Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date3 Sep 2024
Closing Date8 Oct 2024
Tender Amount₹ 95,65,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed.

1680

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed.

666

-

-

... More
Dismantling of stone slabs and tiles of any description or any thickness in floors, dado, apron etc, laid bedded and pointed in any mortar, complete all as specified & as directed.

14.9

-

-

... More
Dismantling of cast iron, wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.

123

-

-

... More
Taking down shutters (including fittings & fixtures) of any description not exceeding 1.0 sqm each, complete all as specified and as directed.

25

-

-

... More
Taking down shutters (including fittings & fixtures) of any description exc 1.0 sqm and not exceeding 2.0 sqm each, complete all as specified and as directed.

50

-

-

... More
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.

20

-

-

... More
Taking down chowkat or frame with shutters (including fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.

20

-

-

... More
Taking down old rusted & damaged steel windows/ventilators of any description and of any type & size without guard bars / grill including cutting holes for hold fasts & making good the disturbed portion complete all as specified & as directed.

90

-

-

... More
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.

59

-

-

... More
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.

122.5

-

-

... More
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.

83.5

-

-

... More
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.

43

-

-

... More
M&L for anti-termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified & as directed.

180

-

-

... More
M&L for anti-termite treatment to Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified & as directed.

146

-

-

... More
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.

5.9

-

-

... More
M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.

2.5

-

-

... More
M&L for PCC 1:2:4 type B2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.

15.5

-

-

... More
M&L for PCC 1:3:6 type C0 (using 12.5mm graded crushed stone aggregate) as in filling up chowkat/frame hollows and similar works complete all as specified and as directed.

0.5

-

-

... More
M&L for cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and as directed.

0.5

-

-

... More
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.

6.25

-

-

... More
M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed. Note :- Reinforcement shall be measured and paid for separately under respective item of this Schedule.

0.65

-

-

... More
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate in chajjas and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.

0.75

-

-

... More
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate in Chullah hoods, stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings; RCC water tanks upto 1500 litres and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.

10

-

-

... More
Supply only integral liquid water proofing compound (ISI marked) complete all as specified & as directed.

43.7

-

-

... More
M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.

6

-

-

... More
Material and labour for brick work with old size burnt clay sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement and sand mortar 1:4 complete all as specified and as directed. Note : Brick work under this item shall be carried out in sewage disposal work (i.e. manholes) and area drainage work (i.e. drains).

5

-

-

... More
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified & as directed.

60

-

-

... More
Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) complete all as specified & as directed.

40

-

-

... More
Supply and fixing factory made 35 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified & as directed.

60

-

-

... More
Supply and fixing factory made 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24(a) of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & as directed.

35

-

-

... More
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour single piece extruded PVC profile reinforced with MS square tube, fixing in opening as per specifications complete all as specified and as directed.

96

-

-

... More
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with plain colour single piece extruded PVC profile ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour single piece extruded PVC profile for top rail lock rail bottom rail on either side and as gap insert for Top rail and bottom rail paneling of plain colour PVC sheet to fitted on the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and as directed..

25

-

-

... More
M&L for 18/19mm thick prelaminated particle board (ISI marked), interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work/hinges as in cupboard shutters, shelves, Kitchen cabinets etc with & including necessary 18/19mm wide & 6mm thick Teak wood beading / edging / lipping fixed with nails to particle board complete all as specified & as directed.

50

-

-

... More
S&F butt hinges of size 100mm heavy weight, cold rolled mild steel and fixed ISI marked complete all as specified and as directed.

90

-

-

... More
S&F butt hinges of size 100mm stainless steel, ISI marked complete all as specified and as directed.

60

-

-

... More
S&F butt hinges of size 100mm medium weight, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and as directed.

60

-

-

... More
S&F 100mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed.

40

-

-

... More
S&F 150 mm long mild steel barrel tower bolts, stove enameled black with bright bolts and fixed complete all as specified and as directed.

100

-

-

... More
S&F extruded aluminium alloy handle, 100mm size, fabricated type, anodized (ISI marked) complete all as specified and as directed.

