Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 73,440Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677201_1Bid Award Id
ViewTender No
GE/J- /2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
,---ditto-- all as per item No. 1 above but four run of 4 Sqmm and one run of 4 Sqmm earth in 25mm dia PVC conduit complete all as specified and directed. NOTE - Four run of 4 sq.mm phase and neutral wire & One run of 4 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length.
150
-
-
,---ditto-- all as per item No. 1 above but four run of 6 Sqmm and one run of 6 Sqmm earth in 25mm dia PVC conduit complete all as specified and directed. NOTE - Four run of 6 sq.mm phase and neutral wire & One run of 6 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length.
80
-
-
,---ditto-- all as per item No. 1 above but four run of 10 Sqmm and one run of 10 Sqmm earth in 25mm dia PVC conduit complete all as specified and directed. NOTE - Four run of 10 sq.mm phase and neutral wire & One run of 10 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length.
140
-
-
,---ditto-- all as per item No. 1 above but four run of 16 Sqmm and one run of 16 Sqmm earth in 32mm dia PVC conduit complete all as specified and directed. NOTE - Four run of 16 sq.mm phase and neutral wire & One run of 16 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length.
100
-
-
Taking down carefully sub main wiring any size alongwith PVC casing capping / PVC conduit and making good disturbed surfaces complete all as specified and directed.
2810
-
-
S & F in repair 20 amp single pole and neutral enclosure with 2 pole and earth, metal enclosed plug top in powder coated CRCA steel sheet enclosre recess mounted with chained matel cover for socket out let with and incl one single pole MCB 20 Amps as reqd incl making good the disturbed portion complete all as specified and directed.
40
-
-
Taking down old unsv FTL 2 X 2 panel light fitting of capacity 80 watt incl connecting accesorries complete all as specified and directed.
550
-
-
S&F energy efficient recessed mounted CRCA sheet LED luminaire 36 watt voltage range 140-270V AC, suitable for 2'X2' grid ceiling with full glow, fully diffused, diffuser and lumen output min constant current of 120lumen/watt, burning time 50000Hrs, 6500K duly connected with diffuser soft glare free light complete with driver, holders & LED lamp incl connecting three core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Philips Cat No: RC380B-LED36S-6500 PSU OD or Cromption Cat No: LCTLRNE-36-FO-CDL or Bajaj Cat No: BZRSQL-36L-LED-CW as approved.
550
-
-
Taking down old unsv MCB distribution boards with incoming and outgoing controls any make any capacity after disconnecting and making good the disturbed porton as per existing complete all as specified and directed.
113
-
-
S&F MCBs Distribution board tripple pole and neutral (VTPN) 4 ways, powder coated, CRCA steel sheet, suitable for MCCB incomer upto 160amp, degree of protection IP-43, IK09 with reversible double door, 415V, recess mounted having insulated 250 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs and making good the disturbed porton as per existing complete all as specified and directed.
Note : MCCB, MCBs and MCB DB shall be of the same make.
48
-
-
,---ditto-- all as per item No. 13 above but MCB DB tripple pole and neutral (VTPN), 6 ways 415 volt complete all as specified and directed.
13
-
-
S&F MCBs Distribution board SPN, 4 ways, powder coated, CRCA steel sheet, degree of protection IP-43, IK-09 with reversible double door, 240V, recess mounted having insulated 200 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs and making good the disturbed porton as per existing complete all as specified and directed.
Note : MCCB, MCBs and MCB DB shall be of the same make.
8
-
-
,---ditto-- all as per item No. 15 above but MCB DB SPN 8 ways, 240V complete all as specified and directed.
26
-
-
,---ditto-- all as per item No. 15 above but MCB DB SPN 12 ways, 240V complete all as specified and directed.
10
-
-
,---ditto-- all as per item No. 15 above but MCB DB TPN 4 ways, 415V complete all as specified and directed.
9
-
-
Taking down old unsv MCCBs with incoming and outgoing controls any make any capacity after disconnecting complete all as specified and directed.
115
-
-
S&F MCCB four pole, 63amp, 415 volt, adjustable type, with breaking capacity 16KA (lcs = 100% lcu) thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB including reqd cable connections with copper lugs of suitable size and testing & commisioning and make good complete all as specified and directed.
50
-
-
,---ditto-- all as per item No. 20 above but MCCB 100 Amps 4 pole with breaking capacity 16KA complete all as specified and directed.
30
-
-
,---ditto-- all as per item No. 20 above but MCCB 125 Amps 4 pole 16 KA complete all as specified and directed.
25
-
-
,---ditto-- all as per item No. 20 above but MCCB 250 Amps 4 pole 16 KA complete all as specified and directed.
10
-
-
S&F MCBs of 'B' curve single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
224
-
-
,---ditto-- all as per item No. 24 above but MCB double pole 10 to 32 amps complete all as specified and directed.
