Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services Tender

Works
Machinery and Tools
Eprocure
Opening Date27 Sep 2024
Closing Date29 Oct 2024
Tender Amount₹ 46,97,650 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for brick cover of old size brick 'B' class with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjecent bricks bricks not exc 10 mm over UG cable for protection, complete all as specified & directed.

2.65

-

-

... More
Supply and laying of sand including spreading, levelling and ramming in layers n.exc. 25 cm thick in each layer complete all as directed

28.3

-

-

... More
Trial bore holes 150mm dia in any type of strata of bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer - in charge complete including submitting the strata details both graphically recorded as well as strata results. Note :- The rates quoted shall deemed to include to get survey done for availability/facibility of water as recommended by CGWD before execution of work.

200

-

-

... More
M&L for bore by drilling with rotary system/ODEX system of 250mm dia in hard rock /Disintigrated rock till meeting water strata all as directed.

200

-

-

... More
All as per item No 7 above but of 250mm dia in hard rock and drilling with DTH system till meeting water strata all as directed.

20

-

-

... More
Supplying and assembling jointing lowering and fixing in position of ERW MS casing pipe 200mm dia of 5.4mm thickness ( minimum ) upto required depth below ground level in all strata (including cutting welding as required, painting etc complete ISI marked including MS well cap and also as specified and directed by Engr-in -charge. Make - TATA/Swastik/Jindal/Prakash surya

170

-

-

... More
Supply, assembling, including jointing lowering and fixing in position ERW MS slotted pipe 200mm dia of 5.4mm thickness ( minimum ) having slots of 1.59 mm wide, 75 mm long assembled and lowered as per location chart approved by the GE including cutting welding as required and painting etc complete all as specified. Note for Sr Item No-9&10 :- Rate quoted by contractor shall deemed to include for S&F well cap 200 mm dia on top of pipe with locking arrengement till the bore well become functional complete.

30

-

-

... More
Supply and packing with Pea gravel of 8mm to 4.6mm size of approved quality as ordered to packed around the casing/slotted pipe in bore well complete all as specified and directed dy Engineer- in - Charge.

15

-

-

... More
Development of tube well by compressed air with compressor of minimum capacity of 150 PSI and 450 CFM all as specified. Note:- (i) Yield test for the bore well by continuously pumping to determine safe pumping yield to be carried out by contractor at site and necessary report to be submitted. (ii) Testing of water for potability, dissolved solids, physical/chemical and bactorogical testing etc from the govt lab shall be carried out by the contractor all as directed and test report shall be submitted. (iii) The rates quoted shall deemed to include the above provisions.

22

-

-

... More
S & F housing clamp 90 cm long 20 cm wide out of 6 mm thick MS plate for 200mm dia casing pipe with necessary MS Bolts, nuts & washers at ground level in PCC ( 1 : 2 : 4 ) type B1 using 20 mm graded stone aggregate in block all as specified.

1

-

-

... More
M & L for strata sample box of second class hard wood ( Hollock / Bijasal ) of size 40cm x 30cm x 20 cm complete all as directed by Engineer - in charge.

1

-

-

... More
M & L for 50 mm bore GI medium grade column pipe in 6 m length with flanged joints duly scewed and welded with pipe suspended in deep well complete with slote for lead, GI flanges, rubber gaskat clamps, bolts, nuts, etc all as required for completion of work.

30

-

-

... More
Supply, laying, jointing/connecting and testing for 80 mm bore steel tubing galvanised medium grade pipe with all fittings, laid in trenches, complete all as specified.

200

-

-

... More
S&F , non return valve cast iron body flanged ends & drilled horizontal heavy duty including jointing material etc. complete ISI marked of size 80 mm bore for submersible pump as specified as directed.

1

-

-

... More
S&F sluice valve, cast copper alloy, Class PN 1.6, of size 80 mm dia complete including connecting.all as specified and directed

1

-

-

... More
Supply installation Testing and commissining submersible pump set Electric driven 3 phase, 415 volt, 50 c/s having discharge upto 14000 Lit / hrs at 180 m head 18 stage not less than 15 HP. Make- KSB/Kirlosker/CG.

