Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date17 Jan 2023
Closing Date13 Feb 2023
Tender Amount₹ 46,44,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling Wall and ceiling boards or insulation boards, any thickness,any description, including cover fillets complete all as specified.

450

-

-

... More
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips including providing and fixing new ones complete all as specified and as directed by Engineer-in-Charge.

35

-

-

... More
Demolition of brick/stone masonry built in CM. all as specified.

20

-

-

... More
Taking up or down steel tubing 15 mm bore with connections for cleaning for refixing or removing to store yard complete all as specified of the following description :-

250

-

-

... More
Taking up or down steel tubing 20 mm bore with connections for cleaning for refixing or removing to store yard complete all as specified of the following description :-

150

-

-

... More
Taking up or down steel tubing 25 mm bore with connections for cleaning for refixing or removing to store yard complete all as specified of the following description :-

70

-

-

... More
Dismantling 75/100mm cast iron /PVC pipes fixed to walls or laid in trenches in any position.

200

-

-

... More
Dismantling water tanks and removing to store exc 1000 ltrs and nexc 2000 ltrs

8

-

-

... More
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.

234.09

-

-

... More
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each layer complete.

128.25

-

-

... More
Removing excavated soil not exceedind 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.

105.84

-

-

... More
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including base of manholes etc complete.

5.51

-

-

... More
M&L for Brick work with fly ash bricks old size straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed by Engr-In-Charge.

75

-

-

... More
M&L non skid ceramic tiles 7 to 8 mm thik (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors on 15mm thick screeding in CM 1:6 set set and jointed in neat cement slurry and pointed in white or coloured cement to match complete.

150

-

-

... More
M&L for Glazed ceramic coloured tiles in vertical surface 300x 200x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match on 10mm thick screeding in CM 1:4 complete.

120

-

-

... More
S & F in repair looking mirror 700mm x 500mm bevelled edge mirror of selected quality glass 5.5mm thick mounted on 6mm plywood with aluminium frame fixed to wooden plugs with CP brass screws & cup washers complete all as specifed and directed by Engineer-in-Charge.

20

-

-

... More
S & F refixing' incldues taking down,Resecuring or easing & adjusting, without taking down easing and ajusting and also refixing builders hardware as Refixing in same Opening required including renewal of unserviceable screws, etc.

15

-

-

... More
S&F Pressed steel frames for door with one or more rebates including necessary fixing lugs, hinges,lock strike plate of profile 105x60mm

36

-

-

... More
S& F Flush shutters,30 mm thick door solid core construction, with block board core and plywood face panels, commercial type on both sides

20

-

-

... More
S&F factory made solid panel PVC door shutter with MS square tube 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC sheet stirip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top,lock and bottom rail on either side & as gap insert for top rail & bottom rail .panelling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement S&F in the steel frame at site as per specification.

30

-

-

... More
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified and approved.

120

-

-

... More
S&F Aluminium anodised barrel tower bolts of extruded section, 150 mm long complete.

24

-

-

... More
S&F Aluminium alloy, anodised, sliding door bolt 250 mm long, with haps, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete.

24

-

-

... More
S&F Butt hinges, medium weight, cold rolled mild steel, 100 mm size complete.

60

-

-

... More
S&F Extruded aluminium alloy handles, fabricated type, anodised, 150 mm size complete.

40

-

-

... More
S&F 2nd class hard wood 35mm thick Plain, framed, Glazed shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood partcile board with commercial face veneers.

6

-

-

... More
M&L for painting to new wooden surface over 10cm width or girth with two coat of synthetic enamel paint over a coat of pink primer.all as specified.

24.6

-

-

... More
S&F 100mm lomg butt hinges, cold rolled mild steel medium weight.

42

-

-

... More
S&F Mild steel barrel tower bolt stove enameled black with bright bolt of length 200mm

16

-

-

... More
S&F Mild steel sliding door bolts,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 300mm long .

7

-

-

... More
S&F 125mm long Mild steel pressed handles, oval type,stove enamelled black.

16

-

-

... More
MS work as in framed work such as grills, gratting, guard bars, etc confirming to Fe-410-0

110

-

-

... More
S&F Steel window with side hung shutter incl.box type hinges with steel handle of MS flat 25x5mm and 2nos tower bolt of 100mm long fixed to shutter comp. With glazing bar dovtailed or welded including one shop coat of primer.

10

-

-

... More
S&F Steel window with side hung shutter incl.box type hinges with steel handle of MS flat 25x5mm and 2nos tower bolt of 100mm long fixed to shutter comp. Without glazing bar dovtailed or welded including one shop coat of primer.

