Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Machinery and Tools
Eprocure
Opening Date7 Jan 2025
Closing Soon27 Jan 2025
Tender Amount₹ 41,34,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No.1 here-in-before but for capacity of 110 KVA to 200 KVA DG Set.

14

-

-

... More
All as per item No.1 here-in-before but for capacity of 210 KVA to 250 KVA DG Set.

4

-

-

... More
All as per item No.1 here-in-before but for capacity of 320 KVA to 600 KVA DG Set.

2

-

-

... More
NOTE FOR ITEM NO. 1.00 to 5.00 :- Maintenance and servicing of DG sets shall be carried out twice during the period of CA. Qty of Each Jobs considered accordingly against iitem No 01 to 05.

-

-

-

... More
Supply and fix in repair of battery, 12 V 100 AH, including testing for its proper functioning complete all as specified and directed by Engineer-in-charge. Note :- Battery shall be of original make only accepted No substitute of battery.

4

-

-

... More
Supply and fix in repair of battery,12 V 130 AH, including testing for its proper functioning complete all as specified and directed by Engineer-in-charge. Note :- Battery shall be of original make only accepted No substitute of battery.

6

-

-

... More
Supply and fix in repair of battery,12 V 150 AH, including testing for its proper functioning complete all as specified and directed by Engineer-in-charge. Note :- Battery shall be of original make only accepted No substitute of battery.

4

-

-

... More
Supply and filling in sump / topping up engine oil, multi grade 15 W 40/ 20 W 40 in engine or relpacement of engine oil Make :- Indian oil / Hindusthan petrolium / BPCL/ Castrol/Shell complete all as specified and directed by Engineer-in-charge.

1085

-

-

... More
S& F Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 0.3 mtr long complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
S& F Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 1.50mtr long complete all as specified and directed by Engineer-in-charge.

7

-

-

... More
Supply and topping Premixed Coolent in sealed container for DG Set of various capacity complete all as specified and directed by Engineer-in-charge.

170

-

-

... More
Supply and fill/top up the distilled water best quality (01 ltr packing) suitable for lead acid battery, complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
S&F controller suitable for 200 KVA to 600 KVA DG set, CPCB -I/CPCB-II, slilent type as per existing complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
Dismantling of UNSV self starter of capacity 12/24 volts from engine and shifting to civil workshop for repair/overhauling of the self starter by rewinding of field coil, repair and rewinding of armature and fixing it to the existing place after repairing, complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
Supply and fixing contactor 4 pole 255 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
Supply and fixing contactor 4 pole 325 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
Repair & Maintenance of existing canopy of eco friendly DG Set of any capacity, cleaning of internal & external parts, tightening of loose parts, painting of rusted inside area, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations, Replacement/Welding of damaged MS hinges suitable for Canopy door etc complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
Supply & fix Hose pipe set & Clips of water / coolant cooled radiator system for following DG set:-

-

-

-

... More
a) 20/30/35/40 KVA DG Set

4

-

-

... More
b) 50/62.5/63 KVA DG Set

4

-

-

... More
c) 75/100 KVA DG Set

5

-

-

... More
d) 125/160 KVA DG Set

4

-

-

... More
e) 200/250 KVA DG Set

2

-

-

... More
f) 600 KVA DG Set

1

-

-

... More
Repairs of radiator assembly by dismantling from engine and removing the sediments and scales, corrosion etc by means of descaling chemical cleaning and high pressure water washing and air cleaning, gas welding / soldering with good quality material for stopping the leakage etc, re-assembling the same with new gaskets, fixing to the engine with hoses, clips complete to the entire satisfaction of engineer-in-charge as required for following DG Sets.

