Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687503_1Bid Award Id
ViewTender No
89024/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply and fixing in replacmnent of BATTERY 12 Volt 150 AH capicity make :exide,amaron
8
-
-
... More
Supply and fixing in replacment of BATTERY 12 Volt 100 AH capicity make :exide,amaron
8
-
-
... More
Supply and fixing in repair of MCCBs Thermal Magnetic type .make :Legrand,L&T,ABB
(a) MCCB 400 Amp 4 pole 415 V
1
-
-
... More
(b) MCCB 250 Amp 4 pole 415 V
2
-
-
... More
(c) MCCB 200 Amp 4 pole 415 V
2
-
-
... More
(d) MCCB 160 Amp 4 pole 415 V
2
-
-
... More
(e) MCCB 125 Amp 4 pole 415 V
2
-
-
... More
(f) MCCB 100 Amp 4 pole 415 V
2
-
-
... More
Supply & Fixing in repair of Four Pole Contactor 240 AC, 2 NO+NC, or 01 NO NC Make = Schneider/ABB/Legrand/C&S
(a) 100 Amp
2
-
-
... More
(b) 200 Amp
3
-
-
... More
(C) 160 Amps
3
-
-
... More
(d) 250 Amps
4
-
-
... More
(e) 300 Amps
2
-
-
... More
Supply & Fixing in repair of Four Pole Contactor coil 240 V AC Make = GE/Schneider/ABB/Legrand/L&T/TC
(a) 100 Amp
2
-
-
... More
(b) 200 Amp
4
-
-
... More
(C) 160 Amps
2
-
-
... More
(d) 400 Amps
2
-
-
... More
(e) 250 Amps
2
-
-
... More
(f) 600Amps
1
-
-
... More
Supply & Fixing in repair of Autocut Electrical Battery Charger Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Type Rectifier Unit etc.
Make = Teknika/ NPP/DIEF (a) Battary Charger 12V DC, 10 Amp.
8
-
-
... More
(b) Battary Charger 24V DC, 10 Amp.
6
-
-
... More
Supply & Fixing in repair of Voltage Monitor Relay, 3 Phase AC, 110/415VAC Setting 75-100/300-400V, Trip Time 0-10 Sec. Make =Teknika,L&T,vinilec
10
-
-
... More
Replacement of indicating lamp set RYB for phase indication operating 240 volt 50 HZ AC with new one LED panel mounting type complete to match existing one all as directed Make : L&T / C&S / Siemens / ABB
15
-
-
... More
Supply & Fixing in repair of Timer AC/DC on Delay, AC 110/220VAC DC 24/12, 1-10, 3-30, 10-100 Sec. Make =Teknika,L&T,vinilec
10
-
-
... More
Supply & Fixing in repair of Engine Start Relay, 12/24 VDC, For Gensets 3 Cranks No & Off 0-30 Sec Each Setable. Make =Teknika,L&T,vinilec
5
-
-
... More
Supply & Fixing in repair of Earth Fault Relay, Non Direction, Defite Time & Current adustable Setting 0.4-4A/0.2-2A, Time 0-10 Sec.Make =Teknika,L&T,vinilec
2
-
-
... More
Supply & Fixing in repair of 12x1.5 Sqmm Multistrand Copper Conductor Control Cable for DG Set to AMF Panel.
