Military Engineer Services Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Feb 2025
Closing Date25 Feb 2025
Tender Amount₹ 46,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/ MAINTENANCE OF HT EXTERNAL ELECTRIFICATION AND LT PANEL, BUS BAR AND OTHER ALLIED WORKS IN NORTHERN AND CENTRAL SECTOR AT MIL STN KOTA
REPAIR/ MAINTENANCE OF HT EXTERNAL ELECTRIFICATION AND LT PANEL, BUS BAR AND OTHER ALLIED WORKS IN NORTHERN AND CENTRAL SECTOR AT MIL STN KOTA
REPAIR/ MAINTENANCE OF HT EXTERNAL ELECTRIFICATION AND LT PANEL, BUS BAR AND OTHER ALLIED WORKS IN NORTHERN AND CENTRAL SECTOR AT MIL STN KOTA
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L dry river clean Sand filling in trenches around underground cables for earth cushion, complete all as specified and directed. (Depth of sand shall be measured after punning).

96.4

-

-

... More
Supplying and laying in renewal of un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm laid dry and flat adjoining each other over sand cushion in trenches as protection to UG cable, complete all as specified and directed.

2000

-

-

... More
M&L for pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), class 10, laid dry and flat adjoining each other over sand cushion in trenches as protection to UG cable, complete all as specified and directed.

7

-

-

... More
M&L for taking down old existing serviceable XLPE cable of any size from trenches, culvert, road and re-routing, re-laying and reconnecting, testing the same in existing location or any other location, complete all as specified and directed. Note :- Excavation & earth work , GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respectiv items of the BOQ.

400

-

-

... More
M & L for hardcore broken stone or boulders aggregate of size 25 to 40 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface at 4 Pole, 2 Pole strucutres and other E&M Installations complete all as specified and directed.

108.8

-

-

... More
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint & including dismantling of old unserviceable cross arms of MS channel or angle sections etc complete all as specified and directed.

0.5

-

-

... More
M&L for pin type, porcelain, vitreous, white, borwn or green insulator, including one galvanised mild steel spindle, two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade & including dismantling of old unserviceable insulator, complete all as specified and directed.

4

-

-

... More
M&L for insulator disc type porcelain, vitreous, 145 mm high and 255 mm dia ball and socket type, white, brown or green for tension with tension clamps for conductor, working pressure 11000 volts & including dismantling of old unserviceable insulator, complete all as specified and directed.

4

-

-

... More
S&F in renewal of stay assembly complete comprising & including of galvlanised steel stay wire stranded 7/4 mm galvanised steel stay bow 400x20mm stay rod, 1800 mm long, 20 mm dia with nuts, bolts and washers, steel plate 300x300x6.0 mm two Nos thimble, including loop type insulator size 90 x 140 mm clearance hole of 20 mm dia including necessary excavation, earth work in any type of soil, PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation, disposal of surplus soil upto a distance of 50 m and fixed to stay clamp, complete all as specified in electrical plate No 1 of MES SSR part I and directed. (Stay clamps shall be measured separately in MS Work).

2

-

-

... More
Supply, straining, streching and fixing ACSR conductor on HT/LT poles or on existing poles including binding and jointing to conductor/ insulator with and including suitable size of copper binding wire or aluminium tape and testing & including dismantling of old u/s ACSR conductors from the poles, complete all as specified and directed.

0.5

-

-

... More
S&F in renewal of galvanised steel wire 4mm dia , cradle guards, hexagonal/ rectangular fabricated of galvanised steel wire 3.15mm dia including binding wire aluminium cradle guard, complete all as specified and directed.

0.25

-

-

... More
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.3 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron including 15 mm bore light grade GI tubing for protection of earth wire, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling of old u/s earthing complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 3 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth wire upto 7.5m.

7

-

-

... More
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.3 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth strip of 25x4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 50 mm bore light grade GI tubing for protection of earth strip, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI earth strip of 32x6 mm size for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling of old u/s earthing complete all as specified and directed.complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 3 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth lead strip upto 7.5 m.

