Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 19,700Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_646709_1Tender No
8458/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply and fix RO Membrane suitable for 400 Ltrs/hour capacity RO Plant complete all as specified & directed.
2
-
-
Supply and fix RO Membrane suitable for 250 Ltrs/hour capacity RO Plant complete all as specified & directed.
1
-
-
S&F in replacement Vertical multistage pump 2HP, 50Hz, 230 V single phase suitable for 400 LPH RO plant complete all as specified and directed. Make: Kirloskar/Wilo/Bharat Bijli/Crompton greaves/CRI
1
-
-
M&L for disconnecting and taking out vertical pump from RO plant, Transportation to workshop and rewinding of vertical pump of capacity 1.5 HP single phase RO plant, with super enameled copper wire of suitable guage including greasing and overhauling testing and reinstallation at site complete all as specified & directed.Location- Tech Area
1
-
-
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity 500 ltrs PVC tank complete all as specified & directed.
8
-
-
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity 1000 ltrs PVC tank complete all as specified & directed.
12
-
-
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity 5000 ltrs PVC tank complete all as specified & directed.
16
-
-
Supply only Chlorine and PH test kit for water suitable for 200 Tests minimum complete all as specified & directed. Make: Aquasol or equivalent
5
-
-
S&F in repair rotational moulded polyethylene water storage tank, three layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 40 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 40 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings of 5000 litres capacity of tank complete all as specified and as directed.
1
-
-
S&F in repair rotational moulded polyethylene water storage tank, three layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings of 1000 litres capacity of tank complete all as specified and as directed.
2
-
-
S&F in repair rotational moulded polyethylene water storage tank, three layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings of 500 litres capacity of tank complete all as specified and as directed.
2
-
-
M&L for Collection of water sample from different location for testing (chemical analyses report i.e. pH ,TDS, magnisium, calcium, hardness, nitrate, sulfate, sodium, potassium, SAR) and submission to AGE office from authorised water test laboratory complete all as specified and directed.
16
-
-
Supply and fix in replacement of tubes "medium grade " galvanised ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors/trenches/under road of the following sizes :- Note:- Earthwork shall be measured and paid seperately.
-
-
-
20mm bore
300
-
-
25mm bore
200
-
-
50mm bore
300
-
-
80mm bore
54
-
-
100mm bore of Heavy grade
30
-
-
Excavation in trenches in soft soil n. exc. 1.5 m wide and n. exc. 1.5 m in depth for foundation, taking out/laying of pipe etc, n. exc. 10 sqm on plan and n. exc. 1.5 mtr in depth and getting out including forming bottom surface to required level and gradient in hard /dense soil complete all as specified and as directed.
77.76
-
-
Returning, filling in excavated soil including spreading, levelling, watering and well ramming in layers not exc 25cm each layers complete all as specified and as directed.
68.25
-
-
Removal of excavated material to a distance n.exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
9.51
-
-
Supply and fixing in replacement gate valve, with iron handle, screwed both ends for iron pipe or for unions and fixing including taking down existing unserviceable valves complete all as specified and as directed for following sizes:-
-
-
-
20 mm bore
20
-
-
25 mm bore
14
-
-
50 mm bore
10
-
-
Supply and fixing CI sluice valve ISI marked class 1.6 with rubber packing sheet, nut bolts washers etc, of size 80 mm bore complete all as specified and as directed.
2
-
-
Supply and fixing CI sluice valve ISI marked class 1.6 with rubber packing sheet, nut bolts washers etc, of size 100 mm bore complete all as specified and as directed.
3
-
-
S & F in replacement of fully automatic star delta starter in sheet enclosure type 415 V, 50 Hz, 3 phase of capacity 5/7.5 HP complete all as specified and as directed.
2
-
-
S & F in replacement of DOL (Direct on line) starter in sheet enclosure type 415 V, 50 Hz, 3 phase of capacity 5/7.5 HP complete all as specified and as directed.
4
-
-
S & F in replacement of fully automatic star delta starter in sheet enclosure type 415 V, 50 Hz, 3 phase of capacity 10/12.5 HP complete all as specified and as directed.
2
-
-
Cleaning only to 10000 Gallon static water tank after pumping out water, removing all scale, dirts, sludge, silt and alike etc and applying two coats of white wash at inner and outer surfaces complete including writing date of cleaning etc all as specified and as directed.
3
-
-
Cleaning only to 25000 Gallon static water tank after pumping out water, removing all scale, dirts, sludge, silt and alike etc and applying two coats of white wash at inner and outer surfaces including writing date of cleaning etc complete all as specified and as directed.
3
-
-
Taking out Submersible Pump/Openwell Submersible pump set of Capacity 7.5/10 HP, 3 phase, 415 volts, 50Hz, AC supply along with column pipe 50 mm dia from from the bore well after disconnecting electric connection, taking to the workshop , dismantling of pump and motor for repairing/ replacing defective parts as ordered, cleaning, servicing, oiling and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed.
6
-
-
M&L for rewinding of motor of 7.5/10 HP submersible pump by suitable gauge copper wire with properly insulating material and replacement of ball bearing set , testing on completion and refixing it on same position complete all as specified & directed.
1
-
-
M&L dismantling electrical connection of monoblock pump of 7.5/10 HP , and transport it for repair to workshop, dismantling of pump and motor for repairing/ replacing defective parts as ordered, cleaning, servicing, oiling and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed.
4
-
-
M&L for rewinding of motor of 7.5/10 HP submersible pump by suitable gauge copper wire with properly insulating material and replacement of ball bearing set , testing on completion and refixing it on same position complete all as specified & directed.
1
-
-
M&L for dismantaling electrical connection of monoblock pump of 15 HP, and transport it for repair to workshop, dismantling of pump and motor for repairing/ replacing defective parts as ordered, cleaning, servicing, oiling and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed.
2
-
-
M&L for rewinding of motor of 15 HP Monoblock pump by suitable gauge copper wire with properly insulating material and replacement of ball bearing set, testing on completion and refixing it on same position complete all as specified & directed.
1
-
-
M&L dismantaling electrical connection of monoblock pump of 40 HP, and transport it for repair to workshop, dismantling of pump and motor for repairing/ replacing defective parts as ordered, cleaning, servicing, oiling and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed.
1
-
-
M&L dismantaling electrical connection of Submersible/Booster pump of 1/0.5 HP , and transport it for repair to workshop, dismantling of pump and motor for repairing/ replacing defective parts as ordered, cleaning, servicing, oiling and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed.
5
-
-
M&L for rewinding of motor of 1/0.5 HP submersible pump/Booster pump by suitable gauge copper wire with properly insulating material and replacement of ball bearing set ,testing on complition and refixing it on same position complete all as specified & directed.
2
-
-
Preparation of old painted surface including scraching and smooth surface and apply two coat of paint on steel surface of pump and motor of any capacity and writing SM/MES no on wall by black paint complete all as directed.
4
-
-
M&L for Replacement of corroded both side flanged GI Medium grade ISI marked column pipe with new 50/80 mm ( Each length of 6 m length) including all T&P for taking out pipe from borewell and refixing complete all as specified and directed. Make; Tata/ Jindal/ Surya Prakash
5
-
-
S&F in repair foot valve 80 mm dia brass casting ISI marked including replacing its MS nut bolts and washers complete all as specified and as directed.
4
-
-
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
180
-
-
M&L for 100mm thick PCC (1:3:6) type C-2, using 40mm graded aggregates as in sub base complete all as specified and directed.
18
-
-
Supply and spreading fine aggregate (sand) for sand cushioning to receive interlocking tile including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
4.5
-
-
M&L for refixing machine pressed precast coloured Interlocking paver block / tiles any shape and size 60 mm thick confirming to IS- 15658-2006 of M-35 grade chemically treated rubber moulded complete all as specified and directed by Engineer-in-Charge.
90
-
-
M&L machine pressed precast coloured Interlocking paver block / tiles any shape and size 60 mm thick confirming to IS- 15658-2006 of M-35 grade chemically treated rubber moulded complete all as specified and directed all as specified and directed by Engineer-in-Charge.
45
-
-
M&L chequered cement concrete tiles 20cm x 20cm x 25mm thick, set and jointed and pointed in neat cement slurry with grey cement and pigment in floors over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
45
-
-
M&L for repair to electronic dosing pump for of capacity dosing rate 04 Kg per square cm of 400 stokes per minute set for chlorine dozing and including suitable guage rewiring copper wire with properly insulating material and replacement of display, internal circuit etc complete all as specified and as directed.
Location: Tech area and domestic area
5
-
-
S&F in replacement pressure pump (with automatic pump controller) of capacity 0.5HP, Max lifting Head 30 metre, Maximum flow rate 3000 LPM, Single phase, 230V, 50Hz complete all as specified and directed.
4
-
-
M&L in repair for Earthing complete with copper plate 60×60cm× 3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20x3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. NOTE : (i) Earth resistance value should be less than 5 Ohms (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip.(iii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends , elbows etc. shall be deemed to be included in the quoted rate. (iv) excavation and earth work shall be measured and paid separately.
2
-
-
S&F in replacement oblique type fire hydrant landing valve single outlet of size 63mm, ISI marked, confirming to IS 5290 complete all as specified and directed.
6
-
-