Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Eprocure
Opening Date14 Nov 2024
Closing Soon6 Dec 2024
Tender Amount₹ 33,50,000
Costs
EMD
₹ 67,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683923_1Tender No
8935-28/GE/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for 75 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floor all specified and directed.
1015
-
-
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into and including 25 mm thick sand bedding layer (Fazilka sand) through vibratory compa ction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engr-in-charge.
1035
-
-
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in kerb stones of size 300 mm x 300 mm x 100 mm with plain fair faces, including chamfers, weathering, throating etc setting in CM 1:4 complete all as specified and directed.
4.64
-
-
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning soft soil, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
75
-
-
Material and labour for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation filling & mass concrete complete all as specified and as directed by Engineer-in-charge.
12
-
-
Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge
148
-
-
M&L for broken brick hardcore 15 cm compacted thickness of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick,watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge
101
-
-
Material and labour for 40 mm thick cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in floor finished even and smooth without using extra cement laying in alternate bays complete all as specified and as directed by the Engineer-in-Charge.
730
-
-
S & F Steel work in tubular/hollow section in trusses, rafter, purline, post etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed by Engineer-in-charge.
1210
-
-
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and conforming to Fe-290 (Gde- E-165) quality- A complete all as specified and directed
875
-
-
S & F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
600
-
-
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
58
-
-
M & L for painting steel and iron surfaces of any discription,over 10 cm width or girth, with preparation of new or previously untreated surfaces priming with one coat of read oxide & finish with two coats of synthetic enamel paint ordinary tint all as spefified and directed by Engr-in-Charge.
226
-
-
S&F for TMT wild steel round bars (Fe-500D) 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding and welding of angle iron and complete errection all as specified and directed.
62
-
-
Material and labour for concealed Point wiring for one light point controlled by one way one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switches complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ).
4
-
-
All as per ser No 18 above but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge
1
-
-
Supply and fixed modular switch 6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.
6
-
-
Supply and fixed modular socket outlet multipurpose type 6 Amp, flush type (2module) complete all as specified and as directed by Engineer-in - charge
1
-
-
Supply and fixing Batten holder polycarbonate cased body (B22 base), top line series, with back plate complete all as specified and as directed.
2
-
-
Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, 240 volts, 5/6 Amp complete all as specified and as directed.
4
-
-
Supply and fixing LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
4
-
-
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed.
Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
30
-
-
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
1
-
-
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 6 to 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
1
-
-
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
4
-
-
Supply and fixing blanking plate suitable for any type of DB complete all as specified and as directed by Engineer-in-charge.
2
-
-
Supply and fixing energy efficient LED security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
2
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI medium grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe medium grade for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position
1
-
-
Supply,fixing, testing and commissioning of 80 MM bore heavy duty class "C" MS flanged pipe 6 mm thick, ISI marked with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structual steel supports as required/directed at site including paiting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed by Engineer-in-charge.
50
-
-
Supply,fixing, testing and commissioning of 100 MM bore heavy duty class "C" MS flanged pipe 6 mm thick, ISI marked with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structual steel supports as required/directed at site including paiting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed by Engineer-in-charge.
30
-
-
Supply and fixing automatic Gun Metal Air Release Valve 50 mm dia on wet riser, with shut off Forge Brass ball valve complete all as specified and as directed by Engineer-in-charge..
5
-
-
Supply and fix fire hydrant landing valve type A (single head outlet) gunmetal of 80 mm dia hydrant valve with 63 mm dia female outlet complete and 80 mm inlet with rubber blank cap and chain as per IS 5290-1983 ,suitable for brigade hose of 63 mm with couplings confirming to IS 903 (for internal hydrant at Ground floor to 3rd floor and roof)complete all as specified and directed .
5
-
-
Supply ,fixing,testing and commissioning of 63 mm dia 15 mtr long Controlled perclating rubbberised fabric hose conforming to IS 8423 (type 'A') incl gun metal/SS male and female instantaneous coupling,bound and rivetted to hose pipe with 1.5 mm dia copper wire complete in all respects ,hose BSI marked ,conforming to IS 636 type II and male female coupling conforming to IS 903 complete all as specified and directed by Engr-in-charge..
10
-
-
Supply,fixing,testing and commissioning of Gun metal, short type, instantaneous pattern Branch pipe to suit fire hose delivery coupling of 63 mm size complete with G M/SS nozzle of 20 mm nominal size conforming to IS 8090 complete all as specified and directed by Engr-in-charge.
5
-
-
Supply,fixing,testing and commissioning of Fire Hose Cabinet to be mounted externally near the Hydrant Post fabricated from 16 SWG MS Steel of appox size 750 mm x 600 mm x 450 mm with a canopy , door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accomodate one hydrant valve, one branch nozzle and two 7.5 mtrs hose, weather proof, Finished with P.O. fire red color ( Sample to be approved prior to entire supply) complete all as specified and directed.
5
-
-
Supply,fixing,testing and commissioning of structural steel including 8 mm thick MS plate, ISMC, ISA, M14, 110 LONG Anchor Fastners, with one coat of RED LEAD primer and two coat of Black paint complete all as specified and directed.
100
-
-
Supply,fixing,testing and commissioning of (Booster Pump) for 440 V, 3 Phase, 50 Hz confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30 m head, 100 LPM discharge 1.5 HP complete all as specified and directed.
5
-
-
Supply,fixing,testing and commissioning of100 mm dia C.I. Butterfly valves with Body: IS:210 , PN-16, confirming to IS:13095 complete all as specified and directed.
5
-
-
Supply,fixing,testing and commissioning of 80 mm dia C.I. Butterfly valves with Body: IS:210 , PN-16, confirming to IS:13095 complete all as specified and directed.
5
-
-
Supply,fixing,testing and commissioning of CI non-return valves Gun Metal internals 100 mm dia, Rubber seated shall be conforming to IS:5312. PN 16 rating with matching Flanges including Nut, bolts, washer & Gaskets complete all as specified and directed.
5
-
-
Supply,fixing,testing and commissioning of Forge Brass Ball valves 25 mm diawith screwed ends lever operated , conforming to IS standard complete all as specified and directed
5
-
-
Supply, installation, testing and commissioning of Electric fire control panel metal clad cubical type suitable for 415 V AC three phase 4 wire 50Hz supply system.The panel shouled be suitable for automatic operation for the fire pump as per the specifie parameter. The panel shall be copletely compartmentalised and complete with relays, contractors, starters, Aluminium bus bar, designation lables as per requirement, Contineous earth bar, panel separators, protective screens, cable clamping supports system, panel lamps, top/bottom cable gland plate for incoming and outgoing cable enteries complete all as specified and directed .
5
-
-
S&F copper cable 10 Sqmm x 4 Core Electric power cable for connections with Pump and Panel complete all as specified and directed .
400
-
-
Supply,fixing,testing and commissioning of C.I. 2 Way Fire Brigade Connection of 150 mm dia with Gun metal coupling complete Four instantaneous with NRV and 6 inch inlet flange with matching flanges, gaskets, stud bolts etc complete in all respects.
5
-
-
Supply and fixing fire hydrant stand post with provn of single outlet conforming to IS 908 complete all as specified and directed .
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%