Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,15,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689913_1Tender No
84273/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/loose soil in layers all as specified & directed at site.
670
-
-
... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/disintegrated rock all as specified & directed by Engr-in-Charge.
20
-
-
... More
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. (Note :- For the purpose of payment only punned thickness will be measured).
337
-
-
... More
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified & directed by Engineer-in-charge.
1040
-
-
... More
Re-laying /fixing only retrieved old serviceable , XLPE insulated , Armoured , Electric Power UG Cable (Heavy Duty) , 1100 Volt Grade of any Cross sectional areacomplete all as specified and directed by Engr -in- Charge.
500
-
-
... More
Taking down and dismounting defective transformer 11/0.433 KV of capacity upto 63 KVA to 250 from foundation/ pole by using crane and transporting to workshop or factory (authorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete ,spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge.NOTE :- Spare parts ie, transformer oil, copper winding wire for rewinding will be measured and paid separately under supply only.
2
-
-
... More
Taking down old unsv gasket and supply and fixing new Synthetic rubberised gaskets for top cover of transformer for the following :-
-
-
-
... More
(a) 11/0.433 KV 63 KVA to 100 KVA capacity complete.
3
-
-
... More
(b) 11/0.433 KV 160 KVA to 250 KVA capacity complete.
2
-
-
... More
Taking down old unsv gasket and supply and fixing new Synthetic rubberised gaskets for HT bushing of transformer for the following :-
-
-
-
... More
(a) 11/0.433 KV 63 KVA to 100 KVA capacity complete.
8
-
-
... More
(b) 11/0.433 KV 160 KVA to 250 KVA capacity complete.
4
-
-
... More
Taking down old unsv gasket and supply and fixing new Synthetic rubberised gaskets for LT bushing of transformer for the following :-
-
-
-
... More
(a) 11/0.433 KV 63 KVA to 100 KVA capacity complete.
6
-
-
... More
(b) 11/0.433 KV 160 KVA to 250 KVA capacity complete.
3
-
-
... More
M&L for taking out unserviceable core and limb and HV/LV winding of transformer and taking out burnt copper winding wire cleaning carefully and rewinding the same with new superior quality 99.99% pure copper enamelled wire as per existing gauge including insulating material for transformer 63 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
340
-
-
... More
Taking out old transformer oil and M&L new transformer oil of dielectric strength 50 KV minimum for voltage stablizer, transformer, type factory sealed with test certificate complete all as specified & directed by Engineer-in - Charge.
2000
-
-
... More
Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV complete all as specified and directed by Engineer-in-Charge.(Note : For any capacity of Transformer)
3500
-
-
... More
Taking out old unsv HT brass and S&F new HT brass stem of transformer 63 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
6
-
-
... More
Taking out old unsv LT brass and S&F new LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 63 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
12
-
-
... More
Taking out old breather assembly and S&F new breather assembly with new silica gel of transformer 11/0.433 KV of capacity 63 KVA to 100 KVA complete all as specified & directed by Engineer-in - Charge.
6
-
-
... More
Taking out old breather assembly and S&F new breather assembly with new silica gel of transformer 11/0.433 KV of capacity 160 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
2
-
-
... More
Dismantling of 9/11 mtr long PCC/RCC/Steel tubular poles after breaking the foundation concrete including necessary excavation of earth, filling the hole with broken pieces of concrete and making good the disturbed area by filling excavated earth, obtained from the hole for new pole to be erected nearby area, to match with the surroudings complete all as specified and as directed by Engr -in Charge.
16
-
-
... More
M &L steel tubular swaged poles and complete with cast iron / M.S base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 mtrs long) including painting with two coats of aluminium paint over a coat of red oxide metal primer complete all as specified and directed by Engr-in-Charge. The pole shall conform to IS 2713:1980 and each component pipe shall be ISI marked and conform to IS 1161. complete all as specified and directed by Engr -in- charge.
2
-
-
... More
Supply and fix Prestressed concrete pole 11.0 metres long,152mmx152mm at top and 152mm x 260 mm at bottom class-9 including necessory connection to over head conductor complte all as speficied and directed by Engineer-in-Charge.
