Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 10,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_623095_2Bid Award Id
ViewTender No
8564/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for rewinding the armature housing of pump motor dismantled with super enameled copper winding wire of appropriate gauge of thermal class “E” insulation complete all as specified and directed by Eng-In-Chrage
65
-
-
Supply only CI Impeller suitable for 60 HP Centrifugal pump set.complete all as specified and directed by Engineer-in-charge.
1
-
-
Supply only CI Impeller suitable for 20 HP Centrifugal/Monoblock pump set. complete all as specified and directed by Engineer-in-charge.
3
-
-
Supply only CI Impeller suitable for 10 HP Monoblock pump set complete all as specified and directed by Engineer-in-charge.
2
-
-
Supply only ball bearing suitable for 60 HP Centrifugal pump set complete all as specified and directed by Engineer-in-charge.
1
-
-
Supply only ball bearing suitable for 20 HP Centrifugal/monoblock pump set complete all as specified and directed by Engineer-in-charge.
3
-
-
Supply only ball bearing suitable for 10 HP Monoblock pump set complete all as specified and directed by Engineer-in-charge.
2
-
-
Supply only gland bush suitable for Centrifugal pump set of capacity 60 HP complete all as specified and directed by Engineer-in-charge.
1
-
-
Supply only gland bush suitable for Centrifugal/Monoblock pump set of capacity 20 HP complete all as specified and directed by Engineer-in-charge.
3
-
-
Supply only gland bush suitable for Monoblock pump set of capacity 10 HP complete all as specified and directed by Engineer-in-charge.
2
-
-
Supply only MS coupling with rubber seal suitable for 60 HP Centrifugal pump set with electic motor.complete all as specified and directed by Engineer-in-charge.
2
-
-
Supply only MS coupling with rubber seal suitable for 20 HP Centrifugal pump set with electric motor.complete all as specified and directed by Engineer-in-charge.
2
-
-
Disconnecting and taking out pump with motor of capacity 03 HP. of any make and model from the foundation & dismantling for overhauling and repair by replacing rewinding ,the pump bearing, bush, gland bush, coupling and impeller,pumpshaft etc re-assembling after replacement of unserviceable parts, connecting with the suction/discharge line with correct alignment and making the electric connection including testing complete and all as directed by Engineer-in-Chrage.
Note:The cost of rewinding, Pump bearing, bush, gland bush, coupling and impeller are included in this item.No seprate payement shall be made for supplying these items.
2
-
-
M & L for renewal of earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground level, connected to Galvanised earth lead wire of 4mm dia by means of bolts nuts check nuts and washers of galvanized iron or steel all as shown in the electrical plate No. 3 of MES SSR part –I connected to all earth test point all as specified and testing on completion including provision of earth lead protected by 15 mm bore light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation, earth work in any type of starta, PCC pit with RCC pit with M 25 (Design mix) cover,char coal,salt,funnel etccomplete. Note:-Rate quoted by the tenderers shall be deemed to include for following provisions:-(i) Excavation & eart work in any type of starta including removing of surplus material upto 100M (ii)PCC (1:3:6) type C1 using 20mm graded stone aggergate in pit& 40 mm thick precast RCC,M-25 design mix concrete cover 50x50 cm with 8mm round bar@15 cm C/C both ways.(iii) Main earth wire 4mm dia from earth eletrode to test point upto 7.5 mtr.(iv)Funnel with watering pipe(GI pipe) 20mm bore(ISI marked)medium grade & copper lugs and charcoal & salt as reqd.(v) GI protection pipe of size 15 mm bore light grade upto 7.5m. .
8
-
-
M&L for preparation of old painted steel surface of centrifugal pump set of 60 HP capacity by scraping ,rubbing and removing of dirt/dust oil spot and making surface smooth ready for painting and applying one coat synthetic enameled paint complete all as specified and directed by Engineer-in-charge.
2
-
-
M&L for preparation of old painted steel surface of monoblock/Centrifugal pump set of capacity upto 20 HP by scraping ,rubbing and removing of dirt/dust oil spot and making surface smooth ready for painting and applying one coat synthetic enameled paint complete all as specified and directed by Engineer-in-charge.