10

-

-

... More
S&F in renewal of earth continuity conductor or main earthing lead 32x6mm galvanised iron or steel strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and directed.

40

-

-

... More
S&F in renewal of 50 mm bore steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.

60

-

-

... More
S&F in renewal of 80 mm bore steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.

72

-

-

... More
S&F in renewal of 100 mm bore steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.

30

-

-

... More
Supply, installing, testing and commissioning of Air-break, gang operated, triple pole switch, outdoor, vertical mounting type (ISI marked), mechanically operated, mounted on insulators 15 nos including 200 amp rating complete with (DO Fuse unit) fuse mounts, fuse carriers and HT fuse elements and frame work with operating mechanism worked from ground level, with locking arrnagments including Godrej pattern 65mm pad locks with two keys, suitable for HT 11 KV, 50 Hz AC supply & including necessary electric connections and taking down old unserviceable GOD complete all as specified and directed.

4

-

-

... More
Supply, installing, testing and commissioning of Air-break, gang operated, triple pole switch, outdoor, vertical mounting type (ISI marked), mechanically operated, mounted on insulators 15 nos including 400 amp rating complete with (DO Fuse unit) fuse mounts, fuse carriers and HT fuse elements and frame work with operating mechanism worked from ground level, with locking arrnagments including Godrej pattern 65mm pad locks with two keys, complete suitable for HT 11 KV, 50 Hz AC supply including necessary electric connections and taking down old unserviceable GOD complete all as specified and directed.

5

-

-

... More
Supplying, laying, jointing, testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed grade (ISI marked), laid in trenches / ducts / encased in GI pipe / fixed to pole/wall with necessary angle iron support, clamp, nut , bolts etc and including taking down of old unserviceable existing UG cables complete all as specified and directed for following cross sectional areas of cables :- Notes for Srl item Nos. 23.00 & 23.10 :- (i) Excavation, earth work, sand cushioning, cable protection cover & GI pipes shall be measured and paid for separately under respective items of BOQ. (ii) Quoated rate shall be deemed to be inclusive of connecting up with control gear including cable glands and cable lugs. Cross Sectional area of cable 95 Sq mm 3 core

225

-

-

... More
Cross Sectional area of cable 185 Sq mm 3 core

225

-

-

... More
Supply, transporting, erection and fixing steel tubular swaged pole, 11.00 metres long, type 410 SP-55, complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:3:6 type C2, using 40 mm graded stone aggregate and PCC 1:2:4 type B1, using 20 mm graded stone aggregate as in coping to the pole, disposal of surplus soil to a distance not exceeding 50 m, painting the pole with two coats of aluminium paint over one coat of red oxide primer including 3 nos band/straps with red post office box colour (300mm wide each) synthetic enamelled paint at a distance 300mm from plinth block and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete & including taking down existing old unserviceable poles and complete all as specified and directed.

4

-

-

... More
M&L for painting the external exposed surfaces of steel tubular swaged/rail poles of 11 metres long alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground and pasting 100 mm wide reflective red strickers in 3 lines around the pole, complete all as specified and directed.

20

-

-

... More
M&L for painting the external exposed surfaces of 2 pole structures of steel tubular swaged poles of 11 metres long alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground and pasting radium red strickers/paint with 3 strips of width min 10 cm around the pole complete all as directed.

7

-

-

... More
M&L for painting the external exposed surfaces of 4 pole structures of steel tubular swaged poles of 11 metres long alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground and pasting radium red strickers/paint with 3 strips of width min 10 cm around the pole complete all as directed.

7

-

-

... More
M&L for painting the cross arms, bracket and connected accessories with one coat of aluminium paint of PCC pole including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground complete all as directed.

10

-

-

... More
M & L for cutting of bushes and cleaning the area around the sub station & surface dressing n exc 15 cm deep & including two pole/four pole structures premises at northern & central sector and trimming the trees, complete all as specified and directed.