4
-
-
... More
Supply and fix Prestressed concrete pole 9.0 metres long, 102x172mm at top and 102x279mm at bottom, class 10 including necessory connection to Over Head Conductor complete all as specified and directed.
10
-
-
... More
Dismantling & taking down ACSR conductor, of any size, after taking necessary shut down, for 11 KV HT OH line, by loosening the binding wires, jumpers etc. for replacement of insulator / cross arms etc. complete all as specified and as directed
2
-
-
... More
Supply fabricate, fixing structural mild steel RS joist, channel angle iron, flate iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clapms, eye hook and back plate etc fabricated from structural steel section inclduing nuts, bolts,washers, welding (Cold and Hot) drilling holes for bolts, bend to any shape or size as indicated and directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete including taking down old materials all as specified and directed by Engineer-in-Charge.
5
-
-
... More
S&F ACSR conductor of size, as required at site, duly binded with insulators, jumpers etc.(fixed on poles) complete all as specified and as directed.
2
-
-
... More
Taking down old unsv existing pin insulator and S&F new pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified & directed by Engineer-in-charge.
35
-
-
... More
Taking down old unsv existing Disc insulator and S&F new disc type insulator, porcelain, vitreous with hardware, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for 11000 volts grade complete all as specified & directed by Engineer-in-charge.
25
-
-
... More
Supply, Jointing and testing outdoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 95 Sqmm to 120Sqmm 3 core 11 KV under ground XLPE cable complete and including taking down unsv joint complete all as directed by Engineer-in-Charge.
3
-
-
... More
Supply, Jointing and testing indoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 95 Sqmm to 120Sqmm 3 core 11 KV under ground XLPE cable complete and including taking down unsv joint complete all as directed by Engineer-in-Charge.
2
-
-
... More
S&F GI pipe light grade of dia 80 mm laying in road and along with poles for cable protection complete including taking down old unsv pipe all as directed by Engineer-in-charge.
18
-
-
... More
S&F GI pipe light grade of dia 50 mm laying in road and along with poles for cable protection complete including taking down old unsv pipe all as directed by Engr-in-Charge.
.
100
-
-
... More
Servicing the 11 KV GOD by cleaning the contact, disc/ pin insulator with CTC and applying the petroleum jelly at the contact point/ down rod links for smooth operation including replacing the rusted/ corroded bolts & nuts and defective insulator of GOD as required complete all as directed by Engineer - in - Charge.
Note :- Insulator shall be measured and paid under relevant items of this schedule.
10
-
-
... More
Supply & fixing Male/ Moving contact (set of 3 Nos).
10
-
-
... More
Supply & fixing Female/ Fixed contact (set of 3 Nos).
10
-
-
... More
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (12 insulators vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately)
2
-
-
... More
Supply, laying and testing, XLPE HT cable , insulated, screended, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with aluminium conductor, conforming to IS : 7098 (Part II), 11 KV, ISI marked, cross sectional area 95 Sqmm, 3 core laid in pipe/ducts/ trenches/ under floor/ under road complete and including taking down old unsv cable complete all as specified
50
-
-
... More
Supply, lay, test and commissioning of LTUG, XLPE insulated, heavy duty, 1100V grade of size 185 Sqmm 3½ core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete and incl taking down old unsv cable complete all as specified and as directed by Engineer-in-Charge.
Note : Earthwork excavation sand cushioning ,Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items.
30
-
-
... More
Supply, lay, test and commissioning of LTUG, XLPE insulated, heavy duty, 1100V grade of size 120 Sqmm 3½ core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete and incl taking down old unsv cable complete all as specified and as directed by Engineer-in-Charge.-Note : Earthwork excavation sand cushioning ,Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
850
-
-
... More
Supply & laying of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 95 Sqmm 3.5 Core and including taking down old unsv cable complete all as specified and directed by Engr-in-charge.
800
-
-
... More
Supply & laying of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 70 Sqmm 3.5 Core and including taking down old unsv cable complete all as specified and directed by Engr-in-charge.
500
-
-
... More
Supply & laying of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 50 Sqmm 3.5 Core complete and including taking down old unsv cable complete complete all as specified and directed by Engr-in-charge.