10

-

-

... More
PCC 1:3:6 type B-1 using 20mm graded aggregate as in bed blocks of hold fasts etc.

1

-

-

... More
M&L for 15mm thick Rendering in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished fair and even without using extra cement complete.

475

-

-

... More
M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of white wash or tinted complete.

350

-

-

... More
M&L for washing rubbing down and stopping of distempered surfaces of walls and applying two coats of oil Bound Distemper white or tinted complete.

100

-

-

... More
M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of cement paint white or tinted over a coat of white wash complete.

125

-

-

... More
M&L for washing rubbing down and stopping of painted surface of walls and applying two coats of cement paint white or tinted complete.

650

-

-

... More
S&F 3mm sheet glass, ordinary quality and glazing with oil putty in squre n exc 0.5sqm in each pane but forsted.

37

-

-

... More
Providing cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in cills, bed block, copings,bed plates, bond stone, etc including weathering, slightiy rounded or chamfered angles and throating as directed including necessary form work complete.

1.7

-

-

... More
M&L for preparation new or previous untreated steel & iron surfaces of any description over 10cm in with or grith and applying two coats of synthetic enamel paid over & including a coat of red oxide primer complete.

40

-

-

... More
S&F Chromium plated shower rose with swivel joints 75mm size

75

-

-

... More
S&F Tower Rail 600 mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190 gms) complete.

45

-

-

... More
S& F Urinal and Wash Basin Waste Pipe 32mm bore flexible pipe for disposal as specified as dircted

75

-

-

... More
S&F Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (Minimum weight 190 gms) complete.

35

-

-

... More
S&F Vitreous china bowl urinal Haif stalf type, white, with grating and union for discharge pipe including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, including providing & fixing 5 litres cast iron automatic flushing cistern with brackets, 32 mm bore PVC waste pipe and 25 mm bore light grade GI flush pipe complete.

15

-

-

... More
S&F PVC low level flushing cistern 10 litres capacity, white, with all fitting and fixtures including brackets and Bend Pipe with fixing and 32 mm bore PVC flush pipe, complete.

60

-

-

... More
S&F in repair, white, vitreous china WC squatting pan, Orissa pattern 580mmx440mm size with integral foot rest, and connection to flush pipe/trap and connection to anti syphonage pipe etc. including making good to floor as per existing specifications complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110mm bore complete.

250

-

-

... More
S&F PVC (SWR) pipes, single socketed,in any length with rubber ring joints, fixed to walls, 75mm bore complete.

150

-

-

... More
S&F PVC (SWR) bends any radius, 110mm bore complete.

70

-

-

... More
S&F PVC (SWR) bends any radius, 110mm bore complete.

50

-

-

... More
S&F PVC (SWR) branch pieces, single (single Y) equal or uneqal, 110mm bore complete.

15

-

-

... More
S&F PVC (SWR) couplers, 110mm bore complete.

45

-

-

... More
S&F PVC (SWR) 'P' trap, 125/110mm bore complete.

25

-

-

... More
M&L PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 75 mm complete.

120

-

-

... More
M&L for 15mm bore steel water tubes, medium grade. ISI marked, galvanised with all fittings, fixed to walls and ceilling or laid in floors complete.

250

-

-

... More
M&L for 20mm bore steel water tubes, medium grade. ISI marked, galvanised with all fittings, fixed to walls and ceilling or laid in floors complete.

150

-

-

... More
M&L for 25mm bore steel water tubes, medium grade. ISI marked, galvanised with all fittings, fixed to walls and ceilling or laid in floors complete.

70

-

-

... More
S&F Rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, hoisted and fixed in position including connecting up pipes complete.

8

-

-

... More
S&F Bib taps cast copper alloy Chromium Plated with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete.

90

-

-

... More
S&F pillar tapes, with swan long neck cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore complete.

60

-

-

... More
S&F angle valve cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) screwed both ends for iron pipe or for unions 15mm bore complete.

130

-

-

... More
S&F Stop valve cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) screwed both ends for iron pipe or for unions 15mm bore complete.

60

-

-

... More
S&F GUN Metal Glob or gate valves valve cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup screwed both ends for iron pipe or for unions 25mm bore complete.

15

-

-

... More
S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (Minimum weight 210 gms) complete.

15

-

-

... More
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm complete.