-

-

-

... More
a) 20/30/35/40 KVA DG Set

3

-

-

... More
b) 50/62.5/63 KVA DG Set

4

-

-

... More
c) 75/100 KVA DG Set

3

-

-

... More
d) 125/160 KVA DG Set

2

-

-

... More
e) 200/250/600 KVA DG Set

3

-

-

... More
S&F in repair, PCB assy complete with display and update software including wiring work suitable for DG Set of capacity 50 to 63 KVA complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
S&F in repair, PCB assy complete with display and update software including wring work suitable for DG Se of capacity 75 to 100 KVA complete all as specified and directed by Engineer-in-charge.

3

-

-

... More
S&F in repair, PCB assy complete with display and update software including wring work suitable for DG Se of capacity 125 to 250 KVA complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
S&F in repair, PCB assy complete with display and update software including wring work suitable for DG Se of capacity 600 KVA complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
M&L for servicing of alternator of any make suitable for DG set by opening the end cover, cleaning the dust and rust formed over the terminals, cleaning with CTC liquid, checking of diodes, winding, isolating transformer and AVR panel and applying Dr. beck paint for insulation improvement over the strips/ winding and drying till getting sasfactory insulation resistance complete, refixing the covers including testing complete all as specified and directed by Engineer-in-charge.

-

-

-

... More
a) 20/30/35/40 KVA DG Set

2

-

-

... More
b) 50/62.5/63 KVA DG Set

4

-

-

... More
c) 75/100 KVA DG Set

3

-

-

... More
d) 125/160 KVA DG Set

1

-

-

... More
e) 200/250 KVA DG Set

1

-

-

... More
M&L for calibrating of diesel engine by disconnecting, dismantling of FIP, injector nozzles including connected accessories and refixing after required repairs, etc. complete all as specified and directed by Engineer-in-charge. Notes: (i) Injector nozzle, plunger, delivery valves only if found unserviceable and are replaced for proper functioning, the same will be measured and paid separately under rspective items herein (ii) All any other items required for making the FIP serviceable shall be deemed to be included in the quoted rate

2

-

-

... More
a) Supply only injector nozzle suitable for 20/30/35/40 KVA DG set.

2

-

-

... More
b) Supply only injector nozzle suitable for 50/62.5/63 KVA DG set

2

-

-

... More
c) Supply only injector nozzle suitable for 75/100 KVA DG set

2

-

-

... More
d) Supply only injector nozzle suitable for 125/160 kVA DG set

2

-

-

... More
e) Supply only injector nozzle suitable for 200/250 kVA DG set

2

-

-

... More
f) Supply only injector nozzle suitable for 600 kVA DG set

1

-

-

... More
g) Supply only plunger suitable for 20/30/35/40 KVA DG set.

2

-

-

... More
h) Supply only plunger suitable for 50/62.5/63 KVA DG set

2

-

-

... More
j) Supply only plunger suitable for 75/100 KVA DG set

2

-

-

... More
k) Supply only plunger suitable for 125/160 KVA DG set

2

-

-

... More
l) Supply only plunger suitable for 200/250 KVA DG set

2

-

-

... More
m) Supply only plunger suitable for 600 KVA DG set

1

-

-

... More
n) Supply only delivery valves suitable for 20/30/35/40 KVA DG set.

2

-

-

... More
o) Supply only delivery valves suitable for 50/62.5/63 KVA DG set

2

-

-

... More
p) Supply only delivery valves suitable for 75/100 KVA DG set

2

-

-

... More
q) Supply only delivery valves suitable for 125/160 KVA DG set

2

-

-

... More
r) Supply only delivery valves suitable for 200/250 KVA DG set

2

-

-

... More
s) Supply only delivery valves suitable for 600 KVA DG set

1

-

-

... More
Supply and fixing miniature circuit breaker (MCB) of single pole 6-32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
Supplying, Fixing, jointing and testing OFF LOAD change over switch 4 pole, 415 volts of current rating 100 Amps. complete all as specified and directed by Engineer-in-charge.

3

-

-

... More
Supplying, Fixing, jointing and testing OFF LOAD change over switch 4 pole, 415 volts of current rating 200 Amps. complete all as specified and directed by Engineer-in-charge.

