Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 84,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_632849_1Bid Award Id
ViewTender No
82324/94/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole or in any situation all as specified and directed.
3
-
-
... More
Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole or in any situation all as specified and directed.
0.15
-
-
... More
Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out for laying of cables.
385
-
-
... More
All as per ser No-6 above but depth exc 1.5 mtr but not exc 3.00 mtr
0.2
-
-
... More
M&L for tibba sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed.
74.47
-
-
... More
Supply and laying reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx180mmx40mm laid perpendicular to cable length in trench air gap should not more than 5mm to each other after sand cushioning to cable and all as specified and directed.
5200
-
-
... More
Returning and filling in including spreading, leveling , watering and well ramming in layers not exceeding 25 cm thick of excavated earth complete all as specified and directed.
265
-
-
... More
Removal of surplus soil to a distance not exceeding 50 mtr and depositing at a leval not exceeding 1.5 mtrs above the starting point complete all as specified and directed.
120
-
-
... More
Taking out faulty underground 11000 Volt HT cable of different sizes by excavation and removing Jodhpur Stone of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new PCC cable covers as required. Note: (a) 11000 Volt HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Excavation, PCC Cover and earth work will be measured and paid for seperately under respective items of schedule.
200
-
-
... More
S&F cable route indicator made of RCC (Nominal Mix) type B-0 1:2:4 (12.5mm graded stone aggregate) with 8mm TMT Bar c/c of size 1m height X 60cm wide X 10cm thick tapered on top, visible above ground, duly painted with synthetic enemel paint of yellow colour base and letters with black paint. The description for writing for HT cable 11 KV as directed by Engr-in-charge complete all as specified and directed.
Note : Rate for PCC 1:3:6 for foundation (min size 0.8mx0.3mx0.3m) of aggregate size 20mm for cable route indicator deemed to be included in the item.
25
-
-
... More
Dismantling of existing defective HT 33 KV Gang operated air break switch and Supply and installation, commissioning and testing of HT 33 KV outdoor type triple pole gang operated air-break switch double stack type suitable for horizontal mounting rotating type with 9 insulator 200 amps current rating complete mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore medium grade GI pipe of suitable length with locking arrangement, flat iron clamp 50x6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers complete all as directed
1
-
-
... More
Supply and fix outdoor type heat shrinkable end termination cable joint kit including all material and accessories suitable for 3 core 95 sqmm cable of 11000 Volt grade all as per manufactuer recommendation complete all as specified and directed.
3
-
-
... More
All as per Ser No 15 above but suitable for 3 core 120 sqmm cable
6
-
-
... More
All as per Ser No 15 above but suitable for 3 core 150 sqmm cable
6
-
-
... More
All as per Ser No 15 above but suitable for 3 core 185 sqmm cable
4
-
-
... More
Supply and fix indoor type heat shrinkable end termination cable joint kit including all material and accessories suitable for 3 core 95 sqmm cable of 11000 Volt grade all as per manufactuer recommendation complete all as specified and directed.
2
-
-
... More
All as per Ser No 19 above but suitable for 3 core 120 sqmm cable
4
-
-
... More
All as per Ser No 19 above but suitable for 3 core 150 sqmm cable
4
-
-
... More
All as per Ser No 19 above but suitable for 3 core 185 sqmm cable
2
-
-
... More
Supply and fix straight through heat shrinkable cable joint kit including all material and accessories suitable for 3 core 95 sqmm cable of 11000 Volt grade all as per manufactuer recommendation complete all as specified and directed
4
-
-
... More
All as per Ser No 23 above but suitable for 3 core 120 sqmm cable
6
-
-
... More
All as per Ser No 23 above but suitable for 3 core 150 sqmm cable
6
-
-
... More
All as per Ser No 23 above but suitable for 3 core 185 sqmm cable
4
-
-
... More
All T&P expenditure for for tracing out the HT UG cable fault by pin point with cable fault locating machine mounted vahicle including all T&P expenditure to rectify the fault within 08 hrs to restore the supply of HT 11 KV feeder at Banar Mil station and all as specified. Note : The fault will be measured one unit by charging of one HT cable , multiple faults at same cable will be measured single fault and HT Cable joints will be measured and paid seperately and earth work will be paid under relevent item of Schedule and delay beyond 08 hrs will be recovered Rs-1000/- per hour from work done amount.