2500

-

-

... More
M & L for trimming /cutting of tree branches to provide proper clearance around existing HT/LT over head line with clearance of 3 mtr on both the sides from the centre of OH line all as per technical requirement & including removing of cut tree branches from site and depositing at places complete all as specified and directed.

150

-

-

... More
Restretching of existing aluminium conductor steel reinforced (ACSR) straining properly on insulators and binding with aluminium tape/binding wire connectors, PG clamps, jumpers etc, complete all as specified and directed for any size of ACSR conductor. Note:- Length of three conductors shall be treated as one unit. no extra payment shall be given to contractor on this account.

530

-

-

... More
Supply and fixing in renewal of HT cable/route indicator cast iron of suitable size along HT cable trench including planting in ground with proper PCC complete all as specified and directed. Note :- Cost of pcc shall be included in the rate quoted.

50

-

-

... More
Supply and fixing in renewal of danger notice plate of 1.5 mm thick mild steel sheet vitreous enanelled white of size 20 x25 cm with figures letters and conventional skull bones in signal red colour and fixed with mild steeel clamps made of flat iron nuts bolts and washers etc for HT poles with voltage and danger indicated in hindi and english and local vernacular complete all as specified and directed.

10

-

-

... More
M & L for horizental drilling under road/pavement hard standing with trenchless technology using machine 0.4 mpa working pressure for laying pipe line of size 80 mm bore complete all as specified and directed. Note: Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine.

45

-

-

... More
M & L for horizental drilling under road/pavement hard standing with trenchless technology using machine 0.4 mpa working pressure for laying pipe line of size 100 mm bore complete all as specified and directed. Note: Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine.

45

-

-

... More
M & L in renewal for anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.

0.4

-

-

... More
M & L in renewal of HT jumpering from HT 4/2 pole structure to bus bar to GOD 3 Nos with HT cable 95 sqmm not less than 3 mtr complete including connector and lugs of suitable size with provision of Nuts & bolts washer etc complete all as specified and directed.

22

-

-

... More
M & L for repairing/overhauling of Air break switch and DO fuse unit up to 400 Amps capacity 11 KV triple pole Mechanically operted mounted on insulators and steel frame installed vertically/horizontally by oiling and greasing of mechanical moving parts smoothing and polshing of electric contacts and applying conducting jelly to contact and replacement of broken/worn out compenents ( if required) including testing after repair complete all as directed. Note :- Cost of replacement of following worn out components /parts/insulators etc (if required) shall be included in the rate quoted. Bidders may quote accordingly. (a) Female contact or fixed contact of capacity up to 400 Amps, 11 KV heavy duty of gigh conductive metal (b) Male contact or moving contact of capacity up to 400 Amps, 11 KV heavy duty of high conductive metal (c ) Tinned copper flexible jumper up to 400 Amp. (d) Fixed top and bottom contact assembly 11 KV 400 Amp for DO fuse unit (e) Fiber glass tube with metallic fittings both ends suitable for DO fuse 11 KV.

8

-

-

... More
M & L for disconnecting all HT/LT connection of transformer, lifting it from its foundation/ structure using fork lift/crane carefully, refixing it to plateform making all HT/LT connetions and charging the transformer to restore electric supply complete all as specified and as directed. Note :- (i) Any damage during shifting or lifting of transfarmer will be responsibility of contractor and contractor will be liable to repair the same at his own cost. (ii) Lowering and lifting of transformer shall be treated as single job.

2

-

-

... More
M & L for Servicing of HT 11 KV VCBs including raking out of Breaker, lubrication /greasing of the mechanical parts including healthy check, cleanign of CT, caliberation after servicing reconnection in all respect along with replacement of unserviceable relays, levers, LED indicators, control wiring, insulators etc (if required), all as per existing arrangement and restore the supply complete all as specified and as directed. Note :- Cost of unsv materials replaced shall be deemed to be included in the rate quoted. No extra claim shall be accepted by dept on this account. Bidders may quote accordingly.

