Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 20,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677365_1Bid Award Id
ViewTender No
GE/J- /2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
NOTE for Ser 1.00 to 03 :- (i) Change of diesel filter/oil filter,top up/replacement of engine oil, coolent if required.
(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.
(iii) Tightening of all nuts& bolts of DG set and its accessories.
(iv) Check for any diesel lekage from any point and rectify if observed.
(v) Check and adjust fan belt tension, replace the fan belts if found damaged.
(vi) Check leakage of smoke from exhaust system/silencer,Repair if required.
(vii) Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order (viii) Check and tighten the AVM pads nuts and bolts,change AVM pads if found damaged.AVM to be provided by contractor.
(ix) Check exhaust pipe,flange and lagging Repair if found damaged.
-
-
-
(x) Check output of alternator ,if found OK adjust the same to specified values in case of brush type. (xi) Checking of all hoses and cleanup,change/tighten if required. (xii) Checking of all hoses and cleanup if required.Also changing air filter elements,if required. (xiii) Oiling,Greasing and checking for proper & smooth functioning. etc and refitting, testing on load complete (xiv) Spares/parts/ Engin oils/coolant /distilled water will be measured and paid separately
-
-
-
Supply only the following spares/items for DG set 15 KVA, (Make : Kirloskar/Cummins/Ashok Leyland):-
-
-
-
Diesel fuel filter assembly (Pre filter & Micro filter) (Set of 02 Nos)
12
-
-
Air filter assembly
12
-
-
V' belt as per existing make/model
8
-
-
Fuel pipe
12
-
-
Radiator hose pipe with clamps for top and bottom
10
-
-
Battery terminal leads copper with lugs
6
-
-
Oil filter assembly
12
-
-
Ignition switch
4
-
-
Self Starter assembly of ISI Marked
5
-
-
Supply only the following spares/items for DG set 30 KVA, (Make : Kirloskar/Cummins/Ashok Leyland) :-
-
-
-
Diesel fuel filter assembly (Pre filter & Micro filter) (Set of 02 Nos)
4
-
-
Air filter assembly
4
-
-
V' belt as per existing make/model
2
-
-
Fuel pipe
3
-
-
Radiator hose pipe with clamps for top and bottom
2
-
-
Battery terminal leads copper with lugs
2
-
-
Oil filter assembly
4
-
-
Ignition switch
1
-
-
Self Starter assembly of ISI Marked
4
-
-
Supply only the following spares/items for DG set 62.5 KVA, (Make : Kirloskar/Cummins/Ashok Leyland):-
-
-
-
Diesel fuel filter assembly (Pre filter & Micro filter) (Set of 02 Nos)
6
-
-
Air filter assembly
6
-
-
V' belt as per existing make/model
3
-
-
Fuel pipe
2
-
-
Radiator hose pipe with clamps for top and bottom
3
-
-
Battery terminal leads copper with lugs
2
-
-
Oil filter assembly
6
-
-
Ignition switch
4
-
-
Self Starter assembly of ISI Marked
2
-
-
S&F in replacement automotive battery 12V 150 AH for DG Sets (Make: Exide/Amaron/Amco)
4
-
-
S&F in replacement automotive battery 12V 120 AH for DG Sets (Make: Exide/Amaron/Amco)
3
-
-
Supply and filling radiator coolant in 5 Ltrs sealed pack. (Make: Shell/Castrol/Penzoil)
100
-
-
Supply and filling distilled water for battery/radiator
60
-
-
Supply and filling engine oil 20 W 40 in 20 ltrs sealed Drums.
(Make:Shell/Castrol/Penzoil).
Note- Old Engine oil will be taken on charge by the Engr-in -charge
210
-
-
Material & Labour for taking out Radiator of DG set 15 KVA to 30 KVA for repair, welding, brazing, leak testing & refixing to DG set to its original position after cleaning of radiator with soda & acid including replacement of clamps, fins, vibration pad with alignment of the base, nuts, bolts, packing materials and testing complete all as specified and directed by Engineer in charge.
5
-
-
Material & Labour for taking out Radiator of DG set 62.5 KVA for repair, welding, brazing, leak testing & refixing to DG set to its original position after cleaning of radiator with soda & acid including replacement of clamps, fins, vibration pad with alignment of the base, nuts, bolts, packing materials and testing complete all as specified and directed by Engineer in charge.
