If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 61,180Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_MES_195044_1Bid Award Id
ViewTender No
8784/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M & L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection complete including taking down old unserviceable bricks all as specified & directed.
16
-
-
... More
M & L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed.
Note :- Thickness after punning shall be considered for payment.
136
-
-
... More
Taking up or down steel water tubing and connections of 40/50mm bore, fixed in walls, ceiling, floors, trenches etc. all as directed.
Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
90
-
-
... More
Taking up or down steel water tubing and connections of 80mm bore, fixed in walls, ceiling, floors, trenches etc. all as directed.
Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
12
-
-
... More
M&L Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
12
-
-
... More
M&L Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
60
-
-
... More
M&L Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
30
-
-
... More
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule complete all as specified.
10
-
-
... More
M&L PCC 1:3:6 type C-1, using 20mm graded stone aggregate as in coping benching/pedestal of poles etc including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished rough complete all as specified.
2
-
-
... More
M&L PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation of stay assembly & poles and similar works complete all as specified.
8
-
-
... More
Dismantling & taking down old unserviceable aluminium conductor steel reinforced (ACSR) from overhead lines on LT Poles of any size complete all as specified and directed.
8
-
-
... More
S&F aluminium conductor steel reinforced (ACSR) of any size including jointing with and including aluminium binding wire 2 mm dia and stretching complete on LT poles all as specified and as directed. Notes :- (i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I.
(ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes etc which shall not be included in the weight of conductors for payment.
(iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc.
(iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code.
8
-
-
... More
Dismatling & Taking down old unserviceable cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts.
10
-
-
... More
S&F cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts in any shape or size etc, complete, all as specified. Note :- Size, section and shape of steel sections shall be as directed.
10
-
-
... More
Supply and fixing pre-stressed concrete pole 09 meter long of cross section 102mm x 172mm at the top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1978 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and marking pole number complete including dismantling and taking down old unserviceable pre-stressed concrete pole 09 metre long all as specified & as directed.
Note :- Excavation & earthwork, PCC in foundation & coping shall be measured and paid for separately.
10
-
-
... More
S&F stay assembly complete with accessories as shown on electrical plate No 1 of SSR Part-I with 16 mm dia 1.80 mm long stay rod, 300mm x 300mm x 6mm thick stay plate, complete including taking down old unserviceable stay assembly all as specified & as directed.
Note:- All excavation & earth work and foundation concrete shall be measured and paid for separately under relevant items of this schedule.
15
-
-
... More
S&F GI continuous earth wire or guard/cradle made to shape of 3.15mm dia including Galvanized mild steel binding wire 1.63mm dia complete including dismantling existing unserviceable continuous GI earth wire/guard/cradles of any size all as specified & as directed. Note :- Galvanized wire shall be measured & paid for under this item and clamps, eye hooks where provided shall be measured and paid for separately
2
-
-
... More
S&F galvanized steel stranded stay wire of size 7/3.15mm or 7/4mm for stay assembly.
0.5
-
-
... More
Restraining/tightening of existing LT over head ACSR conductor of any size upto permissible sag in between existing span including GI earth wire, clamps, cradles etc. including new 2mm dia aluminum binding wire complete all as specified. Note :- The length of each conductor shall be measured & paid for. The rate quoted shall be for one conductor.
10
-
-
... More
M & L for cutting/trimming the tree branches 3 mtr adjacent to the LT OH lines/street light feeder on bothe sides and removing the the same to out side and disposing same complete all as direcetd (per span distance 30-40 mtrs)
1000
-
-
... More
M&L for painting to PCC LT pole 9 metre long of any size with two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.2 metre height from top of PCC coping/pedestal and applying two coats of aluminum paint over cross arms, brackets, bracings, clamps, hooks etc and marking pole numbers including preparation of old surfaces for painting complete all as specified.
320
-
-
... More
M&L for painting to steel tubular LT pole 9 metre long of any size with two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.2 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint to remaining portion of steel pole, over cross arms, brackets, bracings, clamps, hooks etc and marking pole numbers including preparation of old surfaces for painting complete all as specified.
180
-
-
... More
S&F in repairs Loop type insulator, vitreous porcelain, white, brown or green with dimensions 90mm x 140 mm and clearance hole 25.5 mm, ISI marked complete all as specified.