3

-

-

... More
Supplying, Fixing, jointing and testing OFF LOAD change over switch 4 pole, 415 volts of current rating 400 Amps. complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
M&L in repair Flexible rubber coupling star type alongwith accessories suitable for DG set of capacity 20 to 50 KVA complete all as specified and directed by Engineer-in-charge.

3

-

-

... More
M&L in repair Flexible rubber coupling star type alongwith accessories suitable for DG set of capacity 62.5 to 100 KVA complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
M&L for shifting of DG set of any capacity by means of dismantling and lifting and transportaion, including all required T&P such as lifting crane etc and transporting to plant and installation complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
M&L Earthing complete with galvanised steel earth plate electrode 60x 60cm x 6 mm thick buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to 32 x 6mm galvanised iron strip as earthing lead by means of bolts nuts washers, all as shown in electrical plate No 3 connected to earthing test pont all as specified or indicated including testing completion complete all as specified and directed by Engineer-in-charge. NOTE :- [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.

3

-

-

... More
Supply, laying XLPE insulated PVC FRLS, screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 4 core 70 Sq mm including taking out old un-serviceable cable complete all as specified and directed by Engineer-in-charge.

40

-

-

... More
M&L for cleaning and preparation of steel surfaces of existing dull painting of GEN SET outdoor type full body with complete assemblies etc. and applying two coats of synthetic enamelled paint (water resistant type) according to IS colour code apple green by spray machine including writting MES/SM No., in capital letters of suitable size on body for capacity of 20 KVA TO 50 KVA complete all as specified and directed by Engineer-in-charge. Note :- Cost of paint shall be deemed to included in unit quoted rate. (ii) Gen Set are fixed at different locations. Painting thereof shall be carried out after getting the permission of authorities. Tenderer shall keep this aspect while quoting the rates.

13

-

-

... More
All as per item No. 37.00 here-in-before but for capacity of 60 KVA TO 100 KVA

23

-

-

... More
All as per item No. 37.00 here-in-before but for capacity of 110 KVA TO 200 KVA

8

-

-

... More
All as per item No. 37.00 here-in-before but for capacity of 210 KVA TO 250 KVA

2

-

-

... More
All as per item No. 37.00 here-in-before but for capacity of 320 KVA TO 600 KVA

1

-

-

... More
Overhauling and serviceing commercial type washing machine steam heated front loading type upto 30 Kg capacity automatic type with all controls and electric motors, contactors,drives, controller, single phase preventor, MCBs, timers, NO/NC contacts, thermal overload relay, HRC fuse and along with same size for drying tumbler complete with induction motors complete with attending minor issues as below complete all as specified and directed by Engr-in-charge. (a) Accumulation of residual water in washing drum. (b) Leakage of compressed air in washing machine. (c) Unlocking of programming controller/display. (d) Fixing of vibration of washing machine. (e) water heating problem of washing machine. (f) Calibration of various programme as per the user requirement. Note:- Minor items required to replace to make machine serviceable shall be deemed to included in the quoted rate.

20

-

-

... More
Overhauling and serviceing commercial type drying tumbler steam heated front loading type upto 30 Kg capacity automatic type with all controls and electric motors, contactors,drives, controller, single phase preventor, MCBs, timers, NO/NC contacts, thermal overload relay, HRC fuse complete with induction motors complete with attending minor issues as below complete all as specified and directed by Engr-in-charge. (a) Leakage of compressed air in drying tumbler. (b) Unlocking of programming controller/display. (c) Fixing of vibration of drying tumbler. (d) Heating problem of drying tumbler. (e) Calibration of various programme as per the user requirement. Note:- Minor items required to replace to make machine serviceable shall be deemed to included in the quoted rate.