1

-

-

... More
Supply, install, testing & commissioning of LT panel outdoor type (KIOSK) factory made powder coated paint made of 3 mm thick CRCA sheet, CPRI approved, dust and vermin proof protection, with 200 Amps copper bus bars front opened with locking arrangements mounted on angle iron frame 40x40x6mm , 45cm height from ground level and pcc work around panel (approx one cum ) as direced by engineer-in-charge and comparising of the following accessories :- (a) MCCB 100 Amp 35 KA rating 4 pole 440 volts-02 No Make-ABB/Legrand/L&T (b) MCB-63 Amps, TPN 440 V, 16 KA-02 No Make-ABB/Legrand/L&T (c) Starter, star delta, fully automatic suitable for 15 HP 3 phase elect motor - 01 No Make-L&T/Havells/AE (d) Digital Amp meter with selector switch & CT 0-50 Amps - 01 No (e) Digital Volt meter with selector switch 0-500 Volts -01 Nos (f) Single phase preventor mini lec VSP-II-01 No Make-Havells/ABB/L&T/BCH/C&S (g) Phase sequance corrector 15 HP motor, 3 phase-01 No Make-Havells/ABB/L&T/BCH/C&S (h) LED Indicator lamp - 03 Nos (RYB) (j) Wiring with suitable size copper conductor cable for LT panel. (k) Power factor correction capictor bottle type, 3 KVAR 3 phase- 01 No Make- Legrand/ABB/EPCOS (l) on load change over switch 415 volt 4 pole of capacity 100 amp

1

-

-

... More
S & F 1100 Volts grade submersible cable flate 3 core with copper conductor 10 sqmm stranded fixed to column pipes with suitable clamps jointing material complete.

396

-

-

... More
Supply & laying in trenches or passing through pipe/fixed to pole/wall PVC insulated and PVC sheathed armoured heavy duty electrical cable with multistranded aluminium conductor 1100 volts grade 25 Sqmm 3.5 core all as specified and directed

220

-

-

... More
M/L for GI pipe ( Light grade) for protection of LT Cable fixed to wall/poles /road crossing including clamps complete of size 50 mm bore all as specified and directed

10

-

-

... More
Material and labour for Earthing complete with GI earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit should not less than 4 mtr deep below normal ground level ) with top edge of the plate not less than 2.95 mtr deep below normal ground connected to and included GI earth strip 32mmx 6mm by means of bolts nuts check nuts and washer returning and filling the pits with excaviated vsoil mixing with charcoal 250 kg, crystal salt 200 kg ,magnisiun sulphate of 100 kg and vegitable soil all around the plate up to 350 mm above from top edge of plate and balence portion filling with excaviated soil in layers not exc 25 mm thick 25 mm bore galvanised iron medium grade watering pipe up to top of plate 50mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil pcc 1:3:6 type c1 . for chamber of internal size 300mmx 300mmx300mm with 120mm thick wall and 700mmx700mmx150mm thick bed concreat RCC 1:2:4 ,type b1 for precast chamber cover 50mm thick reinforced with welded steel wire fabric orxPM jali (weight not less than 4.00 kg/sqmm) ,funnel,with wire mesh complete all as specied and directed. Note (i) Quoted rate shall be deemed to include for earth strip with protection pipe up to 7.5 M length

4

-

-

... More
M&L for providing cement concrete in foundation, filling and mass concrete all including required from work etc. complete type B-2 1:2:4 for sealing bactorogical treatment/surface all as specified and directed

2.5

-

-

... More
M&L for connection of GI pipe line 80 mm to CI/GI/DI water mains of size 80/100/150/200/250 mm dia with CI/GI joints & fittings and necessary connecting accessories, complete all as specified and as directed.

2

-

-

... More
S&F Analog water flow meter cast iron body flanged ends & drilled horizontal heavy duty including jointing material etc. complete ISI marked of size 80 mm bore for submersible pump as specified as directed.