500
-
-
... More
Supply & laying of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 25 Sqmm 4 Core compelte and including taking down old unsv cable complete all as specified and directed by Engr-in-charge.
200
-
-
... More
Supply & laying of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 16 Sqmm 2 Core complete and including taking down old unsv cable complete all as specified and directed by Engr-in-charge.
1500
-
-
... More
Taking down old unsv existing APFC panel of any type and size and Supply, installation, commissioning and testing of outdoor type, 440volts, AC, LT, APFC panel of 50 KVAr capacity, factory fabricated, made out of 3.15mm CRCA sheet, CPRI approved, duly wiring with copper flexible wire of suitable rating for power control , Panel shall be dully powder coated including the following :-
4
-
-
... More
(A) Incoming
-
-
-
... More
(i) MCCB, 415 volts, 4 pole, 160 Amps, 25 kA adjustable type - 01 Nos
-
-
-
... More
(ii) Digital Ammeter with built - in - selector switch Aux Supply 230 Volts, AC - 01 Nos
-
-
-
... More
(iii) Digital Voltmeter with built in selector switch Aux Supply 230 Volts, AC-01 Nos
-
-
-
... More
(iv) LED indication lamp 230 Volts, AC 22.5mm dia RYB-03 Nos
-
-
-
... More
(v) MCB 2 Amp, Single Pole-03 Nos
-
-
-
... More
(vi) Microprocessor APFC relay with single CT sensing 12 stages auxilary supply 230volts, AC - 01 Nos
-
-
-
... More
(vii) Aluminium busbar 20x10mm, TPN - 01 Set
-
-
-
... More
(viii) Auto/Manual Switch - 01 Nos
-
-
-
... More
(B) Outgoing
-
-
-
... More
(i) Capacitor 10 KVAr ultra heavy duty 440V cylindrical - 02 Nos
-
-
-
... More
(ii) Capacitor 5 KVAr ultra heavy duty 440V cylindrical - 03 Nos
-
-
-
... More
(iii) Capacitor 3 KVAr ultra heavy duty 440V cylindrical - 04 Nos
-
-
-
... More
(iv) Capacitor 2 KVAr ultra heavy duty 440V cylindrical - 01 Nos
-
-
-
... More
(v) Capacitor 1 KVAr ultra heavy duty 440V cylindrical - 01 Nos
-
-
-
... More
(vi) MCB Triple pole 63 Amps, 10 kA, 'C' sries - 02 Nos
-
-
-
... More
(vii) MCB Triple pole 40 Amps, 10 kA, 'C' sries - 03 Nos
-
-
-
... More
(viii) MCB Triple pole 32 Amps, 10 kA, 'C' sries - 04 Nos
-
-
-
... More
(ix) MCB Triple pole 16 Amps, 10 kA, 'C' sries - 01 Nos
-
-
-
... More
(x) MCB Triple pole 16 Amps, 10 kA, 'C' sries - 01 Nos
-
-
-
... More
(xi) Capacitor duty contactor 3 pole 10 KVAr - 02 Nos
-
-
-
... More
(xii) Capacitor duty contactor 3 pole 5 KVAr - 03 Nos
-
-
-
... More
(xiii) Capacitor duty contactor 3 pole 3 KVAr - 04 Nos
-
-
-
... More
(xiv) Capacitor duty contactor 3 pole 2 KVAr - 01 Nos
-
-
-
... More
(xiv) Capacitor duty contactor 3 pole 1 KVAr - 01 Nos
-
-
-
... More
xv) 22.5mm dia Push Button ON/OFF-12 set
-
-
-
... More
(xiv) 22.5 mm dia LED Red - 12 Nos
-
-
-
... More
(xv) 22.5mm dia LED Green-12 Nos
-
-
-
... More
(xvi) Armoured 2 core copper cable 1.5sqmm shall be provided for sensing CT
-
-
-
... More
(xvii) Sensing CT as per site load condition shall be provided alongwith APFC Panel
-
-
-
... More
(xviii ) All power connection shall be done with 1100 volts FRLS copper flexible wire with copper termination of proper size and proper type
-
-
-
... More
Note (i) GA drawing for APFC panel shall be got approved from the Accepting Officer/Engineer-in-charge before manufacturing of APFC panels
-
-
-
... More
(ii) PCC plateform of suitable size shall be provided after demolition of existing PCC plateform, The cost of all above shall be demmed to be included in unit quoted rates.