15

-

-

... More
S&F in repair, industrial washing machine microcontroller with relay card microprocessure based consists of water level controller for wash/rinse, digital temperature controller, automatic drain valve control, built in reversing timer and LCD display for clear visibility of status of the machine complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
S&F in repair, PCB controller with relay card for steam heated drying tumbler microprocessure based with built in reversing timer for forward and reverse control of motor, temperature controller, digital timer, user customizable programs for drying tumbler complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
S&F in repair, pneumatic operated single solenoid valve 220 volts with PU fittings including all accessories complete all as specified and directed by Engineer-in-charge. Make :- Model-TG2521-08 or equivalent make and model as approved by GE.

4

-

-

... More
S&F in repair, PU pipe 4mm including all accessories complete all as specified and directed by Engineer-in-charge.

100

-

-

... More
S&F in repair, 25mm water solenoid valve 220 volts including all accessories complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
S&F in repair, water level switch for industrial washing machine including all accessories complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
S&F in repair, pneumatic limit switch including all accessories complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
S&F in repair, drain valve for washing machine/Drying tumbler including all accessories complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
S&F in repair, door lock handle for washing machine/Drying tumbler including all accessories complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
S&F in repair, V- Belt SPA 1350 complete including all accessories complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
S&F in repair, V- Belt SPA 2120 complete including all accessories complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
S&F in repair, V- Belt SPA 1800 complete including all accessories complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
S&F in repair, V- Belt SPA 2300 complete including all accessories complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
S&F in repair, V- Belt SPA 2150 complete including all accessories complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
S&F in repair, V- Belt SPA 1400 complete including all accessories complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
S&F in repair, vlt automation drive 7.5 to 10HP complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
Overall overhauling, maintenance and Serviceing Air compressor horizontal single acting 09 Kg / Sqcm, with three phase 02/03 HP motor complete including all the minor items tobe used for this purpose will be considered under quoted rate complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
S&F in repair, copper tube, aluminium fin Steam Radiator with heat exchanger in low temperature for drying tumbler of 15/20/30 kg capacity as per sample complete including all accessories complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
NOTE for Item No 42 to 61:- (a) Spares required for the above maintenance shall be measured & paid as Supply only under appropriate items of Schedule 'A'. where not mentioned the quoted rates to be considered accordingly. (b) Replacement of Control panel with wiring and connections, actuators, relays,etc, replacement of any damaged or corroded parts,transformer, diode, springs, contactor, coupling, all mechanical parts, etc complete in all respect is deemed to be inclusive in the rate quoted. (c) The maintenance and overhauling will be done by OEM only and report will be submitted to EIC. (d) The Contractor and OEM shall be responsible for defect liability period of similar nature work for any maintenance required after servicing. No extra charge will be applicable for it.

-

-

-

... More
Taking down induction motor from washing machine/drying tumbler/air compressor after disconnecting the electrical connection complete of following sizes all as directed by Engineer-in-charge.

-

-

-

... More
(a) 0.5 HP

4

-

-

... More
(b) 1 HP

4

-

-

... More
(c) 3 HP

1

-

-

... More
M&L for induction motor of washing machine/drying tumbler/air compressor after disconnecting the electrical connection and transporting to & from workshop for cutting (i.e machining,work, welding, grinding, turning & polishing, lathe work, filler work etc.) & taking burn out copper winding complete and cleaning properly. Rewinding the motor with same gauge and same turn ratio for proper RPM, best quality copper enamelled winding wire and packing properly with packing materials, varnishings, drying & replacing wornout bearing/terminal plate, reassembling, fixing in original position, testing & commissioning complete of following sizes all as directed by Engineer-in-charge.

-

-

-

... More
(a) 0.5 HP

4

-

-

... More
(b) 1 HP

4

-

-

... More
(c) 3 HP

1

-

-

... More
Fixing only induction motor in washing machine/drying tumbler/air compressor after machining work and rewinding the motor in original position, testing & commissioning complete of following sizes all as directed by Engineer-in-charge. Note :- (i) Induction motor obtained from Ser item No. 21.00 shall be re-fixed in its possion after replacement of spares. (ii) This item will not be applicable for induction motors considered under Ser item No. 70.00.

