance of lifts to be replaced during comprehensive maintenance.
2. Complete replacement of following major assemblies shall not be covered in the comprehensive maintenance. However, running repairs and replacement of parts of said assemblies are included in rate quoted for this item and cost of labour element for replacement of materials shall deemed to be included in this item. Decision as to whether these major assemblies need complete replacement or not shall be decided by Garrison Engineer, whose decision shall be final and binding.
(i) Traction Machine (ii)Travelling cables (iii) ARD (iv) Car and landing doors
(v) Gear Assembly
(g) The make of spare parts shall be approved by GE and actual quantity for various spare parts required for replacement shall be ascertained by the GE / Engineer-in-Charge. Supply only of following spare parts for above Lifts.
4
-
-
... More
(Contd serial item No. 33 here-in-before)
(h) Any rescue/breakdown shall be attended and experience towards repair/replacement / manpower T&P required shall be deemed to be included in unit rates quoted by the tenderer. (j) Each lift shall be got inspected by the Govt Lift Inspector once in a contract period for the worthiness certificate in respect to safety etc. and cost for which shall also be accounted in unit rates quoted by the tenderer.
(k) In the event of failure of lift, repair action should be attended within 03 hours from registering the complaint. In case, contractor fails to repair the defects within the stipulated time, a penal recovery shall be effected as mentioned here-in-after in Particular Specification Section-II.
(l) Cabin Fan, emergency light inside the cage and exhaust fan inside the machine room for all lift shall be functional round the clock otherwise penal recovery shall be effected @ Rs. 60/- per day per lift after 24 hours for the inconvenience for above mentioned any item from contractor’s payment.
(m) The contractor shall stock sufficient parts/ major assembly to ensure putting the lift in working condition in shortest possible time to avoid inconvenience to users. Make: as per existing make and model/type matching with existing Lift.
-
-
-
... More
Supply only sensor with RX / TX with controller power supply and wiring.
2
-
-
... More
Supply only C.O.P push button suitable for passenger lift.
2
-
-
... More
Supply only Landing car button suitable for passenger lift.
2
-
-
... More
Supply only Car Gate Switch suitable for passenger lift.
1
-
-
... More
Supply only Door operator drive controller power unit.
2
-
-
... More
Supply only Break oil.
6
-
-
... More
Supply only Variable Voltage Variable Frequency (VVVF) drive 12.5 HP 380/480 Volts AC 50 Hz, preprogrammed as per existing Lift Make: Schneider.
2
-
-
... More
Supply only Rectifier card 110 V - 24 V output.
1
-
-
... More
Supply only SMPS Card.
2
-
-
... More
Supply only Main control Card.
1
-
-
... More
Supply only Transformer Card, AC 110 Voltage.
1
-
-
... More
Supply only Relay Board.
1
-
-
... More
Supply only Timer card.
1
-
-
... More
Supply only Gate lock switch.
2
-
-
... More
Supply only Gate lock spring.
2
-
-
... More
Supply only MOM Card
1
-
-
... More
Supply only Control Transformer
2
-
-
... More
Supply only track roller
6
-
-
... More
Supply only track incentary
6
-
-
... More
Supply only door shoe
18
-
-
... More
Supply only door belt / door rope
6
-
-
... More
Supply only Infra red sensor
2
-
-
... More
Supply only door coupler assembly
2
-
-
... More
Supply only final limit
2
-
-
... More
Supply only emergency alarm
1
-
-
... More
Supply only break liner
2
-
-
... More
Supply only Main Hoist Rope of traction steel, atleast 19 strands wound about a core centre, circumference of rope 13 mm, factor of safety as given in relevant IS code with end nut lock complete all as specified and directed.
120
-
-
... More
Supply only divertor pulley
2
-
-
... More
S&F in replacement of LED down light fitting, 12 Watt recess mounted (for ceiling cutout dia150 mm), white 6000k in pressure die cast aluminium luminaire in powder coated white finish in round profile with seperate electronic driver with fixing frame and all eletrical connection complete all as specified and directed.