40

-

-

... More
S&F mild steel pressed handle, 150 mm size, oval type, stove enameled black complete all as specified and as directed.

100

-

-

... More
S&F 250mm long mild steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified & as directed.

35

-

-

... More
S&F mild steel 300mm ordinary rat tail rod pattern spring including roller and roller plate, complete all as specified & as directed.

20

-

-

... More
Supply and fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.

25

-

-

... More
Supply and fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, fixed in repairs, complete all as specified and as directed.

10

-

-

... More
S&F in repairs mild steel chromium plated tubular curtain/drapery rod 25mm dia (in lengths as directed) with & including pair of projecting type fancy mild steel chromium plated brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam complete all as specified & as directed.

118

-

-

... More
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples; chains; hand made sliding bolts; clamps, hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified and as directed.

900

-

-

... More
S&F mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and as directed.

3100

-

-

... More
Erection Fixing only mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., including repairing and proper shaping in alignment of dismenteled doors complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and as directed.

12000

-

-

... More
S&F mild steel holdfast, hook and pintle hinges, large hasp and staples, clamps, hooks for hanging fans and similar small articles conforming to Grade E-165 (Fe 290) including necessary welding etc. and fixed in position complete all as specified & as directed.

40

-

-

... More
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.

562

-

-

... More
M&L for mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.

350

-

-

... More
All as per serial item No. 54.00 here-in-before but 6 to 10 mm dia in stirrups, spacers and binders complete all as specified & as directed.

80

-

-

... More
Material and labour welding in repair not exc 2.5cm in length of metal to be welded exceeding 6mm complete all as specified & as directed.

330

-

-

... More
Material and labour welding in repair not exc 2.5cm in length of metal to be welded exceeding 6mm but not exceeding 9mm complete all as specified & as directed.

250

-

-

... More
Material and labour for running welding in repairs thickness of metal to be welded not exceeding 6mm complete all as specified and as directed.

1800

-

-

... More
Providing and fixing double scaffolding system (cup lock type) of MS tube 1.5m centre to centre, horizontal & vertical tubes joining with cup & lock system for working platform etc and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The elevational area of the scaffolding shall be measured for payment purpose and taking down /out loose & damaged concrete/cement plaster from soffits of ceiling floors roofs slabs, vertical surfaces of columns, beams etc by using of low impact hammer including exposing and removing rust from the reinforcement by rubbing with wire brush and removal of debris to a distance not exceedng 100 mtr and depositing where as directed.

180

-

-

... More
Cleaning of exisiting reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, diet etc, complete and proving, applying two coats of alkline rust converting primer Sika RustOff-100 or equivalent @ 0.20 Kg/sqm on the existing rebar and allowing it to react with rust for 6 hours and form corroson resistant, insoluable and adherant protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls, with time interval of 1 hour between the coats complete all as specified and directed.

180

-

-

... More
Making 'V' groove of 5mm wide and 5mm deep over crack line by electrically operated angle grinder with diamond concrete saw blade and cleaning it by air blower and Sealing of exposed 'V' groove of 5mm deep and 5mm wide with solvent-free, moisture tolerant thixotropic, two part structrural adhesive and repair mortar, based on epoxy resins and special fillers, designed for use at temperatures between +10°C and +40°C, Sikadur-31(IN) or equivalent having conforms to ASTM C 881-78, Type I, Grade 3, Class B+C, compressive strength 60 N/mm2 (14 days) according to ASTM C 881 : bond strength 10 N/mm² (7 days) according to ASTM C 882.

40

-

-

... More
Drilling holes of 12mm dia, upto 100mm deep holes in structrual members at the interval of 250mm in staggered manner or along the crack line as directed by the consultant in reinforced concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatitable with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix it inside the hole by applying thixotropic epoxy putty Sikagard-694 F(I) or equivalent to ensure complete sealing and allow to cure the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, levelling and difinsihing the external surfacr after completion of the work etc complete. Grouting injecting two part, low viscosity, moisture insensitive injection-liquid, based on high strength epoxy resin Sikadur®-55 LP or equivalent by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having mixed density 1.08 kg/l (at +27°C) : Viscosity ~ 250 mPass at +30°C and should comply according to ASTM C 881 Type II and IV, Grade-I, class E+F and should have below properties. Compressive strength = 70 N/mm2 (7 days) according to ASTM D 695 : Tensile Strength ~ 50 N/mm2 (after 7 days at +30º C cure) According to ISO 527-2: Flexural strength ~50 N/mm2 according to EN 196-1).