130

-

-

... More
Salt glazed stone were drain pipes, grade ‘A’ 150 mm bore (internal dia) laid in trenches over existing concrete bedding and jointed as specified

78

-

-

... More
Cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in packing under and hunching against the sides of pipes, without bedding layer, after they are laid and tested in 150 mm dia of pipe complete all as specified

78

-

-

... More
Cutting into existing manholes or connecting new, drains making good existing benching or forming channel and reforming benching with cement and sand mortar 1:4 or PCC 1:2:4 type B-1 smooth finished and reforming benching as in 150 mm dia of pipe complete all as specified and as directed by Engineer-in-Charge

8

-

-

... More
M&L for 75mm thick Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, , finished even and smooth using extra cement , laid in panels including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete.

250

-

-

... More
De-sludging by removing of semi solid sludge from existing septic tanks of any depth, any capacity in foul condition, including taking and placing in position the manhole cover of any description, removal of sludge & solid content to any place outside defence land and deposting where directed by Engineer-in-Charge.

40

-

-

... More
Providing precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 complete (reinforcement to be measured separately)

2.8

-

-

... More
M&L for Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete.

270

-

-

... More
S & F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of sand colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as complete all as specified.

135

-

-

... More
S & F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of sand colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as complete all as specified.

12.25

-

-

... More
S& F Harrison rails,Stainless Steel ,curtain rod with SS Bracket And SS Stoppers Rools with fixing brackets, stops, rollers etc.

43

-

-

... More
Machine pressed precast conctete interlocking paver block coloured and glossy any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35Grade to IS 15658-2006 manufactured using grey cement and Colour pigment including 25 mm Sand Cushioning complete all as spcified and directed.

43

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete

1

-

-

... More
Supply and fixing anodized snap grid frame work of size 605mm x 605 mm for false ceiling including necessary notching. The snap grid shall consist of anodized aluminium main & cross tee of size 36.5 x 25 x 1.4 mm weighing 0.24 Kg/RM and 23.5 x 26.4 x 1.40 mm weighing 0.191 Kg/RM respectively. The main and cross tee shall be jointed at junction crossing with anodized aluminum angle bracket of size 15mm x 15mm x 1.5 mm weighing 0.12 Kg/RM fixed with suitable MS bolts, nuts and washer. The snap grid (main/cross tee section) shall be supported at ends all along the wall with anodized aluminum angle of size 35 x 25 x 2 mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and fixed in grid support with 2.50 mm dia plain mild steel wire galvanised class 3 fixed in detached works etc to support snap grid, made of aluminum as per specification and Composite cement Ceiling board 6 mm thick in (595mmx 595mm ) pannel make Everst designer ceiling confirming to IS 14862 type B cateagory surfaces complete all as specified and as directed by Engineer-in-Charge.

422

-

-

... More
M&L for cutting into existing manholes/Soak well for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1, reforming benching as required and finishing surface even & smooth for 150mm bore pipe complete all as specified and as directed.

2

-

-

... More
M&L for construction of Soak Well for 25 users, brick masonry, PCC ,RCC and earthwork encluding complete, all as specified and shown on drawings (BTD-830 Sheet No. 1/1).

2

-

-

... More
M&L for 15mm thick Rendering in cement mortar 1: 6on fair faces of brick work or concrete surfaces, finished fair and even complete.

15

-

-

... More
M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of oil Bound Distemper white or tinted over a coat of white wash complete.

115

-

-

... More
M&L 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone agregate as sub base of floors all as specified.

80

-

-

... More
M&L 18-20 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 20mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.

80

-

-

... More
M&L 18-20 mm thick machine cut kota stone slab as in skirting/dado etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 10mm thick screed bed in cement and sand mortar 1:4 complete all as specified and as directed by Engr-in-Charge.

8

-

-

... More
MS work as in hold hast etc.

2

-

-

... More
S&F 2nd class hard wood 35mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood partcile board with commercial face veneers.

4

-

-

... More
Plain cement concrete (1:2:4) type B-0, 40 mm thick as in damp proof course to horizontal or vertical surfaces including necessary form work using water proofing compound as per manufacturer’s instructions complete all as specified and as directed.

9

-

-

... More
M&L Roughly squared stone lintels hammer dressed on face and soffits, hoisted, set and pointed in cement mortor 1:6 n.exc 3 m in length complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
S&F joist , channel, angle, tee section, fixed independently without connecting plates etc. including welding as necessary confirming to Fe-290 Gde E-165

80

-

-

... More
S&F Steel ventilators with top hung shutter including hinges, steel peg stay complete.

2

-

-

... More
S&F stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm, fixed with tinned tacks or galvanised wire staples complete.