6
-
-
... More
M&L and fixing in true Vertical position prestressed concrete pole 11.00 Mtr long of size 152mm x 152mm at top and 152 mm x 260mm at bottom of class-9 confirming to relevent IS-1678-1998 code and dismantling and removing the old unsv PCC pole and all as specified and directed at site NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid seprately.
4
-
-
... More
S&F in replacement of GI stay assembly set comprising of 14mm dia 400mm iron stay bow and16mm dia, 2150 mm long stay rod stay plate 230x230x6mm thick, GI stay wire 7/3.15 mm SWG of required length complete with all accessories as shown in electric plate No 1 of SSR Part 1 2009 complete with excavation earth work including PCC 1:3:6 of required quantity with loop insulator, clamps nut bolts etc complete all as specified and directed.
4
-
-
... More
Supply and fixing cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holesfor bolt. In any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint and all as specified and directed.
4
-
-
... More
Dismantling of existing defective HT 11 KV Gang operated air break switch and supply installation, commissioning and testing 11 KV outdoor type, gang operated Air break switch 200 Amp rated triple pole mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level with 25mm GI pipe (Med grade) operating rod of suitable length with expulsion fuses of rating upto 200 Amp comprising of 12 insulators all as specified and directed.
6
-
-
... More
Supplying and fixing in replacement male contact/moving contact for Horizontal/Vertical gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
18
-
-
... More
Supplying and fixing in replacement female contact /fix contact jaw for Horizontal/Vertical gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
18
-
-
... More
Supplying and fixing in replacement tinned copper flexible jumper 200 Amp/400 Amp for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
18
-
-
... More
Supplying and fixing in replacement MS jumper carrier for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
18
-
-
... More
Supplying and fixing in replacement back connector plate for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
18
-
-
... More
Supplying and fixing in replacement porcelain post insulator for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
18
-
-
... More
Supplying and fixing in replacement of Copper fuse wire 5 to 90 Amp complete all as directed at site by Engr-in-charge.
10
-
-
... More
S&F in replacement 25 mm bore medium grade GI pipe including all fitting for HT 11 KV Gang operated air break switch all as specified and directed.
24
-
-
... More
M&L in replacement of earthing with Galvanised Steel earthplate of size 60x60cmx6mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing). Note (i)The earth pit shall be refilled by boulders free from vegetable soil.
(ii) Testing of earthing shall be carried out after completion of earthing.Payment for earthing shall be admissible after satisfactory test result.
6
-
-
... More
M&L in replacement of GI strip of size 32x6 mm including mounting on PVC/Porcelain insulators on wall and burried in ground depth not less than 60 cm in ground complete all as specified and directed by Engineer-in-Charge.
100
-
-
... More
M&L for resagging of overhead conductor section of 11 KV including binding/re-binding of conductor with suitable size of wire and providing of jumpers at the ends as per site requirements complete all as specified and directed by Engr-in-Charge.
Note :- (i) Length of span shall be 40 to 50m.
(ii) Due care shall be given while resagging of overhead conductor that there shall be no damage to pin/post/disc insulator and pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible.(iii) Proper shut down will be taken from department and T&P will be provoded by conractor.
30
-
-
... More
Dismantling and taking down HT pole of old ACSR conductor complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
M&L for Replacement of old ACSR conductor with new ACSR conductor including binding of wire and providing jumpers at the end as per site requirement complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
Fixing and restretching of old serviceable (ACSR) conductor obtained from items No 43 here in before including binding complete all as specified and directed.
1
-
-
... More
M&L for checking , tightening & Replacement of jumpers , clamps connectors of 33 KV bus bar for the Power transformer in the yard / sub station complete all as specified and directed by Engr-in-Charge.
8
-
-
... More
Disconnecting electric outdoor/indoor transformer 11 KV capacity upto 630 KVA from HT/LT terminals and lowering down/getting out from 2/4 pole structure/plinth or from inside sub station for major/Minor repair and transportation to workshop and return back for installation it on original position/location after repairing from workshop complete all as specified and directed . Note : (Rate is deemed to be inclusive of transportation, T&P and man power)complete all as specified and directed .