1

-

-

... More
Supply, install, testing and comiisioning of DG set as specified here-in after :- (A) Engine Specification :- Diesel engine 4 stroke, water cooled, electric start developing minimum 78 BHP at 1500 RPM suitable for 60 KVA/50 KW out put of alternator at 40°C confirming to ISO 3046, BS: 649 / BS : 5514 amended upto date. The engine shall be capable of delivering the required out put at 1500 RPM, as per BIIS under NTP condition with provision of 10% overloading for one hours in every 12 hours of operation. The scope of supply includes :- (i) Flywheel with starter Ring for Generating Set. (ii) Air filter. (iii) Lube oil cooler assembly with accessor (iv) Exhaust air manifold. (v) Exhaust Silencer. (vi) Expansion bellow. (vii) Fuel filter. (viii) Lube oil filter. (ix) Exhaust gas Turbocharger with after cooler. (x) Radiator with pusher type fan, with fan guard, coolant pump. (xi) 24 V electrical staring system with starter motor and battery charging alternator. (xii) In-line mono block fuel ejection pump with Electronic Governor and fuel feed pump. (xiii) Engine mounting supports. (xiv) Engine control panel – microprocessor based controller. (xv) Safeties and indication against low lube oil pressure, High coolant Temperature etc. (xvi) K Cool super plus corrosion inhibitor coolant for cooling. (xvii) Engine Operator / Maintenance & spare parts manual. (xviii) Engine spare parts manual. (xix) Engine warranty certificate. (xx) Engine test certificate. (B) ALTERNATOR :- The diesel engine mentioned herein before shall be coupled through flexible coupling to an indigenous synchronous alternator rated at 60KVA/50 KW at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 Phase, 4 wire system confirming to IS 4722, BS 5000 & IEC : 34 as amended upto date as per following features / specifications :- (i) Type : salient poles, single bearing, brushless type, (Contd......)

1

-

-

... More
voltage monitoring relays for mains. (ii) One No line voltage selector switch for selecting voltage between two phases and in between phase and neutral. (iii) One No. Ampere selector Switch. (iv) One No. Me selector switch to select manual or auto mode. (v) One No. Load selector switch to select load on mains or D.G. (vi) Flexible copper wire of suitable capacity. (vii) 3 Nos. Current transformers of suitable ratio. (viii) One set of indication lamps for ‘load ON’, Set running’. (ix) One set of instrument MCB’s (x) Fault indication, Alarms and protections for :- (a) Low oil pressure. (b) High cylinder temperature. (c) Over load. (d) Fail to Start. (e) Low battery Voltage. E. Display Parameters. (a) Electrical Parameters : Phase Voltage, Line current, Frequency, Average Voltage, Average current, KW, KWH, KVA, KVAR, Power factor, Earth fault current. (b) Mechanical parameters : Lude oil pressure, coolant Temperature, Engine speed, Fuel status, Engine Run Hours, Battery voltage. (F) Protections : (a) Electrical Protections : Under / Over voltage, under / over frequency, phase failure, phase sequence reverse, over current, over KW. (b) Mechanical Protections : Under / Over speed, low lube oil pressure, high engine coolant temperature, low fuel level alarm, start/stop fail, charging alternator fail. (G) FUEL TANK :- One no of sheet metal steel tank fabricated with minimum 2.0 mm thick MS sheet of suitable capacity to contain diesel for 8.0 Hrs running at full load including the following :- (a) Level indicator duly calibrated for indication the quantity of diesel in the tank (b) Drain plug with 2 meter pipe for drain out. (c) Fuel strainer. (d) Pipe for fuel supply to engine. (e) Fuel pump manually operated for filling tank rotary type. (H) Acoustic Enclosure : The acoustic enclosure shall be fabricated out of the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet confirming to relevant standards suitable for out door installation in exposed to weather condition and to limit over all noise level to 75 dB (A) at a distance of 1 mtr as specified by CPCB Norms / MOEF. (Contd....)

-

-

-

... More
(J) FOUNDATION :– (a) A PCC foundation (1:2:4, M-20 grade) of weight 2.5 times of the operating weight of Gen Set with enclosure or as recommended by the OEM whichever s higher, is required to be provided by the contractor as is included in scope of work for SITC of Gen Set. The foundation height at about 300 mm or as directed should be above ground level and length and breadth should be 0.5 m more all around the DG Set. Genset should be mounted on AVM’s inside the enclosure. Testing : The contractor shall make available testing facilities as per ISO 3046/BS 5514. The Diesel engine driven generating set shall, after assembly, be tested for parameters for its performance in the presence of representative of Accepting officere and results recorded.

-

-

-

... More
M&L, jointing and testing of DI (Ductile Iron) pipe, round flanged end on both sides of 100 mm dia , K-7 complete with rubber gasket nuts, bolts and washers inside OPC coated, white painted inside and black painted on out side complete all as specified and as directed by Engineer-in-Charge.(Make : Jindal/ Electro Steel/ Tata).

152

-

-

... More
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings

150

-

-

... More
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets

25

-

-

... More
Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonry and removal complete all as specified& directed by Engr-in-Charge.