2
-
-
... More
M&L for rewinding of motor for cabin fan 60 Watt single phase with replacement of unserviceable bearing, connector, pvc cable, etc complete all as specified and directed.
2
-
-
... More
M&L for rewinding of motor 10 / 12.5 HP three phase with replacement of unserviceable bearing, connector, pvc cable, terminal plate etc. complete all as specified and directed.
2
-
-
... More
Repair/overhauling to ARD system of lift by replacement to unserviceable control card, dry cell battery etc to make ARD serviceable and testing complete all as specified and directed. Note: Dry cell battery shall be measured and paid for seperately.
2
-
-
... More
Supply only battery dry cell type 12 volts, 7 AH of elevator Automatic Rescue Device (ARD) with electrical connection complete all as specified and directed.
2
-
-
... More
Supply only battery dry cell type 12 volts, 12 AH of elevator Automatic Rescue Device (ARD) with electrical connection complete all as specified and directed.
2
-
-
... More
M&L for repair to Variable Voltage Variable Frequency (VVVF) drive, 10/12.5/15HP, including repairing/ replacement of main control cord, IGBT card, diode, capacitor, rectifier, testing & re-fixing, software installation complete all as specified and directed.
1
-
-
... More
S&F in replacement 01 HP motor Pump for Boiler having 600 PSI, 12 LPM (litre per minute) function capacity having 950 RPM as per ISO 9001:2008 CO as revised time to time complete all as specified and directed.
1
-
-
... More
M&L for preparation of old surfaces of Boiler chimeny for painting with two coats of aluminium anti corrosive paint of first quality after one coat of red oxide complete all as specified and as directed.
1
-
-
... More
S&F in repair transformar PRI 230 Volt 1,2A, 50 HZ for Boiler complete all as specified and as directed.
1
-
-
... More
S&F in repair Mother Board (Card) for Washer Extractor of Cap 30 Kg complete all as specified and as directed.
1
-
-
... More
M&L for Trumbler Drier machine, findng of fault by checking control devices & removing the defects and refixing in its original position including making functional complete all as specified and directed.
1
-
-
... More
Repair to centrifugal pump capacity 20 HP by disconnecting from motor and pipe, strip opening the pump and replacement of unserviceable parts such as impeller, bushes, shaft sleeves, ball bearing, nut bolts, gland plate, gasket, water hose pipe etc and lathe work/turning, grinding etc on shaft and shaft key way as required including greasing/oiling and re-assembling at the same location with proper alignment with motor and testing complete all as specified and directed.
Note :- (i) Major items like impeller, bearing, bush, gland plate, tyre coupling, coupling assembly shall be measured and paid for separately under respective items of BOQ as “Supply only”.
(ii) Cost for transportaion to workshop and carry back to site after repair is inlcuded in the unit rate of item nothing extra shall be paid on this acount.
2
-
-
... More
Supply only CI impeller suitable for centrifugal Pump set capacity 20 HP complete all as specified and directed.
1
-
-
... More
Supply only Stainless steel Bush suitable for centrifugal Pump capacity 20 HP complete all as specified and directed.
2
-
-
... More
Supply only Gland plate suitable for centrifugal Pump capacity 20 HP complete all as specified and directed.
1
-
-
... More
S&F in replacement Rubber tyre for coupling suitable for centrifugal Pump set capacity 20 HP motor including replacement of unserviceable nut, bolt and washer complete all as specified and directed.
2
-
-
... More
S&F in replacement Ball bearing suitable for centrifugal Pump / motor capacity 20 HP with proper T&P / bearing puller and lathe work on shaft of pump / motor as required and testing complete complete all as specified and directed.
Make : NBC/SKF/TATA
2
-
-
... More
M&L for repair to foot valve of 100mm/ 150mm size by disconnecting from pipe line and replacement of cast iron door plate assembly, hinge pin / disc guide pin, rubber door face and rubber gasket and fixing on same location and testing complete all as specified and directed.
