Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Oct 2023
Closing Date6 Nov 2023
Tender Amount₹ 24,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for renewal of unserviceable mechanical oil seal of compressor at coupling end including testing and commissioning etc. complete all as specified & as directed. Note :-Gas/Oil required to be changed after renewal of mechanical oil seal will be measured and paid separately in respective items of BOQ.

5

-

-

... More
Dismantling, opening, rewinding and refixing 3 phase, 440V, 50 Hz induction motors with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint, necessary mechnical works for shaft /bearing housing, renewal of DE and NDE beaings, transportation from installation to workshop & back, connecting testing and commissioning at site for satisfactorily operation as required for : (i) 3 to 7.5 HP.

5

-

-

... More
(ii) 10 HP Motor.

8

-

-

... More
(iii) 12.5 to 20 HP Motor.

7

-

-

... More
(iv) 100 HP Motor.

2

-

-

... More
Dismantling and taking out defective monoblock pump of capacity 52 LPS. make- Kirloskar from foundation and shifting it to workshop for repair/replacement of impellers, beanings, seals etc. Refitting at foundation after repair testing and commissioning complete to the entire satisfaction etc. complete all as specified & as directed.

2

-

-

... More
Dismantling and taking out defective centrifugal pump of capacity 123 cum /hr (Make - kirloskar) from foundation and shifting it to workshop for repair/ replacement of impellers, bearings, seals etc, Re-fitting at foundation after repair testing and commissioning complete to the entire satification etc. complete all as specified & as directed.

2

-

-

... More
M&L for checking/ repair/ calibration of microm adjuster of compressor control panel, model-VLRP single, type dluxe (Make- Softhard intelli Sys)

5

-

-

... More
S&F in repair microprocessor based controller of compressor control panel of 80 TR central AC plant with internal wiring and connections. Make:- Voltas/ Softhard Intelli/ Seimens as approved by GE

2

-

-

... More
S&F in repair PVC water tank heavy duty of capacity 5000 ltrs with CI strip ground around it to avoid bulging/ deformation of tank as per existing including plumbing work as reqired. (Make- Sintex/polycon as approved by GE)

1

-

-

... More
M&L for refrigerant oil for compressor. Make- HPCL- N 68/ Indian Oil- Servo-Friz/ BPCL-Freezol 68 as approved by GE

200

-

-

... More
S&F in repair contactor of LT panel of AC plant, MNX 18, AC supply, 230V, 50HZ, 4 Pole etc. complete all as specified & as directed. Make- L&T /Siemens /ABB as approved by GE

25

-

-

... More
S&F in repair contactor of LT panel of AC plant, MNX 22, AC supply, 230V, 50HZ , 3 Pole etc. complete all as specified & as directed. Make- L&T /Siemens /ABB as approved by GE

20

-

-

... More
S&F in repair contactor of LT panel of AC plant, MNX 25, AC supply, 230V, 50HZ , 3 Pole. Make- L&T /Siemens /ABB as approved by GE

20

-

-

... More
S&F in repair contactor of LT panel of AC plant, MNX 32, AC supply, 230V, 50HZ , 3 Pole. Make- L&T /Siemens /ABB as approved by GE

25

-

-

... More
S&F in repair front mounting add-on aux, contact block for contactor of LT panel of AC Plant, MNX - A1 or MNX-A2, AC, 415V, 50 Hz. Make:- L&T/Siemens/ABB as approved by GE

25

-

-

... More
S&F in repair single phasing preventor of the LT panel of AC plant, 3 phase AC, 415 volt, 50 Hz. Make:- L&T/Minilec as approved by GE

25

-

-

... More
S&F in repair MCB TP, 63 amps, AC, 10 KA, 'C' series of the LT panel of AC plant. Make- Legrand/ Schneider/Hagar as approved by GE

10

-

-

... More
S&F in repair MCB TP, 40 amps, AC, 10 KA, 'C' series of the LT panel of AC plant. Make- Legrand/ Schneider/Hagar as approved by GE