6.87

-

-

... More
Dismantling of stone slabs or tiles of any description or thickness as in floors etc laid dry or laid dry and pointed complete all as specified & directed.

17.2

-

-

... More
Demolition of cement concrete (un-renforced) in ground floor and paving. exc. 15 cm thickness (below or above ground level.) & removal of rubbish material complete all as specified& directed by Engr-in-Charge.

20.5

-

-

... More
Taking down Chowkatts or frames with shutters ( without taking off shutters from the frame exc 1.5 sqm each & n exc 4 Sqm each and removing to store.

8

-

-

... More
Taking down Chowkatts or frames with shutters ( without taking off shutters from the frame n. exc 1.5 sq. m each & removing to store.

10

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for

3

-

-

... More
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish of the premises

150

-

-

... More
Taking down cement plaster any description on brick or stone any description complete all as specified& directed by Engr-in-Charge.

550

-

-

... More
Taking up or down 15mm steel tubing and connections, complete all as specified& directed by Engr-in-Charge.

20

-

-

... More
Taking up or down 20mm steel tubing and connections, complete all as specified & directed by Engr-in-Charge.

30

-

-

... More
Dismantling/demolition water tanks of capacity n exc 500 ltr and removing from site complete all as specified & directed by Engr-in-Charge.

2

-

-

... More
Dismantling of 75/110mm bore PVC(SWR) drain pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed.

50

-

-

... More
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.

4

-

-

... More
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed.

25

-

-

... More
S&F 35mm thick IInd class hard wood factory made panelled door shutter(two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. the size of rail and stiles as per IS: 1003 (part-I), kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified& directed by Engr-in-Charge.

10

-

-

... More
S&F steel ventilator with top hung shutter including hinges steel peg stay complete including taking down.

4

-

-

... More
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165

285

-

-

... More
M&L Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook & pintel hinges; large hasps & staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way & three way straps,plate washers & similar small articles conforming to Fe290-0 Gde E-165 etc complete all as specified and directed

10

-

-

... More
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples or nails and screws complete all as specified and directed

2

-

-

... More
S&F Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane 4 mm in thickness complete all as specified& directed by Engr-in-Charge.

2

-

-

... More
M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified& directed by Engr-in-Charge.

30

-

-

... More
Preparation of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as directed by Engineer-in-charge and all as specified.

150

-

-

... More
Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed by Engineer-in-charge and all as specified.

125

-

-

... More
S&F Butt hinges 100mm long medium weight, stainless steel complete all as specified& directed by Engr-in-Charge.

12

-

-

... More
S&F 150mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed by Engr-in-Charge.

8

-

-

... More
S&F 150mm 'D' type Aluminium handles, type, anodised complete all as specified & directed by Engr-in-Charge.

8

-

-

... More
S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor complete all as specified and directed

4

-

-

... More
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified & directed by Engr-in-Charge.

4

-

-

... More
M&L Glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendring in cm 1:4 complete all as specified & directed by Engr-in-Charge.

150

-

-

... More
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate), 25mm thick, as in floor complete all as specified & directed by Engr-in-Charge.

35

-

-

... More
M&L non skid ceramic tiles 7 to 8mm thick(square/rectangular) colored tiles area of each tiles exc 0.06 sqm but n.exc. 0.11 sqm in floor set and jointed in neat cement slurry and pointed in white or coloure cement and over 15mm thick screed bed in CM 1:6 complete all as specified & directed by Engr-in-Charge.

35

-

-

... More
Material and labour for Machine cut kota stone slab flooring 20 to 25mm thick size not less than 22" x 22" laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 20mm thick cement screed bed in cement mortar 1:6 including rubbing and mirror polishing complete all as specified and as directed.

135

-

-

... More
Material and labour for kota stone slab 20 to 25mm thick in riser of steps, skirting, dado and pillars laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 10mm thick rendering in cement mortar 1:4 including cutting, moulding outer edges, rubbing and mirror polishing complete all as specified and as directed.

15

-

-

... More
M&L Rendring 10mm thick in CM 1:6 on brick work / stone or concrete surfaces fair faces of brick work & surfaces finished even and smooth without using extra cement all as specified.

200

-

-

... More
M&L for rendering 15mm thick in CM 1:4 on brick work /stone or concrete wall surfaces fair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound ( water proof compound paid seperatly) all as specified.

250

-

-

... More
Supply only Integral waterproofing compound

50

-

-

... More
M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.