10
-
-
... More
S&F in repairs pin type insulator porcelain vitreous, white, brown or green for working pressure 1100 volts, 100mm height and 65mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut complete all as specified.
150
-
-
... More
S&F in repairs shackle type insulator porcelain vitreous, white, brown or green, working pressure 1100 Volts, 90mm dia and 75mm height including galvanized mild steel straps of section 31mm x 3mm with 12mm dia insulator bolts, washers and nuts complete all as specified.
60
-
-
... More
S&F in repairs MCCB, 4 Pole, 400 Amps rating, rupturing capacity 35 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type between 70-100% and making connections all as specified.
4
-
-
... More
S&F in repairs MCCB, 4 Pole, 250 Amps rating, rupturing capacity 35 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type and making connections all as specified.
5
-
-
... More
S&F in repairs MCCB, 4 Pole, 200 Amps rating, rupturing capacity 35 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type and making connections all as specified.
6
-
-
... More
S&F in repairs MCCB, 4 Pole, 160 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type and making connections all as specified.
3
-
-
... More
S&F in repairs MCCB, 4 Pole, 160 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type and making connections all as specified.
7
-
-
... More
S&F in repairs MCCB, 4 Pole, 63 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type and making connections all as specified.
8
-
-
... More
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 185 sqmm 3.5core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified including dismantling & taking out old unserviceable cable complete all as specified and directed.
Note :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
120
-
-
... More
All as per serial item No 35.00 here-in-before but of cross sec area 150 sqmm 3½ core.
200
-
-
... More
All as per serial item No 35.00 here-in-before but of cross sec area 95 sqmm 3½ core.
200
-
-
... More
All as per serial item No 35.00 here-in-before but of cross sec area 70 sqmm 3½ core.
250
-
-
... More
All as per serial item No 35.00 here-in-before but of cross sec area 35 sqmm 3½ core.
400
-
-
... More
All as per serial item No 35.00 here-in-before but of cross sec area 25 sqmm 4 core.
150
-
-
... More
All as per serial item No 35.00 here-in-before but of cross sec area 16 sqmm 2 core.
400
-
-
... More
All as per serial item No 35.00 here-in-before but of cross sec area 10 sqmm 2 core.
600
-
-
... More
S&F in repairs on load change over switch in sheet steel enclosure with front handle, 100 Amps, 4 pole, 415 Volts, 50 Hz complete all as specified & as directed.
2
-
-
... More
Disconnecting and taking down XLPE insulated LT electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 120 to 95 sqmm 3½ core from LT Pole and cutting the burnt portion/un-insulated portion of LT cable and making the end of LT cable suitable for re-connection and re-connecting the LT cable on LT Pole and connecting with over head conductor including taking out the suitable length of cable required for re-connection from loop including necessary excavation complete all as directed.
25
-
-
... More
All as per serial item No 40.00 here-in-before but cable of size 50 to 25 sqmm 3½ core.
45
-
-
... More
All as per serial item No 40.00 here-in-before but cable of size 16 to 10 sqmm 3½ core.
65
-
-
... More
M&L for disconnecting, lifting, loading and transportation of unserviceable transformer indoor/outdoor type 11000/433 Volts of capacity 100 KVA from site to workshop for repair/rewinding and repair to the transformer by dismantling the top cover and removing unserviceable tap changer and draining out entire unserviceable transformer oil and removing all unserviceable parts such as HT/LT side bushings, nuts, bolts, washers, gasket set etc and removing all burnt LT/HT side coil from the core, rewinding the LT and HT side core complete with same size of copper wire in HT side
(description contd. in serial No. 47.01)
1
-
-
... More
(description of serial No. 47.00 contd...) and copper strip from LT side with suitable insulating materials, nuts, bolts, washers, gasket set etc, heating the new transformer winding in special heat chamber for demoisturising of LT/HT coil, connecting the LT/HT coils, filling the fresh transformer oil, re-assembling the transformer, transporting/shifting back the transformer at site after repairs, re-commissioning & testing, including applying two coats of synthetic enamel paint of approved tint after preparation of all external surfaces of transformer, complete, all as specified and directed by Engineer-in-Charge.