-
-
-
... More
Repair/Replacement of Capacitor bank APFC panel of 25 to 75 KVAr ,Disconnecting and taking out U/S LV capicotor,Relays,,Power contectors, indicator lamp, CT Coil, wiring, terminals clips etc from housing and including fixing new items as required , all connection and testing to maint PF above 0.95 complete .(Capacitors and oter items are paid seperatly in respective items.)
4
-
-
... More
Supply only heavy duty Power capacitors 1 to 4 KVAr cylinderical type suitable for 440 Volt AC,3 phase ,50 Hz.:
10
-
-
... More
All as per item No. 47.00 but of capacity 5-to 10 KVAr
8
-
-
... More
Supply only power contactor 3 pole, 415V, suitable upto 10 KVAr Capacitor.
3
-
-
... More
Supply only power contactor 3 phase, 415V, suitable 15 to 20 KVAr capacitor.
4
-
-
... More
Supply only automatic power factor correction relay 8 stage 3 phase, 415V, 50 Hz,
2
-
-
... More
Supply only automatic power factor correction relay 12 stage 3 phase, 415V, 50 Hz,
2
-
-
... More
Supply only indicator lamp LED type, 220V
12
-
-
... More
Supply only Current Transformer coil having Ratio 100/5/200/5, 15 VA
10
-
-
... More
M& L for Internal wiring for APFC panel incl insulator ,sleeves etc & testing complete all as specified and directed.
5
-
-
... More
Supply only Terminals,Clip On 230V AC
10
-
-
... More
M&L for painting tranformer complete by removing existing oil paint by scrapping and applying two coats of approved colour synthetic enamel paint (1st grade quality) over a coat of primer after preparation of surfaces including writing SM / MES numbers and date of oil tested etc. all as directed by Engr-In-Charge and applying one coat of cement base paint on transformer plinth complete all as specified and as directed for the following capacity:-
-
-
-
... More
(a) Transformer of capacity 63 KVA to 250 KVA, 33 KV/11 KV.
5
-
-
... More
S&F dimmer suitable for voltage stablizer up to 100 KVAr or as per site requirement complete and including taking down old UNSV dimmer complete all as specified and directed by Engineer-in-charge.
12
-
-
... More
S & F servo motor 10 Kg / Sqcm with RC network suitable for voltage stablizer up to 100 KVA complete and including taking down old UNSV motor complete all as specified and directed by Engineer-in-charge. .
9
-
-
... More
S & F PCB suitable for voltage stablizer up to 100 KVA as per site requirement complete and including taking down old UNSV PCB complete all as specified and directed by Engineer-in-charge.
12
-
-
... More
S& F gear assembly shaft suitable for voltage stablizer up to 100 KVA as per site requirement complete and including taking down old UNSV gear assemble shaft all as specified and directed by Engineer-in-charge.
8
-
-
... More
S& F gear assembly suitable for voltage stablizer up to 100 KVA as per site requirement complete and including taking down old UNSV gear assemble complete all as specified and directed by Engineer-in-charge.
8
-
-
... More
S& F digital display card suitable for voltage stablizer up to 100 KVA as per site requirement complete and including taking down old UNSV display card all as specified and directed by Engineer-in-charge.
5
-
-
... More
Taking down and dismanting defective voltage stablizer of capacity upto 100 KVA from foundation by using crane and transporting to workshop or factory (authorised for such repair) for repair after disconnecting, dismantling the same for repair & renewal of unserviceable parts and reassembling complete and transporting back from workshop to site, installation on plate form, testing & commissioning to entire satisfaction of Engineer-in- Charge.
Note:- Spare parts ie, transformer oil, copper winding wire for rewinding will be measured and paid separately under supply only.
5
-
-
... More
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 32 x 6mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing on complete including taking down old earthing completed all as specified and directed by Engr-in-charge.