100
-
-
... More
Supply & Fixing in repair of Single Phase Preventer in AMF Panel. Make =Teknika,L&T,vinilec
10
-
-
... More
Supply & Fixing in repair of DC 12/24V Solenoid Coil (4 ST SWITCH) suitable for DG Set
15
-
-
... More
Supply & Fixing in repair of Microprocessor/Alfa-Numeric Based DG SET PLC FOR DG SET (PS 500 unit for CUMMINS)
4
-
-
... More
Supply & Fixing in repair of Microprocessor/Alfa-Numeric Based DG SET PLC FOR DG SET (kirloskar 320 KVA)
1
-
-
... More
Supply & Fixing in repair of Microprocessor/Alfa-Numeric Based DG SET speed control unit for DG SET as directed
1
-
-
... More
Supply and filling Premixed coolent.MAKE VOLVOLINE ,KOEL, FLEETGUARD
300
-
-
... More
Supply and filling in sump/topping up engine oil, multi grade 15w40 in engine or relpacement of engine oil. Make :-volvoline or equivellent
400
-
-
... More
Repalcement of DG set self of 12 V capacity as existing on site upto 125 KVA DG set Make Lucas ,Bosch as directed
2
-
-
... More
Repalcement of DG set self of 24 V capacity as existing on site upto 250 KVA DG set Make Lucas ,Bosch as directed
2
-
-
... More
Supply, installation, testing and commissioning in repairs of AMF Panel outdoor type, 160 KVA DG Set with alluminium busbar of capacity 400 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 250 Amps consisting the following:-(INST LAB ,BASE OPS)
INCOMING from 160 KVA
(i) MCCB 250 Amp thermal megnetic release type FP 25 KA - 01 No (ii) Spreaders for 400 Amps FP - 01 Set
(iii) Extended Rotary handle 250 Amps FP - 01 No
(iv) Power Contactor 200 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No
(vi) C.T. 200/5A CL-1.0 10 VA - 03 Nos
(vii) Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No
(viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve - 03 Nos
(x) VMR - 01 No
(xi) In built on load change over switch 250A for bypassing of AMF panel - 02 No
Outgoing
(i) MCCB 250 Amp thermal megnetic release type FP 25 KA - 01 No
(ii) Power Contactor 200 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF relay - 06 Nos
(iv) SMPS 12V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital Amp meter 24V, DC - 01 No
(vii) Digital Volt meter 24V, DC - 01 No
(viii) Control MCB 6A SP 10 KA C Curve - 03 Nos
(ix) Hooter - 01 No
(x) PROCOM UNIT (DGC6D) FOR control - 01 No
(xi)Extended Rotary handle 250 Amps FP - 01 No
1
-
-
... More
Supply, installation, testing and commissioning in repairs of AMF Panel outdoor type, 125 KVA DG Set with alluminium busbar of capacity 400 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 250 Amps consisting the following:-(INST LAB ,BASE OPS)
INCOMING from 125 KVA
(i) MCCB 250 Amp thermal megnetic release type FP 25 KA - 01 No (ii) Spreaders for 400 Amps FP - 01 Set
(iii) Extended Rotary handle 250 Amps FP - 01 No
(iv) Power Contactor 200 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No
(vi) C.T. 200/5A CL-1.0 10 VA - 03 Nos
(vii) Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No
(viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve - 03 Nos
(x) VMR - 01 No
(xi) In built on load change over switch 250A for bypassing of AMF panel - 02 No
Outgoing
(i) MCCB 250 Amp thermal megnetic release type FP 25 KA - 01 No
(ii) Power Contactor 200 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF relay - 06 Nos
(iv) SMPS 12V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital Amp meter 24V, DC - 01 No
(vii) Digital Volt meter 24V, DC - 01 No
(viii) Control MCB 6A SP 10 KA C Curve - 03 Nos
(ix) Hooter - 01 No
(x) PROCOM UNIT (DGC6D) FOR control - 01 No
(xi)Extended Rotary handle 250 Amps FP - 01 No
3
-
-
... More
Supply, installation, testing and commissioning in repairs of AMF Panel outdoor type, 100 kva DG Set with alluminium busbar of capacity 300 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 250 Amps consisting the following:-( 32 SQN,10SQN)
INCOMING from 100 KVA
(i) MCCB 200 Amp thermal megnetic release type FP 25 KA - 01 No (ii) Spreaders for 400 Amps FP - 01 Set
(iii) Extended Rotary handle 200 Amps FP - 01 No
(iv) Power Contactor 200 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No
(vi) C.T. 200/5A CL-1.0 10 VA - 03 Nos
(vii) Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No
(viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve - 03 Nos
(x) VMR - 01 No
(xi) In built on load change over switch 250A for bypassing of AMF panel - 02 No
Outgoing
(i) MCCB 200 Amp thermal megnetic release type FP 25 KA - 01 No
(ii) Power Contactor 200 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF relay - 06 Nos
(iv) SMPS 12V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital Amp meter 24V, DC - 01 No
(vii) Digital Volt meter 24V, DC - 01 No
(viii) Control MCB 6A SP 10 KA C Curve - 03 Nos
(ix) Hooter - 01 No
(x) PROCOM UNIT (DGC6D) FOR control - 01 No
(xi)Extended Rotary handle 200 Amps FP - 01 No
3
-
-
... More
Supply, installation, testing and commissioning in repairs of AMF Panel outdoor type, 62.5 kva DG Set with alluminium busbar of capacity 250 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 150 Amps consisting the following:-(ER 02, DWR )
INCOMING from 62.5 KVA
(i) MCCB 150 Amp thermal megnetic release type FP 16 KA - 01 No (ii) Spreaders for 250 Amps FP - 01 Set
(iii) Extended Rotary handle 250 Amps FP - 01 No
(iv) Power Contactor 150 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No
(vi) C.T. 200/5A CL-1.0 10 VA - 03 Nos
(vii) Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No
(viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve - 03 Nos
(x) VMR - 01 No
(xi) In built on load change over switch 200A for bypassing of AMF panel - 02 No Outgoing
(i) MCCB 150 Amp thermal megnetic release type FP 16 KA - 01 No
(ii) Power Contactor 150 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF relay - 06 Nos
(iv) SMPS 12V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital Amp meter 24V, DC - 01 No
(vii) Digital Volt meter 24V, DC - 01 No
(viii) Control MCB 6A SP 10 KA C Curve - 03 Nos
(ix) Hooter - 01 No
(x) PROCOM UNIT (DGC6D) FOR control - 01 No
(xi)Extended Rotary handle 250 Amps FP - 01 No
3
-
-
... More
Supply, installation, testing and commissioning in repair of AMF Panel outdoor type, 30 kva DG Set with alluminium busbar of capacity 125 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 100 Amps consisting the following:-(SALAWAS ATC NO 01 AND NO 02)
INCOMING from 30 KVA
(i) MCCB 100 Amp thermal megnetic release type FP 10 KA - 01 No (ii) Spreaders for 100 Amps FP - 01 Set
(iii) Extended Rotary handle 100 Amps FP - 01 No
(iv) Power Contactor 100 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No
(vi) C.T. 100/5A CL-1.0 10 VA - 03 Nos
(vii) Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No
(viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve - 03 Nos
(x) VMR - 01 No
(xi) In built on load change over switch 100A for bypassing of AMF panel - 02 No Outgoing
(i) MCCB 100 Amp thermal megnetic release type FP 10 KA - 01 No
(ii) Power Contactor 100 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF relay - 06 Nos
(iv) SMPS 12V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital Amp meter 24V, DC - 01 No
(vii) Digital Volt meter 24V, DC - 01 No
(viii) Control MCB 6A SP 10 KA C Curve - 03 Nos
(ix) Hooter - 01 No
(x) PROCOM UNIT (DGC6D) FOR control - 01 No
(xi)Extended Rotary handle 100 Amps FP - 01 No
2
-
-
... More
Opening of AMF Panel, Cleaning of dust using blower & cleaning agents. Checking/Detecting, Removal of Faults, Re-wiring of old u/s wiring & Testing of Control Wiring complete as reqd and closing of AMF Panel after replacement of above u/s parts and testing on completion of job on existing load,cleaning and removing the sludge from DG setetc. as specified & directed by Engineer-in-Charge.
60
-
-
... More
M&L in replacement for earthing complete with copper earth plate electrode 60cmx60cmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe upto 7.5m
30
-
-
... More
Repair and maint of AMF panel including,painting of panel dual coat of enamel paint insulation of bus baars ,welding of AMF panel to its angle iron frame,hinjes replacement,locking arrangement and all other small maint work as directed by engineer in charge
30
-
-
... More
Daily inspection and checking the serviceability of DG set includs checking of engine oil ,fuel ,coolent ,battery terminal on priority basis as directed by engineer in charge