Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 34,360Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_621413_1Bid Award Id
ViewTender No
8596/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for rendering 12mm thick in CM 1:6 on brick work or concrete surfaces, including surface finished even and smooth without using extra cement complete all as specified and directed.
153.72
-
-
M&L preparing undecorated newly plastered surfaces of wall and applying two coat of distemper oil emulsion over and including one coat of wall primer and 3mm thick wall care putty with approved colour complete all as specified and directed.
153.72
-
-
M&L for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified & directed.
75
-
-
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket complete all as specified and directed.
290.25
-
-
S&F aluminium powder coated barrel towel bolts of extruded section of length 150 mm complete all as specified and as directed.
8
-
-
S&F brass mortice lock, vertical type size 75 mm 4 lever complete all as specified and as directed.
4
-
-
S&F aluminium powder coated handles fabricated type anodised of size 150 mm complete all as specified and as directed.
8
-
-
S&F MS Butt hinges 100mm size complete all as specified and as directed.
12
-
-
S&F Aluminium (Die cast) body Door closer hydraulically regulated, designation No 3, universal type suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 complete all as specified and as directed.
4
-
-
M&L for 12 mm thick, prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed in aluminium partition with rubber beading complete all as specifird and directed.
16.12
-
-
S&F 5.5 mm thick sheet glass ordinary quality in square exc 0.50 Sqm each in each pane with rubber beading complete all as specified and as directed.
12.36
-
-
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in kitchen slabs, chajjas, lintels, cover slabs for manhole etc complete all as specified and directed.
1
-
-
M&L for Mild steel TMT bars 10 mm dia and over as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified & directed.
70
-
-
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces complete all as specified and directed.
12
-
-
M&L for 3 mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors complete all as specified & directed.
65
-
-
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
7.1
-
-
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation, sub base, filling and mass concrete completed all as specified and directed.
1.76
-
-
M&L for preparation of newly or previously untreated steel surface of any description, over 10cm in width or girth, not otherwise described priming with red oxide primer and applying two coat of synthetic enamel (ordinary tint) complete all as specified and directed.
16.87
-
-
M&L for GI grid frame work of Silhouette grooved design for false ceiling fixed with screw suspended with 6mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleates made out of GI flat 40 x 3 mm size 60mm long complete all as per manufacturers instructions and as directed.
23.43
-
-
S&F 8 mm thick PVC white colour board of size 600mm x 600mm fixed on existing frame work grid complete all as specified and as directed.
25.76
-
-
S&F prepainted galvalume aluminum zinc coating GI based corrugated/plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, including making profile as required fixed with self tapping screws complete all as specified and directed.
25.99
-
-
S&F Framed work as in doors, gates, of angle, or other hollow section with gusset plates, rails, braces,rafters, purlins, trusses etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing etc complete all as specified and as directed.
467.35
-
-
M&L for vitrified tiles (Double charge) light Shade 10mm thick (square/rectangular) polished, area of each tiles exc 0.42 Sqm but not exceeding 1.00 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified.
23.43
-
-
M&L for Vitrified tiles (Double charge) light Shade 10mm thick (square/rectangular) in skirting etc polished, area of each tiles exc 0.42 Sqm but not exceeding 1.00sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick screed bed in CM 1:4 complete all as specified.
0.74
-
-
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in mass concrete complete all as specified and directed.
0.4
-
-
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
4
-
-
Material & labour for sub main wiring with two runs of 1.5 Sqmm FRLS cable multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including surface steel conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and all accessories on wall/ ceiling surface and including one run of 1.5 sqmm FRLS cable multistranded copper conductors 1100 volt grade IS- 694 as earth continuity conductor complete including taking down existing sub main wiring all as specified and directed by Engineer in charge. Note : Two runs of main wire and one run of earth wire & one run of steel conduit shall be measured and paid as one length.
50
-
-
S&F Flame proof weather proof DB SPN DB 8 way MCB DB complete all as specified and directed.
1
-
-
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
5
-
-
S & F MCB SP, 6 to 32 Amp, 10 KA, 'C' series complete all as specified and directed.
12
-
-
S & F MCB SPN, 6 to 32 Amp, 10 KA, 'C' series complete all as specified and directed.