500

-

-

... More
Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufactrure specification including prepartation of surface by chipping and throughly cleaning of surface complete wherever required and as per directions of Engineer-in-Charge with Sikadur®-32 LP in consumption of 0.4kg/m2. The product should comply with ASTM C 881 Type II Grade 2 Class B+C and bond strenghth should be 10 MPa.

180

-

-

... More
Rebulilding the section of damaged RCC elements to its original size in reqired thickness in layers of 50 mm & less in each by providing and applying with prebatched, three component epoxy mortar Sikadur 43 patch repair mortar Sikadur 43 HE (h) equivalent having compressive strength = 108 N/mm2 (14 days) : Tensile strength 12 N.mm2 (7 days) ,consumption 2.2 kg per sqm per mm. thickness considered per 10mm thickness complete all as specified and directed.

180

-

-

... More
Supply and apply water dispersed, acrylic copolymer based concrete curing compound for the prevention of premature water loss from concrete by Sika Antisol A4 or equivalent with consumtion of 5 to 6.5 m2 per liter complete all as specified and directed.

180

-

-

... More
Rebulilding the section of damaged RCC elements to its original size in thickness of 100mm by providiing and casting with ready to use non shrink, cementitious free flow micro-concrete SikaRep Microcrete-4 or equivalent having compressive strength 60 N/mm2 (28 days) according to ASTM C 1107-99 including providing and fixing of watertight foam faced finish shuttering of minimum 18mm thickness and supporting formwork, all lead fit, mixing, placing, de-shuttering, levelling the surface by grinding off cementitious slurry or cementitious joints differences if any for satisfaction of Engineer-in-Charge.

3

-

-

... More
S&F factory made pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, made out of mild steel sheet of 1.25 mm thickness, complete as specified & as directed.

50

-

-

... More
S&F factory made pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, made out of mild steel sheet of 1.25 mm thickness, complete as specified & as directed.

50

-

-

... More
S&F aluminium work powder coated of any colour as approved (thickness of powder coating not less than 50 micron) as in frame & shutters for doors, windows, ventilators, wall partitions, including joining cleats, glazing clips, snap beading, screws for fixing, etc., all aluminium sections as per relevant IS, complete all as specified & as directed. Note : Glass and rubber neoprene packing / rubber gasket shall be measured and paid for separately as “Supply only” under respective item of this Schedule.

249

-

-

... More
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. Note : Glass and rubber neoprene packing / rubber gasket shall be measured and paid for separately as “Supply only” under respective item of this Schedule.

350

-

-

... More
Supply only rubber neoprene packing / rubber gasket of required size & profile suitable for aluminium frame work in doors, windows, etc complete all as specified & as directed.

90

-

-

... More
Dismantling of brick tiles or terracing tiles, roof tiles single layer on roofs, complete all as specified and as directed. Note : Tiles shall be dismantled carefully and stacked properly including segregating the serviceable & unserviceable tiles as directed. Serviceable tiles shall be reused under the respective item of this Schedule.

1460

-

-

... More
Demolition of lime concrete of any description over roof slab, complete all as specified and as directed.

109.5

-

-

... More
M&L for 10mm thick plaster (screed bed) over roof slab in CM 1:4, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and as directed. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.

1460

-

-

... More
M&L for preparing surface and cleaning of concrete slaby by wire brushing and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 Kg per sqm including cleaning of surface and provide a layer of APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3mm thick, reinforced with polyester non woven fabric (weighing not less than 150 gms/sqm) laid on primed surface complete all as described in Para 11.44.5 of SSR Part-I, complete all as specified and as directed. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps.