7
-
-
S&F in replacement Star Delta starter complete unit suitable for 10 HP motor including single phase preventer and connected accessaries complete all as specified and directed by Engineer-in-charge.
1
-
-
S&F in replacement Star Delta starter complete unit suitable for 20 HP motor including single phase preventer and connected accessaries as directed by the Engineer-in -charge.
2
-
-
S&F in replacement Star Delta starter complete unit suitable for 60 HP motor including single phase preventer and connected accessaries complete all as specified and directed by Engineer-in-charge.
1
-
-
S&F in replacement DOL starter complete unit suitable for 3 HP motor including single phase preventer and connected accessaries complete all as specified and directed by Engineer-in-charge.
2
-
-
Material and labour for Removal / Taking up of submersible pump of any capacity by disconnecting electric cable and delivery pipes etc and lowering pump along with pipe and cable on completion of repair complete including connecting and testing etc complete all as specified and directed by Engineer-in-Charge
2
-
-
Material and labour for Repair of submerssible pump/motor 03 HP, 230/415 volts by transporting to civil work shop, opening, taking out old burnt out winding, preparing for re -winding with PVC insulated copper winding of suitable gauge including all materials as required, re-assembling, testing at work shop, transporting back to site and connecting with pipe & electric supply after the pump is lowered and testing the pump for smooth functioning etc complete all as specified and directed by Engineer-in-Charge
2
-
-
M & L for Cleaning of underground /semi underground RCC reservoir of capacity 1,00,000 gallon at main pump house by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/mud, dirt etc including removing of roots, bushes etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of Potassium permanganate including writing date of cleaning with white synthetic enamel paint and removing sludge, scale, mud etc to a distance not exceeding 50 meter and depositing complete all as specified and directed by the Engineer-in-Charge
1
-
-
All as per item No. 48 above but overhead reservoir of capacity 40,000 gallon at 18 meter staging at main pump house complete all as specified and directed by the Engineer-in -Charge.
1
-
-
All as per item No. 48 above but capacity 25,000 gallon at main pump house and fire fighting pump house complete all asspecified and directed by the Engineer-in -Charge
8
-
-
All as per item no. 48 above but capacity 20000 gallon at Training institute complete all as specified and directed by the Engineer-in -Charge.
1
-
-
All as per item no. 48 above but capacity 5,000 gallon at Transit facility complete all as specified and directed by the Engineer-in -Charge.
1
-
-
Taking up or down old unserviceable sluice valves and Supply & Fixing 80 mm bore sluice valve long body, PN 1.6 with brass spindle both end flanged ISI marked complete with CI wheel nut bolt washer and rubber packing conforming to IS 14846-2000, complete all as specified and directed by Engineer-in-charge.
4
-
-
Taking up or down oldd unserviceable sluice valves and Supply & Fixing 150 mm bore sluice valve long body, PN 1.6 with brass spindle both end flanged ISI marked complete with CI wheel nut bolt washer and rubber packing conforming to IS 14846-2000, complete all as specified and directed by Engineer-in-charge.
3
-
-
Taking up or down old unservicable oblique type gun metal landing valve and Supply and Fixing oblique type gun metal landing valve single headed of size 63mm, inlet 3' NB flanded, outlet- female instantaneous with grey cast iron handle wheel with fixing arrangement viz- GI flange 100 mm/GI flange 80mm, GI bend 80/100 mm, GI nipple 100 mm/GI nipple 80 mm complete all as specified and directed by Engineer-in-charge.
4
-
-
Supply and Fixing in replacement Aqua Dura Reinforced rubber lined hose with Elastomeric coating conforming to IS : 636/19088 Type-A with gun metal end connection on both ends of 30 mtr length including taking down old unsv hose complete all as directed by the Engineer-in -Charge
8
-
-
Supply and Fixing Gun metal short branch pipe 63 mm instantaneous inlet, made threaded outlet, 15mm bore nozzle long including taking down old unserviceable gun metal short brnach complete all as specified and directed by Engr in Charge.