2
-
-
... More
All as per item No 47.0 here-in -before but capacity of Station transformer 33/.433 KV, 63 KVA
1
-
-
... More
M&l for draining out complete transformer oil from transformer of upto 2000 KVA capacity at site which found major repair and storing the oil in suitable container (container to be provided by the contractor to keep aside for re-use (after repair) and lifting of core assembly by opening of top cover and other items for inspection/examination of core assembly, to make it ready for transportation to carry out rewinding work in workshop (Transportation charges shall be borne by the contractor against item No 47 & 48 of schedule ‘A’)
3
-
-
... More
(a) Repairs to the transformer of capacity upto 630 KVA as follows :-
(i) Rewinding of HT/LT leg coil complete using copper wire /strip of appropriate gauge, size and turn as per existing with double paper coated insulation including all requisite insulating materials like packing sleeves, separator, tapes etc. heating, varnishing the core and winding assembly after framing up top and bottom steel structure of transformer all as specified and directed. (ii) Replacement of all insulating materials other than incorporated for rewinding of HT/LT coils as per existing.
(iii) Replacement of HT procelain bushing with studs, nuts, washers 3 Nos. and LT procelain bushing with studs, nuts, and washers 4 Nos. and connection with primary and secondary windings and reconnecting with the main terminals as required and directed. (iv) Fixing only breather assembly, conservator, oil temperature gauge after proper cleaning, minor repairs etc. as required and directed.
(v) Replacement of all unserviceable gasket from top cover ,4.0mm/6.0mm thick duly pasted with suitable adhesive .
(vi) Replacement of unserviceable bolts with new one and fixing of existing serviceable bolts, nuts, washers of different sizes and tightening properly.
(vii) Repositioning of core and winding assembly inside the tank, assembling complete unit and making the transformer ready for filling oil and subsequent testing as directed. (viii) Painting of Transformer with existing colour with sparying machine. Note :-HT/LT leg coils and transformer oil required for top up shall be measured and paid separately under respective items of schedule.
2
-
-
... More
All as per item No 50 here-in -before but capacity of Station transformer 33/.433 KV, 63 KVA
1
-
-
... More
Supply only HT/LT coils with super enamelled copper wire/strip /DPC of high quality duly matching with the existing guage and impedance complete all as specified and directed ..
800
-
-
... More
Material and Labour for ON load centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine electric operated without any shutdown of transformer including testing oil sample before and after dehydration and filteration oil complete all as specified and directed . Note : (i) Transformer oil required for top up shall be measured and paid for separate
(ii) Contractor have to arrange the dehydration machine and testing kit from his own resources without any extra cost. (iii) dielectric strength of transformer oil not less than 45 KV at 2.5 mm gap
20000
-
-
... More
Supply and filling the transformer oil in factorey sealed barrel with IS-336 of di-electric strength not less than 45 KV at 2.5 mm gap and toping up the oil where ever required in Army area Banar and all as specified and directed.
1600
-
-
... More
Disconnecting electrically & mechanically indoor/outdoor transforemrs upto 630 KVA capacity, lowering down/getting out from plinth, 2/4 pole Structure,indoor sub station carefully for prevent/stoping for leakage of transformer oil by welding / tightening the loose points at site, including opening of top cover, draining out transformer oil and other items and storing the oil in suitable container (container to be provided by the contractor to keep aside for re -use) including replacement of all unserviceable gasket, replacing the unsv HT/LT porcelain Bushing/studs as directed after repairing/stoping of oil leakage the same re-connecting electrically and mechanically, testing complete all as specified and directed. Note.(i) The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transformer oil, T&P, crane, opening/closing of top cover by unscrewing nut, bolts washers , welding etc. (ii) The HT/LT porcelain Bushing , studs or gasket & transformer oil shall be measured and paid separately under respective items of schedule.
10
-
-
... More
Supply and fixing in replacement of transformer bushing on LT 433 volt side including brass spindle/rods duly threded at the end complete with gasket nut bolts and washer suitable for indoor/outdoor transformer capacity 63 KVA to 160 KVA complete all as specified and directed .
16
-
-
... More
All as per item No 56 above but of capacity 200 KVA to 400 KVA
16
-
-
... More
All as per item No 56 above but of capacity 500 KVA to 630 KVA
8
-
-
... More
Supply and fixing in replacement of porcelain transformer bushing HT 11 KV including brass spindle/rods duly threded at the end complete with gasket nut bolts and washer suitable for indoor/outdoor transformer capacity 63 KVA to 160 KVA complete all as directed by Engineer-in-Charge.
