Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Eprocure
Opening Date12 Nov 2024
Closing Soon3 Dec 2024
Tender Amount₹ 37,06,000
Costs
EMD
₹ 74,120Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683571_1Tender No
GE SGNR/TOK-66 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for 5mm thick rendering in CM 1:3 on ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
395
-
-
M&L for preparation of new plastered interior surfaces of wall and applying two coat of interior acrylic emulsion over a coat of alakali resistance primer complete and one coat of 1mm thick wall care putty finished even and smooth complete all as specified and directed.
570
-
-
M&L for preparation of new plastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/Litre and UV resistance as per 15489: 2004, Alkali resistance exterior paint of required shade (Company depot tinted) with silicone additives @1.43 litre/10sqm over and including priming coat of exterior primer applied @0.90 Litre/10 Sqm complete all as specified and directed.
770
-
-
M&L for preparation of new plastered ceilngt surfaces and applying three coats of white wash complete all as specified and directed.
395
-
-
M&L for complete removal of existing treatment from external walls and washing down with water and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/Litre and UV resistance as per 15489: 2004, Alkali resisstance exterior paint of required shade (Company depot tinted) with silicone additives @1.43 litre/10sqm over and including priming coat of exterior primer applied @0.90 Litre/10 Sqm over new surfaces complete all as specified and directed.
1870
-
-
M&L for complete removal of existing treatment of internal walls and washing down with water and applying two coats of interior acrylic emulsion of required shade and colour complete over a coat of alkali resistance as per manufacturers specification and one coat of 1mm thick wall care putty finished even and smooth complete all as specified and directed.
1870
-
-
M&L for preparation of old decorated ceiling surfaces and applying two coats of white wash complete all as specified and directed.
480
-
-
Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
20
-
-
M&L for providing RCC M-25 ( Design Mix ) as fin fascias, louvers parapets, and railings exc 60 cm in height, newels balustrade, and the like complete all as specified and directed.
3.8
-
-
M&L for providing RCC M-25 (Design Mix) as slab and chajjas complete all as specified and directed.
3.4
-
-
M&L for providing RCC M-25 (Design Mix) as columns, pillars, piers, posts and struts complete all as specified and directed.
2.95
-
-
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick complete all as specified and directed.
13.6
-
-
M&L for formwork to sides of columns, pillars, struts , piers , posts and stanchions complete all as specified and directed.
10
-
-
M&L for TMT bars 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
305
-
-
M&L for TMT bars 6 to 8 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
98
-
-
Taking down steel window / ventilators of any description and size including all connected materials complete all as specified and directed.
10
-
-
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
15
-
-
S&F 1.25mm thick lath thickness steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete push pull or manual type but gear operated type with bevel gear box and crank handle including oiling, greasing complete all as specified and directed.
15
-
-
Taking down and refixing in the same opening or other opening after repair steel rolling shutters any thickness, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete push pull or manual type but gear operated type with bevel gear box and crank handle including oiling, greasing replace damaged parts complete all as specified and directed.
Note : Spare parts to be replaced shall be measured as supply only under respective items of this BOQ.
28
-
-
Supply only ball bearing for rolling shutters complete all as specified and directed.
18
-
-
Supply only safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
10
-
-
Demolition of concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed.
46.8
-
-
Demolition of mud/ unreinforced PCC in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof ) complete all as specified and directed.
10
-
-
M&L for granolithic concrete 1:1:2 floor topping 40mm thick, laid over cement concrete subfloors etc. and finished even and fair surface complete all as specified and directed.
780
-
-
M&L for 20mm thick wearproof topping including approved metallic floor hardner, laid on concrete floors and pavings, and finished even and smooth complete all as specified and directed.
Note : Metallic floor hardner shall be measured as supply only under respective items of this BOQ.
780
-
-
Suppy only metallic floor hardener for mixing in wearproof topping approved quality complete all as specified and directed.
150
-
-
M&L for 75mm thick PCC 1:3:6 type C-1 ( using 20mm graged aggregate) as in plinth protection Iincluding forming joints and filling with bitumen mastic complete all as specified and directed.
580
-
-
M&L for 1.25mm thicm pressed steel frame for doors of size 105 x 60mm with one or more rebates including necessary fixing lugs, lock strike plate, etc complete all as specified and directed.
25
-
-
M&L PCC 1:3:6 type C-1 ( using 20mm graged aggregate) for filling in pressed steel frames and other similar items etc complete all as specified and directed.
0.19
-
-
M&L for rollled mild steel grade Fe-410 -W (Gde E-250 quality A as in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
60
-
-
M&L for Mild steel plain black sheet 1.00 mm thick in wall cladding, shutters, steel gates and similar work, cut to size, holes punched; including round headed screws , clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with rivetted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
10.5
-
-
S&F 100mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed.
5
-
-
S&F 150mm Mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
10
-
-
M&L for 20mm thick screed plaster in CM 1:4 in two layers, first layer 10mm and second layere 10mm thick with 2% of WPC over roof slab, finished even and smooth without using extra cement complete all as specified and directed.