1460

-

-

... More
M&L for Lime concrete terracing in roof with minimum thickness at edge 40mm and increasing uniformly towards ridges to obtain a chain slope of (1:40) as described in Para 11.27.2 of MES Schedule Part-I complete all as specified & as directed. Note : For lime concrete mudia kankar (Source : NAL) and Kolayat coarse sand in lieu of brick aggregate and surkhi respectively as specified in MES schedule Part-I shall be used.

109.5

-

-

... More
M&L for 40mm thick brick tiles, joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement, laid on roof over & including 15mm thick screed bed in cement & sand mortar 1:6, complete all as specified & as directed.

1010

-

-

... More
All as per serial item No. 58.00 here-in-before but except brick tiles complete all as specified & as directed. Note : Old serviceable brick tiles retrieved from serial item No 73.00 here-in-before shall be used under this item.

450

-

-

... More
M&L for 100mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base of floor, finished even and rough, complete all as specified and as directed.

59

-

-

... More
M&L for 75mm thick PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in sub base floor, finished even and smooth without using extra cement complete all as specified and as directed.

200

-

-

... More
M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded crushed stone aggregate as in flooring, leveling course, etc, surface finished fair and even, complete all as specified and as directed.

150

-

-

... More
M&L for machine cut Kota stone slab flooring 18 to 20mm thick laid over & including screed bed or bedding layer of 20mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.

60

-

-

... More
M&L for machine cut Kota stone slab 18 to 20mm thick on vertical surfaces such as dado, skirting etc. laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.

39

-

-

... More
M&L for 18 to 20mm thick Granite (of any type) machine cut slab of approved shade (table rubbed and polished) with true & uniform joints as in steps, jambs, pillars, window cills, cooking platforms & like and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed (bedding layer) in CM 1:4 with cement slurry @ 3 Kg/Sqm complete all as specified & as directed. Note : The exposed edges of granite stone slab shall be made full round & polished to mirror finish and rate quoted shall deemed to include this provision.

50

-

-

... More
Rounding (making full moulding) to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified & as directed.

100

-

-

... More
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.

30

-

-

... More
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.

310

-

-

... More
M&L for glazed ceramic tiles (coloured) 7mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e 450mm x 300mm or as directed), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.

300

-

-

... More
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.

26

-

-

... More
M&L for factory made 60mm thick machine pressed precast cement concrete coloured designer polished (reflecting type) interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment with coloured top casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & as directed. Note : Shape & colour of paver blocks shall be as approved by the GE.

59

-

-

... More
M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection/hardstanding surface, finished even and smooth without using extra cement, laid in panels including making joints 12mm wide to the full depth of PCC at every 3 metre and and at every change of direction and filling the same with and including bitumes and sand 1:3 by weight complete all as specified and directed.

120

-

-

... More
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls in Sunken portion, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.

35

-

-

... More
M&L for removal of loose concrete and cleaning the surfaces and filling the cracks with Polymer modified mortar using Dr Fixit Pidicrete URP or other equivalent product as approved by GE and thereafter applying two coats of Dr Fixit Bathseal WPC or other equivalent product as approved by GE in Sunken areas complete all as per manufacturer’s instructions, specified & directed. Note : Where contractor desire to use equivalent product of Dr Fixit Pidicrete URP and Dr Fixit Bathseal WPC, he shall submit the technical literature of equivalent products to establish the equivalency of products to the entire satisfaction of GE and both products shall be of same manufacturer as approved by the GE.

35

-

-

... More
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.

550

-

-

... More
M&L for 15mm thick rendering in two layer on fair faces of brick masonry or concrete surfaces of walls consisting of 1st layer of 10mm thick plaster in CM 1:4 and 2nd layer (setting coat or top layer) of 5 mm thick plaster in CM 1:4, 2nd layer mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished fair & even, complete, all as specified and directed. Note : - Supply only integral liquid water proofing compound shall be measured and paid for separately.

300

-

-

... More
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified and directed.

625

-

-

... More
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.

230

-

-

... More
M&L for preparation of newly plastered / unplastered surfaces of walls & applying three coats of white wash complete all as specified.

150

-

-

... More
M&L for preparation of old surfaces (plastered or unplastered) of walls including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying two coats of white wash complete all as specified & as directed.

750

-

-

... More
M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.

