Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date25 Oct 2018
Closing Date22 Nov 2018
Tender Amount₹ 12,48,560 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Carry out operation of all stop cocks , pressure reducing valves etc. to ensures free movement of the working parts.

-

-

-

... More
Replace washers and glands of all taps and ball valves to ensure water tightness.

-

-

-

... More
Inspect overflow / vent pipes and remove blockages obstructions if any.

-

-

-

... More
Check and correct earth continuty of eletrical items.

-

-

-

... More
Check maintain and refit thermostates and test its functioning.

-

-

-

... More
Checking and adjustment of pressure reducing valves.

-

-

-

... More
Checking of dead weight type high pressure release valve (PRV) by removing dead weight protection cleaning the seat and ensuring that the vest hole is not blocked / chocked.

-

-

-

... More
Visual examination of fusible plug to ensure its intactness.

-

-

-

... More
Descaling of the immertion type heating element and cleaning with diluted hydrocloric acid or clear pedette solution and testing before refixing

-

-

-

... More
Replacement / repair of neon lamp/indicator lamp.

-

-

-

... More
Replacement of the rubber /pvc gaskit to ensure water tightness.

-

-

-

... More
Testing of geysers after repairs.

-

-

-

... More
Contractor rep will collect the complaint from MES sub Stn and prepare separate register and update the register duly signed by users and submitt the same daily to MES.

-

-

-

... More
M & L for repair & servicing of storage type elect, water heater (geyser) of any make of storage capacity 25/50 Ltr comprising of locating and rectification of defects by visual inspection, brushing, cleaning of geyser externally, Replacement/Repair of neon lamp/Indicating lamp, checking and correcting earth continuty of electrical items,checking the connection of thermostates, heating element and testing its functioning, testing of geysers complete all as specified and directed by Engineer-in-charge. Note:- Cost of supply only of spare parts mentioned here-in-after shall be measured and paid for separetly, all other minor spares is deemed to be included in quoted rates.

600

-

-

... More
Supply only thermostates ISI marked of 25 ltrs capacity geyser complete all as specified and as directed.Make:- RENUTROL / DENFOSS/ INDOFOSS

250

-

-

... More
M & L in repair Industrial metal clad plug 20 A 2pole + earth 230 volt AC ISI marked complete all as specified and as directed.

60

-

-

... More
Supply only safety valve / high pressure valve for 25/50 Ltr cap geysers ISI Marked complete all as specified and as directed..

50

-

-

... More
Supply only heating element of 1.5 KW rating as required at site including rubber washers ISI marked complete all as specified and as directed.Make : Das Pass/ Racold/ Bajaj

215

-

-

... More
Supply only heating element of 2 KW rating as required at site including rubber washers ISI marked complete all as specified and as directed.Make : Das Pass/ Racold/ Bajaj

30

-

-

... More
Supply only storage tank 25 ltrs capacity made out of stainless steel sheet and confirming to relrvant IS of existing size and fixing the same complete all as specified and as directed.

60

-

-

... More
Supply only apparatus plate for 25/50 ltrs capacity gyesers incl rubber gasket/ screw/ nut bolt of required size incl making thread if required complete all as specified and as directed.

40

-

-

... More
S & F PVC connection 15 mm size with PTMT nuts of length 450 mm all as specified and directed by Engineer - in – Charge.

80

-

-

... More
M & L in repair PVC connection pipes suitable for hot water with brass hexagonal addoptres both side, suitable for 15 mm dia pipe 45 cm long complete all as specified and as directed.

120

-

-

... More
S & F cast copper alloy chromium plated connection for hot water 15 mm size of length 450 mm with nuts all as specified and directed by Engineer - in – Charge.

10

-

-

... More
M & L in repair non return valve 15 mm/20 mm dia. of brass , ISI marked complete all as specified and as directed.

10

-

-

... More
M&L for repair to leakage of copper/ steel tank of water heater by necessary welding or by brazing complete all as specified and as directed.

5

-

-

... More
M & L for preparation of steel surface and applying of one coat of synthetic enameled paint whitewith spray gun including writing of MES Nos with black paint complete all as directed for 25 Ltrs capacity geysers complete all as specified and as directed.

