Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Dec 2024
Closing Date8 Jan 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.

590

-

-

... More
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

665

-

-

... More
M & L for point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.

10

-

-

... More
M & L for concealed point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

10

-

-

... More
M & L for point wiring for one light controlled by two 2-way switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.

5

-

-

... More
M & L for concealed point wiring for one light controlled by two 2-way switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

5

-

-

... More
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

400

-

-

... More
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.

250

-

-

... More
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

250

-

-

... More
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.

100

-

-

... More
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

100

-

-

... More
M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.

50

-

-

... More
M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

50

-

-

... More
M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.

50

-

-

... More
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.

2755

-

-

... More
S & F switch, 6 A, single pole, two way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.

25

-

-

... More
S & F switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.

450

-

-

... More
S & F 3 pin socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.

900

-

-

... More
S & F (3 pin and 3 pin) with common earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.

400

-

-

... More
S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.

40

-

-

... More
S & F call bell suitable for single phase, AC, 240 volts complete all as specified and as directed.

50

-

-

... More
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.

380

-

-

... More
S & F ceiling roses, 6A, 240 V, terminals for the connection of live, neutral and protective earthing conductors, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.

720

-

-

... More
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.

140

-

-

... More
S & F modular switch, 1 way, 6 A, 1 module complete all as specified and as directed.

20

-

-

... More
S & F modular switch, 1 way, 16 A, 1 module complete all as specified and as directed.

10

-

-

... More
S & F (3 pin and 2 pin) combined modular socket outlets, 6A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.

20

-

-

... More
S & F (3 pin and 3 pin) with common earthing pins, combined modular socket outlets, 6A & 16A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.

10

-

-

... More
S & F modular white cover plate with frame, 2 modules complete all as specified and as directed.

10

-

-

... More
S & F modular white cover plate with frame, 3 modules complete all as specified and as directed.

10

-

-

... More
S & F modular white cover plate with frame, 4 modules complete all as specified and as directed.

5

-

-

... More
S & F modular white cover plate with frame, 6 modules complete all as specified and as directed.

5

-

-

... More
S & F modular white cover plate with frame, 8 modules complete all as specified and as directed.

5

-

-

... More
S & F Modular fan regulator, 120 W, 2 modules complete all as specified and as directed.

5

-

-

... More
S & F in repairs including testing LED batten light fitting 1 X 20 watt with aluminium housing and polycarbonate diffuser complete with integrated LED driver suitable for fixation on wall/roof with robust body, corrosion resistant, flicker control, superior finish. The power factor should be more than 0.95, total harmonic distortion (THD) should be less than 20%, lumen efficacy should not be less than 100 lumens per watt, total input voltage range 140-280V AC, colour rendering Index should not be less than 80, corelated colour temperature should 5000⁰-6500⁰ Kelvin, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.

400

-

-

... More
S & F in repairs LED tube light with built-in batten nominal power 9 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 810, lumen efficacy of minimum 90 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, protection grade IP 20, THD below or less than 33%, CW available CCT of 6000K, power factor of minimum 0.90, polycarbonate housing, life span of minimum 50000 working hours as per catalogue No. LHEXBLP7IN1W009 of Havells or equivalent of Make mentioned under Appendix "B" including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.

40

-

-

... More
Fixing only LED lights fitting, any type, any size on wall, ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.

800

-

-

... More
S & F in repairs double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.

10

-

-

... More
S & F in repairs double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 8 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.

5

-

-

... More
S & F in repairs double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.

25

-

-

... More
S & F in repairs double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 4 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.

25

-

-

... More
S & F in repairs single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 2 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.

20

-

-

... More
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.

50

-

-

... More
S & F miniature circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.

220

-

-

... More
S & F miniature circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.

7

-

-

... More
S & F miniature circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 50 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.

7

-

-

... More
S & F miniature circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.

6

-

-

... More
S & F in repairs rectangular block of size 45 mm X 30 mm X 50 mm, made of structural timbers of group B, first or second choice as per IS 3629: 1986 and fixed with wall with rawl plug (4 Nos) for fixing DB complete all as specified and as directed.

12

-

-

... More
S & F in repairs rectangular block of size 30 mm X 25 mm X 50 mm, made of structural timbers of group B, first or second choice as per IS 3629: 1986 and fixed with wall with rawl plug (4 Nos) for fixing DB complete all as specified and as directed.

40

-

-

... More
Supplying, installing, testing and commissioning in repairs busbar sheet metal enclosure made out of 3.15 mm thick, size not less than 600 mm X 400 mm X 400 mm, outdoor type, double door, IP54 protection, having aluminium busbar capacity 200 Amps rated fully insulated with class F materials and nuts, bolts, washers for connection for 3 phase 4 wire system, including MCCB rated current(In): 63 A, ultimate short circuit breaking capacity (Icu): 16 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, suitable for 415 V, 50 Hz AC supply including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 40 mm X 40 mm X 6 mm including fixing of legs in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete all as specified and as directed.