50
-
-
,---ditto-- all as per item No. 24 above but MCB double pole 40 to 63 amps complete all as specified and directed.
32
-
-
,---ditto-- all as per item No. 24 above but MCB four pole 40 to 63 amps complete all as specified and directed.
21
-
-
Refixing serviceable MCBs SP/SPN of capacity 6 to 63 Amps in reuse as obtained from dismantling at new location complete all as specified and directed.
80
-
-
Supply, laying, jointing, testing & commissioning 1100 volts heavy duty LT XLPE cable (ISI marked) with PVC insulated aluminium conductor served with inner sheating of PVC tape armoured with galvanised steel strip or wire and overall PVC sheated cable of size 16 Sqmm nominal cross sectional area 4 core, laid in trenches, ducts, pipes or fixed on poles, including all necessary clamps, nut, bolt washers complete all as specfied and directed.
150
-
-
,---ditto-- all as per item No. 29 above but cable of size 25 Sqmm nominal cross sectional area 4 core complete all as specified and directed.
200
-
-
,---ditto-- all as per item No. 29 above but cable of size 35 Sqmm nominal cross sectional area 3.5 core complete all as specified and directed.
200
-
-
Dismantling and taking out UG cable any size and fixed in any position and removal from site complete all as specified and directed.
550
-
-
Excavation in trenches n.exc 1.5 mt wide and n.exc 1.5 m in depth, for foundation etc or for laying of cable n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in Soft/loose soil complete all as specified and directed.
90
-
-
M&L Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
50
-
-
Removing excavated material to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed.
34
-
-
M & L Sand cushioning to under ground cable with screened and washed sand (non cohessive), 8 cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge.
Note : Punned thickness shall be considered for payment purpose.
32
-
-
M & L bricks for protection cover to UG cable (with old size sub class B bricks) with width equal to length of brick, laid dry and flat abutting each other with gaps between adjecent bricks not exceeding 10mm complete all as specified and directed.
3.2
-
-
Taking up or down 40 to 50 mm bore galvanised steel tubing and connections complete all as specified and directed by Engineer -in-charge.
28
-
-
S & F 40 mm bore GI tubing light grade with all fitting (ISI marked), fixed to wall/ pole / laid in road crossing etc as reqd complete all as specified and directed.
18
-
-
,---ditto-- all as per item No. 39 above but 50mm bore pipe complete all as specified and directed.
10
-
-
M&L for earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6.0mm buried directly in ground, vertically to depth not less than 2.5mtr below normal ground level with top edge of the earth plate at depth not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected with GI lead wire 4.0mm dia means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe medium grade 20mm bore for watering, 40mm bore GI pipe medium grade for protection of GI wire upto test point including providing funnel and wire mesh GI frame and 10cm thick suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40mm graded stone aggregates complete including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exceeding 50 mtr, all as specified ans shown in Electrical plate No. 3 of SSR Part-1, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion complete. (Note - GI lead wire of size 4.0mm upto 7.5 m included in the item).
28
-
-
Supply, install, testing and commissioning of hi-wall split Air Condition (AC) of capacity 2.0 Ton, Inverter Model, 5 Star Rating, adhering to specified BEE & EER above 3.1, Refrigerant R 410 A Environmental Friendly Gas- indoor/outdoor complete with and incl cordless remote control unit and with in-built air ioniser and Plasma filter for better indoor air quality, low noise level for indoor and outdoor unit, Evaporator & Condenser Coils with high power rating and efficiency fixed in stone wall, service wire incl outdoor mounting stand of MS iron complete all as specified and directed.
4
-
-
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed input variation between 170 V to 250 V with ouput stabilized at 230 V with accuracy +2.5% and of capacity 5.0 KVA complete all as specified and directed.
4
-
-
S&F copper Tubing suitable for the item Nos 42 in extended lengths (beyond proviided by the manufacturer with AC) as requird from indoor to outdoor and Suitable insulation of Nitrile Rubber insulation fixing arrangement commissioning and testing complete all as specified and directed.
Note : One meter run of sunction line of size 1/2" or 3/8" and liquid line of size 1/4" alongwith nitrile rubber insulation is counted as one RM for measurement purpose
64
-
-
M&L for cutting of stone walls for making hole and placing of 4" dia PVC pipe of required length for split AC pipe lines power lines and drain pipe to pass through and making the surface good for further installation process complete all as specified and directed.
4
-
-
S&F single pole and neutral socket outlet, with 2 pole and earth metal enclosed plug top in powder coated CRCA steel sheet enclosre recess mounted with chained matel cover for socket out let with and incl one single pole B curve MCB 20 Amps complete all as specified and directed.
4
-
-
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
-
-
-