100

-

-

... More
Material and labour for prepration over new surface and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as er IS 15489-2004 alkarili and fungal resistance, dirt resistance exterior paint emulsion of required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm

250

-

-

... More
M&L for providing and applying minimum 1mm thick wall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and as directed

250

-

-

... More
Material and labour for complete removal of existing treatment from stone wall /plastered wall and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as er IS 15489-2004 alkarili and fungal resistance, dirt resistance, exterior emulsion paint of required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm over 1mm thick wall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and as directed

250

-

-

... More
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified.

50

-

-

... More
Material and labour preparation of newly plastered/unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.

100

-

-

... More
M&L for preparing newly plastered surfaces and applying two coats of Oil bound distemper over a coat of alkali resistant primer on walls and inclucluding 1 mm thick wall care putty complete all as specified and directed by Engineer-in-Charge.

150

-

-

... More
M & L for complete removing of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salt, trading oil greasy spots etc on old decorated surfaces of wall and applying two coats of oil bound distemper of approved shade/tint and inclucluding 1 mm thick Birla white wall care putty. complete all as specified and as directed.

150

-

-

... More
S&F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floor complete all as specified & directed by Engr-in-Charge.

20

-

-

... More
S&F 20mm GI tubing Medium grade fix to wall/floor complete all as specified & directed by Engr-in-Charge.

30

-

-

... More
S&F in repair PVC connection pipe, 15mm dia & 600mm long with adopter and washer at both end complete all as specified & directed by Engr-in-Charge.

2

-

-

... More
S&F Rotational moulded polyethylene water storage tanks of 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified & directed by Engr-in-Charge.

2

-

-

... More
S&F ball valves brass high pressure with polythelene float and fly net complete, screwed , iron pipes 15 mm dia complete all as specified & directed by Engr-in-Charge

2

-

-

... More
S&F in repair fancy type bib taps, chromium plated alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule and fixed bore in dia 15mm complete all as specified & directed by Engr-in-Charge.

4

-

-

... More
S&F sink with draining board made out of stainless steel 1mm thick sheet for kitchen with plug, washers, waste pipe, cast iron centilever bracket, connecting union over all minimum size 915mmx460mm with bowl size 410mmx330mmx160mm complete and fixed in repairs.

2

-

-

... More
S&F in repair Stop/angle valves,fancy type, chromium plated alloy screwed down high presure, screwed both ends for iron pipe or for unions of 15 mm dia complete all as specified & directed by Engr-in-Charge. Make-Somany/Cera/Parryware

2

-

-

... More
S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed

4

-

-

... More
S&F as in repairs Brass CP kitchen mixer for mixing hot & cold water screwed down for iron pipe and fixed screwed shanks & fly nuts, screwed for iron pipes of 15mm bore.

2

-

-

... More
S&F Rolled mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails & guides) & hanging; also fastening & fixing complete GDE Fe410-0 or E-250

85

-

-

... More
S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed by Engr-in-Charge.

20

-

-

... More
S&F 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified & directed by Engr-in-Charge.

2

-

-

... More
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified & directed by Engr-in-Charge.

2

-

-

... More
S&F PVC (SWR),110mm junction single, (Single T) equal or unequal complete all as specified & directed by Engr-in-Charge.

3

-

-

... More
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including removing the old pipes and making good the disturbed surface as per existing complete all as specified & directed.

30

-

-

... More
Demolition Mud/PCC in roofs padding any thicknes, including plastering , existing tretement and cleaning (whether full thickness removed or only or part there of) etc in all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified & directed by Engr-in-Charge.

5

-

-

... More
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in roof padding, laid to a minimum consolidated thickness of 25 mm as leveling course, laid and compacted in min slope 1:30 over roof complete all as specified& directed by Engr-in-Charge.

150

-

-

... More
M&L rendering laid 15mm thick in CM 1:4 with water proofing compound over green concrete surface(WPC will be measured and paid seperately) surface finished even and smooth (without using extra lime or cement) complete all as specified& directed by Engr-in-Charge.

150

-

-

... More
M&L Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m including cleaning surfaces over bituminious primer complete all as specified& directed by Engr-in-Charge.

150

-

-

... More
M&L APP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven reinforcement/mat (center core) with thermal insulation laid by toarch application method with overlaps 100mm on length side and 100mm on the width side as per manufacture,s instructions with fabric (wt not less than 150 gms/sqm) on primed surface including two coat of refelective silver aluminium paint over APP membrane complete all as specified.

