Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date24 Dec 2024
Closing Date14 Jan 2025
Tender Amount₹ 25,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for rewinding of motor of submersible pump motor set of capacity 10 HP/ 12.5 HP, 3 phase, 415 V, 50 Hz of any Make and any type with PVC coated super enamelled copper conductor of the same specification as per the old one including insulation materials and cable jointing and testing at site complete all as specified and as directed. Note: The job should be completed within 72 hours from the receipt of complaint failing which a recovery of ₹1000.00 per day shall be made.

5

-

-

... More
M & L for rewinding of motor of submersible pump motor set of capacity 15 HP, 3 phase, 415 V, 50 Hz of any Make and any type with PVC coated super enamelled copper conductor of the same specification as per the old one including insulation materials and cable jointing and testing at site complete all as specified and as directed. Note: The job should be completed within 72 hours from the receipt of complaint failing which a recovery of ₹1000.00 per day shall be made.

5

-

-

... More
Supply only Motor thrust plate for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

8

-

-

... More
Supply only Motor thrust bearing for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

8

-

-

... More
Supply only Bearing bush for motor housing Upper/Lower G.M for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

20

-

-

... More
Supply only Motor oil seal for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

8

-

-

... More
Supply only Stage Casing Cast Iron for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

20

-

-

... More
Supply only Pump shaft high carbon steel of same make of pump manufacture for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

8

-

-

... More
Supply only Diffuser PTMT with fixing screw for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

50

-

-

... More
Supply only Distance outlet casing for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

15

-

-

... More
Supply only NRV body for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

7

-

-

... More
Supply only Impeller PTMT KB 100 for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

80

-

-

... More
Supply only Flange stud with nut & bolts for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

5

-

-

... More
Supply only Motor stud with nut & bolts for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

5

-

-

... More
Supply only Pump strip for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

5

-

-

... More
Supply only Stainless steel Sleeve for rotor for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

15

-

-

... More
Supply only Bottom housing for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

8

-

-

... More
Supply only Impeller neck ring for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

70

-

-

... More
Supply only Guide/ Distance bush for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

6

-

-

... More
Supply only Coupling for motor pump for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

8

-

-

... More
Supply only Motor sand guard for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

6

-

-

... More
Supply only Impeller key for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

70

-

-

... More
Supply only Aluminium strainer for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

6

-

-

... More
Supply only Disc PVC for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

8

-

-

... More
Supply only Adjusting bolt for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

6

-

-

... More
Supply only Top Bush Sleeve Set for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

15

-

-

... More
Supply only Bottom Bush Sleeve Set for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

8

-

-

... More
Supply only Cable seal for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

8

-

-

... More
Supply only Drain Plug gunmetal for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

8

-

-

... More
Supply only Stator slot complete with all necessary arrangements for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

20

-

-

... More
Supply only Rotor for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

2

-

-

... More
Supply only Stator with winding for submersible pump motor set having capacity of 10/ 12.5 HP and of Make of Jyoti/ BS/ CALAMA/ KSB/ SU/ Kirloskar complete all as specified and as directed.

2

-

-

... More
M & L for rewinding of motor of submersible mono pump motor set of capacity 10 HP/ 12.5 HP, 3 phase, 415 V, 50 Hz of any Make and any type with PVC coated super enamelled copper conductor of the same specification as per the old one including insulation materials and cable jointing and testing at site complete all as specified and as directed. Note: The job should be completed within 72 hours from the receipt of complaint failing which a recovery of ₹1000.00 per day shall be made.

2

-

-

... More
Dismantling of submersible mono pump motor set of any capacity, any Make, any type and overhauling, servicing, cleaning thoroughly discharge/suction cases, impellers, shaft and assembling pump carefully after repairing and replacement of worn out/ unserviceable parts including testing, applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of pump external surface including testing at the site complete all as specified and as directed. Note: - (i) Major spare parts required for repair shall be measured and paid separately. (ii) Minor spare parts like nut/bolts/welding etc. shall be included in the quoted rate of the contractor.