2
-
-
... More
S&F in replacement single outlet hydrant valve size 63mm instantaneous, gun metal body, ISI marked with flanged inlet, CI hand operating wheel and end caps with chain complete all as specified and directed. Make :- Kartar / Leader
2
-
-
... More
S&F in replacement double outlet fire hydrant valve size 63mm instantaneous, gun metal body, ISI marked with flanged inlet, CI hand operating wheel and end caps with chain complete all as specified and directed. Make :- Kartar / Leader
1
-
-
... More
S&F in replacement of fire hose Box, double door with 4 mm thick glass, for storing two nos of 15 mtr hoses and one nozzle, made in 18 SWG CRCA sheet, weather proof, finished with red colour paint fixed on wall complete all as specified and directed.
1
-
-
... More
S&F in replacement of Fire Hose, size 63 mm, ISI marked, 15 mtr long, with male and female coupling complete and conneted to existing system complete all as specified and directed.
2
-
-
... More
S&F in replacement of hose reel drum with stainless stell side body, swinging type, ISI marked, including seamless hose reel tube 30 Mtr long, size 20 mm dia. with nozzle and ball valve, fixed on wall with wall bracket and inlet connection complete complete all as specified and directed.
3
-
-
... More
S&F in replacement of 65mm instantaneous male pressure test cap gauge, copper alloy with bleeder valve complete all as specified and directed.
4
-
-
... More
S&F in replacement of fire hydrant branch nozzle, gun metal, 63 mm, complete all as specified and directed.
2
-
-
... More
S&F in replacement of 150mm dia butterfly valve complete all as specified and directed.
2
-
-
... More
S&F in replacement of 100mm dia butterfly valve complete all as specified and directed.
2
-
-
... More
S&F in replacement Cast iron non return valve / reflux valve with rubber seat flanged type with by pass arrangement suitable for 150mm bore pipe, ISI marked, class PN-1.6 conforming to IS- 5312/2004 with stainless steel spindle, CI gate with brass nuts, bolts, washers and jointing with necessary ruber gasket etc complete all as specified and directed.
2
-
-
... More
Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 10 Sqmm, 3 core complete all as specified & as directed.
120
-
-
... More
M&L for disconnecting all electrical and pipe line connection connected to Diesel Engine of capacity 69 bhp Make : Kirloskar Model Type: RB-44, 1500 RPM, unit carefully for finding out the defects and servicing including replcement of the unserviceable parts, fuel filter, air filter, oil filter, Fan belt, Hose pipe set, engine oil, coolent, bearings complete and refixing the same in original position couple with pumpset and connecting the pipe line testing complete all as directed by Engr-in-charge. Note: The rate inculdes the replacement of air filter, oil filter, fuel filter, fan belt, hose pipe, engine oil, coolent, bearing etc. Nothing extra shall be paid on this account.
1
-
-
... More
S&F in replacement of lead acid battery, 12 Volts, 180 AH, low maintenance with initially full charged alongwith electrolyte and testing complete all as specified & as directed. Make : Amaron/Exide/Luminous
1
-
-
... More
S&F in replacement battery lead connection made out of PVC insulated single core 25 sqmm size 1.5 mtr long inlcuding one end with copper lug and other end with a brass terminal with nut bolt and washer complete all as specified & as directed.
1
-
-
... More
S&F in replacement of industrial pressure switch for water flow system including control wiring complete all as specified & as directed
Make: Indfos
2
-
-
... More
S&F in replacement of water pressure gauge stenless steel body for (0-220 psi) complete all as specified & as directed.
4
-
-
... More
M&L for checking all electrical and control wiring for fire fighting electrical panel for smooth functioning and automatic start and stop of fire fighting system and rewiring of control system of presure switches, contactor of motor for c/f pump/ jockey pump and diesel engine and testing as per OEM complete all as specified & as directed.