7

-

-

... More
M & L for hiring of cable fault locator machine for HT cables working voltage 11 KV to find out the fault in underground trench at different location up to 500 RM after locate fault filling the straight through joint and charging the cable and jointing the cable on both side in RMU/VCB/HT bus bar chamber or over head line all as directed. Note :- (i) Complaint shall be intimated to contractor on phone between 8 am to 10 pm and will be attended by contractor within 12 hrs, failing which a penalty of Rs. 1500 per day shall be imposed on contractor. (ii) Cost of joints shall be measured and paid in respective item of Schedule. (iii) Machine hiring count shall be measured and paid as per number of arrivals of machine not as per no. of faults located in a single arrival.

7

-

-

... More
M & L for Servicing of 11 KV 3 phase 50Hz 3 wire 630 Amp breaking capacity SF6 Ring Main Unit by cleaning and lubricating mechanical parts and checking functioning of springs levers on/off position after proper shut down of electric supply along with replacement of unserviceable relays, levers, LED indicators, control wiring, insulator etc (if required) and restore the supply after complete servicing complete all as specified and as directed. Note :- Cost of unsv materials replaced shall be deemed to be included in the rate quoted. No extra claim shall be accepted by dept on this account. Bidders may quote accordingly.

4

-

-

... More
M&L for construction of plateform of size 2500 x 2500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primer and including demolition of old u/s transformer foundation complete all as specified and as directed.

2

-

-

... More
M & L in renewal of fabricating, supplying, installing, testing & commisioning of outdoor type CPRI approved factory made HT 11 KV feeder pillar box of size not less than 150cmx90cmx75cm with top cover 5 cm projected alaround made with thcik 3 mm CRCA sheet, weather proof, vermin proof with double door, handle with locking arrangement, powder coated including PVC insulated copper bus bar 3 nos of size 100cmx5cmx0.5cm & mounted on HT 11 KV insulators 9 nos (theree noper bus bar) insulator should be mounted on MS sheet with thickness 3 mm made in shape including weather proof painting. The feeder pillar box shall be mounted on MS angle of MS angle of size 60x60x6 mm duly covered with MS SHEET 3 MM thick on all sides about 1.5 m from the bottom of FPB & all sides removable type including two coat of synthetic enamel paint over a coat of red oxide primer including necessary excavation earth work in any type of soil, PCC block (1:3:6) incuding writing name of feeder on FPB and taking down HT joint from pole, complete all as specified and directed.

2

-

-

... More
S&F in renewal of Epoxy/porcelain or as suitable at site insulator suitable for VCB (indoor)/HT bus bar box 11 KV pressure range with nut bolt washer complete all as specified and directed.

12

-

-

... More
M & L in renewal for lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp Suitable for 11000 volts complete all as specified and directed.

1

-

-

... More
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable & including excavation in any type of soil/strata, taking out cable & making disturbed surface after relaying the cable making joints suitable for aluminium conductor of following size complete all as specified and directed :- Note:- Unserviceable joint shall be replaced within 24 Hrs after intimation of failure & documentary proof kept in record duly signed by the Enginner-in-Charge for the same. A penalty of Rs. 1500 per day shall be imposed on contractor, if not attended timely.

-

-

-

... More
95 Sqmm

5

-

-

... More
120 Sqmm to 185 Sqmm

6

-

-

... More
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable & including excavation in any type of soil/strata, taking out cable & making disturbed surface after relaying the cable making joints suitable for aluminium conductor of following size complete all as specified and directed :- Note:- Unserviceable joint shall be replaced within 24 Hrs after intimation of failure & documentary proof kept in record duly signed by the Enginner-in-Charge for the same. A penalty of Rs. 1500 per day shall be imposed on contractor, if not attended timely.