4

-

-

... More
M & L for rewinding of motor of submersible mono pump motor set of capacity 5 HP/ 7.5 HP, 3 phase, 415 V, 50 Hz of any Make and any type with PVC coated super enamelled copper conductor of the same specification as per the old one including insulation materials and cable jointing and testing at site complete all as specified and as directed. Note: The job should be completed within 72 hours from the receipt of complaint failing which a recovery of ₹1000.00 per day shall be made.

2

-

-

... More
S & F in repairs submersible cable flat PVC insulation of type C and having PVC sheath of type ST2, flexible copper conductor, FR-LSH, 3 core of size 10 sqmm complete all as specified and as directed.

700

-

-

... More
S & F in repairs digital voltmeter, 3 phase, 415 volts, 3 line LED display, class 0.5 as per IEC 62053-22, 4 digit display type, measuring voltage range 20 V to 500 V, nominal voltage range 57.5 V to 240 V (phase to neutral); 100 V to 415 V (phase to phase), over voltage 150% Un continuous, short time over current 120 A for 1 sec, IP54 protection degree for front fascia, impulse withstand 6.5 kV, dimension 96 mm X 96 mm complete all as specified and as directed.

4

-

-

... More
S & F in repairs digital ammeter, 3 phase, 415 volts, 3 line LED display, class 0.5 as per IEC 62053-22, 4 digit display type, measuring current range 50 mA to 6 A, nominal current range (In) 1 A or 5 A, overload 150% In continuous, short time over current 120 A for 1 sec, IP54 protection degree for front fascia, impulse withstand 6.5 kV, dimension 96 mm X 96 mm complete all as specified and as directed.

4

-

-

... More
S & F 40 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed.

5

-

-

... More
S & F in repairs mini contactor with screw connection, 3 pole, AC operated, 16 Amp to star delta starter / control panel for submersible pump set/mono block pump as per the existing complete all as specified and as directed.

3

-

-

... More
S & F in repairs Mini contactor with screw connection, 3 pole, AC operated, 20 Amp to star delta starter / control panel for submersible pump set/mono block pump as per the existing complete all as specified and as directed.

3

-

-

... More
S & F in repairs No volt coil 200/240 Volt 50 Hz to star delta starter / control panel for submersible pump set/mono block pump as per the existing complete all as specified and as directed.

3

-

-

... More
S & F in repairs No volt coil 380/415 Volt 50 Hz to star delta starter / control panel for submersible pump set/mono block pump as per the existing complete all as specified and as directed.

3

-

-

... More
S & F in repairs Thermal overload relay, range 10 to 14 Amp to star delta starter / control panel for submersible pump set/mono block pump as per the existing complete all as specified and as directed.

3

-

-

... More
S & F in repairs Thermal overload relay, range 14 to 19 Amp to star delta starter / control panel for submersible pump set/mono block pump as per the existing complete all as specified and as directed.

2

-

-

... More
S & F in repairs On-delay electronic timer, 220-230 V AC of required time range to star delta starter / control panel for submersible pump set/mono block pump as per the existing complete all as specified and as directed.

2

-

-

... More
S & F in repairs On-delay electronic timer, 110-130 V AC of required time range to star delta starter / control panel for submersible pump set/mono block pump as per the existing complete all as specified and as directed.

3

-

-

... More
S & F in repairs Single phase preventor 230 volt to star delta starter / control panel for submersible pump set/mono block pump as per the existing complete all as specified and as directed.

2

-

-

... More
S & F miniature circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.

1

-

-

... More
Supply and laying column pipe 50 mm bore both end flanged made out of GI tubing medium heavy welded at end of column pipe cutting of groove to house submersible cable 3 core length of each column pipe not exceeding 3.10 metres complete all as specified and as directed.

90

-

-

... More
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.

225

-

-

... More
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed.

25

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.