Note : WPC measured and paid separetly under respective item of this BOQ
2315
-
-
Supply only Integral liquid water proofing compound (WPC), conforming to IS and as approved, complete all as specified and directed.
80
-
-
M&L for wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc, M&L for Roof treatment to RCC roof as follows :- (a) Cleaning the roof surfaces thoroughly using wire brushes to remove (b) preparation of roof top surfaces, providing and applying single component a fibre reinforced elastomeric liquid applied as waterproofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibres and having Sun reflective index (SR) of 106 on top of concrete roof surfaces in three coat including self primer at ratio of elastomeric liquid and water as per manufacturer's instruction and coverage @1 Ltr/10 Sqm with a thickness of 650 micron, the vital physical and chemical parameters shall be as under Min Elongation at break of 350%, Results positive hydrostatic pressure of upto 10 bars, crack bridging ability of 2.5mm at 650 microns. The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer-in-Charge/Consultant. 06 Hrs interval between two coats will be maintained.
Note : (i) The roof treatment work will be executed by authorised applicator of the manufacturer and contractor is requied to submit his documents for approval of applicator by GE before execution of work.
(ii) Work will be paid only after receiving of the Waranty Certificate from the manufacturer for 10 years.
2315
-
-
Dismantling of brick work built in cement mortar of any description complete all as specified and directed.
15
-
-
M&L for brickwork with fly ash bricks (old size), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
13
-
-
All as above S.No 41 but except bricks complete all as specified and directed.
Note : Serviceable bricks obtained from dismantling shall be reused in the work after cleaning.
2
-
-
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick sorrounds, glazed with oil putty or fixed with beads complete all as specified and directed.
3
-
-
S&F 4mm sheet glass ordinary quality and glazing with oil putty with glazing clips in square n. exc 0.5 sqm in each plane complete all as specified and directed.
6
-
-
M&L for one coat of synthetic enamel paint on old painted surfaces of steel and iron work over 10 cm width or girth including preparation complete all as specified and directed.
100
-
-
M&Lfor two coats of synthetic enamel paint over a coat of red oxide on steel surface over 10 cm width or girth, not otherwise described including preparation of new surface complete all as specified and directed.
40
-
-
Dismantling of cast iron or reinforced concrete drain pipes of any size jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
98
-
-
M&L for 100mm dia cast iron sand cast waste and vent pipes in any length with or without ears with cement jointed fixed to wall complete all as specified and directed.
65
-
-
M&L for 75mm dia cast iron sand cast waste and vent pipes in any length with or without ears with cement jointed fixed to wall complete all as specified and directed.
33
-
-
M&L for 100mm dia cast iron Bends complete all as specified and directed.
2
-
-
M&L for 75mm dia cast iron Bends complete all as specified and directed.
2
-
-
Taking down eaves gutters and rainwater pipes,PVC (SWR) pipes (any size or pattern) including all fittings heads ,shoes, bends, and removal to store complete all as specified and directed.
50
-
-
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary scaffolding upto the height of building from ground level complete all as specified and directed.
50
-
-
S&F 110 mm dia PVC (SWR) bend with oval access door or 135⁰ angle bend at outlet complete all as specified and directed.
8
-
-
Taking down carefully aluminium point wiring (light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc complete all as specified and directed.
191
-
-
M&L for concealed conduit point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for metal flush boxes suitable length and thickness for mounting, switches, sockets,fan regulator with cover plate with frame and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and directed.
135
-
-
All as per Srl item No 56 above but for one switch socket combination 5/6 amp on independent board complete all as specified and directed.
28
-
-
All as per Srl item No. 56 above but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm including 2.5sqmm earth contuinty conductor complete all as specified and directed.
28
-
-
S&F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed.
135
-
-
S&F switch socket combination 5 pin, type 5/6 Amps flush type complete all as specified and directed.
28
-
-
S&F switch socket combination 6 Pin, 5/16 Amps flush type complete all as specified and directed.
28
-
-
S&F in replacement stepped type, fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed.
7
-
-
S&F ceiling rose surface bakelite three terminals complete all as specified and directed.
109
-
-
S&F in replacement of existing light fitting with 20/22 watt LED batten with aliminium housing and integrated electronic driver, having input voltage AC 90-300V, 50 Hz , 6500K, and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed.
102
-
-
S&F security light fitting LED 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed.
26
-
-
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed.
7
-
-
M&L for painting to ceiling fans with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaing all dust complete all as specified and directed.
7
-
-
Hanging only ceiling fan (M.D. Supply) and connection up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
7
-
-
S&F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including steel dia 25mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed.
90
-
-
S&F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 4 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed.
7
-
-
S&F MCB ‘C’ series type suitable for 240 volts, AC supply 32 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
7
-
-
S&F MCB ‘B’ series type suitable for 240 volts, AC supply 20 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
14
-
-
M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed.