-
-
-
... More
Notes for serial item No. 47.00 (including 47.01) (i) The quoted rates shall deemed to include for the transportation, T&P, Labours from site to workshop and workshop to back at site after repairs, cost of gasket set, nuts, bolts, washers, insulating material, copper wire for delta connection etc. Dielectric strength of Transformer oil shall be tested at site in presence of Engineer-in-charge.
(ii) All other spares such as tap changer, copper wire & copper strip for rewinding, HT/LT side bushing, transformer oil & air breather assembly with silica gel shall be measured and paid for separately as “Supply only” under respective items of this Schedule.
-
-
-
... More
All as per serial item No. 47.00 (including serial item No. 47.01 & 47.02) here-in-before but transformer of capacity 160 KVA.
1
-
-
... More
All as per serial item No. 47.00 (including serial item No. 47.01 & 47.02) here-in-before but transformer of capacity 250 KVA.
1
-
-
... More
Supply only the following spares/items for repair to transformers under serial item No. 47.00 including 47.01 & 47.02, 48.00 and 49.00 here-in-before :-
-
-
-
... More
Copper winding wire / Copper strip of required size.
600
-
-
... More
Transformer oil having di-electric strength 40 to 60 KV
Make : - Savita / Power Link / Servo
850
-
-
... More
HT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal etc for transformer of capacity 100 KVA.
3
-
-
... More
HT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal etc for transformer of capacity 160 KVA.
3
-
-
... More
HT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal etc for transformer of capacity 250 KVA.
3
-
-
... More
LT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal etc for transformer of capacity 100 KVA.
3
-
-
... More
LT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal etc for transformer of capacity 160 KVA.
3
-
-
... More
LT bushing porcelain with copper stud, nuts, bolts, washers, gasket, oil seal etc for transformer of capacity 250 KVA.
3
-
-
... More
Tap changer assembly complete with operating handle suitable for transformer of capacity 100 KVA.
1
-
-
... More
Tap changer assembly complete with operating handle suitable for transformer of capacity 160 KVA.
1
-
-
... More
Tap changer assembly complete with operating handle suitable for transformer of capacity 250 KVA.
1
-
-
... More
Air breather assembly filled with silica gel suitable for transformer of capacity 100 KVA.
1
-
-
... More
Air breather assembly filled with silica gel suitable for transformer of capacity 160 KVA.
1
-
-
... More
Air breather assembly filled with silica gel suitable for transformer of capacity 250 KVA.
1
-
-
... More
M&L for earthing with and including galvanized MS earth plate electrode of size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5m below ground level as shown in electrical plate No 3 of SSR Part I, the earth plate surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all sides, excavation & earth work in any type of soil and removal of surplus soil upto 50m including galvanized mild steel strip 32mm x 6mm as earth lead, welding at top of electrode and other end of strip connected to test point with two Nos nuts bolts, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 3.00 metre above ground level with and including (description contd. in serial No. 51.01)
20
-
-
... More
(description of serial No. 51.00 contd...) 25x3mm FI clamps, bolts, nuts and washers, PCC chamber (1:3:6) type C1, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering, 75 mm thick RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking down old unserviceable earthing all as specified & as directed.
Note : (i) Item includes cost of 7.5m earth lead strip.
(ii) Earthing shall be provided as per IS-3043 and relevant clauses of MES SSR Part-I. (iii) Earthing shall be done in a manner that the inner edge of earth pit is at least 2 metre from the building foundation (extreme outside end) and the minimum distance between two earth electrodes shall be regulated as per IS-3043.
-
-
-
... More
Boring of holes under road, pavement, hard standing by trench less technology using ultra sound technique and necessary machine including supply & fixing HDPE pipe of 80mm bore suitable for 0.4 mpa working pressure all as specified & directed.
150
-
-
... More
M&L welding in repairs exc 2.5cm but not exc 5cm in length, thickness of metal to be welded not exc 6mm, complete all as specified.
20
-
-
... More
Supply & fixing butt hinges of size 50mm, heavy weight, cold rolled mild steel, ISI marked, including necessary welding, fixed in repairs, complete all as specified.
12
-
-
... More
Surface dressing not exc 15cm deep in soft/loose soil.
2000
-
-