-

-

-

... More
95 Sqmm

6

-

-

... More
120 Sqmm to 185 Sqmm

6

-

-

... More
Laying/ fixing, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene) insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles with proper size saddles and clamp and including taking down of old unserviceable existing UG cables complete all as specified and directed for following cross sectional areas of cables :- Notes for Srl item Nos. 49.00 to 49.20 :- (a) Excavation & earth work , GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respectiv items of the schedule. (b) Cable shall be issued under Schedule 'B' free for fixing/laying. (c) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions. (d) Quoated rate shall be deemed to be inclusive of connecting up with control gear including cable glands and cable lugs. Cross Sectional area of cable 50 Sq mm 3.5 core

100

-

-

... More
Cross Sectional area of cable 25 Sq mm 4 core

285

-

-

... More
Cross Sectional area of cable 16 Sq mm 4 core

200

-

-

... More
S & F in renewal for electronic digital type Ampere meter, 0-150 Amp with selector switch upto 150 Amp of any size complete all as specified and directed.

8

-

-

... More
S & F in renewal for electronic digital type Voltmeter, 0-500 Volt with selector switch upto 500V of any size complete all as specified and directed.

8

-

-

... More
S&F in renewal of earth continuity conductor or main earthing lead 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and directed.

20

-

-

... More
S&F in renewal of galvanised iron earth strip of size 25x4 mm, fixed to wall or pole, complete all as specified and directed.

30

-

-

... More
Supplying, laying, jointing, testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade (ISI marked), laid in trenches / ducts / encased in GI pipe / fixed to pole/wall with necessary angle iron support, clamp, nut , bolts etc and including taking down of old unserviceable existing UG cables complete all as specified and directed for following cross sectional areas of cables :- Notes for Srl item Nos. 54.10 to 54.40 :- (i) Excavation, earth work, sand cushioning, cable protection cover & GI pipes shall be measured and paid for separately under respective items of BOQ. (ii) Quoated rate shall be deemed to be inclusive of connecting up with control gear including cable glands and cable lugs. Cross Sectional area of cable 16 Sq mm 4 core

250

-

-

... More
Cross Sectional area of cable 25 Sq mm 4 core

250

-

-

... More
Cross Sectional area of cable 70 Sq mm 3.5 core

200

-

-

... More
Cross Sectional area of cable 95 Sq mm 3.5 core

30

-

-

... More
Cross Sectional area of cable 150 Sq mm 3.5 core

20

-

-

... More
Supply, transporting, erection and fixing steel tubular swaged pole, 9.00 metres long, type 410 SP-31, complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:3:6 type C2, using 40 mm graded stone aggregate and PCC 1:2:4 type B1, using 20 mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m, painting the pole with two coats of aluminium paint over one coat of red oxide primer including 3 nos band/straps with red post office box colour (300mm wide each) synthetic enamelled paint at a distance 300mm from plinth block and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete & including taking down existing old unserviceable poles and complete all as specified and directed. Note:- Excavation and earth work, PCC etc deemed to be included in the quotated rate.

16

-

-

... More
M&L for painting the external exposed surfaces of steel tubular swaged/rail poles of 9.0 metres long alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the numbering /details of the pole in white letters on black back ground and pasting 100 mm wide reflective red strickers in 3 lines around the pole, complete all as specified and directed.

120

-

-

... More
S&F in renewal of aluminium lugs, properly crimping and taping different colours, complete all as specified and dircted for the following size of cables: - 185 Sqmm

2

-

-

... More
150 Sqmm

4

-

-

... More
120 Sqmm

4

-

-

... More
95 Sqmm

4

-

-

... More
50 Sqmm

8

-

-

... More
35 Sqmm

6

-

-

... More
25 Sqmm

20

-

-

... More
16 Sqmm

20

-

-

... More
S & F in renewal for MCCB, four pole, 415 Volts, 250 Amp, ultimate breaking capacity 36 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.

2

-

-

... More
S & F in renewal for MCCB, four pole, 415 Volts, 160 Amp, ultimate breaking capacity 25 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.

2

-

-

... More
S & F in renewal for MCCB, four pole, 415 Volts, 100 Amp, ultimate breaking capacity 25 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.

1

-

-

... More
S & F in renewal for MCCB, four pole, 415 Volts, 63 Amp, ultimate breaking capacity 10 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.