-

-

-

... More
(a) 0.5 HP

4

-

-

... More
(b) 1 HP

4

-

-

... More
(c) 3 HP

1

-

-

... More
Supply and fix in repair of bearing of same size as existing suitable for motor including all fiiting, fixtures, etc complete as directed by Engr-in-charge as following : -

-

-

-

... More
(a) 0.5 HP

4

-

-

... More
(b) 1 HP

4

-

-

... More
(c) 3 HP

4

-

-

... More
Supply and fix in repair of single phase preventor RS P-2 type suitable for 415V AC, 50 Hz complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
Supply and fix in repair of 3 pole AC contactors, rated for 240V AC suitable for 32 Amp, 7.5 kw, 50 Hz complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
Supply and fix in repair of thermal overload relay suitable for 10A, 240V AC, 50 Hz complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
Supply and fix in repair of DOL starter suitable for compressor upto 3 HP MK1 type incl. indicating push button,etc. complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
Supply and fix cable PVC isulated and PVC sheathed 1100 volt grade copper conductor 2.5 Sqmm 4 core complete including taking down existing cable complete all as specified and directed by Engineer-in-charge.

80

-

-

... More
M&L dewatering, cleaning of sewage water collection U/G tanks with high pressure jet to remove all mosses, algae and dirt and removal of dirty water along with sludge machines/industrial vacum cleaners and disposal of the same to a safe distance and marking the date of cleaning by using synthetic enamel paint in white colour over black background and letters of height 40 mm height and 30 mm width complete all as directed for the following sizes:-

-

-

-

... More
(a) 15 x 10 x 2 m

3

-

-

... More
(b) 20 x 10 x 2 m

3

-

-

... More
M&L dewatering, cleaning of sewage water collection tank size of 50000 Gallons U/G tanks with high pressure jet to remove all mosses, algae and dirt and removal of dirty water along with sludge machines/industrial vacum cleaners and disposal of the same to a safe distance and marking the date of cleaning by using synthetic enamel paint in white colour over black background and letters of height 40 mm height and 30 mm width complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
M&L dewatering, cleaning of sewage collection U/G tanks (approx depth of tank around 10 m of capacity 1.4 MLD) with high pressure jet to remove all mosses, algae and dirt and removal of dirty water along with sludge machines/industrial vacum cleaners and disposal of the same to a safe distance and marking the date of cleaning by using synthetic enamel paint in white colour over black background and letters of height 40 mm height and 30 mm width complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
M&L for cleaning of STP and surrounding area by surface excavation upto 10 cm depth incl removing shrubs, grass, miniplants and other unwanted materials and levelling complete in soft/loose soil complete all as specified and directed by Engineer-in-charge.

10000

-

-

... More
Supply, lay, test connecting and commissioning armoured underground cable LT 1100 volt grade heavy duty XLPE 25 Sqmm 3.5 core insulated with aluminum stranded conductor complete laid in trenches / duct/ drawn through pipes with suitable size cable glands criping type cable lugs etc including taking up/down existing unserviceable cable complete all as specified and directed by Engineer-in-charge.

40

-

-

... More
M&L for lifting the Non-clog sewage pumps of size 10 HP from the sump and placing them safely nearby and again lifting the sewage pumps after required servicing and place them as their respective places with all proper attachments, nuts,bolts,etc and including testing the same for same efficiency of pumps complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
M&L for lifting the Non-clog sewage pumps of size 7.5 HP from the sump and placing them safely nearby and again lifting the sewage pumps after required servicing and place them as their respective places with all proper attachments, nuts,bolts,etc and including testing the same for same efficiency of pumps complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
Dismantling & taking down centrifugal/monoblock pump set from plate form and disconnecting suction & delivery pipe line & electrical connections, transport the same to workshop for repair(i.e machining,work, welding, grinding, turning & polishing etc.) and after repairing transporting the pump set from workshop to site, installation at site connecting suction & delivery pipe and electrical connection complete including taking down all as directed by Engineer-in-charge for following pumps capacity . NOTE:-(i) The rate is deemed to be included the cost of providing foundation nuts, bolts & washers gland packing, greasing, oiling and oil sheet gasket. (ii) The spare parts will be measured and paid separately under relevent items of Sch 'A' as supply only.