1
-
-
Supply & Fixing Aviation obstruction light, LED Base cat part NO. AOL/DE-48, 2 x 24 watt LED double emitter type on over head tank of 18 mtr staging complete all as specified and directed by engineer-in-charge Make : Kalin or equivalent
1
-
-
Supply , installation and testing complete of Digital water level indicator with sensors ,Aux supply 230 Volts ,Type DDS-2 ,capacity 7 meters operating on single phase supply direct display in 19 mm size digit system in meter of water Overhead tank 18 mtr staging ensuring alarm while water fall or rise over predetrmined limit with the following description. make:- Seco type DDS-2 . (a) The entire unit must operate through compact electronic circuit, which must ensure reliable opration at 230 V +/ - 10% at 50 Hz + / - 5% with reliable in digit display and alarm at low and high level of semi UG sump. (b) One circuit must be housed in high impact polystrene molded box with nylon molded connection strips. The level system must resistance transducer, while unaffected by corrosion and other contamination available in water. The product must be controlled by micro switch. (c) The whole unit must be electronically controlled and the upper level and lower level indication must be highly sensitive micro switch. The complete unit must be in two parts. Each complete part must be fitted in MS CRC sheet box seperately complete all as specified and directed by engineer-in-charge
1
-
-
M&L Painting with one coat of synthetic enamelled ordinary tint,fire hydrant box sizes 800x600x250mm double door complete all as specified and directed by Engineer-in-charge.
15
-
-
Material and labour for gland packing of sluice valves 80/100/150 mm bore with proper size asbestos graphite gland packing rope etc complete all as specified and directed by Engineer-in-Charge
24
-
-
Supply & applying of grease best quality for 3 to 60 HP pump/motor etc complete all as specified and directed by Engineer-in-Charge
4
-
-
Supply and Fixing for digital type voltmeter 0-500 volts range, flush type, AC, 50Hz in existing panel boards after disconnecting of cables and testing including removing of unserviceable voltmeter complete all as specified and directed by engineer-in-charge
6
-
-
Supply and Fixing for digital type ammeter suitable for 10 HP to 60 HP pumpset panel ,flush type with appropriate CTs, AC, 50Hz in existing panel boards after disconnecting of cables and testing including removing unserviceable item complete all as specified and directed by engineer-in-charge
5
-
-
Supply and Fix LED phase indicating lamp R-Y-B colour as required at site complete with base holder suitable for AC, 240 volts and testing including removing of old unserviceable lamps complete all as specified and directed. Make : Minilec / L&T / Siemens/AE
12
-
-
M&L for disconnecting pressure pump set 0.5 HP AC 230 volts and dismantaling motor, rewinding with super enamelled copper wire, refitting, and fixed in same position/other positionincluding testing etc complete all as specified and directed by Engineer-in-charge.
5
-
-
M&L for repair and maint, testing and comissioning of unsv water meter installed for bulk water supply at defence lab by means of taking down and carried out necessary repair, maint and overhauling of all parts of meter, replacement of old unsv parts as required on site and refixing after at same location complete all as specified and directed by EIC. Note : Replacement cost of unsv parts/spare of meter included in quoted rate.
1
-
-
Supply & Fixing MCCB Thermal magnetic proctection type 415 volts, 125 Amps, 16 KA, 4 pole complete all as specified and directed by Engineer-in-charge.
4
-
-
Supply & Fixing MCCB Thermal magnetic proctection type 415 volts, 100 Amps, 16 KA, 4 pole complete all as specified and directed by Engineer-in-charge.
2
-
-
Supply & Fixing MCCB Thermal magnetic proctection type 415 volts, 63 Amps, 16 KA, 4 pole complete all as specified and directed by Engineer-in-charge.
2
-
-
Supply and fix Contactor, 3 phase, 415 volt, suitable for 60 HP motor star delta starter with all necessary connection including taking down old un-serviceable contractor complete all as specified and directed by Engineer-in-charge.
2
-
-
Supply and fix Contactor, 3 phase, 415 volt, suitable for 20 HP motor star delta starter with all necessary connection including taking down old un-serviceable contractor complete all as specified and directed by Engineer-in-charge.
3
-
-
Supply and fix Contactor, 3 phase, 415 volt, suitable for upto 10 HP motor star delta starter with all necessary connection including taking down old un-serviceable contractor complete all as specified and directed by Engineer-in-charge.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements