Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 10,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair To Summer Appliances , Ac Geyser At Af Stn Bikaner Under Ge (af) Nal
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MES_565776_2Bid Award Id
ViewTender No
GE (AF) NAL/T-60/2022-23Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Time delay relay
3
-
-
... More
Toggle switch
3
-
-
... More
Auxiliary transformer 24 Volt
3
-
-
... More
Step up relay
3
-
-
... More
PVC connector base plate.
2
-
-
... More
S&F in repair MS Sheet body of 16 SWG suitable for 5 KVA stablizer including painted with 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
2
-
-
... More
S&F in repair connection lead of PVC insulated and sheathed copper conductor cable of size 40/0.0076mm, 3 core complete all as specified and directed.
50
-
-
... More
M&L for shifting of split AC 1.5/ 2.0 TR with indoor and outdoor unit and refixing the same in new position and testing up to the satisfaction of Engr in charge complete all as specified.
5
-
-
... More
Disconnection and taking out, reinstallation and connection of spilt AC of any capacity after carried out the following maintenance/servicing task :-
(a) Cleaning of Air filter with vacuum cleaner(Pressurised air) & washing of the fins using pressurised water by portable pump for AC servicing.
(b) Cleaning of complete AC unit by hand blower removing dust complete (For split AC indoor out door unit)
(c) Servicing blower motor complete.
(d) Complete job for a particular AC shall be carried out on prompt basis and no part work shall be left for next day . (e) The Split AC before servicing would be covered with "closed type horizontal air conditioner wash bags" for insite servicing at critical locations.
52
-
-
... More
S&F in repair condenser unit suitable for 2/1.5 Ton capacity split AC of existing make and model complete all as specified and directed
2
-
-
... More
S&F in repair hermetically sealed unit compressor suitable for split/window type AC 1.5 Ton capacity of existing make and model complete all as specified and directed.
4
-
-
... More
All as per item No 9 above but for split/window type AC 2 Ton capacity.
3
-
-
... More
Supply and charging only Note : Cylinder for refrigerant gas shall be arranged by the contractor at his own cost.
-
-
-
... More
Refrigerant gas R - 22
35
-
-
... More
Refrigerant gas R - 134
20
-
-
... More
S&F in repair copper tube ½ inch bore incl insulation of AC pipe complete all as specified and directed.
40
-
-
... More
S&F in repair copper tube 3/8 inch bore incl insulation of AC pipe complete all as specified and directed.
40
-
-
... More
Disconnection and taking out, reinstallation and connection of window AC of any capacity after carried out the following maintenance/servicing task :-
(a) Cleaning of Air filter with vacuum cleaner(Pressurised air) & washing of the fins using pressurised water by portable pump for AC servicing.
(b) Cleaning of complete AC unit by hand blower removing dust complete (c) Servicing blower motor complete.
15
-
-
... More
S&F in repair condenser unit suitable for 2/1.5 Ton capacity window type AC of existing make and model complete all as specified and directed.
Note : Labour for taking down and fixing shall deemed to be included in item.
2
-
-
... More
S&F in repair to the following items with new of existing make and model suitable for Split/Window type AC 1.5/2 Ton capacity complete all as specified and directed :-
-
-
-
... More
Blower Motor
8
-
-
... More
Remote control
4
-
-
... More
Blade for blower motor
6
-
-
... More
Starting relay
4
-
-
... More
Over load relay
4
-
-
... More
Thermo state switch
4
-
-
... More
Starting Capacitor any capacity
7
-
-
... More
Running Capacitor any capacity
7
-
-
... More
Insulation for copper tube of split AC of capacity 1.5/2 ton complete all as specified.
135
-
-
... More
PCB board for Window/ Split AC upto 2 Ton of exhisting make and as per sample and as specified and directed.
8
-
-
... More
window AC grill for Window AC upto 2 Ton of any exhisting and as per sample and as specified and directed.
5
-
-
... More
S&F in repair hermetically sealed unit compressor suitable for refrigerator of 165 litre capacity of existing make and model complete all as specified and directed.
2
-
-
... More
All as per Srl item No 17 above but for Refrigerator of 300/320 litre capacity.
1
-
-
... More
All as per Srl item No 17above but for Deep freezer of 300/320 litre capacity.
1
-
-
... More
S&F in reapir to the following items with new of existing make and model suitable for refrigerator 165/320 capacity complete all as specified and directed :-
-
-
-
... More
Blower Motor
3
-
-
... More
Starting relay
2
-
-
... More
Over load relay
2
-
-
... More
Thermo state switch
2
-
-
... More
Starting Capacitor suitable capacity
3
-
-
... More
Running Capacitor suitable capacity
3
-
-
... More
Vegetable Tray with glass cover.
