If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair To External Electric Supply And Repair To Em Installations Of Zone B Area At Af Stn Bikaner
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_675619_1Bid Award Id
ViewTender No
GE (AF) NAL/T-45/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed.
69
-
-
... More
Material and labour for fixing of new un-reinforced pre-cast concrete cable covers, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified.
5270
-
-
... More
Material and labour for fixing of new un-reinforced pre-cast concrete cable covers, class HV, Type 1, flat, size 300mmx l80mm x 40mm complete all as specified.
1170
-
-
... More
Taking out defective cable XLPE/PVC sheathed 1100 volt/11000V grade heavy duty armoured with aluminium conductor from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
-
-
-
... More
2 core 10 Sqmm
100
-
-
... More
4 core 16 Sqmm
100
-
-
... More
3.5 core 25 Sqmm
100
-
-
... More
3.5 core 35 Sqmm
120
-
-
... More
3.5 core 50 Sqmm
120
-
-
... More
3.5 core 95 Sqmm
100
-
-
... More
3.5 core 120 Sqmm
100
-
-
... More
3.5 core 240 Sqmm
50
-
-
... More
3 core 185 sqmm
50
-
-
... More
3 core 120 sqmm
80
-
-
... More
3 core 95 sqmm
80
-
-
... More
Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed.
100
-
-
... More
All as per item No 8 but size 4 core 16 Sqmm.
100
-
-
... More
All as per item No 8 but size 3.5 core 25 Sqmm.
100
-
-
... More
All as per item No 8 but size 3.5 core 35 Sqmm.
120
-
-
... More
All as per item No 8 but size 3.5 core 50 Sqmm.
120
-
-
... More
All as per item No 8 but size 3.5 core 95 Sqmm.
100
-
-
... More
All as per item No 8 but size 3.5 core 120 Sqmm.
100
-
-
... More
All as per item No 8 but size 3.5 core 240 Sqmm.
50
-
-
... More
All as per item No 8 but HT cable 11 KV of size 185 sqmm 3 core
50
-
-
... More
All as per item No 8 but HT cable 11 KV of size 120 sqmm 3 core
70
-
-
... More
All as per item No 8 but HT cable 11 KV of size 95 sqmm 3 core
60
-
-
... More
Dismantling insulators any type, any size from its original position and removing from site complete all as specified and directed.
21
-
-
... More
S&F pin type porcelain vitreous white or brown insulator incl one galvanised MS spindle, two washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade fixed on poles/cross arms of upto 9 m long complete all as specified.
8
-
-
... More
All as per item no. 20 150mm height, 150mm dia for 11000 volts grade.
4
-
-
... More
S&F shackle type porcelain vitreous white/brown or green insulator incl galvanised mild steel straps, washers, insulator bolts, washers and nuts for working pressure 1100 volt section of strips 31x5 mm bolt dia 14 mm max dia 115 mm, height 100 mm fixed on poles/cross arms of upto 9 m long, complete all as specified.
6
-
-
... More
S&F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
3
-
-
... More
Material and Labour boring of road crossing of size 100mm dia by using trenchless technology with use of machinery equipments complete without damaging the surface at suitable depth for drawing cables/pipe lines etc. complete all as directed. Note : (i) Location of boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while quoting his rates.
25
-
-
... More
Dismantling and taking out the old stay assembly complete incl demolition of plain cement complete all as specified and directed. Note : (i) Unit rate of this item includes the loose/disconnect the all accessories which are connected to stay assy includng necessary excavation as directed. (ii) Existing stay assy are fixed on the LT/HT pole of PCC or steel tubular pole, nothing extra shall be paid on this account.
2
-
-
... More
Material and Labour Stay assembly complete with accessories as shown in electrical plate No 1 incl GI Adjustable Stay Rod of 16 mm Dia, GI Stay wire of size 7/4 mm incl stay clamps, loop type insulator, excavation in any strata and PCC 1:3:6 concrete all as specified and directed. Note:- Unit rate of this item includes the cost of earthwork, loop type insulator, PCC and stay wire.
2
-
-
... More
Material and labour for painting with synthetic enamel paint of two coats of post office red/white paint on HT PCC pole upto 1.5mtr height from coping in alternative red and white, strip of 30cm each and writing pole numbers with black paint.
