Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Solar Installation and Products
Electrical Works
Eprocure
Opening Date21 Dec 2024
Closing Date18 Jan 2025
Tender Amount₹ 80,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per Item No 2.00 here-in-before but capacity 45 watt

120

-

-

... More
All as per Item No 2.00 here-in-before but capacity 60 watt

120

-

-

... More
All as per Item No 2.00 here-in-before but capacity 70 watt

80

-

-

... More
All as per Item No 2.00 here-in-before but capacity 90 watt

80

-

-

... More
All as per Item No 2.00 here-in-before but capacity 150 watt

30

-

-

... More
All as per Item No 2.00 here-in-before but capacity 200 watt

50

-

-

... More
All as per Item No 2.00 here-in-before but capacity 250 watt

40

-

-

... More
All as per Item No 2.00 here-in-before but capacity 400 watt

20

-

-

... More
S&F in repair Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified and directed by Engineer-in-charge.

60

-

-

... More
Labour only for making serviceable street/security lights/solar light unserviceable placed at pole by disconnection / Isolating power supply either from pole junction box or by disconnecting overhead conductor and carrying out de-carbonization / de-sulphation at connection points with overhead conductor / light fitting / junction box terminal including replacement connection wire complete all as specified and directed by Engineer-in-charge. Note : - Cable shall be measured and paid seprately.

750

-

-

... More
S&F Led Street Light Of Capacity 45 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 110 Lumens/Watt, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. complete all as specified and directed by Engineer-in-charge. Make – Crompton/Havells/Wipro Cat No crompton TRP-409-45-57-SL-GL-NSG, Havells:- ENDURASUNDOWNSL45WLED765PASYBOTG Wipro Cat No-LR02-671-XXX-57-G3 or equivalent make and model as approved by GE.

75

-

-

... More
S&F Led Street Light Of Capacity 60 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 110 Lumens/Watt with toughend glass , Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. complete all as specified and directed by Engineer-in-charge. Make – Crompton/Havells/ Wipro crompton cat No TRP-409-60-57-SL-GL-NSG, Havells Cat P. No ENDURAOMNIPLUSSL60WLED757SASYTOPC, Wipro Cat No-LR02-671-XXX-57-G3 or equivalent make and model as approved by GE.

75

-

-

... More
S&F Led Street Light Of Capacity 90 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 110 Lumens/Watt with toughend glass , Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. complete all as specified and directed by Engineer-in-charge. Make – Crompton/Bajaj/orient crompton cat No TRP-411-90-57-SL-GL-NSG,Bajaj Cat P. No ENXTP108L WH CR TG SD, Orient Cat No-LSFS-090-C or equivalent make and model as approved by GE.

50

-

-

... More
S&F Led Flood Light Fitting 150 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy = 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver. Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X Frlsh Wire, complete all as specified and directed by Engineer-in-charge. Make – Crompton/Havells/Bajaj Crompton Cat no CFS-507-150-57-60 D-SL-GL-NSG, Bajaj Cat no:- JENXT P180L WH PO TG SD Orient Cat no:-Orient cat no:LFSM-150-C-V3 or equivalent make and model as approved by GE.

37

-

-

... More
S&F Led Flood Light Fitting 200 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy = 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver. Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X Frlsh Wire, complete all as specified and directed by Engineer-in-charge. Make – Crompton/Havells/Orient Crompton Cat no CFS-501-200--57-60 D-SL-GL-NSG, Havells Cat no:- JETAIRIMAXFL200WLED757PWBLTG, Orient Cat no:- :LFSM-200-C-V3 or equivalent make and model as approved by GE.

55

-

-

... More
S&F Led Flood Light Fitting 250 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy = 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver. Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X .. Frlsh Wire, complete all as specified and directed by Engineer-in-charge. Make :- Crompton Cat Part No. CFS-506-250-57-60D-SL-GL-NSG, Havells Cat Part No :- JETAIRIMAXFL250WLED757PWBLTG, Orient cat Part No: LFSM-250-C-V3 or equivalent make and model as approved by GE.