10
-
-
... More
Supply, installation, commissioning and testing of feeder pillar board kiosk type, LT(415 Volts, 50 Hz, 3 Phase 4 wire supply) Padastal mounted , of size 1200x900x600 mm ,double door center opening with lockng arrangement , factory assembled, outdoor type, weather and vermin proof (protection class IP-65) canopy on top, outer door made out of 3.15 mm thick CRCA sheet and inner 2 mm thick CRCA sheet for individual hinged type door for MCCBs , powder coated and supported on 50 mm x 50 mm x 6 mm angle iron frame and 3.15 mm thick MS rubber beading , complete to accommodate including the following and including taking down old unsv panel etc complete all as specified and as directed by Engr -in -Charge. (Loc :-Near Transformer at Ramgarh)
1
-
-
... More
(a) Bus bar chamber comprising 4 Nos Aluminium strip bus bars air insulated and PVC sheathed capacity 600 Amps with colour coding in separate sheet steel enclosure.
-
-
-
... More
(b) MCCB 415 Volts, 400 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short circuit and earth fault protection (service Breaking Capacity 35 KA (Ics=100% Icu)-1 No (Incomming)
-
-
-
... More
(c) MCCB 415 Volts, 250 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 35 KA (Ics=100% Icu)-2 No (for ATC, Hanager & ORT)
-
-
-
... More
(d) MCCB 415 Volts, 200 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 25 KA (Ics=100% Icu)-2 No (P/H Panel )
-
-
-
... More
(e) MCCB 415 Volts, 160 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 25 KA (Ics=100% Icu)-1 No outgoing)(Offrs Mess & Guest Room)
-
-
-
... More
(f) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No.
-
-
-
... More
(g) LED type/Neon type indicating lamps panel mounting type RYB-3 Nos.
-
-
-
... More
Supply, installation, commissioning and testing of feeder pillar board kiosk type, LT(415 Volts, 50 Hz, 3 Phase 4 wire supply) Padastal mounted , of size 1100x800x600 mm,double door center opening with lockng arrangement , factory assembled, outdoor type, weather and vermin proof (protection class IP-65) canopy on top, outer door made out of 3.15 mm thick CRCA sheet and inner 2 mm thick CRCA sheet for individual hinged type door for MCCBs , powder coated and supported on 50 mm x 50 mm x 6 mm angle iron frame and 3.15 mm thick MS rubber beading , complete to accommodate including the following and including taking down old UNSV panel etc complete all as specified and as directed by Engr -in -Charge. (Loc -Near OTM Bldg at Ramgarh)
1
-
-
... More
(a) Bus bar chamber comprising 4 Nos Aluminium strip bus bars air insulated and PVC sheathed capacity 300 Amps with colour coding in separate sheet steel enclosure.
-
-
-
... More
(b) MCCB 415 Volts, 200 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 16 KA (Ics=100% Icu)-1 No (incomming)
-
-
-
... More
(c) MCCB 415 Volts, 100 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 25 KA (Ics=100% Icu)-02 No (Outgoing) (for CH House)
-
-
-
... More
(d) MCCB 415 Volts, 63 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 16 KA (Ics=100% Icu)-6 No (Outgoing) (OR Line)
-
-
-
... More
(e) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring V, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No.
-
-
-
... More
(f) LED type/Neon type indicating lamps panel mounting type RYB-3 Nos.
-
-
-
... More
(g) S&F danger notice plate 1.6 mm thick MS sheet of size 20 x15 cm .-01 No
-
-
-
... More
(h) Platform for the feeder pillar board with PCC (1:2:4) 15 cm thick in foundation, PCC block work 1 cm (1:6) 10 mm thick rendering in cement mortar (1:6) on exposed surface and 100 mm thick PCC (1:3:6) type C1 using 20 mm graded stone agregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level and of adequate size leaving minimum 300 mm all around the feeder pillar board for movements.
-
-
-
... More
Supply, installation, commissioning and testing of feeder pillar board kiosk type, LT(415 Volts, 50 Hz, 3 Phase 4 wire supply) Padastal mounted , of 1100x800x600mm,double door center opening with lockng arrangement , factory assembled, outdoor type, weather and vermin proof (protection class IP-65) canopy on top, outer door made out of 3.15 mm thick CRCA sheet and inner 2 mm thick CRCA sheet for individual hinged type door for MCCBs , powder coated and supported on 50 mm x 50 mm x 6 mm angle iron frame and 3.15 mm thick MS rubber beading , complete to accommodate including the following and including taking down old UNSV panel etc complete all as specified and as directed by Engr -in -Charge. (Loc -Near Hanger at Ramgarh)
1
-
-
... More
(a) Bus bar chamber comprising 4 Nos Aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding in separate sheet steel enclosure.