10
-
-
... More
All as per item No 27 above but two pole structure and altenatively red and white strips on HT pole
1
-
-
... More
All as per item No 27 above but four pole structure and altenatively red and white strips on HT pole
2
-
-
... More
Material and labour for painting with two coats of synthetic enameled paint on PCC pole upto 1.5 mtr above the GL in alternatively black and white strap of 30 cm each after scrapping/removing the existing paint and the preparation the surface of PCC LT pole complete.
15
-
-
... More
Material and labour for painting above the copping upto 1.5 mtr in alternatively black and white strips of 30 cm each & rest of the portion with two coats of silver/aluminium paint on steel tubular LT pole of any height after scrapping/removing the existing paint and the preparation the surface of steel tubular pole LT including painting of the channel cross arms, nut, bolts & washer, street light bracket and clamps complete all as specified and directed
15
-
-
... More
Material and Labour for removing old 20mm stone aggregate from 4 pole structures and resurfacing new stone aggregate 40mm after making good to the existing surface upto 15cm height complete all as spefied and directed
15
-
-
... More
Taking down/removing all connections of four pole structure incl all jumpers and complete rejumpering using new ACSR connectors of adequate length through insulated pipes and connections using aluminium lugs/sleeves of directed sizes and treating with conducting jelly and testing of structure before charging with electric supply all to the satisfaction of Engr in charge.
2
-
-
... More
S & F in repairs Mild steel work in framed work such as grills, Gates, Framed guard bars, gratings, ladders, Cable trays, Fencing etc., with ends of bars soldered/welded and/ or riveted, or forged into spikes, and similar work confirming to Fe 290 E-165 incl two coats of mettallic paint over a coat of mettallc primer complete all as specified and directed.
50
-
-
... More
M&L as in repairs lightning Arrestor Expulsion type Transmission Class 65 Kilo Amps 11000 V Grade incl connecting complete all as specified and directed.
1
-
-
... More
Shifting of Transformers upto 630 KVA from one substation to other sub station in the case of any breakdowns by using man power and mechanical means after disconnecting all electric connections and reconnecting in new locations within 263 SU area as directed. Note : (i) Contractor shall provide all the T& P including transportation for shift and nothing extra shall be paid on account of loss of manpower during shift. Tenderer is hereby advised to keep in mind this factor before quoting his rates.
1
-
-
... More
Supply and fix in repairs GI strip 32mm x 6mm burried in ground / laid in floor / fixed to wall on saddles / on porcelain insulators etc complete all as specified and directed. Note : Excavation and earthwork shall be measured and paid for separately.
20
-
-
... More
Material and labour as in repair earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32mmx6mm by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanized iron pipe light grade 40mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I).
5
-
-
... More
Supply and fixing as in repairs MCCB of 63 Amps , 4 pole, 415 volts, 50 Hz, rupturing capacity 16 KA, connection with proper size of thimbles complete all as specified and directed.
5
-
-
... More
Supply and fixing as in repairs MCCB of 100 Amps , 4 pole, 415 volts, 50 Hz, rupturing capacity 16 KA, connection with proper size of thimbles complete all as specified and directed.
5
-
-
... More
Supply and fix as in repairs MCCB, 125A, rupturing capacity 16 KA , 415 volts 4 pole complete all as specified & directed.