230

-

-

... More
M&L for preparation of old surfaces (plastered or unplastered) of ceilings including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying two coats of white wash complete all as specified & as directed.

1520

-

-

... More
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty complete all as specified & as directed.

450

-

-

... More
M&L for complete removal of existing treatment of walls including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil emulsion distemper (OBD) of approved shade/tint complete all as specified & as directed.

975

-

-

... More
M&L for preparation of newly plastered surfaces of wall including cornices, pillasters etc and applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed.

480

-

-

... More
M&L for complete removal of existing treatment of wall including cornices, pillasters etc by scraping donw and preparation of plastered surfaces and applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint on walls all as specified and as directed.

500

-

-

... More
M&L for preparation of new concrete surfaces and applying two coats of synthetic emulsion paint of approved shade/tint over a coat of primer complete all as specified & as directed.

30

-

-

... More
M&L for preparation of old surfaces by complete removal of existing treatment of painted wall including cornices, pillasters etc by mechanical equipment like electric wall sander and applying two coats of exterior emulsion/weather proof exterior grade paint of first quality by using over a coat of primer including sealing the cracks all as specified in manufacturers instruction Make STP Ltd (Shallcry-215) / Asian Paint (Apex Ultima) / Berger Paint (Weather coat long) complete all specified and as directed by GE.

925

-

-

... More
M&L for preparation of newly plastered surfaces of walls including cornices, pillasters etc by mechanical equipment like electric wall sander and applying two coats of exterior emulsion/weather proof exterior grade paint of first quality by using over a coat of primer including sealing the cracks all as specified in manufacturers instruction Make STP Ltd (Shallcry-215) / Asian Paint (Apex Ultima) / Berger Paint (Weather coat long) complete all specified and as directed by GE.

600

-

-

... More
Supply only sheet glass 5.5mm thick ordinary quality with glazing in required sizes, any size in each pane for metal frames, complete all as specified and as directed.

75

-

-

... More
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.

215

-

-

... More
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.

50

-

-

... More
M&L for rreparation of new/old steel and iron surfaces and applying two coats of epoxy anti corrossive paint over a coat of zinc primer complete all as specified and directed.

910

-

-

... More
Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 15mm bore complete all as specified and as directed.

350

-

-

... More
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.

250

-

-

... More
Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 15mm bore obtained serviceable vide serial item No. 114.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.

100

-

-

... More
Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 20mm bore complete all as specified and as directed.

150

-

-

... More
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.

100

-

-

... More
Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 20mm bore obtained serviceable vide serial item No. 117.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.

50

-

-

... More
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 20mm bore, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.

30

-

-

... More
M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 25mm bore, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.

30

-

-

... More
M&L for galvanized steel water tubing medium grade of 40mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 40mm bore, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.

20

-

-

... More
M&L for Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 20mm bore pipe fixed as in repairs complete all as specified and directed.

10

-

-

... More
M&L for Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 25mm bore pipe fixed complete all as specified and directed.

2

-

-

... More
M&L for Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 40mm bore pipe fixed complete all as specified and directed.

2

-

-

... More
M&L for cutting existing steel tubing for 20 to 50mm bore in position for alteration to required length for insertion of new branch, tee, collar, tail pieces, etc complete all as specified and directed. Note:- Excavation & earth work and fittings required for job shall deemed to be included in the rate quoted for this item.

2

-

-

... More
Disconnecting & taking down the existing unserviceable water tank and Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed. Note : (i) The water storage tanks shall be 2 layers, HDPE tanks moulded to seem-less perfection of rotational process. The tanks shall be manufactured only from FDA approved special grade of polyethylene and shall be certified fit for potable water. (ii) The tanks shall white coloured and ISI marked. Also refer paras 18.6 and 18.6A of MES Schedule Part-I. (iii) Payment for inlet, outlet and over flow pipes and ball valve shall be made separately. Howerver cost of providing necessary GI fittings such as nipples with check nuts for inlet and outlet pipes, GI plug with check nut for over flow pipe and 30cm long wash out pipe, GI 20mm nominal bore, medium grade and check nut for wash out pipes of size as per actual requirements as directed by Engineer-in-Charge shall be deemed to be included in the unit rates of this item.