20

-

-

... More
M&L for disconnecting of electric connection and dismantling complete solar water heating system of capacity 500 ltrs per day including hot & cold water pipes and hot water tank complete and refixing after repairing the system fixing back in position and testing complete all as specified and directed by Engineer-in-charge. Note : Rates quoted by the contractor shall deemed to be included for :- (a) Making good the worn out missing nuts bolts, washers, union sockets, flanges and screws etc. (b) Dismantling the solar panel descaling of hot water pipes by using appropriate chemicals, cleaning and washing all copper tube thoroughly cleaning the complete panel, making the tubes scale free and re-assembling the panel. (c) Cleaning hot and cold water tanks. (d) All other materials shall be measured and separately under respective items. (e) Contractor rep will collect the complaint from MES sub Stn and prepare separate register and update the register duly signed by users and submitt the same daily to MES.

70

-

-

... More
All as per items No 16 here in before but of capacity 400 ltrs per day complete all as specified and directed by Engineer-in-charge.

50

-

-

... More
All as per items No 16 here in before but of capacity 200 ltrs per day complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
Supply and fixing in repair solar energy master collector panel made of aluminium body with toughened glass compete with copper fins of capacity 100 ltrs per day complete all as specified and directed by Engineer-in-charge. Make:- TATA BP SOLAR/ BHEL/ SOLCHROME / STAR TECH/ NOVEL ENERGY NEW DELHI

6

-

-

... More
Supplying and fixing, as in replacement, solar panel toughened glass having thickness 5 mm all as per the existing model of system complete all as specified and directed by Engineer-in-charge.

26

-

-

... More
Supplying and fixing, as in replacement, solar panel gasket made out of fine rubber to make system air tight, dust and water proof complete all as specified and directed by Engineer-in-charge.

250

-

-

... More
Supplying and fixing, as in replacement, copper tubes with collectors fins for solar energy collector panel complete of same dia and thickness as per existing, brazing by copper alloy brazing rod with the existing inlet/outlet hot/cold water pipes to make the panel water tight complete all as specified by Engineer-in-charge.

4

-

-

... More
Supplying and fixing compressed glass wool 48 mm thick between solar energy collector panel copper tubes frame and aluminum body panel including securing it on panel by means of necessary adhesives all as directed all as specified and directed by Engineer-in-charge.

40

-

-

... More
S&F as in replacement, aluminium sheet cover 25 gauge as per existing size to protect glass wool on solar energy collector panel, fixing with frame of solar panel by means of screws all as directed by Engineer-in-charge and as recommended by manufacturer.

60

-

-

... More
S&F in repair, solar energy collector panel manifold 1.40 mtr long, made of 20 mm dia copper tube having 1 No MS flange 74 mm dia welded at each end duly drilled for nuts & bolts complete all as specified and directed by Engineer-in-charge. Note : Rate quoted deemed to be included for welding of solar collector tubes with manifold all as directed by Engineer-in-charge and as recommended by manufacturer. Make:- TATA BP SOLAR/ BHEL/ SOLCHROME / STAR TECH/ NOVEL ENERGY NEW DELHI

20

-

-

... More
S&F hose pipe for hot/ cold water for solar system of suitable length as existing size complete with 02 Nos clamps all as directed by Engineer-in-charge.

300

-

-

... More
M&L for insulation of hot water pipe with glass wool and covering with aluminium sheet cladding 25 gauge for 20 mm bore GI pipe complete all as specified and directed by Engineer-in-charge.(ii) GI pipe if replaced shall be measured and paid seperately.

200

-

-

... More
M&L for insulation of hot water pipe with black Cover pipe sleaves made out of polyethylene or neoprene foam to reduce heat losses for 20 mm bore GI pipe complete all as specified and directed by Engineer-in-charge. Note :- Bldg Height Min 15 mtr insulation of pipe to be done on down pipes of said bldgs if required. (ii) GI pipe if replaced shall be measured and paid seperately.