-

-

-

... More
(a) 20 HP

1

-

-

... More
(b) 5 HP

1

-

-

... More
Supply only following parts for item No. 106.00 of 20 HP capacity centrifugal pump sets.

-

-

-

... More
(a) Impeller

1

-

-

... More
(b) Casing Ring

1

-

-

... More
( c) Impeller ring brass nut

1

-

-

... More
(d) Impeller key

1

-

-

... More
( e) Coupling key

1

-

-

... More
(f) Coupling rubber bushes/ Tyre coupling

4

-

-

... More
(g) Shaft sleeve (Steel)

2

-

-

... More
(h) Bearing

4

-

-

... More
(j) Brass Bush

2

-

-

... More
(k) Shaft

1

-

-

... More
(l) MS coupling (Beam, Jaw, Gear any type for both Pump and motor)

1

-

-

... More
(m) Gland cap CI

2

-

-

... More
(n) Gland bolt/ nut

4

-

-

... More
Supply & fix against Item No 48 above the following spares parts suitable for 5 HP Pump Set 3 Phase capacity monoblock pump sets complete all as directed by Engr-in-charge.

-

-

-

... More
(a) CI Impeller

1

-

-

... More
(b) Impeller nut GM

2

-

-

... More
( c) key for Impeller MS

1

-

-

... More
(d) Front bearing

2

-

-

... More
( e) CI front inner cap.

2

-

-

... More
(f) CI rear inner cap.

2

-

-

... More
(g) Rear bearing

2

-

-

... More
(h) CI rear outer cap.

1

-

-

... More
(j) Terminal board bakelite

2

-

-

... More
(k) Shaft

1

-

-

... More
Taking down the motor from base plate/ pump after disconnecting the electrical connection and transporting to & from workshop for cutting & taking burn out copper winding complete and cleaning properly. Rewinding the motor with same gauge, best quality copper enamelled winding wire and packing properly with packing materials, varnishings, drying & replacing wornout bearing/terminal plate, reassembling, fixing in original position, testing & commissioning complete of following sizes all as directed by Engineer-in-charge

-

-

-

... More
(a) 20 HP

1

-

-

... More
(b) 05 HP

1

-

-

... More
Supply and fix in repairs front/rear ends bearing for 20 HP of same size as existing suitable for motor incl all fiiting and fixtures as directed by Engr-in-charge

2

-

-

... More
Dismantling & taking down Non clog pump set from platform and disconnecting suction & delivery pipe line & electrical connections, transport the same to workshop for repair(i.e machining,work, welding, grinding, turning & polishing, lathe work, filler work etc. complete as required on site) and after repairing transporting the pump set from workshop to site, installation at site connecting suction & delivery pipe and electrical connection complete all as directed by Engineer-in-charge for following pumps capacity NOTE:-(i) The rate is deemed to be included the cost of providing foundation nuts, bolts & washers gland packing, greasing, oiling and oil sheet gasket. (ii) The spare parts will be measured and paid separately under relevent items of Sch 'A' . No extra payment will be made to the contractor for any additional requirement for fixing/ reinstalling the pump motor set.(iii) Gland packing, greasing and oiling should be changed at the time of repairs.

-

-

-

... More
( a) 10 HP

2

-

-

... More
( b) 7.5 HP

4

-

-

... More
Supply & fix against Item No 84 above suitable for 10 HP capacity Non clog pump sets.