2

-

-

... More
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St-240, conforming to Fe- 290 Gde E-165 complete as directed by Engineer-in-Charge and all as specified.

1120

-

-

... More
Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-290 Gde E-165 all as specified and as directed by Engineer-in-Charge.

69

-

-

... More
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 5 cm and dia of shank 5 to 10 mm complete all as specified and as directed by Engineer-in-Charge.

78

-

-

... More
M&L for Framed work of rolled mild steel conforming to Gde Fe 410 W gde E-250 Quality A as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering; doors etc to be prepared for hanging or sliding with and including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting, running rails & guides) and hanging, fastening & fixing complete as in ornamental work.

70

-

-

... More
S& F sand filling under floors or in foundation inxluding watering abd consolidations as specfied

12

-

-

... More
M& L for 75mm thick PCC 1:3:6 type C-1 (Using 20mm gradede crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified.

29

-

-

... More
M&L 5cm thick sand stone slabs in shelves, chajjas, shelves etc n exc 2m in length set and pinted in CM 1:4 complete all as specified.

1

-

-

... More
S & F Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping complete all as specified.

20

-

-

... More
Taking down carefully existing unserviceable Copper/aluminum batten/surface conduit/concealed conduit point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc (including old MS sunken boxes) and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc complete all as specified and as directed by the Engr-in-Charge.

330

-

-

... More
Taking down of unserviceable DBs/switch fuses/changeover in sheet steel enclosure complete with MCBs/Fuse/grips any capacity and removing from site and making good disturbed surface of wall, floor etc. Taking after disconnecting all cable complete all as specified and as directed by the Engr-in-Charge.

3

-

-

... More
Taking down of unserviceable DBs/switch fuses/changeover in sheet steel enclosure complete with MCBs/Fuse/grips any capacity and removing from site and making good disturbed surface of wall, floor etc. Taking after disconnecting all cable complete all as specified and as directed by the Engr-in-Charge.

95

-

-

... More
Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in and including new non-metallic rigid PVC concealed conduit/Surface Conduit , not less than 20 mm dia, medium duty ISI marked, including conduit fittings such as tees, bends etc terminating in and including new sunken box covered with and including 3 mm thick bakelite laminated sheet top cover of approved make for one fan or light or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, multi stranded as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.

272

-

-

... More
All as per item No 111 here-in-before but socket point on the same board with other switches complete as specifed as directed by Engineer - In - Charge

29

-

-

... More
All as per item No 111 here-in-before but socket point on the independent board with other switches complete as specifed as directed by Engineer - In - Charge

80

-

-

... More
All as per item No 111 here-in-before but cable of 2.5 Sq mm for 15 Amp switch socket outlet on independent board complete as specifed as directed by Engineer - In - Charge

22

-

-

... More
S & F Switch piano flush type, Single pole 5 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge

381

-

-

... More
S & F Ceiling rose PVC/poly carbonate insulated body three terminal ISI marked, complete all as specified and as directed by Engineer-in-Charge.

144

-

-

... More
S & F Socket outlet flush type, 3 pin, 5 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge.

109

-

-

... More
S & F Switch piano flush type, Single pole 15 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge

22

-

-

... More
S & F Socket outlet flush type, 3 pin, 15 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge.

22

-

-

... More
Lamp holder insulated body with LED Bulb 9 watt back plate for conduit/casing capping fittings complete all as specified and as directed by Engineer-in-Charge.

108

-

-

... More
Fan regulator electronic type, 230 Volt, 150 Watt with 5 step of control including making holes in laminated bakelite sheet cover and connection complete all as specified and as directed by Engineer-in-Charge.

44

-

-

... More
S&F Decorative ultra slim linear LED lightening fixture, Eco friendly energy efficent 18/20 Watt complete all as specified and directed by engineer-in-charge.

66

-

-

... More
S & F Sheet metal enclosure for distribution boards, suitable for fixing MCBs 240 volts with 200 Amps rated bus bar, SPN, 12 ways double door , supplied and fixed in repair, including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
S & F Sheet metal enclosure for distribution boards, suitable for fixing MCBs 240 volts with 100 Amps rated bus bar, SPN, 8 ways double door , supplied and fixed in repair, including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge.

16

-

-

... More
S & F Isolator(MCB) single pole, 240 volts of rating 6-32 Amps, breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge

126

-

-

... More
S & F Isolator(MCB) suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.