150

-

-

... More
Cutting holes in brick walls Exc half brick but not exc one brick built in cement mortar or cement lime mortar and stone walls built in lime mortar etc for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B1 as required complete all as specified and directed.

15

-

-

... More
Demolition of Roofs, floors (other than ground floors), beams staircases, landing, chajjas, & similar suspended work Cement concrete (reinforced) complete all as specified and directed.

1

-

-

... More
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like

0.5

-

-

... More
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in chajjas and the like

0.5

-

-

... More
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed

90

-

-

... More
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types and over screed bed 20 mm thick CM 1:6 cement concrete complete

20

-

-

... More
M & L for 20 mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointing with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 10mm thick rendering in CM 1:4 for recieving stone etccomplete all as specified and as directed

2

-

-

... More
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat

10

-

-

... More
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs n exc 20 cm wide & sides of RCC/PCC bands in walls, horizintal or sloping & similar work exc 10cm but n exc 20cm wide Roughed finished surface of concrete

10

-

-

... More
M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, and eves board fixed with self tapping screws complete all as specified and directed

10

-

-

... More
M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tesile strength of 550 Mpa as in roof covering to wall, fixed with self tapping screws complete all as specified and directed

140

-

-

... More
S&F for steel work in tubular section for post /truss/ purlin/rafters etc including special shaped washer etc. complete using induction butt welded tubes conforming to I.S. 1161-1998 grade St- 240 complete all as specified and directed

410

-

-

... More
M&L False ceiling with ArmGyp-FB ceiling tiles of 595 x595 (as approved by GE) fixed with and including galvanised iron powder coated inverted "T" or "L" section (concealed GI frame work) of mettalic or equivalent suspended from ceiling with provn of galvanised wire 4 mm dia and wall taping screw including butterfly clip, hold down clips for fixing the board to frame complete all as per manufacurers instructions all as directed and specified. (a) size of main tee 39 x 24.4 x 0.8 mm (b) size of wall angle 22.2 x 22.2 x 0.65 mm (c) size of grid 0.61 x 0.61 mm complete all as directed and specified.

25

-

-

... More
M&L for false ceiling with Armgyp-FB ceiling tiles of size 595 x 595mm, 9mm thick (as approved by GE) fixed with existing frame work fixing the board to frame complete all as per manufacurers instructions complete all as directed and specified.

25

-

-

... More
M&L Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) set in cement mortar 1:6 as in coping of brick masonry wall kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin) corbels, brackets, etc. including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified& directed

1

-

-

... More
S&F Steel rolling shutters, with ball bearing, as specified including top cover, anchoring rod, hasp & staple & one shop coat of primer; erected in position as indicated, complete; gear operated type with bevel gear box & crank handle incl ball bearing and saftey lever locks mild steel with 4 levers Thickness of laths 1.25 mm all as specified and dircted

14

-

-

... More
M&L 75 mm thick PCC(1:3:6) type C1 (using 20mm graded stone aggregate ) as in plinth protection finished fair and even complete all as specified& directed by Engr-in-Charge.

50

-

-

... More
M&L for hard core of broken stone or boulders of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surface complete all as specified and directed.

5

-

-

... More
M&L cement concrete 75mm thick 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor fcomplete all as specified & directed.

65

-

-

... More
M & L for Machine pressed precast conctete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade laid over sand cushing complete all specified and directed. Note :- Sand cushioning will measured and paid seperately.

35

-

-

... More
All as per item No 116 herein before but except tiles (old tiles to be re-used).

30

-

-

... More
M&L for rubber moulded concrete colour tiles with grey cement pigment of size 300 mm x 300 m x 22-25 mm thick laid over and including 20 mm thick cement mortar screed in CM 1:6 as in floors complete all as specified and directed.

30

-

-

... More
M & L for providing and fixing stailess steel (Grade 304) railing made of hollow tubes, channels , plates etc, including welding , grinding , buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the reailing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size on the top of floor or the side of waist slab with stuaible arrangements complete all as specified and directed

30

-

-

... More
Taking down carefully copper/Aluminium point wiring for light/fan/socket/light fitting/power point and taking down of teak wood batten / PVC casing caping/PVC conduit/steel conduit and making good disturbed surfaces of walls/ceilings /floors etc incl dismentling of fittings.