170

-

-

... More
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point

80

-

-

... More
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

800

-

-

... More
Taking up or down 25 mm or 32 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

500

-

-

... More
Taking up or down 40 mm or 50 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

150

-

-

... More
Taking up or down 80 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

100

-

-

... More
Taking up or down 100 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

100

-

-

... More
Supplying & laying in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

500

-

-

... More
Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

300

-

-

... More
Supplying & laying in trenches 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

200

-

-

... More
Supplying & fixing to walls and ceilings or laid in floors 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

200

-

-

... More
Supplying & fixing to walls and ceilings or laid in floors 40 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

100

-

-

... More
Supplying & laying in trenches 50 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

150

-

-

... More
Supplying & laying in trenches 80 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

100

-

-

... More
Supplying & laying in trenches 100 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

100

-

-

... More
Supplying, laying, connecting, jointing and testing in trenches ductile iron fittings (special castings) (class K12 as per IS 9523: 2000) for ductile iron pressure pipe for water mains upto 300 mm nominal dia (spigot and socket and flange ends (for push on joints and flanged joints) with external coatings of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 9523: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 for push on joints and rubber gasket as per IS 638: 1979 for flanged joints complete all as specified and as directed.

150

-

-

... More
Cutting the existing cast iron/ ductile iron/ galvanised iron pipes 80 mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed.

2

-

-

... More
M & L for cutting galvanised mild steel pipe of nominal bore 80 mm, in position for and including insertion of new tee piece including necessary fittings and fixtures complete all as specified and as directed.

5

-

-

... More
S & F in trenches, to walls and ceilings or laid in floors galvanised iron close taper nipple, nominal bore 80 mm, standard length 75 mm, made with heavy tube conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

15

-

-

... More
S & F in repairs in trenches, to walls and ceilings or laid in floors galvanised iron pipe union, nominal size of outlet 80 mm, minimum length 180 mm conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

5

-

-

... More
M & L for cutting galvanised mild steel pipe of nominal bore 100 mm, in position for and including insertion of new tee piece including necessary fittings and fixtures complete all as specified and as directed.

4

-

-

... More
S & F in trenches, to walls and ceilings or laid in floors galvanised iron close taper nipple, nominal bore 100 mm, standard length 87 mm, made with heavy tube conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

4

-

-

... More
S & F in trenches, to walls and ceilings or laid in floors galvanised iron close taper nipple, nominal bore 150 mm, standard length 96 mm, made with heavy tube conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

5

-

-

... More
S & F in repairs saddle piece with suitable drilled hole made out of mild steel flat iron 50 mm X 5 mm of size 50 mm x 20 mm for taking branch connection of 20 mm bore from 50 mm bore main pipeline including necessary excavation & earth work in any type of soil complete all as specified & as directed.

10

-

-

... More
S & F in repairs saddle piece with suitable drilled hole made out of mild steel flat iron 50 mm X 5 mm of size 50 mm X 25 mm for taking branch connection of 25 mm bore from 50 mm bore main pipeline including necessary excavation & earth work in any type of soil complete all as specified & as directed.

8

-

-

... More
S & F in repairs saddle piece with suitable drilled hole made out of mild steel flat iron 50 mm X 5 mm of size 80 mm X 20 mm for taking branch connection of 20 mm bore from 80 mm bore main pipeline including necessary excavation & earth work in any type of soil complete all as specified & as directed.

8

-

-

... More
S & F in repairs saddle piece with suitable drilled hole made out of mild steel flat iron 50 mm X 5 mm of size 80 mm X 25 mm for taking branch connection of 25 mm bore from 80 mm bore main pipeline including necessary excavation & earth work in any type of soil complete all as specified & as directed.

8

-

-

... More
Burning out old, leaked lead joints, dewatering and M & L for run lead joints for 80mm bore CI pipe and fittings spigot and socketed ends including material like lead, spun yarn caulking etc including necessary excavation & earth work in any type of soil complete all as specified. Notes: -(i) The contractor shall be responsible for making good the damages occurred during working. The decision of the Accepting Officer shall be final and binding regarding defects / damages / breakage of existing equipment / lines / structures etc. (ii)The job should be completed within 8 hours from the receipt of complaint failing which a recovery of ₹300.00 per complaint per hour shall be made.