10

-

-

... More
S&F in repairs Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20mm bore (minimum weight 210 gms) complete all as specified and as directed.

10

-

-

... More
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., with plastic WC seat cover (white) closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device, Jet spray (brass chromium plated of butterfly shape) with 1.00m PTMT tube suitable for 15 mm bore GI pipe with PTMT nut & nipple, complete all as specified & as directed.

10

-

-

... More
S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified & as directed.

10

-

-

... More
S&F in repairs vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed.

10

-

-

... More
S&F sink made of stainless steel 1mm thick for Kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to brick wall, connecting union to pipe, overall minimum size 495mm x 420 mm with bowl size 410mm x 330mm x160 mm including 40mm dia waste pipe of polythelene of low or high density, 40mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0, complete all as specified and as directed including taking down old unserviceable sink with fittings.

10

-

-

... More
S&F in repairs stainless steel Kitchen plate rack of overall minimum size 900mm x 600mm and 230mm deep, with partitions for small/large plates etc, made out of stainless steel sheet 24 Gauge, fixed with rawl plug and CP steel screws complete all as specified and as directed. Note : Weight of rack shall not be less than 6.00 Kg.

10

-

-

... More
S&F in repairs PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified & as directed.

50

-

-

... More
S&F in repairs 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes, complete all as specified & as directed.

10

-

-

... More
S&F in repairs 15mm bore bib tap, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & as directed.

50

-

-

... More
S&F 15mm bore Angle stop valve, fancy type with long shank and cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed.

10

-

-

... More
S&F in repairs 25mm bore Stop valve, fancy type and cast copper alloy chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified & as directed.

10

-

-

... More
S&F in repairs 600mm x 450mm looking mirror of selected quality glass not less than 5.5mm thick, mounted on 6mm thick AC building board or commercial plywood including aluminium framing and fixed to PVC rawl plugs with chromium plated brass screws and cup washers complete all as specified.

10

-

-

... More
S&F in replacement of brass chromium plated shower rose 125mm size with shower arm including fixing to steel pipe of 15mm bore or union complete all as specified and as directed.

10

-

-

... More
S&F in repairs tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified and as directed.

10

-

-

... More
S&F in replacement of Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 150mm, fixed in floor, complete all as specified and as directed.

50

-

-

... More
S&F in repairs corner glass shelf of size 300mmx300mm with 5.5mm thick glass and stainless steel clip and stainless steel railing allround the shef complete all as specified and directed. Make : Parryware / Jaquar / Marc / Kingston / Somany / Ess Ess / Sieco / Kohler / Hindware / Prayag / Parko

10

-

-

... More
Supply and fixing in replacement of 100mm bore (Spun Pipe) cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches or floors, complete all as specified and as directed.

9

-

-

... More
Supply and fixing in replacement of 75mm bore (Spun Pipe) cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches or floors, complete all as specified and as directed.

12

-

-

... More
Supply and fixing in replacement of 100mm bore (Spun Pipe) cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, fixed to walls, complete all as specified and as directed.

30

-

-

... More
Supply and fixing in replacement of 75mm bore (Spun Pipe) cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, fixed to walls, complete all as specified and as directed.

32

-

-

... More
S&F stack clamp made out of MS flat 50mm x 5mm and 16 mm dia round iron stays, including bolts & nuts, securing ends of stays to walls or roof for 100mm bore pipe including two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified & as directed.

15

-

-

... More
S&F stack clamp made out of MS flat 50mm x 5mm and 16 mm dia round iron stays, including bolts & nuts, securing ends of stays to walls or roof for 75mm bore pipe including two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified & as directed.

15

-

-

... More
S&F in replacement of 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified & as directed.

6

-

-

... More
S&F in replacement of 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified & as directed.

6

-

-

... More
S&F in replacement of 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) without oval access door complete all as specified & as directed.

10

-

-

... More
S&F in replacement of 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) without oval access door complete all as specified & as directed.

6

-

-

... More
S&F in replacement of 100mm bore cast iron TEE (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified & as directed.