5

-

-

... More
Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface to match the existing surface complete all as specified and as directed.

810

-

-

... More
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. Note - Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length.

500

-

-

... More
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. Note - Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of conduit shall be measured and paid as one unit length.

200

-

-

... More
Supply and fix sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. Note - Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length.

60

-

-

... More
Supply and fix sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 10 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 10 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. Note - Four runs of 10 sqmm cable, two runs of 10 sqmm cable and one run of conduit shall be measured and paid as one unit length.

50

-

-

... More
S & F in repairs sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed.

20

-

-

... More
S & F recess mounted luminaire (panel lighting), 36 Watt LED as per catalogue No. PLANO2X2PLR36WLED840S of Havells or equivalent of Make mentioned under Appendix "B" including tube light including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.

20

-

-

... More
Taking down main switch/MCB/MCCB/MCB DB/ MCCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.

10

-

-

... More
S & F MCCB rated current(In): 100A, ultimate short circuit breaking capacity (Icu): 25 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, fixed thermal and fixed magnetic setting, four pole, suitable for 415 V, 50 Hz AC supply complete all as specified and as directed.

5

-

-

... More
S & F MCCB rated current(In): 63A, ultimate short circuit breaking capacity (Icu): 16 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, fixed thermal and fixed magnetic setting, four pole, suitable for 415 V, 50 Hz AC supply complete all as specified and as directed.

5

-

-

... More
Disconnecting electric connection and taking down existing electric meter from wooden board and S & F new wooden board of the size in replacement and fixing the electric meter on the wooden board complete all as specified and as directed.

15

-

-

... More
S & F in repairs onload change over switch 100 Amps, 4 pole, 415 volts, AC, 50 Hz in sheet metal enclosure front operating type with all necessary fixing accessories such as nuts, bolts, clamps, etc. complete all as specified and as directed.

3

-

-

... More
S & F in repairs onload change over switch 250 Amps, 4 pole, 415 volts, AC, 50 Hz in sheet metal enclosure front operating type with all necessary fixing accessories such as nuts, bolts, clamps, etc. complete all as specified and as directed.

3

-

-

... More
S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.

200

-

-

... More
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.

10

-

-

... More
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 50 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.

10

-

-

... More
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.

10

-

-

... More
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.

10

-

-

... More
S & F in repairs battery 12 volts, 65 AH, dry type in replacement of old unserviceable battery with suitable size of new copper battery terminal and lugs and initially charging, commissioning and testing complete all as specified and as directed.

15

-

-

... More
Servicing of UPS, 10 kVA by blower, opening and checking IC including replacement of unserviceable parts e.g. mass pad, control card, power card etc. complete all as specified and as directed.

1

-

-

... More
Disconnecting, taking out old unserviceable under ground cable of rated voltage 1100 V, nominal cross sectional area of main conductor 16 sqmm, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed.

500

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.

500

-

-

... More
Disconnecting, taking out old unserviceable under ground cable of rated voltage 1100 V, nominal cross sectional area of main conductor 10 sqmm, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed.

600

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.

600

-

-

... More
S & F in repairs LED bulb, System Wattage: 10 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.

50

-

-

... More
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.

270

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.

170

-

-

... More
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point

100

-

-

... More
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed.

8000

-

-

... More
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.

81

-

-

... More
Supplying & laying including taking down in trenches, in road cutting and along pole 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

12

-

-

... More
S & F in repairs switch socket combination with PVC box with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.

100

-

-

... More
S & F in repairs switch socket combination with PVC box with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.

100

-

-

... More
S & F in repairs plug top 3 pin 15 Amp 230 volt AC complete all as specified and as directed.

80

-

-

... More
S & F in repairs plug top 3 pin 5 Amp 230 volt AC complete all as specified and as directed.

100

-

-

... More
S & F in repairs LED tube lights (mirror lights), 10 W as per Model No. WIPRO GARNET D531065 or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.

100

-

-

... More
Disconnecting, taking out old unserviceable service connection cable of rated voltage 1100 V, nominal cross sectional area of main conductor upto any size and upto 4 core, any type from trenches/ ducts/pole/wall including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit or for relaying complete all as specified and as directed.

2600

-

-

... More
Supplying and fixing PVC insulated cable for working voltages of 1100 V, PVC sheathed, unarmoured, 2 core, flat or circular nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 including cable glands, lugs etc. to suit the cable in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire complete all as specified and as directed.

400

-

-

... More
Supplying and fixing PVC insulated cable for working voltages of 1100 V, PVC sheathed, unarmoured, 2 core, flat or circular nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 including cable glands, lugs etc. to suit the cable in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire complete all as specified and as directed.