4
-
-
... More
Supply and fix as in repairs MCCB, 160A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
4
-
-
... More
Supply and fix as in repairs MCCB, 200A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
4
-
-
... More
Supply and fix as in repairs MCCB, 250A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
2
-
-
... More
Supply and fix as in repairs MCCB, 400A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
2
-
-
... More
Fabricate, supply , install, test and commission LT feeder pilar box/panle board, outdoor type, fabricate with 3.15mm CRCA sheet mounted on 50x50x6mm MS angle, 3 phase 4 wire, 440v, AC, 50 Hz, with TPN aluminium bus bar of capacity 600 Amps with pvc heat shrink colour code sleeves, mounted on porcelin insulators complete volt and amp meter , selectro switch with all accessories and consist of the foloowing switch gear: - ( Sub Bldg & AC Panel)
(a) Aluminium bus bar 3 phase & neutral of capacity 600 Amps (a) Changeover switch 400 Amps - 01 No
(b) MCCB 4P 400 Amps (35KA) - 01 No Incomer
(c) MCCB 4P 200 Amps (35KA) - 01 No Out going
(d) MCCB 4P 100 Amps (35KA) - 01 No Out going
(e) MCCB 4P 63 Amps (25KA) - 02 No Out going
(f) MCCB 4P 40 Amps (25KA) - 01 No Out going
(g) MCCB 4P 16 Amps (25KA) - 02 N0s Out going
(h) MCB 4P 10 Amps (16 KA) - 02 N0s Out going
(j) RYB Phase Indication lamp with fuse 1 set
(k) Digital multi function meter with CT 400/5A
1
-
-
... More
M&L trimming of tree branches on both sides of LT alminium conductor overhead complete all as specified and directed. NOTE : (i) Cutting branches shall be dumped in specified locaton as directed by Engr-in-Charge.
(ii) Contractor shall provide the ladder of required size including T&P to his worker and nothing extra shall be paid on this account.
1300
-
-
... More
Supplying and laying as in repairs GI tubing light grade incl all accessories for pssing of cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall / floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works all as specified and directed. (MS works including painting will be measured under seperate item in Schedule)
-
-
-
... More
(a) 80 mm bore
15
-
-
... More
(b) 50 mm bore
15
-
-
... More
Taking out and Re-laying of existing HT/LT UG cable of any size after jointing using LT/HT cable joining kit complete all as specified and directed.
Note : (i) Excavation incl earth work shall be deemed to be incl in quoted rate. (ii) Joint shall also be measured and paid for separately under respective item of this Schedule
6
-
-
... More
S&F LT Cable joining kit straight through heat shrinkable type complete with joining materials suitable for LT Armoured cables of size upto 50 Sqmm 3.5 core all as directed.
2
-
-
... More
S&F LT Cable joining kit straight through heat shrinkable type complete with joining materials suitable for LT Armoured cables of size 70-120 Sqmm 3.5 core all as directed.
2
-
-
... More
S&F LT Cable joining kit straight through heat shrinkable type complete with joining materials suitable for LT Armoured cables of size 150-185 Sqmm 3.5 core all as directed.
2
-
-
... More
S&F LT Cable joining kit outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for LT Armoured cables of size upto 50 Sqmm 3.5 core all as specified and directed.
5
-
-
... More
S&F LT Cable joining kit outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for LT Armoured cables of size 70-120 Sqmm 3.5 core all as specified and directed.
4
-
-
... More
S&F LT Cable joining kit outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for LT Armoured cables of size 150-185 Sqmm 3.5 core all as specified and directed.
4
-
-
... More
Re-stretching the existing LT/HT over head line consisting of 5/4/3 conductors of any size and one GI wire after removing serviceable/unserviceable separators carefully including opening and reconnecting of jumpers binding conductor over the insulator properly with the help of binding wire 14 SWG and re-fixing separators in its original position complete all as specified and directed by Engineer-in-charge Note : 1. The cost of binding wire is deemed to be included in quoted rates. 2. The distance between two poles for single HT conductor/earth wire will be consider as one span.
20
-
-
... More
Disconnection of Transformer from HT/LT side at site, dehydration and filtration of the transformer oil with the help of oil filtration plant of any capacity of distribution transformer indoor/outdoor type 11/0.433 KV. Notes a) The unit of payment under this item shall be for the oil required for all process to entire completion of the job.
b) New oil required for topping up before dehydration & filtration shall be measured and paid separately under relevant item.
c) The dielectric strength of oil shall not be less than 45 KV when maintained a gap of 3mm for one minute all as specified and directed.
d) All T & P required for dehydration shall be arranged by the contractor at his own.
900
-
-
... More
Supply and filling new transformer oil of superior quality conforming to IS 335:93 complete all as specified and directed. Make : POWER OIL/SAVITA/CASTROL
Note : (i) The dielectric strength of oil should not be less than 60 KV when maintained a gap of 3mm for one minute complete all as specified and directed. (ii) Contractor shall bring the transformer oil in sealed container and after use of oil, container shall be property of contractor and nothing extra shall be admissible on this account..