6

-

-

... More
S&F in replacement fo 100mm bore cast iron bends (any radius), with duck's foot or heel rest with oval access door complete all as specified & as directed.

5

-

-

... More
S&F in replacement of 100mm bore cast iron branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified & as directed.

8

-

-

... More
S&F in replacement of 75mm bore cast iron branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified & as directed.

6

-

-

... More
Supply and fixing cast iron vent cowl for 5 mm bore CI pipe complete all as specified.

6

-

-

... More
M&L for extra over cast iron pipe & fitting 100mm bore providing lead joints in lieu of cement joints complete all as specified and as directed.

29

-

-

... More
M&L for extra over cast iron pipe & fitting 75mm bore providing lead joints in lieu of cement joints complete all as specified and as directed.

30

-

-

... More
S&F in repairs cast iron floor trap of 75 mm bore, with grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4), complete all as specified & as directed.

20

-

-

... More
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints for weep holes complete all as specified & as directed.

10

-

-

... More
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls complete all as specified & as directed.

50

-

-

... More
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls complete all as specified & as directed.

50

-

-

... More
S&F 110mm bore PVC (SWR) bend any redius, joint with solvent cement complete all as specified & as directed.

12

-

-

... More
S&F 75mm bore PVC (SWR) bend any redius, joint with solvent cementcomplete all as specified & as directed.

12

-

-

... More
S&F PVC (SWR) Gully trap 125/110mm bore setting and jointing with solvent cement complete all as specified & as directed.

10

-

-

... More
S&F in repairs 32mm/40mm dia PVC flexible waste pipe for WHB/urinal/sink with coupling fixed, complete all as specified and as directed.

20

-

-

... More
S&F in repairs Grating 75mm dia of stainless steel with and without hole having minimum weight 75gm complete all as specified and as directed.

20

-

-

... More
S&F in repairs Grating 100mm dia of stainless steel with and without hole having minimum weight 75gm complete all as specified and as directed.

30

-

-

... More
M&L for salt glazed stone ware gully trap square or round mouthed type 'P' of size 150 x 150 mm with CI grating, setting & jointing with cement with grouting surrounding gully trap with PCC 1:3:6, type C1 block 30x30x45cm together with necessary form work, excavation & earth work in soft/loose soil, complete all as specified and as directed.

2

-

-

... More
S&F salt glazed stone ware drain pipes of 150mm bore, Class ‘SP 2’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested including demolition and breaking up 150mm bore drain pipes set in cement mortar including PCC haunching and bedding, complete all as specified and as directed.

65

-

-

... More
M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipe complete all as specified and as directed.

60

-

-

... More
Structural design for Roof Slab, Beams, Chajja and other connected RCC members required to be re-constructed under this Schedule with & including vetting of structural design from approved Govt Engineering College/NITTTR/CBRI, complete all as specified and as directed. Notes : (i) Tenderer shall carryout the site visit to ascertain the size of slab, other RCC members, arrangement of rooms, etc required for design purpose. (ii) Four sets of Structural drawings shall be provided to GE by the contractor duly vetted as above.

1

-

-

... More
M&L for Valve Pit Chamber of internal size 90cm x 90cm x 60cm built in brick masonry complete all as specified in Particular Specifications and as shown on drawing No. BTD-811 Sheet No. 1/2 & 2/2.

1

-

-

... More
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/ batten/ casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.

466

-

-

... More
M&L for Modular point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular switches, sockets, regulators etc with and including modular cover plates with frame of requisite module, complete all as specified and as directed. Notes : (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed to include for modular metal flush boxes of requisite module and modular cover plates with frame of requisite module of colour as approved by GE.

234

-

-

... More
All as per serial item No. 177.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.

24

-

-

... More
All as per serial item No. 177.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.

134

-

-

... More
All as per serial item No. 177.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.

54

-

-

... More
All as per serial item No. 177.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.

20

-

-

... More
S&F Modular switch 1 way 6A, 1 module, complete all as specified and as directed.

392

-

-

... More
S&F Modular switch, 1 way 16 Amp, 1 module, complete all as specified and as directed.

54

-

-

... More
S&F Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed.

158

-

-

... More
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and as directed.