600

-

-

... More
Supplying and fixing PVC insulated cable for working voltages of 1100 V, PVC sheathed, unarmoured, 2 core, flat or circular nominal cross sectional area of main conductor 4 sqmm, stranded aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 including cable glands, lugs etc. to suit the cable in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire complete all as specified and as directed.

600

-

-

... More
Supplying and fixing PVC insulated cable for working voltages of 1100 V, PVC sheathed, unarmoured, 2 core, flat or circular nominal cross sectional area of main conductor 2.5 sqmm, solid aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 including cable glands, lugs etc. to suit the cable in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire complete all as specified and as directed.

1000

-

-

... More
Supply, fixing and testing in repairs LED Building security light fitting of 25 Watt complete with robust body, corrosion resistant, superior finish, made in a single piece by high pressure die cast aluminium alloy with corrosion resistant polyester powder coated housing including fixing on wall with 1.2 metre long galvanised iron pipe 40 mm or suitable dia medium grade bracket at 120 degree angle with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed. The luminaries shall be monolithic construction totally enclosed dust and waterproof with minimum IP66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 Hz, power factor should be more than 0.95 and Total Harmonic Distortion (THD) less than 10%, corelated colour temperature should 5700⁰-6500⁰ Kelvin. Fitting should be provided with 4 kV surge protection. Driver should have high voltage withstanding capacity upto 300 volt AC. Driver should also have normal phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficacy of LED luminaries system shall be more than 100 lumens per watt.

112

-

-

... More
S & F rechargeable table lamp, LED, 5 W, 360⁰ flexibility, warm white/ yellow, 1800 mAH battery with 2.5 hours backup complete all as specified and as directed.

10

-

-

... More
S & F in repairs including testing motion sensing LED batten light fitting 1 X 20 watt with polycarbonate housing and polycarbonate diffuser complete with integrated LED driver suitable for fixation on wall/roof with robust body, corrosion resistant, flicker control, superior finish. The power factor should be more than 0.95, total harmonic distortion (THD) should be less than 20%, lumen efficacy should not be less than 100 lumens per watt, total input voltage range 140-280V AC, colour rendering Index should not be less than 80, corelated colour temperature should 5000⁰-6500⁰ Kelvin, auto off after 3 mins, eco-mode after 2 mins. of no movements, sensors: ambient light sensor, motion sensor, light emission delay less than 1 sec including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.

20

-

-

... More
Supply, fixing and testing in repairs LED batten with battery/Invertor, LED Rating (in Watts)/System Wattage/Rated Power: 20 Watt, Rated Voltage & Frequency: 230V, 50Hz, Luminaire System Efficacy (Lumen/watt): 100, Operating Voltage Range: 140-280V, Power Factor: ≥0.95, Total Harmonic Distortion: ≤30%, Colour Rendering Index(CRI): ≥80, Colour Temperature: 5000⁰-6500⁰ Kelvin, Driver Efficiency: ≥85%, Emergency Time: 3 hour, Ingress Protection: IP-20, Type of Control Gears: Electronic, Working life for LED (as per LM-80 and LM 21 reports): ≥50000 hours, Housing Material: Aluminium Extruded, Front Cover Material: Polycarbonate, Surge Protection of 3.0 kV Internal: Yes, Open & Short Circuit Protection: Yes, Reverse Polarity Protection: Yes, Battery Type: Li-Ion, Battery Backup (in Hours): 3, Emergency Light Output (Lumen %): 50, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.

20

-

-

... More
S & F LED in repairs bulb with battery/Invertor, System Wattage: 20 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (Ma): 46, Power Factor: ≥ 0.90, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Emergency Light Output (Lumen %): 50, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Battery Type: Li-Ion, Battery Backup (in Hours): 3, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.

40

-

-

... More
S & F LED in repairs bulb with battery/Invertor, System Wattage: 12 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): 46, Power Factor: ≥ 0.90, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Emergency Light Output (Lumen %): 50, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Battery Type: Li-Ion, Battery Backup (in Hours): 3, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.

50

-

-

... More
S & F LED in repairs bulb with battery/Invertor, System Wattage: 9 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): 46, Power Factor: ≥ 0.90, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Emergency Light Output (Lumen %): 50, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Battery Type: Li-Ion, Battery Backup (in Hours): 3, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.

60

-

-

... More
S & F LED in repairs all rounder bulb, Power Consumption Wattage: 15W-8W-0.5W, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, Power Factor: ≥ 0.90, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 3000⁰-6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Battery Type: Li-Ion, Battery Backup (in Hours): 3, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.