1
-
-
Supply and fix flame proof exhaust fan, 300 mm sweep (12") ,0.25 HP motor,1440 RPM,1120 CFM, single phase complete all as specified and directed.
1
-
-
Supply, laying , testing and commissioning cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with conductor of size 16 sq mm 2 core stranded aluminium complete all as specified and directed.
110
-
-
Excavation in trench, in soft/ loose soil n exc 1.5m wide and n exc 1.5m in depth for foundation, for laying of pipes, cable, errection of pole etc. or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sq m on plan complete all as specified and directed.
6.88
-
-
Returning filling in including spreading leveling watering and well rammingin in layer not exceeding 25 cm in soft/ loose soil complete all as specified and directed.
6.2
-
-
Removal of excavated material to distance 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point in soil complete all as specified and directed.
0.68
-
-
Material & labour for sand cushioning for LT cable with tibba sand one layer of 80mm thickness before laying of cable and other layer of 150 mm thickness after laying of cable and punning down to 180mm to provide a required cover complete all as specified and directed.
Note- Punned thickness only shall be measured and paid.
1.23
-
-
Supplying and laying reinforced precast concrete cable cover, class LV, Type 2, flat, size 300mm x 180mm x 40mm complete all as specified and directed.
140
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60X60cmX 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, precast RCC 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm mmbore midium grade GI protection pipe, test point etc complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
2
-
-
M&L for point wiring complete with 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade IS-694 (Phase- Red/Blue/Yellow, Neutral - Black and earth continuity conductor - Green) drawn through and including PVC casing caping not less than 20mm x 12mm ISI marked ivory colour including accessories like bends, tees junction boxes, etc fixed on wall or ceiling etc including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick phenolic laminated white sheet cover for mounting swiches and sockets complete for One light point/fan point controlled by one switch 5 amp one way complete all as specified and directed.
6
-
-
All as per item No.43 here-in-before but for 5 pin 5 Amps socket outlet controlled by one switch on same board with other switches complete all as specified and directed.
1
-
-
All as per item No.43 here-in-before but for 5 pin 5 Amps socket outlet controlled by one switch on Independent board complete all as specified and directed.
4
-
-
All as per item No.43 here-in-before but for One bell point controlled by one bell push on Independent board complete all as specified and directed.
1
-
-
All as per item No 43 above but with 2.5 Sq mm cable for Independent one 6 pin 5/15 Amps socket outlet including 2.5 Sqmm PVC insulated copper conductor unsheathed 1100 V grade IS-694 FRLS cable for continuous earth wire.
2
-
-
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43-IK with reversal double door, recess mounted, having insulated 200 amp tinned copper bus bar, neutral bus bar, earth bar, din bar detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 8 ways complete all as specified and directed.
1
-
-
S&F MCB SPN, 32 Amp, 10 KA, 'C' series complete all as specified and directed.
1
-
-
S&F switch piano 5 amps flush type single pole one way complete all as specified and directed.
11
-
-
S&F switch piano 16 amps flush type single pole one way complete all as specified and directed.
2
-
-
S&F socket outlet 2 in 1, 3 pin 5 amp complete all as specified and directed.
5
-
-
S&F socket outlet 2 in 1, 3 pin 5 and 15 amp flush type complete all as specified and directed.
2
-
-
S&F Bell push flush type, 5 Amps 240 volts complete all as specified and directed.
1
-
-
S&F Bell Buzzer ding dong type, AC, 230 Volts, Single pole complete all as specified and directed.
1
-
-
S&F ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and directed.
4
-
-
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
4
-
-
S&F wall mounted fan 230 volts single phase oscillating 450 mm sweep suitable for wall mounting including all accessories needed for fixing as complete all specified and directed.
2
-
-
Material & labour for sub main wiring with two runs of 4 Sqmm FRLS cable multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including PVC casing caping of suitable size ISI marked along with fittings and all accessories on wall/ ceiling surface and including one run of 2.5 sqmm FRLS cable multistranded copper conductors 1100 volt grade IS- 694 as earth continuity conductor complete including taking down existing sub main wiring all as specified and directed. Note : Two runs of main wire and one run of earth wire & one run of casing caping shall be measured and paid as one length.
15
-
-
S&F metal plug and socket box with MCB SPN 20A suitable for split AC complete all as specified and directed.