10

-

-

... More
Burning out old, leaked lead joints, dewatering and M & L for run lead joints for 100mm bore CI pipe and fittings spigot and socketed ends including material like lead, spun yarn caulking etc including necessary excavation & earth work in any type of soil complete all as specified. Notes: - (i) The contractor shall be responsible for making good the damages occurred during working. The decision of the Accepting Officer shall be final and binding regarding defects / damages / breakage of existing equipment / lines / structures etc. (ii)The job should be completed within 8 hours from the receipt of complaint failing which a recovery of ₹300.00 per complaint per hour shall be made.

15

-

-

... More
Burning out old, leaked lead joints, dewatering and M & L for run lead joints for 150mm bore CI pipe and fittings spigot and socketed ends including material like lead, spun yarn caulking etc including necessary excavation & earth work in any type of soil complete all as specified. Notes: - (i) The contractor shall be responsible for making good the damages occurred during working. The decision of the Accepting Officer shall be final and binding regarding defects / damages / breakage of existing equipment / lines / structures etc. (ii)The job should be completed within 8 hours from the receipt of complaint failing which a recovery of ₹300.00 per complaint per hour shall be made.

10

-

-

... More
S & F in repairs 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed.

20

-

-

... More
S & F in repairs 25 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed.

10

-

-

... More
S & F in repairs 40 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed.

2

-

-

... More
S & F in repairs 50 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed.

3

-

-

... More
S & F in repairs 80 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed.

2

-

-

... More
M & L for repair of leaking joint in 80 mm bore galvanised pipeline by removing existing broken socket, rethreading of pipes and supply & fixing new galvanised iron pipe union of 80 mm bore in place of broken socket and re-jointing of pipe, testing of joint including necessary excavation & earth work in any type of soil including dewatering complete all as specified & as directed.

30

-

-

... More
M & L for repair of leaking joint in 20 to 50 mm bore galvanised pipeline by removing existing broken socket, rethreading of pipes and supply & fixing new galvanised iron pipe union of 20 to 50 mm bore in place of broken socket and re-jointing of pipe, testing of joint including necessary excavation & earth work in any type of soil including dewatering complete all as specified & as directed.

40

-

-

... More
M & L for repair of leaking joint in 100 to 150 mm bore cast iron/ ductile iron pipeline by removing existing broken socket, rethreading of pipes and supply & fixing new galvanised iron pipe union of 100 to 150 mm bore in place of broken socket and rejointing of pipe, testing of joint including necessary excavation & earth work in any type of soil including dewatering complete all as specified & as directed.

6

-

-

... More
Dismantling existing sluice valve of nominal size 80 mm dia complete all as specified and as directed.

1

-

-

... More
Dismantling existing sluice valve of nominal size 100 mm dia complete all as specified and as directed.

1

-

-

... More
Dismantling existing sluice valve of nominal size 150 mm dia complete all as specified and as directed.

1

-

-

... More
M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 80 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.

1

-

-

... More
M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 100 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.

1

-

-

... More
M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 150 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.

1

-

-

... More
S & F in repairs flanged reflux valve (non-return) of single door, swing check type nominal pressure (PN 1.6) of preferred materials as per IS 5312 (Part 1): 2004, nominal size 80 mm complete all as specified and as directed.

1

-

-

... More
S & F in repairs flanged reflux valve (non-return) of single door, swing check type nominal pressure (PN 1.6) of preferred materials as per IS 5312 (Part 1): 2004, nominal size 100 mm complete all as specified and as directed.

1

-

-

... More
S & F in repairs cast iron / ductile iron detachable joint with rubber ring, ISI marked, Class-15 suitable for 80 mm bore cast iron/ ductile iron pipe with nuts, bolts including necessary excavation & earth work in any type of soil including dewatering complete all as specified and as directed.

10

-

-

... More
S & F in repairs cast iron / ductile iron detachable joint with rubber ring, ISI marked, Class-15 suitable for 100 mm bore cast iron/ ductile iron pipe with nuts, bolts including necessary excavation & earth work in any type of soil including dewatering complete all as specified and as directed.

10

-

-

... More
S & F in repairs cast iron / ductile iron detachable joint with rubber ring, ISI marked, Class-15 suitable for 150 mm bore cast iron/ ductile iron pipe with nuts, bolts including necessary excavation & earth work in any type of soil including dewatering complete all as specified and as directed.