55

-

-

... More
S&F Led Flood Light Fitting 400 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy = 120lm/W And Total Lumens Output Must Be = 48,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F 0.95, , Cct – 5700k, Of Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Seperate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver. Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X Frlsh Wire, complete all as specified and directed by Engineer-in-charge. Make:- Crompton Cat Part No. CFS-506-400-57-60 SL-GL-NSG, Havells Cat aprt No. JETAVALOURLEFL400W3MLED757PINTNBLTG, Orient cat Part No. LFSMU-400-C or equivalent make and model as approved by GE.

50

-

-

... More
S&F in repair of PVC insulated, sheathed weather proof, copper conductor of size 1.5 sqmm, 3 core complete all as specified and directed by Engineer-in-charge.

360

-

-

... More
S&F in repair of PVC insulated, sheathed weather proof, aluminium conductor of size 6 sqmm, 2 core complete all as specified and directed by Engineer-in-charge.

500

-

-

... More
S&F in repair of PVC conduit 20 mm, heavy duty rigid non metallic including of all tee, bends, elbows etc complete all as specified and directed by Engineer-in-charge.

300

-

-

... More
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) and including one coat of red oxide primer and two coat of aluminium paint over a pole including dismantlaing/taking out existing PCC/Steel tubular pole and making surface good complete all as specified and directed by Engineer-in-charge.

20

-

-

... More
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation for PCC poles/struts including necessary form work complete all as specified and directed by Engineer-in-charge.

2.16

-

-

... More
M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of stay assembly including necessary form work complete all as specified and directed by Engineer-in-charge.

19.2

-

-

... More
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.

6.8

-

-

... More
Supply & Installation in repair of Mono crystalline Solar PV Panel of 12V 135Wp (Suitable for 30Watt solar light) with wires and connectors to fit in existing system,complete all as specified and directed by Engineer-in-charge.

10

-

-

... More
Supply & Installation in repair of Mono crystalline Solar PV Panel of 12V 80Wp (Suitable for 9 to 12Watt solar light) with wires and connectors to fit in existing system,complete all as specified and directed by Engineer-in-charge.

10

-

-

... More
S&F in repair, galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1m, Stright/bend to required shape(as per ground condation) with clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etccomplete for fixing street light fittings complete all as specified and directed by Engineer-in-charge.

55

-

-

... More
S & F in repair of PVC insulated, sheathed weather proof, copper conductor of size 2.5 sqmm, 2 core complete all as specified and directed by Engineer-in-charge.

500

-

-

... More
Supply & Installation in repair of 12 watt LED street light Luminary for solar light with inbuilt charge controller, High brightness W-LED(120-180lm/watt) lamp with proper optics lens for better light distribution , CRI 70, Color Temperature 6500K, Microcontroller based charge controller cum driver, automatic dimming function, Dusk to Down Operation, Protections: Short Circuit, overload, Reverse polarity and battery protections. With Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS, IP66 and IK08 Compliant complete all as specified and directed by Engineer-in-charge.

30

-

-

... More
Supply & Installation in repair of 30 watt LED street light Luminary for solar ;light with inbuilt charge controller, High brightness W-LED(120-180lm/watt) lamp with proper optics lens for better light distribution , CRI 70, Color Temperature 6500K, Microcontroller based charge controller cum driver, automatic dimming function, Dusk to Down Operation, Protections: Short Circuit, overload, Reverse polarity and battery protections. With Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS, IP66 and IK08 Compliant complete all as specified and directed by Engineer-in-charge.

30

-

-

... More
Supply & Installation in repair of Maintenance free lead Acid VRLA type Battery 12V 80 Ah (Suitable for solar street light,warrenty minimum 24 month of battery) with other necessary wires and connectors suitable for existing system complete all as specified and directed by Engineer-in-charge. Make :- Exide,amron,luminious

30

-

-

... More
Supply & Installation in repair of Maintenance free lead Acid VRLA( maintance free battery type Battery 12V 40 Ah with charge controller (Suitable for solar street light warrenty up to 36 month of battery) with other necessary wires and connectors suitable for existing system complete all as specified and directed by Engineer-in-charge.

