Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Nov 2022
Closing Date24 Nov 2022
Tender Amount₹ 18,00,000 
Notes
Download

Costs

Summary

Repair / Maint Of Em Services In Wsa Buildings At Af Stn Nal

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item 03 above but aluminium strip of size 25 x 3.15mm .

200

-

-

... More
Taking down old Copper / Alluminium strip of any sizes as down conductor/roof conductor carefully for re-use, shifting unserviceable conductor to store under sch of credit all as directed.

620

-

-

... More
M&L for refixing Copper / Alluminium strip of any sizes as down conductor/roof conductor after soldering between earth strip and refixing the copper / aluminium strip by providing new porciline insulator or burried in ground or drawn in conduit including PVC conduit, fixing apprangements with wall/roof all as per clause SSR part I and as directed.

300

-

-

... More
M&L for PCC 1:2:4 type B 1 ( 20mm graded aggregate ) Note :- PCC blocks of size 300mmx300mmx300mm to be provided for each termination rod Total 20 Nos PCC 0.027 CUM is required for Each block

0.54

-

-

... More
Taking down old unserviceable fitting and S & F LED recessed ceiling panel Luminaries comprises of CRCA sheet metal body powder coated in white. The LEDD clusters are assembled in the body & special high translucent frosted diffuser is used for uniform glare-free light distribution suitable for 600 X 600 mm ceiling. Operating voltage range 140-270 volts ,36 watt, color temp 5700 K, color rendering index more than 80, including LED light driver and ceiling mounting accessories connecting up with three core flexible copper conductor cable of suitable size. Crompton Cat part No.LCTLRP-36-FO-CDL or equivalent with approved list of makes.

12

-

-

... More
M& L for GI pipe medium grade 40 mm dia with socket at one end in the length of 1.2 mtr for supporting of air termination rod complete all as specified and as directed by engineer-in-charge.

24

-

-

... More
M&L for Earthing complete with copper plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers up to 90 cm and with tibba sand up to top level and electrode connected to copper strip 20x3 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/equipment all as shown in electrical plate No. 5 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, PCC (1:2:4) type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick and MS frame of suitable size made of angle iron 50 x 50 x 6 mm, complete all as specified. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.

5

-

-

... More
Supply & fixing LED 1x20 watt FLAME PROOF tube light fixture luminaire including integral reflector made of diecast alluminium alloy LM6 , with electronic ballast, bipin holders, .connector block, etc., and all accessories pre-wired and including connecting up with suitable size copper conductor twin core cable complete all as specified and as directed.

30

-

-

... More
S&F in repair Flame proof LED BULK HEAD light fitting FLP-WP of 1x 18 w built in control gear box made of aluminium alloy LM6 , with all accessories, lamp holders, etc. internally prewired including taking down old fittings complete all as specified and as directed. Make: Sudir, model BH/124 or equivalent with approved list of makes.

16

-

-

... More
S & Fixing in repair Submain wiring with three single core(for phase and neutral +earth) 4 sq mm wire using multistranded copper conductor PVC (FRLS) insulated unsheathed PVC insulated wire drawn through concealed stove enamelled steel conduit ISI Marked and all accessories of dia not less than 20 mm with and including steel conduit and accessories complete all as specified and as directed. (Note: Three runs of 4 sqmm wire and one run of steel concealed conduit shall be measured as one run only

90

-

-

... More
S & F in repair Submain wiring with five single core(for three phase and neutral +earth) 6 sq mm wire using multistranded copper conductor PVC (FRLS) insulated unsheathed PVC insulated wire drawn through concealed stove enamelled steel conduit ISI Marked and all accessoriesof dia not less than 25 mm with and including steel conduit and accessories complete for 12 way DB complete all as specified and as directed. Note: Five runs of 6 sqmm wire and one run of steel concealed conduit shall be measured as one run only.

50

-

-

... More
M&L flame proof, zone I & II, Gas Group II A/ II B, weather proof point wiring for one light or fan point controlled by one switch using approved colour coding as per IS with zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area)single core 1100 volts grade in and including (ERW) stove enamelled condiuit heavy duty ISI marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required including PVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductor complete all as specified and directed

-

-

-

... More
All as per 15 but for One light point/one fan point controlled by one switch suitable for flame proof switch.

40

-

-

... More
All as per 15 but for One socket 16 Amps on Independent switch & socket for flame proof switch.