Notes: (i) The unit rate includes the replacement of minor parts like control copper wiring, lugs/ thimbles/ nut bolts, washer, dressing etc. Nothing extra shall be paid on this account.
(ii) Replacement of major parts like, MCCBs, contactors, relay, timer, pressure switches, voltmeter, ammeter etc will be measured and paid seperately.
1
-
-
... More
S&F in replacement of power contactor, AC3 rating, 200 Amps, 3 Pole, AC control with Auxiliary contacts NO/NC, adblock complete with all control wiring and including any alteration to existing panel for fixing of the contactors complete all as specified & as directed. Make: Schneider/ L&T/ Siemens
2
-
-
... More
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 160 Amps complete all as specified & as directed.
2
-
-
... More
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 120 Amps complete all as specified & as directed.
2
-
-
... More
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 95 Amps complete all as specified & as directed.
1
-
-
... More
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 65 Amps complete all as specified & as directed.
2
-
-
... More
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 40 Amps complete all as specified & as directed.
2
-
-
... More
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 32 Amps complete all as specified & as directed.
2
-
-
... More
All as per serial item No 98.00 here-in-before but power contactor AC3 rating 9 Amps complete all as specified and directed;
3
-
-
... More
Supply and fixing in replacement of landing header with glass door for lift at 184 MH complete all as specified & as directed.
1
-
-
... More
Supply and fixing in replacement of travelling cable and other wiring of lift at 184 MH complete all as specified & as directed.
1
-
-
... More
S&F in replacement of thermal over load relay adjustment range 66-110 amps with all electrical wiring complete all as specified & as directed.
1
-
-
... More
All as per serial item No 108.00 here-in-before but adjustment range 48-65 Amps complete all as specified and directed.
2
-
-
... More
All as per serial item No 108.00 here-in-before but adjustment range 17-25/ 23-32 / 30-40 / 37-50 Amps complete all as specified and directed.
2
-
-
... More
All as per serial item No 108.00 here-in-before but adjustment range 12-18 Amps complete all as specified and directed.
2
-
-
... More
S&F in replacement of star delta timer 3 sec - 120 sec, 415 Volts with control wiring complete all as specified & as directed by Engineer-in-charge.
2
-
-
... More
S&F In replacement of single phase preventor (SPP) with auto reset, 415 Volts AC, with control wiring complete all as specified & as directed.
1
-
-
... More
Taking out electric motor, 415 Volts, AC, capacity upto 20 HP by disconnecting from exisitng pumpset including electrical connection and taking out from foundation and dismantling the same for servicing and replacement of unserviceable parts such as ball bearing, rewinding, teminal plate with coper, copper lugs/ washer, nut bolts etc and other connected minor parts and including any welding, grinding and finishing work on rotor and reassembling, re-installing at same location and proper alignment and all electrical connection and testing complete all as specified & as directed.
Note:- (i) Transportation of motor to civil workshop, if required, is included in the unit rate of items nothing extra shall be paid on this account.
2
-
-
... More
M&L for taking out defective non-clog sewage submersible pump set of capacity 7.5 HP/10 HP from sewage well with proper T&P chain pulley as required and rewinding of unserviceable motor with supper enamelled copper winding wire of existing gauge inlcuding varnish, baking, and replacement of unserviceable parts i.e. bearing, impeller, key, thrust bearing etc. and refixing of the same and testing complete all as specified & as directed.
5
-
-
... More
M&L for taking out defective non-clog sewage submersible pump set of capacity 12.5 HP/15 HP from sewage well with proper T&P chain pulley as required and rewinding of unserviceable motor with supper enamelled copper winding wire of existing gauge inlcuding varnish, baking, and replacement of unserviceable parts i.e. bearing, impeller, key, thrust bearing etc. and refixing of the same and testing complete all as specified & as directed.
2
-
-
... More
Supply only water seal for submersible sewage pumpset of capacity 7.5 /10 HP as per existing type complete all as specified & as directed.