56

-

-

... More
S&F in repair of Solar Charge Controller for inbuilt solar street light all in one MPPT 10 Amp with protection circuit Solar street Light System: 12V Nom inal Capacity: 80Wp Max Regulation: Low Loss, Shunt Type OVD: Output Voltage Drop complete all as specified and directed by Engineer-in-charge.

25

-

-

... More
S&F in repair of of PIR Motion Sensor 170uA for Solar street Light all in one Standard Detection 5m Lens Color : White complete all as specified and directed by Engineer-in-charge.

25

-

-

... More
S&F in repair Lithium Battery 12.8V/ 42 Ah (Suitable for 16 to 40 Watt solar light) with BMS Circuit and other necessary wires and connectors suitable for 16 to 40 watt Integrated all in one Solar Lights complete all as specified and directed by Engineer-in-charge.

50

-

-

... More
S&F in repair of Lithium Battery 12.8V/ 36Ah (Suitable for 12 to 16Watt solar light) with BMS Circuit and other necessary wires and connectors complete all as specified and directed by Engineer-in-charge.

50

-

-

... More
S&F in reapir of Rocker Switch 6Amp to 10Amp for solar lights complete all as specified and directed by Engineer-in-charge.

20

-

-

... More
S&F in repair solar street light of 20 watt all in one FRP/Aluminium extruded Lithium based energy efficient Integrated with polyurethane coating camouflag colour servicable battery compartment, solar PV panel of 35-40 WP mono crystalline,, Lithium battery 12.8 Volt, 18-24 Ah LiFeP04 , Min Lux level 3000 Lumens ,MPPT Charger with inbuit BMS Technology ,PIR motion sensor system at 30% start dimming brightness glow to 100% for 30 second upon motion detection High brightness luminous efficiency W-LED (135-180 Im/Watt),life span of of LED 50,000 Hrs , protection lamp with aluminium reflector for better lighting distribution, CRI 70, colour temperature 5700 ANSI, Microcontroller based charge controller cum driver in built DC type, automatic fix motion dimming function with PIR motion sensor,Dusk to dawn operation, ,working temp : (-10 C ) to (+) 55 C ,humidity range 0-95%, with adjustable MS Clamp suitable for existing pole/wall mounting ,low votage indication ,charging indication ,with bty over charge protcetion ,Bty deep discharge protection ,No load/Open load protection etc complaint complete all as specified and directed by Engineer-in-charge. Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS , IP65/ 66 and IKO8 Make :- Crompton cat no-CSOP-814-20-57-HL5-FD-LM-SR or equivalent make and model as approved by GE.

21

-

-

... More
S&F in repair solar street light of 30 watt all in one FRP/Aluminium extruded Lithium based energy efficient Integrated with polyurethane coating camouflag colour servicable battery compartment, solar PV panel of 48-60 WP mono crystalline,, Lithium battery 12.8 Volt, 24-30 Ah LiFeP04,Min lux level 4500 lumens ,MPPT Charger with inbuit BMS Technology ,PIR motion sensor system at 30% start dimming brightness glow to 100% for 30 second upon motion detection High brightness luminous efficiency W-LED (150-180 Im/Watt),life span of of LED 50,000 Hrs , protection lamp with aluminium reflector for better lighting distribution, CRI 70, colour temperature 5700 ANSI, Microcontroller based charge controller cum driver in built DC type, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR motion sensor,Dusk to dawn operation,and ,working temp : (-10 C ) to (+) 55 C ,humidity range 0-95%, weight 15-20 KG with adjustable MS Clamp suitable for existing pole/wall mounting ,low votage indication ,charging indication ,with bty over charge protcetion ,Bty deep discharge protection ,No load/Open load protection etc complaint complete all as specified and directed by Engineer-in-charge. Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS , IP 66 and IKO8 complaint. Make :- Crompton cat no-CSOP-815-30-57-HL5-PIR-LM-SR or equivalent make and model as approved by GE.