1

-

-

... More
Supply only electrical insulating tape roll of length 25 metre and width 20 mm having high performance strength and good adhesive characteristics, complete all as directed.

250

-

-

... More
S&F in renewal of bus bar chamber, 4 pole, factory made using CRCA sheet of 3.15 mm thickness and epoxy powder coated with locking arrangements, comprising of 4 Nos aluminium strip bus bars of adequate length, air insulated and PVC sheathed capacity 250 Amps rating with colour coding and mounted on porcelain insulators housed in a box of size 800x600x300 mm, including provision of fixing incoming MCCB for addition & connection with LT cable with appropriate lugs and including angle iron stand of appropriate size complete all as specified and directed. Note :- Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area.

5

-

-

... More
S&F in renewal of bus bar chamber, 4 pole, factory made using CRCA sheet of 3.15 mm thickness and epoxy powder coated with locking arrangements, comprising of 4 Nos aluminium strip bus bars of adequate length, air insulated and PVC sheathed capacity 400 Amps rating with colour coding and mounted on porcelain insulators housed in a box of size 800x600x300 mm, including provision of fixing incoming MCCB for addition & connection with LT cable with appropriate lugs and including angle iron stand of appropriate size complete all as specified and directed. Note :- Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area.

5

-

-

... More
S&F in renewal of bus bar chamber, 4 pole, factory made using CRCA sheet of 3.15 mm thickness and epoxy powder coated with locking arrangements, comprising of 4 Nos aluminium strip bus bars of adequate length, air insulated and PVC sheathed capacity 500 Amps rating with colour coding and mounted on porcelain insulators housed in a box of size 800x600x300 mm, including provision of fixing incoming MCCB for addition & connection with LT cable with appropriate lugs and including angle iron stand of appropriate size complete all as specified and directed. Note :- Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area.

4

-

-

... More
S & F in renewal of service wire of size 6 Sqmm 2 core of aluminium conductor PVC sheathed, confirming to latest IS/IEC complete all as specified and directed.

90

-

-

... More
S & F in renewal of service wire of size 4 Sqmm 2 core of aluminium conductor PVC sheathed,confirming to latest IS/IEC complete all as specified and directed.

90

-

-

... More
Disconnection of power supply from existing LT Panel of any type, disconnection of earth strips, cutting of the foundation angles/channels, removing of the panel from the site, including MS iron form work for raising the height of the panel upto the height as directed by the Engineer-in-Charge, including painting of LT panel complete with inner & outer with two coats of synthetic enamelled paint using spray painting machine, re-installation of panel, including repair to foundation of panel, restoration of power supply, including necessary excavation & earth work required for taking out & re-fixing the incoming and out going cables etc, complete all specified and directed. Note :- The MS form work deemed to be included in the quoted rate.

5

-

-

... More
M & L for repair to existing LT Panel of any type/ size, with cutting necessary worn out portion of MS sheet, angle iron and providing MS sheet of 2mm thick for renewal of rusted/broken LT panel door, MS angle iron of existing size and hinges to broken door, fixed with electric arc welding, providing external locking arrangement after taking proper electric shutdown, including rewiring by copper conductor control cables of suitable size, renewal of burnt out aluminium lugs and fixing with new lugs, nuts bolts etc, including painting of LT panel complete with inner & outer with two coats of synthetic enamelled paint using spray painting machine complete all specified and directed. Note :- Material such as MS sheet, angle iron, hinges deemed to be included in the quoted rate.

5

-

-

... More
Disconnection of electric connection from existing LT Panel/LT feeder pillars panel of any size, dressing of cable ends including repair of body of LT panel, repair/welding work of gates, hinges of the door including rewiring by copper conductor control cables of suitable size, renewal of burnt out aluminium lugs and fixing with new lugs, nuts bolts etc, including painting of LT panel complete with inner & outer with two coats of synthetic enamelled paint using spray painting machine & necessary welding work if required & including necessary excavation & earth work required for taking out & re-fixing the incoming and out going cables etc, complete all specified and directed.