1
-
-
... More
Supply and fixing in replacement of SS 304 cabin for lift including dismentling of existing cabin complete all as specified & as directed.
1
-
-
... More
Supply and fix in replacement of car header with glass door & door operator for lift including dismentling of existing car header and glass door complete all as specified and directed.
1
-
-
... More
Supply and fix in replacement of cabin /car operating panel for lift including dismentling of existing COP complete all as specified and directed.
1
-
-
... More
Supply and fix in replacement of landing operating (LOP) for lift including dismentling of existing LOP complete all as specified and directed.
3
-
-
... More
Supply and fix in replacement of Automatic Rescue Device ( ARD ) 7.5 HP for lift at 184 MH complete all as specified and directed.
1
-
-
... More
M&L for painting of fire fighting system (184 MH) complete inclduing piping network, hydrant, hose box and other conected items by nozzle spray with sythetic enamel weather proof good quality paint red colour or existing colour code after preparing of old surface by srcapping/rubbing and marking complete all as specified & as directed.
1
-
-
... More
M&L for monthly Periodical maintenance and replacement of unserviceable alarm system/ spare parts of fire alarms cum detection systems installed at Military Hospital complete all as specified & as directed.
11
-
-
... More
S&F in replacement addressable manual call point, resettable type, IP-24, ISI marked with all electrical connection and fix on wall complete all as specified & as directed.
4
-
-
... More
S&F in replacement fire alarm (bell), 24 V DC, ISI marked with all electrical connection and fix on wall complete all as specified & as directed by Engineer-in-charge.
2
-
-
... More
S&F in replacement of fire alarm panel, 16 Zone matching with existing panel and control system with isolate and test function with all electrical connection and testing complete all as specified & as directed.
1
-
-
... More
S&F in replacement of fire alarm panel, 10 Zone matching with existing panel and control system with isolate and test function with all electrical connection and testing complete all as specified & as directed.
2
-
-
... More
S&F in replacement of fire alarm panel, 8 Zone matching with existing panel and control system with isolate and test function with all electrical connection and testing complete all as specified & as directed.
2
-
-
... More
S&F in replacement of fire alarm panel, 6 Zone matching with existing panel and control system with isolate and test function with all electrical connection and testing complete all as specified & as directed.
2
-
-
... More
Taking down fire alarm panel 3 Zone for finding out the defects and repair work by replacement of unserviceable items as battery, swithces, display, microprocessor control card/ ICs/LED indicators etc. and other connected parts and refixing the same in original position complete and testing complete all as specified & as directed.
1
-
-
... More
Taking down fire alarm panel 6 Zone for finding out the defects and repair work by replacement of unserviceable items as battery, swithces, display, microprocessor control card/ ICs/LED indicators etc. and other connected parts and refixing the same in original position complete and testing complete all as specified & as directed.
2
-
-
... More
Taking down fire alarm panel 8 Zone for finding out the defects and repair work by replacement of unserviceable items as battery, swithces, display, microprocessor control card/ ICs/LED indicators etc. and other connected parts and refixing the same in original position complete and testing complete all as specified & as directed.
1
-
-
... More
Taking down fire alarm panel 10 Zone for finding out the defects and repair work by replacement of unserviceable items as battery, swithces, display, microprocessor control card/ ICs/LED indicators etc. and other connected parts and refixing the same in original position complete and testing complete all as specified & as directed.
6
-
-
... More
Taking down fire alarm panel 16 Zone for finding out the defects and repair work by replacement of unserviceable items as battery, swithces, display, microprocessor control card/ ICs/LED indicators etc. and other connected parts and refixing the same in original position complete and testing complete all as specified & as directed.
2
-
-
... More
S&F in replacement of smoke detector as per existing make and model and testing complete all as specified & as directed.
50
-
-
... More
S&F in replacement of heat detector as per existing make and model and testing complete all as specified & as directed.
5
-
-
... More
S&F in replacement of optical/photoelctrical fire detector as per existing make and model and testing complete as directed by Engr-in-charge.
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%