-
-
-
... More
(b) MCCB 415 Volts, 250 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 36 KA (Ics=100% Icu)-1 No (incomming)
-
-
-
... More
(c) MCCB 415 Volts, 100 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 16 KA (Ics=100% Icu)-05 No (Outgoing) (for Hanger & ATC Room)
-
-
-
... More
(d) MCCB 415 Volts, 63 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 16 KA (Ics=100% Icu)-1 No (Outgoing) ( Briefing room)
-
-
-
... More
(e) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring V, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No.
-
-
-
... More
(f) LED type/Neon type indicating lamps panel mounting type RYB-3 Nos.
-
-
-
... More
(g) S&F danger notice plate 1.6 mm thick MS sheet of size 20 x15 cm .-01 No
-
-
-
... More
(h) Platform for the feeder pillar board with PCC (1:2:4) 15 cm thick in foundation, PCC block work 1 cm (1:6) 10 mm thick rendering in cement mortar (1:6) on exposed surface and 100 mm thick PCC (1:3:6) type C1 using 20 mm graded stone agregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level and of adequate size leaving minimum 300 mm all around the feeder pillar board for movements.
-
-
-
... More
Supply, installation, commissioning and testing of feeder pillar board kiosk type, LT(415 Volts, 50 Hz, 3 Phase 4 wire supply) Padastal mounted , of suitable size,double door center opening with lockng arrangement , factory assembled, outdoor type, weather and vermin proof (protection class IP-65) canopy on top, outer door made out of 3.15 mm thick CRCA sheet and inner 2 mm thick CRCA sheet for individual hinged type door for MCCBs , powder coated and supported on 50 mm x 50 mm x 6 mm angle iron frame and 3.15 mm thick MS rubber beading , complete to accommodate including the following and including taking down old UNSV panel etc complete all as specified and as directed by Engr -in -Charge. (Loc :Near Offrs Mess at Ramgarh)
1
-
-
... More
(a) Bus bar chamber comprising 4 Nos Aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding in separate sheet steel enclosure.
-
-
-
... More
(b) MCCB 415 Volts, 250 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 25 KA (Ics=100% Icu)-1 No (incomming)
-
-
-
... More
(c) MCCB 415 Volts, 100 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 16 KA (Ics=100% Icu)-01 Nos (Outgoing) ( Offrs Mess )
-
-
-
... More
(c) MCCB 415 Volts, 63 Amp rating 4 pole, Thermal Magnetic based release specially fixed for incoming supply with overload, short ircuit and earth fault protection (service Breaking Capacity 16 KA (Ics=100% Icu)-6 Nos (Outgoing) (Guest Room)
-
-
-
... More
(d) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring V, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No.
-
-
-
... More
(e) LED type/Neon type indicating lamps panel mounting type RYB-3 Nos.
-
-
-
... More
(f) S&F danger notice plate 1.6 mm thick MS sheet of size 20 x15 cm .-01 No
-
-
-
... More
(g) Platform for the feeder pillar board with PCC (1:2:4) 15 cm thick in foundation, PCC block work 1 cm (1:6) 10 mm thick rendering in cement mortar (1:6) on exposed surface and 100 mm thick PCC (1:3:6) type C1 using 20 mm graded stone agregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level and of adequate size leaving minimum 300 mm all around the feeder pillar board for movements. Note : Item No 9, 36, 45, 64, 66, 67, 68 & 69 will be executed only after obtaing ncessary recommendation for replacement from EI/AEI as defined in the guideline
-
-
-
... More
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-Charge.
80
-
-
... More
M & L for cement concrete (1:3:6) type C-2 using 40mm grade stone aggregate for foundation of stay assembly struts or pole or around the pole structure etc complete all as directed.