15

-

-

... More
M&L for straight through jointing kits heat shrikable type LT UG XLPE cable heavy duty armoured sheathed & including excavation in any type of soil/strata, taking out cable & making disturbed surface after relaying the cable making joints suitable for aluminium conductor of following size complete all as specified and directed :-

-

-

-

... More
10 Sqmm to 16 Sqmm 4 core

10

-

-

... More
25 Sqmm to 50 Sqmm 3.5 core

10

-

-

... More
70 Sqmm to 120 Sqmm 3.5 core

2

-

-

... More
150 Sqmm to 185 Sqmm 3.5 core

2

-

-

... More
Supplying, installation, commissioning and testing (including CPRI type test certified) of outdoor type, weather proof, factory made LT feeder pillar box (Kiosk) of appropriate size (OR as per Indian Electricity Rules), protection class IP-65 made of 3.15 mm thick CRCA sheet duly powder coated, having double door opening (front & rear) with locking arrangement, provision of entry & exit CP brass glands for cables, having bus bar chamber with 4 No heat shrink insulated aluminium bus bar of 600 Ampere capacity and including all connection with aluminium busbar strip, provided with danger notice plate with skull & bone sign, including making all electrical incoming and outgoing electrical cable connection with new lugs, gland to be provided at cable entries and including 40x40x6mm thick angle iron frame work at the base of panel only for grouting purpose & necessary cement concrete 1:2:4 type B1 for grouting of panel stand and connecting the panel with existing earthing and including dismantling of old u/s existing panel comprising of the following: - (A) INCOMING: - (a) Aluminium bus bar of rating 600 Amps for four pole - 01 Set (b) MCCB, 4 pole, 415 volts, 50 Hz, AC, 400 Amp rating with rupturing capacity 36 KA microprocessor control type– 01 No. (c) Electronic digital type Ampere meter, 0-500 Amp with selector switch upto 500 Amp & 3 Nos CT's ration 250/5 copper wound, square 96x96 mm - 01 No. (d) Electronic digital type Volt meter, 0-500 volts, square 96x96 mm with selector switch - 01 No. (e) Phase indicator LED type indicating lamp (RYB) with copper control wiring - 01 set of three. (B) OUTGOING :- (a) MCCB, 4 pole, 415 volts, 50 Hz, AC, 160 Amp rating with rupturing capacity 25 KA adjustable thermal & adjustable magnetic settings mounted on din rail – 02 Nos. (b) MCCB, 4 pole, 415 volts, 50 Hz, AC, 100 Amp rating with rupturing capacity 25 KA adjustable thermal & adjustable magnetic settings – 01 No. (c) MCCB, 4 pole, 415 volts, 50 Hz, AC, 63 Amp rating with rupturing capacity 16 KA adjustable thermal & adjustable magnetic settings – 03 Nos. Note :- (i) Necessary approval of drawings of LT feeder Pillars shall be approved by GE before placing order by the Contractor. (ii) Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area. (iii) Cost of above aspects is deemed to be included in quoted rates.