150
-
-
... More
Supply and fixing as in repair LT bushing assembly complete with insulator, brass stud rod, nuts, washers, gasket etc complete with accessories suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V complete all as specified and directed.
2
-
-
... More
All as per Srl item No 59 above but HT bushing.
2
-
-
... More
Supply and fixing as in repair oil drain valve cast copper alloy any dia suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V of existing make complete all as specified and directed.
2
-
-
... More
Supply and fixing as in repair 6mm thick cork sheet set (Rubberized cork /neoprene) for top cover suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V of existing make complete all as specified and directed. Note:- Size of sheet shall be as per existing cover. Hence, no claim whatsoever shall be entertained by the Deptt for any misunderstanding.
2
-
-
... More
Supply and fixing in replacement breather assembly complete set suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V of existing make complete all as specified and directed.
2
-
-
... More
Supply and replacement silica gel complete all as specified and directed.
3
-
-
... More
Material and labour Spray painting outer surface of transformer with two coats of synthetic enamel paint after scraping, removing, washing and cleaning of old paint, upto 630 KVA transformer 11KV / 433V complete all as specified and directed.
2
-
-
... More
Supply and fixing as in repair temperature gauge suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V as existing make complete all as specified and directed. Make : Feibig / H Guru / Anergy
Note : _ These transformer are located /fixed at different location and of different sizes, tenderer are hereby advised to see this aspect before quoting their rates and no claim what soever shall be entertained by the department on account any misunderstanding.
2
-
-
... More
M&L as in repair heavy duty double break fuse switch HBC/HRC fuse type TPN 415 Volts 200 amps capacity with 03 Nos HBC fuse link complete all as specified and as directed. Make : HAVELLS/BRITE/STANDARD/L&T/C&S
1
-
-
... More
Supply & fixing as in repair cable jointing kit for 11 KV (E) grade for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable upto 120 to 185 Sqmm 3 core XLPE cable armoured aluminium conductor complete all as specified and directed. Note : Unit rate of this item also includes the cost of excavation and earthwork though required for replacement of the existing joint.
2
-
-
... More
All as per item No 68 above but of size 95 sqmm 3 core
2
-
-
... More
All as per item No 68 above but outdoor type of size 120 to 185 sqmm 3 core
4
-
-
... More
All as per item No 68 above but outdoor type of size 95 sqmm 3 core
4
-
-
... More
Supply, jointing & testing as in repair cable jointing kit for 11 KV (E) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 120 to 185 Sqmm complete all as specified and directed. Note : Unit rate of this item also includes the cost of excavation and earthwork though required for replacement of existing joint.
3
-
-
... More
Supply, jointing & testing as in repair cable jointing kit for 11 KV (E) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 95 Sqmm complete all as specified and directed. Note : Unit rate of this item also includes the cost of excavation and earthwork though required for replacement of existing joint.
2
-
-
... More
Supply and fixing in replacement of cable route indicator for HT UG Cable of 11000 Volts 80 mm dia CI Plate marked on HT cable bolted with 40 x 5 mm flat iron member of height 0.9 mtr, embedded in PCC 1 : 3 : 6 type C2 of size 20 x 20 x 30 cm block complete all as specified and directed.
30
-
-
... More
Dismantling of cross arms, supports, clamps and back plates incl nut bolts washers, any shape or size as indicated complete all as directed. Note : (i) Existing MS work is of different sizes and fixed at different locations. While dismantling, ACSR conductor shall be loosened properly as per direction of Engr-in-Charge (ii) T & P required for dismantling shall be arranged by the contractor at his own cost.
1
-
-
... More
M&L cross arms, bracings, supports, clamps and back plates fabricated from steel section, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. Note : Nuts, bolts, washers shall be measured and paid separately.
1
-
-
... More
S&F PVC line seperator for separating 3/4/5 LT overhead lines complete all as specified and directed.
60
-
-
... More
M&L detecting /locating fault of HT 11KV UG cable of size 95 to 185 Sqmm using pin point fault locator machine complete all as specified and directed (Note: Straight through/cable end joints are measured and paid separately)
5
-
-
... More
Dismantling of damaged steel tubular/PCC pole of size 9 mtr for disposal all as specified and as directed. Note :Unit rate of this item includes the cost of dismantling of Steel tubular/ PCC pole and excavation and earthwork complete as directed.