2

-

-

... More
Taking down old UNSV wiring and M&L flame proof, zone I & II, Gas Group II A/ II B, weather proof point wiring for one socket point controlled by one switch using approved colour coding as per IS with zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 4.0 Sqmm (nominal area)single core 1100 volts grade in and including (ERW) stove enamelled condiuit heavy duty ISI marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required including PVC insulated unsheated flexible copper conductor cable 4.0 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductor complete all as specified and directed

4

-

-

... More
Taking down old UNSV switch and M & L Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V

52

-

-

... More
Taking down old UNSV switch and M & L Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth

2

-

-

... More
S&F Ceiling rose, PVC/Polycarbonate, Isolated body, 3 terminals, AC, 230V, ISI Marked c.omplete all as specified and as directed by engineer-in-charge.

12

-

-

... More
S & Fixing in repairs Decorative Ultra slim linear 20W, 4 feet LED lighting fixture with extruded Aluminium heat sink, environmental friendly, energy efficient prewird with lamp, AC, 230V, ISI marked. Make : Havell's model No. LHEXBHP7PN1W020 or equivalent with approved list of makes.

6

-

-

... More
Supply and fix in repair Flame proof - weather proof CMRI approved MCB socket & plug combined 16 A, 500 V(3P+Earth) for EOT crane including taking down old socket & plug complete all as specified and as directed by engineer-in-charge.

2

-

-

... More
Supply & fix Flame proof Sheet metal enclsoure SPN 8 way for fixing MCBs 240 volt including MCB DP 32 A- 1 No as incomer & MCBs SP 6 to 16 Amps-6 Nos as outgoing with as specified .

2

-

-

... More
Supply & fix in repair Flame proof Sheet metal enclsoure for fixing MCBs 4 way 240 volt including MCB DP 32 A- 1 No as incomer & MCBs SP 6 to 32 Amps-2 Nos as outgoing with as specified .

3

-

-

... More
Taking down old UNSV light fittings any type and Supply & Fix LED street light 72 Watt operating temp range -20deg.C to +50 deg C SL light fitting 72 Watt fitting ingress protection IP 66 conforming to IS 16107 with photo biological saftey as per IS 16108 , type of LED luminarie as per IS and type B , Type of LED modules as per IS 16103 type 3 with luminarie system efficiencey 100lm/watt with adjust mounting brackets. Make Surya Cat part No SLE UL 72W IP66 LXN or equivalent in WIPRO/Crompton Greaves/Bajaj.

30

-

-

... More
Supply and fix LED 150 W flood light fitting on pole /wall with lense , high luminous rectangular LED flood light with innovative thermal management and available with multiple optics and equiped with IP 66 protection better distribution applicable for area lighting including suitable mounting brackets nuts and bolts and electrical connection complete all as directed. Make Crompton Cat part No. CFS-50I-150-60D-SL-GL-NSG or equivalent with approved list of make.

4

-

-

... More
Taking out LT cable XLPE/PVC sheathed 1100 volts grade armoured with aluminum conductor carefully of any size from trenches, poles, under floor etc for further use/disposal all as specified and directed.

1085

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.

875

-

-

... More
Excavation in trenches, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable for soft/ loose soil and getting out all as specified.

210

-

-

... More
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil all as specified.

136

-

-

... More
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level.

74

-

-

... More
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose

60

-

-

... More
M&L for cover to underground cable with one layer of bricks using sub class B bricks (old size) laid flat across the cable complete all as specified and directed.

6.4

-

-

... More
Material and labour for making cross hole suitable for 50 mm dia bore pipe including passing GI pipe of size 50 mm dia, below the road with the help of pressure pipe/ boring tools for passing the cable and removing of surplus soil to a distance not exceeding 100 mtr from work site all as directed. Note : Gi pipe to be measured and paid seperately under relevant items,.

25

-

-

... More
Supply, laying and testing in replacement of 40 mm bore GI tubing (light grade) with new fittings, laying in floor/trenches for support UG cables as directed by Engr-in-Charge.

45

-

-

... More
S&F -in-repair for kiosk box of minimum size 300x200x100 mm for luminaries control swithes, weather proof made out of PVC/HDPE fire retardant, non fusing, shock & rust proof, single piece moulded/SMC housing and SMC cover with hinged door, pole mounting type comprising of aluminium busbar TPN of 60 Amps with 6 Amps MCB, SP with base channel , fixed on pole with MS, clamps 30x5 mm with necessary nuts, washer for Street light)

46

-

-

... More
Taking down old UNSV two core cable and supply & fix twin core sheathed copper conductor FRLHS from DBs to street light include making hole to neary by on pole include flexible steel conduite on open portion and passing from one hole to other for making connection to street light, complete all as specfied and directed by Engineer in charge.

450

-

-

... More
Supply, laying and testing cable XLPE Insulated , screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specfied and directed by Engineer in charge.

210

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.