10

-

-

... More
Dismantling of the existing valve chamber & M & L for construction of new valve pit/chamber of size 1350 mm (Length) X 1000 mm (Breadth) X 1200 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. TD/2004/26 Sheet Nos 1/3, 2/3 and 3/3 of HQ CE Jaipur Zone complete all as specified and as directed.

1

-

-

... More
Cleaning of overhead reservoir of RCC of capacity 50000 gallons. All internal and external sides of water tanks shall be properly cleaned, internal walls of water tank bottom, side walls, internal openings, partition walls, bottom of top slab, haunch surfaces etc. shall be cleaned with pressure jet. Cleaning operation shall involve 1. Dewatering of water tanks up to 100-150 mm water table in tanks, agency shall bring own arrangement for dewatering pump, suitable piping till nearest drain etc. as instructed by the Engineer-in-Charge. 2. Cleaning and removal of algae from bottom, side walls, partitions, internal openings etc. with high pressure jet machine of pressure 75-100 bars without damaging tank surface and waterproofing etc. 3. Dewatering of water containing wall wash sludge / algae etc. by dewatering pump with suitable piping till nearest drain etc. as instructed by the Engineer-in-Charge. 4. Internal walls, partitions, cover slab bottom etc. shall be cleaned with mechanical soft scrubber with cleaning detergent suitable for tank cleaning operations. 5. Final cleaning of Tank with water. 6. The remaining sludge should then to be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial vacuum cleaners to make the floor totally dirt free, application/spraying of anti-bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 feet long ultraviolet radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the operations should be executed by trained workers and technicians, properly dressed along with gum boots, safety harness to work as per the direction of the Engineer-in-Charge. Agency shall bring suitable fittings to connect cleanout pipe and suitable length pipe using cleanout facility if available and operational without damaging water tank. Nothing extra shall be paid separately. Agency shall be responsible for complete cleaning, suction, disposal activity and thereafter. Any damages to water tank during cleaning operation shall be repaired by the agency with no cost to the department. Agency shall ensure and implement safe working conditions for his labourers during execution, all necessary safety measures and harness shall be used before taking-up work. Suitable lighting and ventilation should be provided by the Agency before cleaning of covered tanks. Agency shall be solitary responsible for the lapses in the safety during the work and allied compensations. Nothing extra shall be paid separately, etc. complete all as specified and as directed.

1

-

-

... More
Cleaning of overhead reservoir of RCC of capacity 25000/30000 gallons. All internal and external sides of water tanks shall be properly cleaned, internal walls of water tank bottom, side walls, internal openings, partition walls, bottom of top slab, haunch surfaces etc. shall be cleaned with pressure jet. Cleaning operation shall involve 1. Dewatering of water tanks up to 100-150 mm water table in tanks, agency shall bring own arrangement for dewatering pump, suitable piping till nearest drain etc. as instructed by the Engineer-in-Charge. 2. Cleaning and removal of algae from bottom, side walls, partitions, internal openings etc. with high pressure jet machine of pressure 75-100 bars without damaging tank surface and waterproofing etc. 3. Dewatering of water containing wall wash sludge / algae etc. by dewatering pump with suitable piping till nearest drain etc. as instructed by the Engineer-in-Charge. 4. Internal walls, partitions, cover slab bottom etc. shall be cleaned with mechanical soft scrubber with cleaning detergent suitable for tank cleaning operations. 5. Final cleaning of Tank with water. 6. The remaining sludge should then to be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial vacuum cleaners to make the floor totally dirt free, application/spraying of anti-bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 feet long ultraviolet radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the operations should be executed by trained workers and technicians, properly dressed along with gum boots, safety harness to work as per the direction of the Engineer-in-Charge. Agency shall bring suitable fittings to connect cleanout pipe and suitable length pipe using cleanout facility if available and operational without damaging water tank. Nothing extra shall be paid separately. Agency shall be responsible for complete cleaning, suction, disposal activity and thereafter. Any damages to water tank during cleaning operation shall be repaired by the agency with no cost to the department. Agency shall ensure and implement safe working conditions for his labourers during execution, all necessary safety measures and harness shall be used before taking-up work. Suitable lighting and ventilation should be provided by the Agency before cleaning of covered tanks. Agency shall be solitary responsible for the lapses in the safety during the work and allied compensations. Nothing extra shall be paid separately, etc. complete all as specified and as directed.