2
-
-
... More
Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged welded poles complete with MS base plate of 6 mm thick of size 300mm x 300mm, finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of ERW MS tubing conforming to IS-2713 ( Part II),1980 type 410-SP-31, 9 meters long L.T pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, painting with two coats of aluminium paint over a coat of primer incl excavation incl PCC complete in post hole in any type of strata, PCC 1:2:4 foundation, filling, in post holes with PCC 1:3:6 and cylinderical coping with PCC 1:2:4 of size 045x.3 complete all as specified and directed (Note : Unit rates of this item includes the cost of PCC in foundation, PCC coping and excavation and earthwork)
2
-
-
... More
M&L for repairing of exsisting GOD switch 11KV mounted on HT pole by changing the burnt out male /female contacts, adjusting the allignment of operating rod , lubricating the contacts with petroleum jelly and taking out operating handle with clamps from the GOD switch to carry out repairs by cutting the operating rod to the required length and refixing the GOD switch alongwith handle and new clamp etc and making the GOD switch easily functionable from ground complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
M&L in repairs 40mm thickness, 2nd class hardwood planks, n exc. 25 cm in width and fixing on angle iron frame of 2/4 pole structure, screwing with existing iron structure complete suitable length laying adjust one by one including one coat of paint over a coat of pink primer complete all as specified. Note : Width and langth of plank shall be as per existing / as directed.
8
-
-
... More
Taking out the damaged / low earth result earthpits and carry out necessary repairs and refilling the charcoal dust, salt and chemical compound as mentioned below :- a) Removing the earthpit cover/earthstrip connections from test point
b) Digging the earthpit ranging from 4 feet to 10 feet using 80mm bore pipe as required according to the condition of soil in earthpit
c) Filling the earthpit initially with earth enhancing compound and chemically treated earth booster. d) Filling the earthpit by earth compatible charcoal and salt
e) Lastly watering the earth pit f) Covering the earth pit with existing covers and testing the earthpit resistance value and connecting the earth strip in its original position.
Note : Materials required for replacement shall be measured and paid separately under relevant item as supply
8
-
-
... More
Supply only the following items :-
-
-
-
... More
Earth compatible Charcoal best quality
200
-
-
... More
Mineral Salt
144
-
-
... More
Chemically treated earth booster
160
-
-
... More
Dismantling/taking down old unserviceable ACSR conductor of any size from LT / HTpoles over head electric line after disconnecting from insulators complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply and stringing PVC insulated aluminium conductor steel reinforced (ACSR) stretching properly to achieve proper sag on insulators and binding with aluminium tape/binding wire connectors, PG clamps , jumpers etc complete of size (Note : 3 % for sag shall be added in measurements)
1
-
-
... More
Supply and fix heavy duty power shunt capacitor 440v 3 phase 50HZ of type cylinder/box of following capacity. Make : L&T, Epcos,Siemens
-
-
-
... More
(a) 5 KVAR Rating
2
-
-
... More
(b) 8.5/10 KVAR Rating
2
-
-
... More
(c) 20 KVAR Rating
2
-
-
... More
S&F in repair Automatic Transfer Switch, four pole, 415V, 50Hz, 100A, Suitable for two way main and backup power system, auto change and auto recovery, Can expand functions by outer connection, Auto, remote, and manual control functions, Delay of 0.5 s signal detect complete protection with enclosure complete all as specified and directed by Engr-in-Charge. Make : Havells model No IHYFCDE100 or equivalent in other specified make.
1
-
-
... More
M &L easing and adjusting loose door shutter of LT Panels including replacement of old rusted hinges by new one and welding complete all as specified and directed. Note:- Use of welding machine is included in the unit quoted rate.
8
-
-
... More
M&L for repair to LT Panel Indoor/outdoor type of any size by disconnecting all electric connections, removal of complete internal wiring and replacing the internal wiring with & including new PVC insulated stranded copper conductor FRLS cables of existing size but not less than 6 sqmm with proper copper lugs, thimbles, minor extras and replacing other unserviceable accessories to make the panel fully functional complete all as specified and directed.
Note : Accessories except wiring/lugs/thimbles/minor extras directed to be replaced shall be measured and paid separately under respective items.