10

-

-

... More
S&F in repair solar street light of 40 watt all in oneFRP/ Aluminium extruded Lithium based energy efficient Integrated with polyurethane coating camouflag colour servicable battery compartment, solar PV panel of 48-60 WP mono crystalline,, Lithium battery 12.8 Volt, 24-30 Ah LiFeP04,Min lux level 4500 lumens ,MPPT Charger with inbuit BMS Technology ,PIR motion sensor system at 30% start dimming brightness glow to 100% for 30 second upon motion detection High brightness luminous efficiency W-LED (150-180 Im/Watt),life span of of LED 50,000 Hrs , protection lamp with aluminium reflector for better lighting distribution, CRI 70, colour temperature 5700 ANSI, Microcontroller based charge controller cum driver in built DC type, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR motion sensor,Dusk to dawn operation,and ,working temp : (-10 C ) to (+) 55 C ,humidity range 0-95%, weight 15-20 KG with adjustable MS Clamp suitable for existing pole/wall mounting ,low votage indication ,charging indication ,with bty over charge protcetion ,Bty deep discharge protection ,No load/Open load protection etc complete all as specified and directed by Engr-in-Charge. Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS , IP 66 and IKO8 complaint. Make :- Crompton cat no-CSOP-815-30-57-HL5-PIR-LM-SR or equivalent make and model as approved by GE.

10

-

-

... More
S&F in repair of copper wire 2.5 Sqmm 6 core suitable for high mast light complete all as specified and directed by Engineer-in-charge.

350

-

-

... More
Taking down and dismantling existing high mast pole of height 12 to 20 mtr from bottom plate ,nuts bolts, gear box and head frame for dismantling the unserviceable parts including repair control panel wiring, old unsv lights, complete with the help of suitable T & P required for holding, lifgting the pole replacement of unservicable part,oiling and greasing,of pulleys,gear box, rope and all moving parts including assembling, installation of high mast pole complete all as specified and directed by Engineer-in-charge. Note:- 1. cost of crane for dismantling high mast pole is deemed to be included in quoted rate. 2. Cost of oling and greasing of moving parts is deemed to be quoted rate.

38

-

-

... More
Taking down by disconnected the existing electrical connection of winch motor for rewinding /repairs including rewinding the mortor of capacity up to 2 HP with best class supper enameled copper wire of existing guage and size including varnishes and insulating 230 V AC 50 HZ electric supply system refixing and reconnected it to the original location for satisfactory functioning of wintch on 230 v electric supply system complete all as specified and directed by Engineer-in-charge.

15

-

-

... More
S&F MNX Power contactor suitable for power supply 40 Amps 4 pole 4 NO Contactor including making electrical connection to the contactor complete all as specified and directed by Engineer-in-charge. Make: Legrand/ Havells /L&T as approved by GE.

15

-

-

... More
S&F MNX Power contactor suitable for power supply 63 Amps 4 NO Contactor including making electrical connection to the contactor complete all as specified and directed by Engineer-in-charge. Make: Legrand/ Havells /L&T as approved by GE.

15

-

-

... More
S&F in repair Digital Astronomical timer switch 240V AC-2W,C/O, Base/DIN type complete for switching of contactors complete all as specified and directed by Engineer-in-charge.

15

-

-

... More
S&F in repair Nature switch (using infrared sensor technology) based automatic street light control panel. The panel should be enough to take three phase load of 3-5 kw. Nature switch operation should be based on natural light luxes. required illuminance level switching ON is =60 and for Switching OFF =10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable 3 phase load of 3-5 KW with 3 nos contractor ,3 nos Incoming MCBs of 63 Amps and outgoing MCBs of 63 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof ,Electric shock proof ,Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor Manual or Auto operation complete all as specified and directed by Engineer-in-charge. Make :- Kakatiya Energy system,SW , Indoasian, L&T as approved by GE.