2

-

-

... More
Cleaning of overhead reservoir of RCC of capacity 150000 gallons. All internal and external sides of water tanks shall be properly cleaned, internal walls of water tank bottom, side walls, internal openings, partition walls, bottom of top slab, haunch surfaces etc. shall be cleaned with pressure jet. Cleaning operation shall involve 1. Dewatering of water tanks up to 100-150 mm water table in tanks, agency shall bring own arrangement for dewatering pump, suitable piping till nearest drain etc. as instructed by the Engineer-in-Charge. 2. Cleaning and removal of algae from bottom, side walls, partitions, internal openings etc. with high pressure jet machine of pressure 75-100 bars without damaging tank surface and waterproofing etc. 3. Dewatering of water containing wall wash sludge / algae etc. by dewatering pump with suitable piping till nearest drain etc. as instructed by the Engineer-in-Charge. 4. Internal walls, partitions, cover slab bottom etc. shall be cleaned with mechanical soft scrubber with cleaning detergent suitable for tank cleaning operations. 5. Final cleaning of Tank with water. 6. The remaining sludge should then to be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial vacuum cleaners to make the floor totally dirt free, application/spraying of anti-bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 feet long ultraviolet radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the operations should be executed by trained workers and technicians, properly dressed along with gum boots, safety harness to work as per the direction of the Engineer-in-Charge. Agency shall bring suitable fittings to connect cleanout pipe and suitable length pipe using cleanout facility if available and operational without damaging water tank. Nothing extra shall be paid separately. Agency shall be responsible for complete cleaning, suction, disposal activity and thereafter. Any damages to water tank during cleaning operation shall be repaired by the agency with no cost to the department. Agency shall ensure and implement safe working conditions for his labourers during execution, all necessary safety measures and harness shall be used before taking-up work. Suitable lighting and ventilation should be provided by the Agency before cleaning of covered tanks. Agency shall be solitary responsible for the lapses in the safety during the work and allied compensations. Nothing extra shall be paid separately, etc. complete all as specified and as directed.

2

-

-

... More
Cleaning of underground sump of RCC of capacity 50000 gallons. All internal and external sides of water tanks shall be properly cleaned, internal walls of water tank bottom, side walls, internal openings, partition walls, bottom of top slab, haunch surfaces etc. shall be cleaned with pressure jet. Cleaning operation shall involve 1. Dewatering of water tanks up to 100-150 mm water table in tanks, agency shall bring own arrangement for dewatering pump, suitable piping till nearest drain etc. as instructed by the Engineer-in-Charge. 2. Cleaning and removal of algae from bottom, side walls, partitions, internal openings etc. with high pressure jet machine of pressure 75-100 bars without damaging tank surface and waterproofing etc. 3. Dewatering of water containing wall wash sludge / algae etc. by dewatering pump with suitable piping till nearest drain etc. as instructed by the Engineer-in-Charge. 4. Internal walls, partitions, cover slab bottom etc. shall be cleaned with mechanical soft scrubber with cleaning detergent suitable for tank cleaning operations. 5. Final cleaning of Tank with water. 6. The remaining sludge should then to be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial vacuum cleaners to make the floor totally dirt free, application/spraying of anti-bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 feet long ultraviolet radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the operations should be executed by trained workers and technicians, properly dressed along with gum boots, safety harness to work as per the direction of the Engineer-in-Charge. Agency shall bring suitable fittings to connect cleanout pipe and suitable length pipe using cleanout facility if available and operational without damaging water tank. Nothing extra shall be paid separately. Agency shall be responsible for complete cleaning, suction, disposal activity and thereafter. Any damages to water tank during cleaning operation shall be repaired by the agency with no cost to the department. Agency shall ensure and implement safe working conditions for his labourers during execution, all necessary safety measures and harness shall be used before taking-up work. Suitable lighting and ventilation should be provided by the Agency before cleaning of covered tanks. Agency shall be solitary responsible for the lapses in the safety during the work and allied compensations. Nothing extra shall be paid separately, etc. complete all as specified and as directed.