-

-

-

... More
(a) CI Impeller

4

-

-

... More
(b) Casing Ring

6

-

-

... More
( c) Impeller ring brass nut

6

-

-

... More
(d) Impeller key

6

-

-

... More
( e) Coupling key

6

-

-

... More
(f) Coupling rubber bushes/ Tyre coupling

6

-

-

... More
(g) Shaft sleeve (Steel)

6

-

-

... More
(h) Bearing

12

-

-

... More
(j) Brass Bush

6

-

-

... More
(k) Shaft

4

-

-

... More
(l) MS coupling (Beam, Jaw, Gear any type for both Pump and motor)

2

-

-

... More
(m) Gland cap CI

8

-

-

... More
(n) Gland bolt/ nut

16

-

-

... More
Supply & fix against Item No 84 above suitable for 7.5 HP capacity Non clog pump sets.

-

-

-

... More
(a) CI Impeller

2

-

-

... More
(b) Casing Ring

2

-

-

... More
( c) Impeller ring brass nut

2

-

-

... More
(d) Impeller key

2

-

-

... More
( e) Coupling key

2

-

-

... More
(f) Coupling rubber bushes/ Tyre coupling

2

-

-

... More
(g) Shaft sleeve (Steel)

2

-

-

... More
(h) Bearing

4

-

-

... More
(j) Brass Bush

2

-

-

... More
(k) Shaft

1

-

-

... More
(l) MS coupling (Beam, Jaw, Gear any type for both Pump and motor)

1

-

-

... More
(m) Gland cap CI

4

-

-

... More
(n) Gland bolt/ nut

8

-

-

... More
Taking down the motor from base plate/ pump after disconnecting the electrical connection and transporting to & from workshop for cutting (i.e machining,work, welding, grinding, turning & polishing, lathe work, filler work etc.) & taking burn out copper winding complete and cleaning properly. Rewinding the motor with same gauge and same turn ratio for proper RPM, best quality copper enamelled winding wire and packing properly with packing materials, varnishings, drying & replacing wornout bearing/terminal plate, reassembling, fixing in original position, testing & commissioning complete of following sizes all as directed by Engineer-in-charge (Note : Supply only bearings and terminal plates will be measured and paid separetely under respective item of this schedule)

-

-

-

... More
(a) 10 HP

1

-

-

... More
(b) 7.5 HP

2

-

-

... More
Supply and fix in repairs motor cooling fan of same size as existing suitable for motor including all fiiting, fixtures etc as directed by Engr-in-charge as following : -

-

-

-

... More
(a) 10 HP

1

-

-

... More
(b) 7.5 HP

2

-

-

... More
Supply and fix in repairs front / rear ends bearing of same size as existing suitable for motor including all fiiting, fixtures etc (including taking out motor if not in repair) as directed by Engr-in-charge as following : -

-

-

-

... More
(a) 10 HP

4

-

-

... More
(b) 7.5 HP

4

-

-

... More
Material and labour for dismantling the Blower set (Everest Blower- Twin Lobe Blower, Model-EB6HPM) complete including taking down of up to 15 HP and carrying out repair/replacement for defective parts such as bearing, shaft sleeves, gland plate, impeller, including replacement of worn out nuts, bolts, filling of pump oil heavy grade (Super-90) , greasing of bearing, replacement of gaskit, mechanical seal, rotor job, replacement of belts, etc etc complete including taking down all as directed and reassmebling, testing & commissioning complete. Note:- 1. Rates for making arrangement for lifting up blower motor shall be deemed in quoted rates. 2. Once the motor set repaired, the contractor shall by default get the bearing, and other necessary parts changed and shall remain responsible for proper functioning of motor pump for complete including taking down one year from the date of repair. No extra cost will be paid to the contractor for any other repair work if at all required within this duration of one year. 3. Item Rate include alignment of shaft, servicing of motar, servicing of blower, servicing of gear box, grease required at job work include in unit rate.