10

-

-

... More
S&F in repair contactor of compressor control panel AC,415 V, 50 Hz, 3 Phase, Model 3TF47. Make- L&T/Siemens/ ABB as approved by GE

5

-

-

... More
S&F in repair contactor of compressor control panel, AC, 415 V, 50HZ, 3 phase, Model 3TF49. Make- L&T/ Siemens/ ABB as approved by GE

5

-

-

... More
S&F in repair thermal overload relay of range 9-15A, 14-23A, type direct mounting on MNX, for control panel. Make- L&T /Siemens/BB as approved by GE

25

-

-

... More
S&F in repair contactor of compressor control panel, MNX 140, 3 Phase AC, 415V, 50Hz etc. complete all as specified & as directed. Make- L&T/Siemens / ABB as approved.

5

-

-

... More
S&F in repair magnetic solenoid coil, 220 volts, AC supply as per existing etc. complete all as specified & as directed.

5

-

-

... More
S&F in repair transducer PT3-30 Bar of compressor with horness as per existing etc. complete all as specified & as directed.

5

-

-

... More
S&F in repair digital timer of compressor control panle, time range 3-60 secs, 24/200-240V, 50HZ as per existing etc. complete all as specified & as directed.

5

-

-

... More
M&L for filling of refrigerant gas R-407 for central AC plant in topping up during servicing / maintenance etc. complete all as specified & as directed.

550

-

-

... More
S&F in repair rubber coupling of motor and compressor etc. complete all as specified & as directed.

20

-

-

... More
S&F in repair V belts for AHU motors of existing size and type etc. complete all as specified & as directed.

30

-

-

... More
S&F in repair heating elecments of 2.0 KW capacity of lengths from 1.5 to 2.5 ft as per site requirement etc. complete all as specified & as directed.

40

-

-

... More
S&F in repair heating elecments of 3.0 KW capacity of lengths from 1.5 to 2.5 ft as per site requirement etc. complete all as specified & as directed.

40

-

-

... More
S&F in repair phase indicating lamps LED type with the colour code as per existing etc. complete all as specified & as directed.

12

-

-

... More
S&F in repair water pressure indicating gauge fitted in water circulation circuit minimum range 0 to 7 kg/sqcm etc. complete all as specified & as directed. Make- IEBIG/H-Guru/ Gluck as approved by GE

10

-

-

... More
S&F in repair water temperature gauge fitted in water circulation circuit minimum range 10 to 50 degree centigrade. Make -IEBIG/ H-Guru/ Gluck as approved by GE

10

-

-

... More
S&F in repair high flow HEPA filter, box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13, capacity 2000 CFM of size 610mm x 610mm x 305mm etc. complete all as specified & as directed. Make : Thermadyne/ Puromatic /Primide /Dyna as approved by GE

4

-

-

... More
S&F in repair high flow HEPA filter box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13, capacity 1000 CFM of size 610mm x 305mm x 305mm etc. complete all as specified & as directed. Make : Thermadyne/ Puromatic /Primide /Dyna as approved by GE

2

-

-

... More
S&F in repair high flow HEPA filter, box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13 and of 1000 CFM of size 305mm x 610mmx305mm etc. complete all as specified & as directed. Make : Thermadyne/ Puromatic /Primide /Dyna as approved by GE

2

-

-

... More
S&F in repair high flow HEPA filter box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13 and of 500 CFM of size 305mm x 305mmx305mm. Make : Thermadyne/ Puromatic /Primide /Dyna as approved by GE

1

-

-

... More
S&F in repair FINE fiter, flange type efficiency 99.00% down to 5.0 micron and EU 5 of size 610mmx610mm x305mm. Make- Thermadyne /Puromatic/ Primide/ Dyna as approved by GE

4

-

-

... More
S&F in repair FINE filter, flange type, efficiency 99.00% down to 5.0 micron and EU 5 of size 305mm x 610mmx305mm etc. complete all as specified & as directed. Make : Thermadyne/puromatic/ Primide/Dyana as approved by GE