5

-

-

... More
S&F MCB, SPN, 32 Amp, 240 Volts, 'C' Curve 10KA including dismantling old onecomplete all as specified and directed by Engineer-in-charge.

30

-

-

... More
S&F 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB/ Panel box/ feeder piller box complete with connection testing and commissioning.MCB, TPN 40 Amp, including taking down/ dismantling old onecomplete all as specified and directed by Engineer-in-charge.

15

-

-

... More
S&F 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB/ Panel box/ feeder piller box complete with connection testing and commissioning.MCB, TPN 63 Amp, including taking down /dismantling old one complete all as specified and directed by Engineer-in-charge.

15

-

-

... More
S&F MCB, single pole, 16-32 Amp, 240 Volts, 'C' Curve 10KA including dismantling old one complete all as specified and directed by Engineer-in-charge.

10

-

-

... More
S&F MCCB 415V, 3 phase 50 HZ 4 pole 63 Amps breaking capacity 16 KA (Ics = 100% Icu) with including dismantling old one connection link on LT panel /fedder piller complete all as specified and directed by Engineer-in-charge.

3

-

-

... More
S&F MCCB 415V, 3 phase 50 HZ 4 pole 125 Amps breaking capacity 16 KA (Ics = 100% Icu). with including traking down/dismantling old one connection link on LT panel /fedder piller Complete complete all as specified and directed by Engineer-in-charge.

3

-

-

... More
S&F MCCB 415V, 3 phase 50 HZ 4 pole 100 Amps breaking capacity 16 KA (Ics = 100% Icu) with including dismantling old one connection link on LT panel /fedder piller complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
Taking down/out unserviceable LT UG Cable of any descriptions, laid in trenches and/or fixing with Walls/Poles including stone patti complete all as specified and directed by Engineer-in-charge.

3550

-

-

... More
Supply ,laying, test and commissioning of LT UG , XLPE insulated, heavy duty, 1100V grade of electric cable size 10 Sqmm 4 core with aluminium conductor ,served with an inner sheathing of PVC tape armoured eith galvanized steel wire or tape and overall PVC sheathed,laid in trench or passing through pipe, making all connection with and including provision of necessary glands ,lugs,bushing etc as required complete all as specified and directed by Engineer-in-charge. Note : Earthwork excavation sand cushioning ,Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items.

750

-

-

... More
All as per Item No. 59.00 here-in-before but size 10 Sqmm 2core

500

-

-

... More
All as per Item No. 59.00 here-in-before but size size 16 Sqmm 4core

750

-

-

... More
All as per Item No. 59.00 here-in-before but size size 25 Sqmm 4core

750

-

-

... More
All as per Item No. 59.00 here-in-before but size size 35 Sqmm 3.5 core

500

-

-

... More
All as per Item No. 59.00 here-in-before but size size 50 Sqmm 3.5 core

500

-

-

... More
Relaying of old retrieved servicable LT UG cable of any size /any core complete all as specified and directed by Engineer-in-charge.

300

-

-

... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or soil for shaft walls,cesspits ,manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil /disintegrated rock complete all as specified and directed by Engineer-in-charge.

955

-

-

... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil/disintigrtaed rock complete all as specified and directed by Engineer-in-charge.

571

-

-

... More
Removing excavated Material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of soil/disintigrtaed rock complete all as specified and directed by Engineer-in-charge.

384

-

-

... More
M&L for laying 40 to 50 mm thick roughly hammer dressed jodhpur stone patti cable cover 25 cm to 30 cm wide and not exc 60 cm long each laid dry abuting with each other with maximum gap between adjacent patti/ slabs not exc 10 mm complete all as specified and directed by Engineer-in-charge.

813

-

-

... More
M&L for cushioning with layers of sand 8 cm before laying of cable & 15 cm after laying of cable (total 23 cm ) in trenches, duly punning to a thickness of 18 cm for cable protection complete all as specified and directed by Engineer-in-charge. Note:- Thickness after punning shall be measured for payment.