19

-

-

... More
S&F of Feeder pillar box outdoor cubical type factory made vermin protected dust proof with canopy, water proof made out of MS sheet 1.6 mm thick and 50 cm x50 cm x1.6mm thick angle iron base frame having insulated bus bar aluminum 200amps cap 3 phase with neutral bus bar including fixing in PCC bed block complete all as reqd as directed by Engineer in Charge.

3

-

-

... More
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps complete all as reqd as directed by Engineer in Charge.

3

-

-

... More
Supply & fix LED bulk head ,09W / 10 W, IP65 diacast aluminium housing powder coating finished complete all as specified and directed by Engineer-in-charge.

20

-

-

... More
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed by Engineer-in-Charge.

51

-

-

... More
Hanging only ceiling fan taking down vide item ser no 130 and connecting up with provn of 3 core of flexible cable of size 1.5 sqmm after complete rewinding ,over hauling, minor repair as required,painting and to make serviceable with replacement of bearing/ capacitor etc. complete all as specified and as directed by Engr-in-charge.

36

-

-

... More
Fixing only exhaust fan taking down vide item ser no 130 and connecting upincluding provision of 3 core of flexible cable of size 1.5 sqmm after complete rewinding ,over hauling, minor repair as required,painting and to make serviceable etc. complete all as specified and as directed by Engr-in-charge.

15

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I.

23

-

-

... More
Supply and laying in replacement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.00 sq mm 3 core complete all as specified and as directed by the Engr-in-charge.

200

-

-

... More
Protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class 'B' bricks complete all as specified and directed by Engr-in-charge.

5.2

-

-

... More
Local tibba dry sand cushioning for protection of cable complete all as specified and as directed by Engineer-in-charge. Note Local approved tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning.

55.25

-

-

... More
M & L GI tubing light grade for protection of cables with pole/ in ground of size 40mm dia complete all as specified and as directed by Engineer-in-Charge.

92

-

-

... More
Suppy and Fixing LED based street light, housing made up of LM6 pressure die cast aluminium alloy with effectie thermal management, sturdiness. The fixture should have a minimum system efficiency of more than 100 lumen/watt and a minimum system lumen output of not less than 4500 lumens and maximum system wattage 45 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation,

92

-

-

... More
driver should be wthstand up to 440v for 8hrs, two surge proection not less than 5KV one on driver and one external surge protection, PF0.95 and THD10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory.

-

-

-

... More
Suppy and Fixing LED based street light, housing made up of LM6 pressure die cast aluminium alloy with effectie thermal management, sturdiness. The fixture should have a minimum system efficiency of more than 100 lumen/watt and a minimum system lumen output of not less than 15000 lumens and maximum system wattage 150 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation,

3

-

-

... More
driver should be wthstand up to 440v for 8hrs, two surge proection not less than 5KV one on driver and one external surge protection, PF0.95 and THD10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory.

-

-

-

... More
Supply and fixing thermplastic cable junction box with IP 66/67 weather prrof protection for outdoor installation with knockouts for cable entry of size 205x255x122 mm suitable for LT UG cable 10 Sqmm to 25 Sqmm.

95

-

-

... More
Supply & fixing FRLS PVC insulated Copper conductor, two single core of size 1.5sqmm complete for terminal box to street/ flood light fitting.

600

-

-

... More
Supply, laying and testing Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power under ground cable ( heavy duty) with aluminium conductor, 1100 volts LT grade of cross-sectional area 16 Sqmm 4 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid in repair including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately

290

-

-

... More
.(ii) Road manually cutting/floor cutting/cutting holes etc in wall required for laying /fixing of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same)

-

-

-

... More
(b) 10 Sqmm 4 core

365

-

-

... More
(c) 6 Sqmm 2 core

200

-

-

... More
Boring of holes 110 mm dia, manually without disturbing the top surface for laying of cables/GI pipes under road , pavement, hard standing complete all as specified and as directed by the Engineer-in-Charge.

6

-

-

... More
Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm dong complete all as specified and directed by Enge-in-charge

8

-

-

... More
Supply & fix aluminium strip 25mm x 3.15 mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed by Enge-in-charge

70

-

-

... More
Supply & fix GI strip 32mm x 6mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed by Enge-in-charge

20

-

-

... More
M&L for Earthing to equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure,

2

-

-

... More
GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.

-

-

-

... More
M & L test point terminal block point made of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 nos 8mm 25 mm long hex head screw complete all as specified

2

-

-

... More
Supply and laying in replacement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.00 sq mm 3 core complete all as specified and as directed by the Engr-in-charge.

120

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.