40

-

-

... More
S & F in repairs recess mounted luminaire (panel lighting), 36 Watt LED as per catalogue No. PLANO2X2PLR36WLED840S of Havells or equivalent of Make mentioned under Appendix "B" including tube light including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.

32

-

-

... More
S & F in repairs LED landscape light, 10 W as per catalogue No. LHEVACPBPN6K010 of Havells or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.

42

-

-

... More
S & F in repairs LED bollard light, Rated Voltage (V): 240, Frequency (Hz): 50 Operating Voltage Range(V): 140 to 270, Wattage (W): 40, Power Factor ≥ 0.95, System Lumens ≥ 2400, THD ≤ 10%, CCT: 5700⁰K, CRI ≥ 70%, Life ≥ 40,000 hours, Ingress Protection: IP65, Housing: Aluminium alloy powder coated in graphite grey, Reflector: Aluminium; bright anodised with sand blast, Diffuser: Clear frosted Polycarbonate, Internal Wiring: Teflon coated multistrand copper wire, Mains: Terminal 3 way 10 amps suitable for 2.5 sq. incoming cable, 3 Core Cable: PVC coated multistrand cable as per catalogue No. LPTO-40-CDL-M of Crompton Greaves or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.

24

-

-

... More
Supply & fixing in repairs 3 Phase, 5 kW automatic street light control switch using infrared sensor based twilight/ nature switch for automatic switching of streetlights, consisting of weatherproof powder coated metal box of suitable size, 1 No of twilight/ nature switch dusk to dawn, 25 Amps 3 pole contactor- 1 No, 20 Amps MCB- 6 Nos (3 Nos input and 3 Nos output) including wiring with10 sqmm copper wiring, IP54 protection grade complete all as specified and as directed.

2

-

-

... More
S & F in repairs inverter streetlight with battery backup, LED type, 50 watt capacity with pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, lumen output of minimum 5000, lumen efficacy of minimum 100 lumens per watt, input voltage range 140 - 270 V, AC, frequency 50 Hz, power factor more than 0.95, Total Harmonic Distortion (THD) less than 10%, corelated colour temperature should 5500⁰-6500⁰ Kelvin, protection grade IP 66, CRI greater than 70, LED dispersion angle more than 120⁰, LED driver efficiency more than 90%, including lithium based battery of minimum capacity 22.1 V/ 10 AH, light backup time 4 hours, emergency light output 100% of total lumen, dusk to down operation, working temperature (-)10⁰ to (+) 55⁰c and humidity level 10% to 90 % RH including 4 kV surge protection, High/Low Mains & battery voltage protection, short-circuit protection, temperature compensated battery charging battery over charge protection, battery deep discharge protection, battery reverse polarity protection, no load/open load protection including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.

30

-

-

... More
Supply only surge protector 10 kA with IP65 ingress protection complete all as specified and as directed.

60

-

-

... More
Supply only driver suitable for 45 watt LED light fittings with IP65 ingress protection complete all as specified and as directed.

50

-

-

... More
Supply only driver suitable for 60 watt LED light fittings with IP65 ingress protection complete all as specified and as directed.

50

-

-

... More
Supply only driver suitable for 90 watt LED light fittings with IP65 ingress protection complete all as specified and as directed.

20

-

-

... More
S & F in repairs solar streetlight, LED type, 25 watt capacity with pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, lumen output of minimum 3750, lumen efficacy of minimum 150 lumens per watt, Total Harmonic Distortion (THD) less than 10%, corelated colour temperature should 5500⁰-6500⁰ Kelvin, protection grade IP 66, CRI greater than 70, in built DC-DC type driver including lithium based battery of capacity 11.1 V/ 39 AH or 12.8 V/ 34.5 AH, light backup time 24 hours, Solar PV Module 60 Wp Mono Crystalline with inbuilt Battery management system (BMS), microcontroller based charge controller cum driver, automatic dimming function with PRI motion sensor, dusk to down operation, lux output 25 (from 9 metre height), working temperature (-)10⁰ to (+) 55⁰c including battery over charge protection, battery deep discharge protection, battery reverse polarity protection, no load/open load protection, load short circuit protection, solar panel & battery connection interchange protection including GI pipe bracket of suitable dia medium grade pipe bent to shape of approximately 1.5 metre length 1.5 including 2 Nos mild steel clamp of flat iron of suitable size with nut, bolt washer including 4 metre long octagonal GI pole, top dia 70 mm and bottom dia 130 mm, thickness of sheet 3mm, base plate size 200 mm X 200 mm x 12 mm, foundation bolts 4 Nos, 16mm dia, 450mm long including necessary civil works as earthworks, footing with PCC M15 (Nominal Mix concrete) using 20 mm crushed stone coarse aggregate, reinforcement etc. complete all as specified and as directed. Note: The product shall be made in India with CE & ROHS certification.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.