1

-

-

... More
Disconnecting, taking out old unserviceable under ground cable of rated voltage 1100 V, nominal cross sectional area of main conductor 50 sqmm, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed.

250

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.

250

-

-

... More
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.

13

-

-

... More
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed.

1.4

-

-

... More
Supplying & laying in trenches, in road cutting and along pole 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

10

-

-

... More
S & F in repairs nominal 2.0 mm thick insulating mats of size 2 m X 1 m, made of elastomer conforming to IS-15652: 2006 and meeting the requirement of IS- 5216 (Part -1 & 2) IS 8437, IEC-479 Pub -1 along with suitable adhesive/ homebound, PV resin water proofing compound and sealing material as per recommendation of Annex 'A’, Clause- 'C’ of IS- 15652 and suitable for class - A upto 3.3 kV complete all as specified and as directed.

2

-

-

... More
Supply & fix in repairs three phase fully automatic star delta controller for submersible pump motor set of capacity 10 HP to 20 HP, AC – 3 Duty, 50 Hz, 415 Volt, 3 Phase, 13 - 21 Amp relay range & testing as per Model MU-G20, 15/20HP, FASD (SS95984COCO) of L&T equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.

1

-

-

... More
S & F MCCB rated current(In): 63A, ultimate short circuit breaking capacity (Icu): 25 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, fixed thermal and fixed magnetic setting, four pole, suitable for 415 V, 50 Hz AC supply complete all as specified and as directed.

1

-

-

... More
M & L for repair, painting of LT panel board or distribution feeder pillar box of any size and dimension (in situ), including replacing internal wiring, minor repairing of panels like door hinges with welding, nuts and bolts, painting on both external and internal surfaces installed and located at different sites in scattered area under the GE including the following: - (a) preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc. complete. (b) Spray painting with two coats of synthetic enamel paint of approved make / quality all as directed at site.

3

-

-

... More
Supply only calcium hypochlorite in granular form, active chlorine content of minimum 65%, type I, not more than 10% passed a 100 μm sieve, 5.5% maximum moisture content, factory sealed in 45 kg polyethylene drums with a lid and closure device to form an airtight seal to the drum. Suitably packed and marked with hazardous goods reference conforming to BS EN 900: 2014.

3

-

-

... More
S & F in repairs mild steel nut,bolt, washer etc. of various sizes as per the site requirement complete all as specified and as directed.

10

-

-

... More
S & F in repairs hemp gland packings (grade II) or jute gland packings (grade III) as per IS IS 5414 : 2024 complete all as specified and as directed.

3

-

-

... More
Taking down sluice valve of nominal size of 80 mm and M & L for replacing of nuts, bolts, gasket, gland packing, gunmetal scour (gutka), stuffing box etc. including greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

5

-

-

... More
Taking down sluice valve of nominal size of 100 mm and M & L for replacing of nuts, bolts, gasket, gland packing, gunmetal scour (gutka), stuffing box etc. including greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

5

-

-

... More
Taking down sluice valve of nominal size of 150 mm and M & L for replacing of nuts, bolts, gasket, gland packing, gunmetal scour (gutka), stuffing box etc. including greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

3

-

-

... More
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.

2

-

-

... More
M & L for cleaning, upkeeping and maintaining of MES installations / campus/ outside the periphery of transformer platform/ two poles structure/ four pole structures by surface dressing or trimming of natural ground to remove small inequalities not exceeding 15 cm deep (including removing vegetation / shrubs / brush wood / under-growth) including carrying away the rubbish to a distance of not exceeding 50 m away complete all as specified and as directed. Note: - The contractor shall clean, upkeep and maintain the premises during the contract period and the payment shall be made only once for entire contract period. The measurement shall be in sqm.

5000

-

-

... More
Supply only 'O' Tolidine solution complete all as specified and as directed.