288

-

-

... More
Re-laying only of existing Jodhpur Stone Patti cable cover in Trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 58.00 here-in-before) complete all as specified and directed by Engineer-in-charge.

75

-

-

... More
S & F in repair of GI Pipe of 80mm in single length ( 20 feet/6 Mtr ) for solar street lights complete all as specified and directed by Engineer-in-charge.

156

-

-

... More
S&F in repair pole mounted junction box of outer size 300x200x120mm made out of FRP body (hot mulded type) with IP-66 protection and locking with screws alongwith 6-32 Amp rating MCB SP-01 No, up to 50 Amp rated 4 pole connector suitable to insert the cable size up to 25 sqmm x 4 core -02 No and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cables and complete all as specified and directed by Engineer-in-charge.

80

-

-

... More
S&F in repair, galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.

25

-

-

... More
M&L for straight through(Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 10/50 SQmm including dismantling the old burnt cable joint termination complete all as specified and directed by Engineer-in-charge.

10

-

-

... More
M&L for preparation of old painted surface of LT Concrete electric pole of any size by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height 1.5 mtr above the ground level, including painting the cross arms/bracing/brackets support on poles with a coat of aluminium paint, silver colour aluminium paint with coating of primer and writing of identification Nos with proper stencil cut etc as per directions complete all as specified and directed by Engineer-in-charge.

400

-

-

... More
M&L for preparation of old painted surface of LT Steel tubular pole of any length by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing /brackets/clamps & nut and bolts cross arms/support on poles and writing of identification Nos with proper stencil cut etc as per directions by complete all as specified and directed by Engineer-in-charge.

400

-

-

... More
M&L for preparation of old painted surface of F/P box/LT Panel by removing all dirt, dust, etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour over a coat of primer including writing of identification with proper stencil cut etc as per directions complete all as specified and directed by Engineer-in-charge.

13

-

-

... More
Supply and fix Din type HRC fuse link of Required rating 32A/63A/100A Suitable for HG type 20H/2 complete all as specified and directed by Engineer-in-charge. Make:-Seimens/L&T/Havells.

100

-

-

... More
S&F Nature switch( using infrared sensor technology ) based automatic street light control panel. The panel should be enough to take three phase load of 25 kw. Nature switch operation should be based on natural light luxes. required illuminance level switching ON is =60 and for Switching OFF =10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable 3 phase load of 25 KW with 3 nos contractor ,3 nos Incoming MCBs of 63 Amps and outgoing MCBs of 63 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof ,Electric shock proof ,Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor Manual or Auto operation complete all as specified and directed by Engineer-in-charge. Make :- Kakatiya Energy system,SW , Indoasian, L&T as approved by GE.

3

-

-

... More
S&F Retro Reflective Tape 3 inch width red and yellow colour sutiable for steel tubular pole and RCC Pole complete all as specified and directed by Engineer-in-charge.

270

-

-

... More
S&F in repair 40 mm bore GI tubing medium grade in trenches or on pole for cable protection complete all as specified and directed by Engineer-in-charge.

36

-

-

... More
Supply & fix in repair 50 mm bore GI tubing medium grade in trenches or on pole for cable protection complete all as specified and directed by Engineer-in-charge.

36

-

-

... More
M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-charge.

40

-

-

... More
Note :- (i) Contractor has to arrange his own vehicles along with mounted hydraulic ladder/articulated & telescopic boom lift arrangement for attending the complaint throughout jaisalmer cantt area. (ii) Contractor shall depute minimum 2 staff daily to attend and rectify the complaint. if not, Contractor shall have to bear a penalty of Rs 50.00 per complaint or maximum of Rs 500 per day on this account (iii) Complaints has to attend and rectify the complaint/defect irrespective of no of trips/Complaints as alloted by Eng-in-Charge. (iv) Complaint should be attend in Night also (v) Contractor has to arrange telescopic boom lift for maintenance at height of 15m at his own cost. No extra payment will be paid by department.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.