4
-
-
... More
S&F in repair indicating lamps (Set of three) in existing LT Panel board of type integrated LED lamp for operating voltage 240 volt AC complete all as specified and as directed.
4
-
-
... More
S&F in repair Voltmeter digital type 0-500 Volts complete all as directed.
4
-
-
... More
S&F in repair Ammeter digital type (0-500A) complete all as specified and as directed.
4
-
-
... More
Repairing of unserviceable MCCBs/MCBs/changeover switch in LT panel/ DBs any type including replacing of burnt out lugs, including cutting of burnt cable terminals ,prepare and crimping the cable lugs with LT cables in no light/unhealthy light complaints and making serviceable in all respect by providing skilled manpower.Work shall also include checking and removal of leakages in neutral and phase in 440/220 Volts connection as and when directed.NOTE:- (a) Minor items like cable lugs,Insulation tape,nut,bolts etc deemed to be included in rate quoted
8
-
-
... More
Servicing of servo voltage stablizer of capacity 30KVA/75 KVA , 3 Phase 50 Hz with testing of wiring and testing with OV,UV protection with reverse phase and overload and replacement of unserviceable parts like controller , sevo motor, gear set ,RC ,micro switch complete all as specified and directed..(Note : Spare parts will be measured and paid separately under relevant items of schedule)
1
-
-
... More
Supply only following spare parts for 30KVA/75 KVA sevo stablizer
-
-
-
... More
Micro processor controller
1
-
-
... More
Servo motor 10 kg torque
1
-
-
... More
Relay
1
-
-
... More
Micro switch
1
-
-
... More
Gear set
1
-
-
... More
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
6
-
-
... More
Supply and fix OFF LOAD change over switch 415V ,50 Hz 4 pole of capacity 200 Amps including taking out the old unserviceable change over switch, complete all as specified and as directed.
1
-
-
... More
Supply and fix OFF LOAD change over switch 415V ,50 Hz 4 pole of capacity 125 Amps including taking out the old unserviceable change over switch, complete all as specified and as directed.
1
-
-
... More
Dismantling and taking down air break gang operated switch vertical / horizontal mounted including insulators and operating mechanism / replacement of old unserviceable air break switches of 400/200 Amps complete all as specified and directed.
3
-
-
... More
Supplying and fixing installing, commissioning and testing HT 11KV, 3 phase system, outdoor type gang operated switch, air break type suitable for vertical mounting complete with necessary insulators and separators, set of drop out fuses (12 insulators) and operating handle of GI pipe 25 mm dia, medium grade rod of suitable length (mechanically operating arrangements), locking arrangement with lock and two keys complete of rating 400 Amp complete all as specified and directed.
2
-
-
... More
Supply & fix 11 KV 3 Phase Gang operated air break switch 400 amp capacity, horizontal type complete with locking arrangement and fixing the gang operated switch on existing two/four pole structure including making all jumper connections with insulated leads of suitable size with line tops etc, all as specifed and directed.
1
-
-
... More
Supply only 11KV HT fuse wire of 5 amp capacity all as specified and as directed.
2
-
-
... More
All as per srl item No 100 above but 10 amps.
3
-
-
... More
All as per srl item No 100 above but 20 amps.
3
-
-
... More
All as per srl item No 100 above but 30 amps.
3
-
-
... More
Attending, Repairing/restoring of electric power supply in the AF stn Sulur area, after identifying fault in HT 11 KV or LT 415 volt system, RMU,VCB, LT Panels, two/ four pole structure, transformers, Over head lines in any section or circuit, including checking of insulators, lightning arresters, GODs, LT Panel Boards and all electrical accessories and making it serviceable in all respect including replacement of nut, bolt, washers and minor parts/spares, insulation tapes and cable sockets of any size complete all as specified and as directed. Note : (i) Major items required to be replaced/repaired will be measured under relevant items of schedule. (ii) Excavation and earth work if required will be measured separately. (iii) Complaints will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x7 Days). If the contractor shound send electricial/technicial to attend the complaint within 2 hrs failing which penalty charges @ Rs. 500/- per hours shall be recovered. (iv) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same.
35
-
-
Evaluation Notes How It Works ?