2

-

-

... More
Taking down old rusted paint in pit cover and M & L for two coat of black enamel paint in pit cover including necessary repair works complete all as specified and as directed.

12

-

-

... More
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.

2

-

-

... More
Supply only galvanised iron socket union, nominal size of outlet 15 mm, minimum length 57 mm conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

10

-

-

... More
Supply only galvanised iron socket union, nominal size of outlet 20 mm, minimum length 57 mm conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

12

-

-

... More
Supply only galvanised iron socket union, nominal size of outlet 25 mm, minimum length 57 mm conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

10

-

-

... More
Supply only galvanised iron socket union, nominal size of outlet 50 mm, minimum length 57 mm conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

12

-

-

... More
Supply only galvanised iron socket, nominal bore 15 mm, minimum outside diameter 27 mm, minimum length 37, maximum inside diameter of internal parallel thread 18.773 mm conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

10

-

-

... More
Supply only galvanised iron socket, nominal bore 20 mm, minimum outside diameter 32.5 mm, minimum length 39, maximum inside diameter of internal parallel thread 24.259 mm conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

15

-

-

... More
Supply only galvanised iron socket, nominal bore 25 mm, minimum outside diameter 39.5 mm, minimum length 46, maximum inside diameter of internal parallel thread 30.471 mm conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

10

-

-

... More
S & F in trenches, to walls and ceilings or laid in floors galvanised iron barrel nipple, nominal bore 15 mm, standard length 51 mm, made with heavy tube conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

10

-

-

... More
S & F in trenches, to walls and ceilings or laid in floors galvanised iron barrel nipple, nominal bore 20 mm, standard length 54 mm, made with heavy tube conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

10

-

-

... More
S & F in trenches, to walls and ceilings or laid in floors galvanised iron barrel nipple, nominal bore 25 mm, standard length 60 mm, made with heavy tube conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

10

-

-

... More
S & F in trenches, to walls and ceilings or laid in floors galvanised iron close taper nipple, nominal bore 15 mm, standard length 37 mm, made with heavy tube conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

12

-

-

... More
S & F in trenches, to walls and ceilings or laid in floors galvanised iron close taper nipple, nominal bore 20 mm, standard length 39 mm, made with heavy tube conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

12

-

-

... More
S & F in trenches, to walls and ceilings or laid in floors galvanised iron close taper nipple, nominal bore 25 mm, standard length 46 mm, made with heavy tube conforming to IS 1239 (Part 2): 2011 complete all as specified and as directed.

14

-

-

... More
Supply only saddle piece with suitable drilled hole made out of mild steel flat iron 50 mm X 5 mm of size 50 mm x 20 mm for taking branch connection of 20 mm bore from 50 mm bore main pipeline including necessary excavation & earth work in any type of soil complete all as specified & as directed.

10

-

-

... More
Supply only saddle piece with suitable drilled hole made out of mild steel flat iron 50 mm X 5 mm of size 50 mm X 25 mm for taking branch connection of 25 mm bore from 50 mm bore main pipeline including necessary excavation & earth work in any type of soil complete all as specified & as directed.

8

-

-

... More
Supply only lead wool complete all as specified and as directed.

10

-

-

... More
Supply and fixing in repairs aluminium strip 25 mm X 3 mm for horizontal conductors and down conductors including suitable design of fixing components of galvanised steel as per fig 28 of IS 2309: 1989 complete all as specified and as directed.

100

-

-

... More
Supply and fix in repairs Air termination (vertical conductor), single pointed aluminium rod 12 mm dia and 300 mm long including suitable design of fixing components of gun metal as per fig 30 of IS 2309: 1989 complete all as specified and as directed.

2

-

-

... More
Supply and fixing in repairs test joint terminal block made of gun metal or phosphorus bronze size 75 mm X 75 mm X 25 mm, drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screw complete all as specified and as directed.

2

-

-

... More
S & F in repairs only 32 mm X 6 mm galvanised mild steel strip for horizontal conductors and down conductors including suitable design of fixing components of galvanised steel as per fig 28 of IS 2309: 1989 complete all as specified and as directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.