Military Engineer Services Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date13 Feb 2025
Closing Date12 Mar 2025
Tender Amount₹ 90,37,500 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(k) Comprehensive numerical protecting relay (ABB- REL series/Schneider-Easergy Series, SIEMENS-Siprotech series) for non directional O/C, E/F, O/V protection type having following additional facilities :- (i)  Trip ckt supervision. (ii) Distribution recorder.  (iii) Event log with date and time. (iv) Suitable to operate on 24 volts DC for auxiliary and control supply (l)  Panel should also have additional facilities :- (i)  Only OEM panels are to be supplied. Partner or franchice are not accepted.   (ii)  Fully internal arc type tested (25 KA for 1 Sec) as per latest IEC 62271-200. (iii)  Vacuum bottles should be tested for 100 full short circuit operations. (iv) Manual closing tripping of CB with compartment door closed. (v)  The panel shall be provided with power pack battery back up for not less than 10 minutes. (vi)  The Height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (vii)  Breaker shall be provided with following contacts. (a) Auxiliary switch with 6NO+6NC mounted on the draw out portion of the switchgear. (b) Position switches with 3 NO+1NC contacts for each position in SERVICE and TEST. Note : The rate quoated is deemed to be included in the following provition :- (i) PCC Foundation as per manufacturer's instruction and as directed. (ii) Battery bank with charging unit of 30 volts 100 AH DC out put, 230 volts AC input with and including 15 Nos of battery, each of 02 volts, 100 AH, all battery enclosed in suitable size sheet metal enclosure including battery charger of suitable capacity (iii) Disconnecting and shifting of exsting main cirucit breaker panel from P-40 power house to SMQ Power house and making necessary connection. (iv) Disconnecting cable from existing 4/2 pole/excavate exsting underground loop and connect with VCBs as directed by Engr-in-Charge

-

-

-

... More
Supply, install, testing & comissioing of 11KV Extensible Outdoor duty (IP 55 enclosure) SF6 gas insulated 3-way manual operated Ring Main Unit comprising of 2 no. LBS and 1 no. Outgoing 630 Amps Vacuum Circuit Breaker, cable termination from the front, breaking capacity 21KA/3sec (Internal Arc Classification AFLR 21kA-1sec with Bottom Exhaust both for tank and cable box as per IEC 62271-200), enclosed in robotically welded stainless steel tank having IP67 Degree of Protection, leak rate of SF6 gas less than 0.1% and tested as per IEC 60056/60694/60298. Protection CTs shall be ring core type, CT ratio at incomer: 30-75-150/1 Amp., Number of Short Circuit Operations at rated short circuit current of 21 kA for Breaker - 50 Nos.. Vaccum Interruptor, protection relay and RMU shall be of same make for better coordination. Coupling shall be from side. (A) NOTE:- Others details:- System Particulars:  (i) Nominal System Voltage : 11kV.    (ii) Voltage variation on supply side : As per IEC.    (iii) Corresponding Highest System Voltage: 12kV.   (iv) Frequency : 50 Hz with ± 3 % tolerance.    (v) Number of Phase : 3 Phases. (vi) Busbar material : Copper,  (vii) Body earthling: Solidly earthed.  (viii) Fault level (minimum) kA /Sec : 21/3).  (ix) Lightning Impulse Withstand Voltage (kVp) : 75    (x) One minute dry/wet power frequency withstand voltage primary (kV rms) : 28KV    (xi) Rated Dynamic Withstand Current (kAp) : 52.5KA. (xii) Number of Short Circuit Operations at rated short circuit current of 21 kA for Breaker - 50 Nos. (xiii) Earth switch with its own making capacity independent of breaker with own snap action mechanism for fast closing independent of operator action (E2 Class).