80

-

-

... More
M&L Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate for foundations, fillings and mass concrete complete all as specified and directed by Engineer-in - Charge.

2

-

-

... More
S & F in repair Cross arms, bracings, supports, clamps and back plates fabricated from mild steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of red oxide, one under coat and one finishing coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge.

150

-

-

... More
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 4 Sqmm stranded copper conductor drawn in existing conduit with and including PVC FRLS insulated 4 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note: PVC cables three run single core of sizes as mentioned will be considered as one unit.

40

-

-

... More
S&F as in repairs heating element for solar water heater of wattage 3.0 KW operating on 240 V AC, all as specified and directed by Engineer - in – Charge. Make : Das Pass/ Racold/ Bajaj

5

-

-

... More
S&F as in repairs thermostat for solar water heater of wattage 3.0 KW operating on 240 V AC, all as specified and directed by Engineer - in – Charge.Make:- RENUTROL / DENFOSS/ INDOFOSS

5

-

-

... More
S & F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres all as specified and directed by Engineer - in - Charge .

10

-

-

... More
S & F in repair hot water storage tank of food grade stainless steel 1 mm thick 500 Ltr capacity with heat exchanger having outer aluminium (aluminium sheet thickness 25 Gauge) cladding with 50 mm thick glass wool including taking down old one and making all electric and water connection and replacement of water supply fittings like GI union, socket, Nipples etc complete all as specified and directed by Engineer-in-charge. make : Tata BP Solar/BHEL/Solchrome/Star Tech/Novel Energy New Delhi/Surya Shakti.

6

-

-

... More
S & F in repair hot water storage tank of food grade stainless steel 1 mm thick 400 Ltr capacity with heat exchanger having outer aluminium (aluminium sheet thickness 25 Gauge) cladding with 50 mm thick glass wool including taking down old one and making all electric and water connection and replacement of water supply fittings like GI union, socket, Nipples etc complete all as specified and directed by Engineer-in-charge. make : Tata BP Solar/BHEL/Solchrome/Star Tech/Novel Energy New Delhi/Surya Shakti.

6

-

-

... More
S & F in repair ball brass valve 20 mm bore dia high pressure with polythene float and fly nuts complete screwed with iron pipe and fixed all as specified and directed by Engineer - in - Charge .

15

-

-

... More
S & F in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 20 mm bore as in repairs complete all as specified and directed by Engineer – in – Charge.

30

-

-

... More
S & F in repair, 20 mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & ceiling or laid in floor all as specified and directed by Engineer - in – Charge . .

200

-

-

... More
S & F in repair,15 mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & ceiling or laid in floor all as specified and directed by Engineer - in – Charge .

40

-

-

... More
Cutting existing 20 mm/ 15 mm bore GI tubing for alteration or addition including union of suitable size complete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
S & F in repair bib taps 15 mm bore dia, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified and directed by Engineer – in – Charge .

12

-

-

... More
S & F in repair 15 mm bore stop valve, cast copper alloy screwed down, fancy type, chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified and directed by Engineer - in – Charge.

10

-

-

... More
S & F in repair bib taps 15 mm bore dia, fancy type, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified and directed by Engineer – in – Charge .

15

-

-

... More
S & F in repair LED light fitting 1 x 18 Watt, 230 Volts Baton integreated channel type with T-5 tube pre wired for LED tube fixed to ceiling/ wall and connecting with 2 core flexible PVC insulated multistrand copper conductor from ceiling rose to fitting complete. Cat part - HLPT51520 complete of Make Bajaj or equivalent in any of the make mentioned in list of products.

530

-

-

... More
Supply and fixing socket outlet 2 in 1,3 pin 5 Amp and 3 pin 15 Amp flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).

200

-

-

... More
S & F in repair sheet metal enclosure SPN with two pin and earth plug & socket complete including one MCB 20 Amp 240 volt SP "C" curve having over load & short circuit protection complete all as specified and directed by Engineer-in-charge.

60

-

-

... More
Supply and fixing in repair MCB single pole 240 volt 6-32 amps 9 KA,"C" curve with short circuit & over load protection complete all as specified and as directed. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.