2

-

-

... More
Material and labour for dismantling the sewage suction set complete including taking down of up to 05 HP and carrying out repair/replacement for defective parts such as bearing, shaft sleeves, gland plate, impeller, including replacement of worn out nuts, bolts, filling of pump oil heavy grade, greasing of bearing, replacement of gaskit, mechanical seal, rotor job, replacement of belts,etc etc complete including taking down all as directed and reassmebling, testing & commissioning complete. Note:- 1. Rates for making arrangement for lifting up blower motor shall be deemed in quoted rates. 2. Once the motor set repaired, the contractor shall by default get the bearing, and other necessary parts changed and shall remain responsible for proper functioning of motor pump for complete including taking down one year from the date of repair. No extra cost will be paid to the contractor for any other repair work if at all required within this duration of one year. 3. Item rate include alignment of shaft , servicing of motar, servicing of blower, servicing of gear box, grease required at job work include in unit rate.

2

-

-

... More
Supply and float suspended plastic carriers (as available on site) with large protected surface areas for the growth of bacteria and proper decomposition of sludge in all three tanks complete all as specified and directed by Engineer-in-charge.

100

-

-

... More
M & L for scrapping/cleaning of outer surfaces of pipes of any size and any type and headers and spray painting with two coats of best qualitiy MS sythetic anticorrosive bitumin paint over one coat of red oxide primer (colour as per colour code) complete including marking and writing details complete all as specified and directed by Engineer-in-charge.

100

-

-

... More
S&F in repair submersible cable PVC insulated and PVC sheathed industrial 1100 Volts grade multistranded copper conductor of size 10 Sqmm flat 3 Core complete all as specified and directed by Engineer-in-charge.

80

-

-

... More
S&F butterfly valve, high pressure with crutch or butterfly handle for iron pipe or for unions (P.N 1.6) of follwing sizes complete including taking down complete all as specified and directed by Engineer-in-charge. (Note:- The contractor shall bring the valves as per site requirement and site dimensions taking prior permission from Engineer-in-charge.

-

-

-

... More
(a) 40 mm bore.

4

-

-

... More
(b) 80 mm bore.

4

-

-

... More
(c) 100 mm bore.

4

-

-

... More
M&L for painting of following capacity monoblock/ centrifugal from foundation (base plate to be scratched and painted) painting (all as per colour code specified) by synthetic enameled paint one coat after cleaning and preparing surface for painting, reinstalling and testing complete at site on full load complete all as specified and directed by Engineer-in-charge.

-

-

-

... More
(a) 05 HP

3

-

-

... More
(b) 20 HP

4

-

-

... More
S&F in replacement of automatic star delta starter suitable for following size of motors and pumps including timer indicating push button etc complete all as specified and directed by Engineer-in-charge.

-

-

-

... More
(a) 7.5 HP

1

-

-

... More
(b) 10 HP

2

-

-

... More
(c ) 20 HP

1

-

-

... More
S&F in replacement of overload relay complete all same as per existing capacity for the following:-

-

-

-

... More
(a) 7.5 HP

1

-

-

... More
(b) 10 HP

2

-

-

... More
(c ) 20 HP

1

-

-

... More
Supply and fixing the following items:-

-

-

-

... More
(a) MCCB, 100 Amps, 4 pole, 10 KA, 415 volt

2

-

-

... More
(b) MCCB, 250 Amps, 4 pole, 10 KA, 415 volt

1

-

-

... More
(c) MCCB, 160 Amps, 4 pole, 10 KA, 415 volt

1

-

-

... More
(d) MCB 63 Amps, 4 pole, 16 KA, 415 volt

2

-

-

... More
(e) MCB TPN 32 Amps, 4 pole, 10 KA, 415 volt

6

-

-

... More
S&F in repair MS pipe 100mm dia 'C' class including testing & commissioning complete all as specified and dirercted by Engineer-in-charge.

30

-

-

... More
S&F in repair MS pipe 80 mm dia 'C' class including testing & commissioning complete all as specified and dirercted by Engineer-in-charge.

30

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.