2
-
-
... More
Ice tray
2
-
-
... More
Rubber door gasket magnetic type
2
-
-
... More
Shelve PVC coated suitable
2
-
-
... More
S&F in repair hermetical sealed unit compressor suitable for water cooler of 40/80 litre capacity of existing make and model complete all as specified and as directed.
2
-
-
... More
All as per Srl item No 21 here-in-before but for water cooler of 60/120 litre capacity
1
-
-
... More
S&F in repair to the following items with new of existing make and model suitable for water cooler 40/60/80/120 ltrs capacity complete all as specified & directed :-
-
-
-
... More
Starting relay
2
-
-
... More
Over load relay
2
-
-
... More
Thermo stat switch
2
-
-
... More
Starting Capacitor suitable capacity
3
-
-
... More
Running Capacitor suitable capacity
3
-
-
... More
Taking down carefully ceiling fans of 1200 mm sweep from fan hook and refixing in same position after necessary repairs/rewinding etc incl connecting up with flexible twin core cable 23/.0076 from ceiling rose or connector to fan complete all as specified and directed.
40
-
-
... More
Taking down carefully ceiling fans of 1400 mm sweep from fan hook and refixing in same position after necessary repairs/rewinding etc incl connecting up with flexible twin core cable 23/.0076 from ceiling rose or connector to fan complete all as specified and directed.
5
-
-
... More
All as per Srl item No 24 here-in-before but exhaust fan of any sweep.
15
-
-
... More
Rewinding of ceiling fan of sweep 1200mm, of any make & model, with supper enameled copper winding wire of same size as per old winding wire and confirming to relevant IS including replacement of insulation materials, varnishing, greasing & lubricating to ball bearings, GM bushes and testing etc complete all as specified and directed.
40
-
-
... More
Rewinding of ceiling fan of sweep 1400mm, of any make & model, with supper enameled copper winding wire of same size as per old winding wire and confirming to relevant IS including replacement of insulation materials, varnishing, greasing & lubricating to ball bearings, GM bushes and testing etc complete all as specified and directed.
5
-
-
... More
All as per Srl item No 27 above but exhaust fan of 300 sweep and make.
8
-
-
... More
All as per Srl item No 27 above but exhaust fan of 450 sweep and make.
5
-
-
... More
All as per Srl item No 27 above but exhaust fan of 600 sweep and make.
2
-
-
... More
All as per item No 27 here-in-before but pedestal/air -circulator fans of any size make and model.
2
-
-
... More
Supply only in repairs of ball bearing for ceiling/exhaust /Pedestal /Table/Cabin Fan of any make and sweep, complete all as specified and directed.Make : SKF/NBC of size 6201 to 6204
40
-
-
... More
Supply only in repairs of GM bush for ceiling/exhaust /Pedestal /Table/Cabin Fan of any make and sweep complete all as specified and directed
5
-
-
... More
Supply only in repairs of Stainless steel shaft for ceiling/exhaust /Pedestal /Table/Cabin Fan of any make and sweep complete all as specified and directed.
5
-
-
... More
Supply only in repairs of capacitor 2.5/3.15 mfd for ceiling /cabin fan/ table fan of any sweep and complete all as specified. Make : USHA /ASIAN /RENTROL
50
-
-
... More
Supply only in repairs of capacitor 4 mfd for Exhaust fan of any sweep and complete all as specified and directed. Make : USHA /ASIAN /RENTROL
20
-
-
... More
Supply only in repairs of rubber seal for ceiling fan complete all as specified and directed.
10
-
-
... More
Supply only in repairs of mild steel U-clamp including 10mm dia bolt, nut, washer and split pin for ceiling fan completed all as specified and directed.
10
-
-
... More
Taking down carefully old U/s sub main wiring of any type /size including conduit and conduit accessories and making good the disturbed surfaces all as directed.
90
-
-
... More
M/L for submain wiring with two single core PVC insulated unsheathed stranded copper conductor FRLS cable of 4.0sqmm and 4.0 Sqmm as earth lead through surface PVC conduit complete with conduit and conduit accessories not less than 20mm dia all as directed.
90
-
-
... More
Supply and fixing single pole and neutral sheet metal enclosure with socket plug top 2 pin and earth complete with one single pole MCB 20 Amps all as directed.
7
-
-
Evaluation Notes How It Works ?