2

-

-

... More
(B) Applicable Standards for this RMU scope of work - IEC 62271-200.    (i) The design, manufacture and performance of the Ring Main Units shall comply with all currently applicable statutes, regulations and safety codes. Nothing in this specification shall be construed to relieve the bidder off his responsibilities. (ii) Ring Main Units shall conform to the latest applicable, IEC 62271-100, IEC 62271-200. (iii) All live parts, bus bars, shall preferably be enclosed in stainless steel tank Grade SS441 ferrro magnetic material of minimum 2 mm thickness. The RMU shall be type tested for internal arc test of 21KA/1 sec AFLR with Bottom Exhaust for Safety of Personnel for both Tank as well as Cable Compartment as per IEC62271-200. The outer enclosure shall have IP 55 protection for complete switchgear; however it should be Top Opening Canopy & with dedicated IP 55 Cable Compartment; Indoor RMU placed inside Outdoor Enclosure should not be acceptable. The protection relay shall be for 3 O/C + 1E/F (IDMT Type) Self powered numerical protection relay with low and high set of over current and earth fault , MODBUS communication along with RS 485 Port.  (iv) Internal Arc Classification should be with Bottom exhaust only. RMUs should be manufactured, inspected and invoiced from the OEM factory (v) The SF6 gas filled 11 kV, 630 Amps, extensible type, Outdoor to be supplied against this specification shall be suitable for satisfactory continuous operation as per IEC. Note : The rate quoated is deemed to be included in the following provition :- (i) PCC Foundation as per manufacturer's instruction and as directed. (ii) Disconnecting cable from existing 4/2 pole/excavate exsting underground loop and connect with VCBs as directed by Engr-in-Charge

-

-

-

... More
Material and labour as in repair earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32mmx6mm by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanized iron pipe light grade 40mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I) all as specified and directed by Engr-in-Charge

8

-

-

... More
Taking out existing unserviceable XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 11000 volts of any size laid in trenches, ducts along the walls, through pipes, under road, pole etc. complete all as specified and directed ;-

300

-

-

... More
Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge.

1666

-

-

... More
M&L excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m deep, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed

780

-

-

... More
M&L removal of excavated material / soils to a distance n exc 50m and depositing where directed at a level not exceeding 1.5m above the straight point complete all as specified and directed.

260

-

-

... More
M&L returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm in soft / loose soil complete all as specified and directed.

520

-

-

... More
M&L sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed.

160

-

-

... More
Material and labour for fixing of new un-reinforced pre-cast concrete cable covers, class HV, Type 1, flat, size 300mmx l80mm x 40mm complete all as specified.

10700

-

-

... More
Supply, testing and Laying on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 11000 volts laid in floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 185 Sqmm 3 Core. Note : (I) Contractor is responsible to rectify the damage occured in road, any strucure, any type of cable etc during excavation/ execution of work and the rate quoted is deemed to be incl. No extra cost shold be climbed by contractor.

2030

-

-

... More
Dismantling and taking down air break gang operated switch vertical / horizontal mounted including insulators and operating mechanism / replacement of old unserviceable air break switches of 400 Amps complete all as specified and directed.

1

-

-

... More
Supply & install 11 KV 3 Phase Gang operated air break switch 400 amp capacity, horizontal type complete with locking arrangement and fixing the gang operated switch on existing two/four pole structure including making all jumper connections with insulated leads of suitable size with line tops etc, all as specifed and directed.

1

-

-

... More
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm.

2

-

-

... More
Cable jointing kit for 11 KV (Earthed) grade cable for straight though heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm.

3

-

-

... More
Dismantling of cross arms, supports, clamps and back plates incl nut bolts washers, any shape or size as indicated complete all as directed. Note : (i) Existing MS work is of different sizes and fixed at different locations. While dismantling, ACSR conductor shall be loosened properly as per direction of Engr-in-Charge (ii) T & P required for dismantling shall be arranged by the contractor at his own cost.

0.8

-

-

... More
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint

1.2

-

-

... More
Supply and fix as in repair HT cable route indicator made up of Cast Iron (Round Die) 4" Round Plate & 3mm thickness, MS angle of 50 cm duly painted complete all as specified and directed.

40

-

-

... More
Material and Labour boring of road crossing of size 100mm dia by using trenchless technology with use of machinery equipments complete without damaging the surface at suitable depth for drawing cables/pipe lines etc. complete all as directed. Note : (i) Location of boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while quoting his rates.

20

-

-

... More
Supplying and laying as in repairs GI tubing 100mm bore light grade incl all accessories for pssing of cables for mechanical proctection, laid under Plinth /Road/ Floors/ Paths Culverts or fixed on wall or concealed in wall / floor with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works all as specified and directed.

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.