117

-

-

... More
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor fire resistant low smoke halogen (FRLS- H) PVC insulated and unsheathed cable 1100 Volts grade confirming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20 mm external dia) but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling including 1.5 mm FRLS PVC insulated unsheathed copper earth wire including sunken type pressed steel terminal boxes electro plated of suitable size with bakellite white/coloured top sheet cover 3.0 mm thick for one light point controlled by one way switch all as specified & directed.

47

-

-

... More
All as per item No. 121 here-in-before but for one fan point controlled by one switch and regulator

8

-

-

... More
All as per item No. 121 here-in-before but for one exhaust point controlled by one switch and regulator

3

-

-

... More
All as per serial item No. 121 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.

33

-

-

... More
All as per serial item No. 121 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.

3

-

-

... More
All as per serial item No. 121 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour.

23

-

-

... More
Supply and fixing switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts.

94

-

-

... More
Supply and fixing switch piano, flush type, single pole, one way, 15 Amp, 230 Volts.

23

-

-

... More
Supply and fixing socket outlet, 3 pin (with 2 pin outlet also), 5/6 Amp, flush type, 240 Volts.

36

-

-

... More
Supply and fixing socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 240 Volts.

23

-

-

... More
Supply and fixing ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified.

45

-

-

... More
Supply, fixing, testing and commissioning ceiling fan with copper winding, 1200 mm sweep, min 350 RPM, min air delivery 215 cubic metre /hour BEE 5 star rated, canopy, down rod, elecetric driven single phase 230 Volts, AC, 50 Hz with brushless direct current motor (BLDC) including marking of MES No with synthetic enamle paint complete all as specified and directed.

8

-

-

... More
Supply and fixing stepped type electronic fan regulator, flush type and connecting up, ISI marked, 240 Volts.

8

-

-

... More
Supply and fix LED batten (1.2m) made of CRCA sheet housing with a PC glossy diffisure duly prewired connection having nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 20 watt including driver. it should have rated system life time of 40000 burning hours at L70 and should have a temperature of 6500 K CRI 80, thd 10 and PF0.95 complete all as specified and directed make - Crompton Cat Part CIS-305-40-57-SL-DP-NWH, Philips Cat part BN308C LED20S-6500 L120 PSU WH, Havells Cat Part STOUTPLUS600BS20WLED840SPCWH

32

-

-

... More
S&F LED type street-DRACO SERIES light luminaire 35 watt 230 V 50 Hz including all necessary fitting accessories and LED complete all as directed.

2

-

-

... More
Supply and fixing lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified.

13

-

-

... More
Supply and Fixing LED Bulb energy saving 10/11 W complete all as specified and directed Make :- Havells/Crompton/Syska

13

-

-

... More
S&F Sheet metal enclousure double door type ,suitable for fixing TPN with 200 Amps rated bus bar ,vertical DB 4 way TPN 415 Volts complete

2

-

-

... More
Supply and fixing sheet metal enclosures double door type suitable for fixing MCB's, SPN with 200 Amps rated bus bar,4 way, 240 Volts.

10

-

-

... More
S & F MCB 63 Amp, three pole & neutral, 415 Volt complete all as pecified & directed.

1

-

-

... More
S & F MCB 40 Amp, three pole & neutral, 415 Volt complete all as pecified & directed.

1

-

-

... More
S & F MCB 32/40 Amp, single pole & neutral,240 Volt complete all as pecified & directed.

10

-

-

... More
S & F MCB 6-40 Amp, single pole 240 Volt complete all as pecified & directed.

30

-

-

... More
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 6.0 sqmm 3.0 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.

154

-

-

... More
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25.0 sqmm 4.0 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.

118

-

-

... More
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & directed.

4

-

-

... More
Supply and fix exhaust fan with copper winding metal body AC single phase 230 V of size 450 mm sweep with louver. Note : (i) Rate are enclusive of making hole of suitable size in existing wall of any size and type (ii) Rate are enclusive of providing iron shutters of suitable size .

1

-

-

... More
Supply and fix exhaust fan with copper winding metal body AC single phase 230 V of size 300 mm sweep with louver. Note : (i) Rate are enclusive of making hole of suitable size in existing wall of any size and type (ii) Rate are enclusive of providing iron shutters of suitable size .

2

-

-

... More
M/L for GI pipe ( Light grade ) for protection of LT cable fixed to walls/ poles/road crossing including clamps complete of 40 mm bore

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.