2
-
-
Taking down & opening of cylinder head of 15 to 30 KVA DG Set and replacement of new piston ring, inlet valves, exhaust valves, oil seal, cylinder gasket and refixing the same in its original position complete all as specified and directed by Engineer in charge.
4
-
-
S&F in replacement aluminium cable lugs for cable size 35 Sqmm complete all as specified and directed by Engineer in charge.
3
-
-
S&F in replacement aluminium cable lugs for cable size 50 Sqmm complete all as specified and directed by Engineer in charge.
3
-
-
S&F in replacement aluminium cable lugs for cable size 70 Sqmm complete all as specified and directed by Engineer in charge.
3
-
-
S&F in replacement aluminium cable lugs for cable size 120 Sqmm complete all as specified and directed by Engineer in charge.
3
-
-
S&F in replacement MCCB 4 pole, 415 V, adjustable thermal & fixed magnetic setting type 63 to 100 Amp with breaking capacity 25KA complete all as specified and directed by Engineer in charge. (Make: Havells/ L&T/Legrand/Siemens/ABB)
4
-
-
S&F in replacement MCCB 4 pole, 415 V, adjustable thermal & fixed magnetic setting type 160 Amp with breaking capacity 25KA complete all as specified and directed by Engineer in charge. (Make: Havells/ L&T/Legrand/Siemens/ABB)
3
-
-
S&F in replacement MCCB 4 pole, 415 V, adjustable thermal & fixed magnetic setting type 200 Amp with breaking capacity 25KA complete all as specified and directed by Engineer in charge. (Make: Havells/ L&T/Legrand/Siemens/ABB)
2
-
-
S&F in replacement On Load changeover switch in sheet metal enclosure with front operating handle, 4 pole, 415V, current rating 63 Amps complete all as specified and directed by Engineer in charge.
(Make: Indoasian Cat No. ITAE0063 or equivalent L&T/Legrand/)
2
-
-
S&F in replacement On Load changeover switch in sheet metal enclosure with front operating handle, 4 pole, 415V, current rating 100 Amps complete all as specified and directed by Engineer in charge.
(Make: Indoasian Cat No. ITAE00100 or equivalent L&T/Legrand/)
2
-
-
M & L for control panel comprising of composite meter for digital display of voltage, current, Power factor, kW frequency,energy meter and set of push start /stop, acknowledge /reset mains breaker close/trip alternator breaker close /trip and indications of (load on mains, load on set, set fails to start, low oil pressure, high temprature alarm, high temprature trip, alternator over load) self start assembly for 15 to 62.5 KVA DG.
2
-
-
M&L Relay card 12 V DC for 15 to 62.5 KVA DG complete all as directed.
2
-
-
M&L for repairing of AMF panel/LT panels incl welding of doors, fixing of hinges, brazing & painting with one coat of primer and two coat of synthetic enamel paint complete all as specified and directed by engineer in charge.
6
-
-
M&L for Earthing in repair complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8 m below normal ground level connected to and including galvanised iron or steel earth strip 32X6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed by engineer in charge. Note - On testing after completion if the desired earth resistance is not obtained, the earthing will be redone at no extra cost.
2
-
-
Supply and Laying Cable in repair incl taking down XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls of following sizes :-
-
-
-
25 Sqmm, 4 core cable
48
-
-
50 Sqmm, 3½ core cable
48
-
-
70 Sqmm, 3½ core cable
50
-
-
Excavation in trenches n.exc 1.5metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil,complete all as specified and directed by engineer in charge
18.9
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm in depth,complete all as specified and directed by engineer in charge
10.13
-
-
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point, complete all as specified and directed by engineer in charge
8.77
-
-
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) laid flat abutting each other with width of protection being equal to length of brick. The gap between adajcent bricks shall not exceed 10 mm, complete all as specified and directed by engineer in charge.
0.61
-
-
M & L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by engineer in charge
5.67
-
-
Supply & fixing or laying galvanised steel tubing light grade 50 mm dia (ISI marked) for protection of under ground cable on poles / walls under road crossing etc complete all as specified and directed by engineer in charge
24
-
-