2

-

-

... More
S&F in repair FINE filter flange type, efficiency 99.00% down to 5.0 micron and EU 5 of size 610mmx 305mmx 305mm etc. complete all as specified & as directed. Make- Thermadyne/Puromatic/ Primide/Dyna as approved by GE

2

-

-

... More
S&F in repair FINE filter flange type, efficiency 99.00% down to 5.0 micron and EU 5 of size 305mmX 305mm X305mm. Make- Thermadyne/Puromatic/ Primide/Dyna as approved by GE

1

-

-

... More
S&F in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 610mmx610mmx50mm etc. complete all as specified & as directed. Make- Thermadyne/Puromatic/ Primide/Dyna as approved by GE

38

-

-

... More
S&F in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 610mmx305mmx50mm etc. complete all as specified & as directed. Make- Thermadyne/Puromatic/ Primide/Dyna as approved by GE

6

-

-

... More
S&F in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 305mmx305mmx50mm etc. complete all as specified & as directed. Make- Thermadyne/Puromatic/ Primide/Dyna as approved by GE

1

-

-

... More
S&F in repair HF type HRC cylindrical fuses of rating from 2A to 32A etc. complete all as specified & as directed. Make- L&T/BCH/Havells as approved.

20

-

-

... More
S&F in repair HF type HRC cylindrical fuses of rating from 63A etc. complete all as specified & as directed. Make- L&T/BCH/Havells as approved.

20

-

-

... More
S&F in repair HN type DIN fuse links of rating 200A etc. complete all as specified & as directed. Make : L&T/BCH/Havells as approved.

10

-

-

... More
S&F in repair HN type DIN fuse links of rating 630A etc. complete all as specified & as directed. Make : L&T /BCH/Havells as approved.

5

-

-

... More
Repair and Maint of 200TR capacity cooling tower. Maintenance work include cleaning of cooling tower by removing scale and sludge formation, oiling & greesing of moving parts, replacement of PVC fills, replacement of other defective parts etc. complete all as specified & as directed. (Note:- Parts replaced will be measured and paid separately under respective item of BOQ)

1

-

-

... More
S&F in repairs sprinkler head of size 6th with 4 blades and all accessories etc. complete all as specified & as directed.

1

-

-

... More
S&F in repairs PVC drift eliminator etc. complete all as specified & as directed.

1

-

-

... More
S&F in repairs PVC sprinkler pipe with end cap etc. complete all as specified & as directed.

4

-

-

... More
S&F in repairs tension devices viz. tie rod, turn buckle and clamp etc. complete all as specified & as directed.

1

-

-

... More
S&F in repairs pipe louvre etc. complete all as specified & as directed.

1

-

-

... More
S&F in repairs PVC fills of cooling tower of size 600mm x 300mm x 150mm etc. complete all as specified & as directed.

580

-

-

... More
M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 32x6 mm by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I connected to earthing point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete.

12

-

-

... More
S&F in repair complete electrical internal wiring of 80 TR Central AC Plant compressor contol panel all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&F in repair MCCB 630A, TP,415V, 50 Hz, 50KA adjustable type, thermal release etc. complete all as specified & as directed.

1

-

-

... More
S&F in repair MCCB 400A, TP,415V, 50 Hz, 36KA adjustable type etc. complete all as specified & as directed.

2

-

-

... More
S&F in repair MCCB 250A, TP, 415V, 50 Hz 36KA adjustable type etc. complete all as specified & as directed.

4

-

-

... More
S&F in repair MCCB 160A, TP,415V, 50 Hz 36KA adjustable type etc. complete all as specified & as directed.

2

-

-

... More
Supply, laying, connecting and testing of XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 185 Sqmm, 3.5 core from various panels upto their respective equipment on ground / floor / perforated trays with appropriate clamps /lugs/ fixing arrangements complete as directed by Engr-in-Charge.

100

-

-

... More
Supply, laying, connecting and testing of XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 35 Sqmm, 4 core from various panels upto their respective equipment on ground / floor / perforated trays with appropriate clamps/ lugs /fixing arrangements complete as directed by Engr-in-Charge.

200

-

-

... More
Schedule of Credit

-

-67924

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.