Note: PCC (1:3:6) work in around the pole structure min 100mm thickness after cleaning the surface area.
9
-
-
... More
M & L for cement concrete (1:2:4) type B-1 using 20mm grade stone aggregate for coping around poles including necessary form work finishing even and smoth with out using extra cement complete all as directed.
2.3
-
-
... More
M & L for cement concrete (1:4:8) type D-2 using 40mm grade stone aggregate in foundation of PCC pole/struts as specified including necessary form work finishing even and smoth with out using extra cement complete all as directed.
0.8
-
-
... More
S & F Distribution board, VTPN, 4 way, vertical type, double door, 415 volts as per IP -43 with provision for DPX 100 MCCB as incommer and SP/TP MCB as outgoing and electrically connecting up complete and including taking down old DB completed all as specified and directed by Engr -in- Charge.
2
-
-
... More
Supply and fix MCCBs,100 Amps, 25 KA, 4 pole with adjustable thermal & magnetic settings complete and including taking down old MCCB complete all as specified and directed.
2
-
-
... More
S&F MCCB four pole, 63 Amp 16 KA fixed thermal magnetic release with threshold and Adjustable Over Load setting: 0.7-1.0x in & wide range of snap fit internal and external accessories. Ics = 75% icu type of DNO-100D complete installation & testing complete and including taking down old MCCB complete all as specified & directed by Engr-in-charge.
2
-
-
... More
S&F MCCB four pole, 100 Amp 25 KA fixed thermal magnetic release with threshold and Adjustable Over Load setting: 0.7-1.0x in & wide range of snap fit internal and external accessories. Ics = 100% icu type of DNO-100D complete installation & testing complete and including taking down old MCCB complete all as specified & directed by Engr-in-charge.
4
-
-
... More
S&F MCCB four pole, 160 Amp 35 KA with micro processor release adjustable thermal magnetic release with threshold and Adjustable Over Load setting: 0.4-1.0x in & wide range of snap fit internal and external accessories. Ics = 100% icu type of DNO-100D complete installation & testing complete and including taking down old MCCB complete all as specified & directed by Engr-in-charge.
4
-
-
... More
S&F MCCB four pole, 250 Amp 35 KA with micro processor release adjustable thermal magnetic release with threshold and Adjustable Over Load setting: 0.4-1.0x in & wide range of snap fit internal and external accessories. Ics = 100% icu type of DNO-100D complete installation & testing complete and including taking down old MCCB complete all as specified & directed by Engr-in-charge.
2
-
-
... More
Supply and fixing 3 core PVC insulated and unsheathed 1100 volt grade multicore cable 1.5 sqmm with stranded copper conductor cable including PVC pipe 20mm dia with necessary fittings on pole from looping box to security light fitting complete and including taking down old UNSV wire complete all as specified and directed by Engr-in- Charge.
200
-
-
... More
Supply and Fix Weather proof Street light Junction Box of size 230 x 170X105 mm depth including MCB SP 6 Amp C Curve and connecting terminals 4-way and fixing with street light poles (steel) using necessary MS Clamps, nuts, bolts washers of suitable size etc. complete and including taking down old UNSV junction box complete all as specified and directed.
37
-
-
... More
S&F street light bracket made out of 40mm dia light grade GI pipe 1.5 Mtr long bend to shape including necessary fixing arrangement with MS Clamp of suitable size made out of 35 x 4 mm MS flat suitable shape to pole including nut bolts 03 Nos and washers complete and including taking down old UNSV bracket complete all as specified and directed.
37
-
-
... More
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver with separate surge protection device 5ka rating , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and sepatate connector block for termination of incomming cable connection and including taking down old UNSV street light completeall as specified and directed by Engr -in- Charge.
37
-
-
... More
Re-stringing and re-connection of ACSR duly binded with insulators, jumpers etc.(fixed on poles) complete all as specified and as directed.
1
-
-
... More
Cuttting / trimming of tree branches in close proximity to over head lines to maintain a clearance of 1.5 meters from the over head line to nearby trees complete and removing/ throughing the cutting branches to distance not exceeding 50 m or as directed by Engr -in- Charge. Note :- Only effected area of over head conductor shall be measured as per running meter.
110
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%