54

-

-

... More
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.

126

-

-

... More
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed.

68

-

-

... More
S&F Modular Fan step regulator, 120 Watt - 2 module, complete all as specified and as directed.

30

-

-

... More
S&F bell push, flush type, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.

10

-

-

... More
Supply and fixing Bell ‘Ding Dong’ / ‘Multi Music’ Type, AC, 230 Volts, ISI marked, complete all as specified and as directed.

10

-

-

... More
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt 240 Volt, 50 Hz AC, ISI Marked decorative type with driver holder and LED lamp, correlated colour temperature shall be minimum 6500 degree Kelvin, including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make: Model “LDL-10-WW” of M/S Crompton/ Wipro Cat Part No. LL20-111-XXX-65NE3/ Cat Part No. ENDURALINEARNEOBS10WLED865SPCWH of Havells/ or equivalent in makes mentioned in Appendix 'B' here-in-after.

10

-

-

... More
Taking down of serviceable and refixing after LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.

40

-

-

... More
S&F LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed. Make : Philips, Cat Part No. LED 20S PSU CW GR S2/ Crompton Greaves, Cat Part No. LDDR20-CDL Dazzle Ray/ Bajaj, Cat Part No. BCLAB 20W or equivalent make here-in-after in appendix 'B'

40

-

-

... More
S&F bulk head energy efficient LED light fitting, 1x10 Watt, 230 Volts, surface mounted, comprising of high brightness LEDs, IP-65 protection, with & including all standard accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed. Make : Havells Cat Part No. RUGBYNEONFT10WLED860SSYM TOPC or equivalent in makes mentioned in Appendix ‘B’ here-in-after.

20

-

-

... More
Supply and Fixing Light Emitting Diode (LED) based street/ security light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt and a minimum system lumen output of not less than 3000 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA /polycarbonate /toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multi stranded copper conductor cable of 1100 Volt grade (ISI marked), fixed in repairs, complete all as specified and as directed.

16

-

-

... More
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.

-

-

-

... More
Supply and fixing in replacement of mounting bracket (suitable for fixing/holding street/ security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.50m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, complete all as specified and as directed.

16

-

-

... More
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 230 Volt, 10 kA, ‘C’ Curve, fixed in repairs, complete all as specified and as directed.

20

-

-

... More
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, ction, IK-09 with metal door suitable for fixing MCBs, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, VTPN, DB, vertical load line, 8 way, 415 Volts, suitable fitted, including taking down old existing unserviceable DB with fixtures of any type complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.

2

-

-

... More
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, suitable for fixing MCBs/MCCBs, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, SPN, DB, 8 way, suitable for MCB, complete all as specified and as directed including taking down old existing unserviceable DB with fixtures of any type & capacity :- Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.

10

-

-

... More
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.

84

-

-

... More
S&F MCB, 6 to 32 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.

2

-

-

... More
S&F MCB, 40 Amps, Double Pole, 415 Volts, 10 kA, ‘D’ Curve, with over load and short circuit protection, complete all as specified and as directed.

20

-

-

... More
S&F in replacement of MCCB 4 Pole 100 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt, ISI Marked complete all as specified and directed.

2

-

-

... More
Taking down fan, sealing cable end, dismantling blades and removing fan and blades & refixing ceiling fan of any make, any sweep, keeping side to store in safe custody for painting of ceiling fans complete, insitu with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed.

30

-

-

... More
M&L for carefully disconnecting electric & water connections and taking down existing serviceable Geyser (water storage type) of capacity 25/50 litre vertical type and re-fixing the same with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of suitable size but not less than 10mm dia 125mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original and re-connecting electric & water connections, complete all as directed.

10

-

-

... More
Taking dwon and refixing tamper proof energy meter electronic type single phase 10-60 Amps current rating single phase 230 Volt AC with electric connection and necessary fixing arrangement complete all as specified and directed.

10

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.

6

-

-

... More
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.

200

-

-

... More
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.

100

-

-

... More
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.

105

-

-

... More
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :-(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.

14

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm confirming to IS -5820 complete all as specified and as directed.

1070

-

-

... More
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.

10

-

-

... More
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.