7
-
-
Supply, laying, jointing, testing and commissioning in replacement of 16 Sqmmx2 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed.
225
-
-
Supplying, erecting, testing and commissioning Raising and Lowering type (15 metre height high mast system hot dip galvanised inside and outside) in single dip, suitable for wind velocity as per IS 875 part 3 with only one longitudinal seam weld per section but without circumferential weld including accessories viz head frame, 2 point suspension system with steel wire rope 6 mm dia 7/ 19 gauge, double drum winch, galvanised lantern carriage arrangement suitable for and with 8 nos Luminaires with suitable connection from feeder box symetrically lightening finial, Suitable LED aviation obstruction light,lightening arrestor spikes with suitable Strips,foundation bolts,nuts, anchor plates, templates, trailing cable and intergral power tool for raising and lowering operation of high mast with and including following technical specification:-
2
-
-
(a) HIGH MAST SYSTEM
Height of Mast - 15 m
No of sections - two
Material construction - S355 grade as per BS-ENI00025
Base dia and top diameter (A/F) - 360 mm and 150 mm respectively
Plate thickness and section length - Top - 3mm X 5420 mm , Botton- 4mm X 10980 mm
Cross section of Mast - 20 sidde polygon
standard for of galvanisation - As per BS EN ISO 1461/BS729/IS2629
Size of opening and door at base - 1200 mm X 250 mm
Diameter of base plate - 520 mm
Thickness of base plate - 25 mm
Lightning protection finial - GI single spike
Maximum Wind speed - 50 m/s as per IS 875 (Part-III)
Number of foundation bolts - 6 Nos
PCD of foundation bolts - 445 mm
Type/diametre/length of foundation bolts - TS 600/24 mm dia/750 mm long
-
-
-
(b) LUMINAIRES CARRIAGE
Material of construction - 50 NB ERW Class 'B' MS pipe
Diameter of carriage ring (mm) - 535 mm (ID)
Construction - 6 arm welded 2 sections
Load carrying capacity 8 Luminarie
(c) WINCH / POWER TOOL
Type/SWL of winch - Double Drum /350 Kg
Method of operation - Integral Motor I
Motor Capacity - 0.75 HP Three Phase
No of Speed - 6 Pole, Single Speed
-
-
-
(d) STAINLESSS STEEL WIRE ROPE
Grade/Construction - AISI304.7/I9 Construction
No of Ropes - Two
Diameter (mm) - 6 mm
Braking load capacity (minium) - 2150 Kg x 2
-
-
-
(e)FEEDER PILLAR
Powder coated CRCA steel sheet feeder piller housing 3.15 mm thick (minimum) suitable for
outdoor application with 63 amp four pole MCB incomer, Nature switch, 16 amp, 420 volts
suitable for automatic switching ON and OFF of the luminaries, 9 Amp two contactors and
raise lower push buttons for motor operation, incoming terminals of 50 Sqmm and outgoing
terminals of 16 sqmm for power cable and 2.5 sqmm for motor mounted on suitable
foundation
(f) FOUNDATION
Construction of suitable shallow foundation with M20 grade concrete for high mast
considering the safe soil bearing capacity at site as 10T/sqm at 2 m depth
-
-
-
(g) TRAILING CABLE
PVC insulated PVC scheathed 1100 volt grade ISI marked multistranded copper conductor
cable 6 core 2.5 sqmm adequate length will be provided for smooth operation of high mast light.
-
-
-
FLOOD LIGHT LUMINAIRE
LED flood light luminaires 120 W IP 66 LED Flood light luminaire comprising of epoxy powder Die-cast aluminium housing with weather proof gasket for lamp & driver compartment with system wattage of 120 W . The LED must be of 120 degree view angle, 100 lumen/ watt, lumen maintenace 70% at 50000 hrs, color temperature of 5000-6500K, 70 color rendering and LM 80 test compliance. The driver must be integral APFC and constant current type having CRI 80% THD10% and power factor 0.95 with short circuit protection, open circuit protection, reverse polarity protection, high voltage protection, protection against 5 kV high surges and comply to IEC 60598-1, IEC 61000-3-2, IEC 61547 including PVC insulated three core 1.0 Sqmm FRLS multistranded Copper conductor cable for connection of fitting from gd installed junction box to top hight of pole. The luminaire must have secondary optics with perfectly matched lens for better light control. complete all as specified and directed .
-
-
-
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 4 core complete all as specified and directed.
250
-
-
Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed.
73.2
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
44.9
-
-
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed.
28.3
-
-
M&L for sand cushioning with dry coarse sand to under ground cable below and around after laying the cable jently punning down complete all as specified and directed.
Note : Thickness after punning shall be considered for payment.
22.9
-
-
M&L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed.
2.36
-
-
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type c1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting book made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore medium grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, and 40mm light grade protection pipe complete all as specified & directed.
4
-
-
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6mm galvanized iron strip complete all as specified and directed.
32
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%