1

-

-

... More
Supplying, installation, commissioning and testing (including CPRI type test certified) of outdoor type, weather proof, factory made LT feeder pillar box (Kiosk) of appropriate size (OR as per Indian Electricity Rules), protection class IP-65 made of 3.15 mm thick CRCA sheet duly powder coated, having double door opening (front & rear) with locking arrangement, provision of entry & exit CP brass glands for cables, having bus bar chamber with 4 No heat shrink insulated aluminium bus bar of 800 Ampere capacity and including all connection with aluminium busbar strip, provided with danger notice plate with skull & bone sign, including making all electrical incoming and outgoing electrical cable connection with new lugs, gland to be provided at cable entries and including 40x40x6mm thick angle iron frame work at the base of panel only for grouting purpose & necessary cement concrete 1:2:4 type B1 for grouting of panel stand and connecting the panel with existing earthing and including dismantling of old u/s existing panel comprising of the following: - (A) INCOMING: - (a) Aluminium bus bar of rating 800 Amps for four pole - 01 Set (b) MCCB, 4 pole, 415 volts, 50 Hz, AC, 630 Amp rating with rupturing capacity 50 KA microprocessor control type– 01 No. (c) Electronic digital type Ampere meter, 0-500 Amp with selector switch upto 500 Amp & 3 Nos CT's ration 250/5 copper wound, square 96x96 mm - 01 No. (d) Electronic digital type Volt meter, 0-500 volts, square 96x96 mm with selector switch - 01 No. (e) Phase indicator LED type indicating lamp (RYB) with copper control wiring - 01 set of three. (B) OUTGOING :- (a) MCCB, 4 pole, 415 volts, 50 Hz, AC, 250 Amp rating with rupturing capacity 36 KA adjustable thermal & adjustable magnetic settings mounted on din rail – 02 Nos. (b) MCCB, 4 pole, 415 volts, 50 Hz, AC, 100 Amp rating with rupturing capacity 25 KA adjustable thermal & adjustable magnetic settings – 02 Nos. (c) MCCB, 4 pole, 415 volts, 50 Hz, AC, 63 Amp rating with rupturing capacity 16 KA adjustable thermal & adjustable magnetic settings – 02 Nos. (b) MCB, 415 volts, AC, three pole & neutral, 32 Amp, breaking capacity 10 KA – 02 Nos. Note :- (i) Necessary approval of drawings of LT feeder Pillars shall be approved by GE before placing order by the Contractor. (ii) Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area. (iii) Cost of above aspects is deemed to be included in quoted rates.

1

-

-

... More
Supplying, installation, commissioning and testing (including CPRI type test certified) of outdoor type, weather proof, factory made LT feeder pillar box (Kiosk) of appropriate size (OR as per Indian Electricity Rules), protection class IP-65 made of 3.15 mm thick CRCA sheet duly powder coated, having double door opening (front & rear) with locking arrangement, provision of entry & exit CP brass glands for cables, having bus bar chamber with 4 No heat shrink insulated aluminium bus bar of 400 Ampere capacity and including all connection with aluminium busbar strip, provided with danger notice plate with skull & bone sign, including making all electrical incoming and outgoing electrical cable connection with new lugs, gland to be provided at cable entries and including 40x40x6mm thick angle iron frame work at the base of panel only for grouting purpose & necessary cement concrete 1:2:4 type B1 for grouting of panel stand and connecting the panel with existing earthing and including dismantling of old u/s existing panel comprising of the following: - (A) INCOMING: - (a) Aluminium bus bar of rating 400 Amps for four pole - 01 Set (b) MCCB, 4 pole, 415 volts, 50 Hz, AC, 160 Amp rating with rupturing capacity 25 KA microprocessor control type– 01 No. (c) Electronic digital type Ampere meter, 0-500 Amp with selector switch upto 500 Amp & 3 Nos CT's ration 250/5 copper wound, square 96x96 mm - 01 No. (d) Electronic digital type Volt meter, 0-500 volts, square 96x96 mm with selector switch - 01 No. (e) Phase indicator LED type indicating lamp (RYB) with copper control wiring - 01 set of three. (B) OUTGOING :- (a) MCCB, 4 pole, 415 volts, 50 Hz, AC, 63 Amp rating with rupturing capacity 16 KA adjustable thermal & adjustable magnetic settings mounted on din rail – 04 Nos. (b) MCB, 415 volts, AC, three pole & neutral, 32 Amp, breaking capacity 10 KA – 02 Nos. Note :- (i) Necessary approval of drawings of LT feeder Pillars shall be approved by GE before placing order by the Contractor. (ii) Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area. (iii) Cost of above aspects is deemed to be included in quoted rates.

1

-

-

... More
S & F for renewal of capacitor bank of following size & confirming to latest IS/IEC complete all as specified and directed :- Capacitor of 10 KV Ar rating

5

-

-

... More
Capacitor of 15 KV Ar rating

4

-

-

... More
Capacitor of 20 KV Ar rating

2

-

-

... More
Capacitor of 30 KV Ar rating

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.