12
-
-
... More
All as per item No 59 above but of capacity 200 KVA to 400 KVA
12
-
-
... More
All as per item No 59 above but of capacity 500 KVA to 630 KVA
6
-
-
... More
Supply and Fixing in replacement of transformer silica gel breather complete with all accessories for transformer of capacity 63 KVA to 160 KVA complete all as specified and directed.
4
-
-
... More
All as per item No 62 above but of capacity 200 KVA to 400 KVA
4
-
-
... More
All as per item No 62 above but of capacity 500 KVA to 630 KVA
2
-
-
... More
All as per item No 62 above but of capacity 33/11 KV, 3.15 MVA
1
-
-
... More
S&F in replacement of gasket for packing set of any size suitable for transformer of capacity up to 630 KVA made out of 6 mm thick cock sheet single piece including removing old unserviceable packing kit/ set cleaning the surface of the top cover etc complete all as specified and directed.Note :- The cost of opening of transformer cover/ top if required deemed to be included in the item rate of respective item .
10
-
-
... More
Supply and fixing 3 mm thick Sheet Transparent glass (each not exceeding 0.9 Sqm) ordinary quality and glazing with oil putty on cabin of OTI and WTI gauge of transformer upto capacity 1000 KVA complete all as specified and directed.
4
-
-
... More
Material & labour for replacement of oil level indicator of Transformer of any Cap all as directed by Engineer-in-charge
4
-
-
... More
S&F in replacement Thermometer of transformer capacity upto 1500 KVA complete all as specified and directed
10
-
-
... More
Supply and fill in replacement silica gel in transformer complete all as directed.
5
-
-
... More
M&L for cleaning, scraping out old rubbed paint / rust & Painting of transformer complete with two coat of spray painting with synthetic enamelled gray paint (first grade) by spray painting machine on transformer & Making SM NO on surface of transformer of capacity 63 KVA to 160 KVA outdoor / Indoor type fixed on poles or in Sub Station at different location all as specified and directed.
4
-
-
... More
Description all as per Serial item No 71 here-in-before but 200 KVA to 400 KVA capacity
4
-
-
... More
Description all as per Serial item No 71 here-in-before but 500 to 630 KVA capacity
2
-
-
... More
Disconnecting electric indoor/outdoor transformer 11 KV capacity up to 630 KVA from HT/LT terminals and lifting by hydra for installation on newly constructed plinth/2/4 pole structure complete all as specified and directed .
6
-
-
... More
S&F in replacement the off load Tape changer suitable to 63 to 160 KVA indoor/outdoor transformer with fixing suitable make and fixing and making connection all as required and directed at site .
1
-
-
... More
Material and labor for servicing the ON LOAD tap changer transformer capacity of 200 to 630 indoor/outdoor type by replacing the minor parts such as gear wheels, control wiring and checking the all connections and tap changing terminals decarbonising and servicing the all moving parts of onlaod tap changer and all as specified and directed at site by Engr-in-Charge.
1
-
-
... More
Taking down and servicing for HT switch gear VCB of capacity 400-630 Amp capacity ,11KV by tripping off the breaker and draw out the trolley and servicing and overhauling the mechanical parts with applying the grease and checking the control wiring and tripping mechanism, replacement of damaged minor parts such as control wiring, ferrules, HRC fuse, caliberation of IDMT/Microprocessor numerical/digital relay existing on panels with secondery injection kit and setting the relay of earth fault, short circuit, time delay settings as per existing load of feeder and all as specified and direted by engr-in-charge at 33 KV MRS and depot area
12
-
-
... More
Taking down and servicing for HT switch gear VCB of capacity 400-630 Amp capacity,33KV indoor type including control remote panel by tripping off the breaker servicing and overhauling the mechanical parts with applying the grease and checking the control wiring and tripping mechanism, replacement of damaged minor parts such as control wiring, ferrules, HRC fuse, caliberation of processor numerical/digital relay existing on panels with secondery injection kit and setting the relay of earth fault, short circuit, time delay settings as per existing load of feeder and all as specified and direted by engr-in-charge at 33 KV MRS.
2
-
-
... More
Material and labour for replace the unserviceable spring charging motor in existing VCB's of existing specifications and all as specified and directed at site by Engr-in-Charge.
1
-
-
... More
Supply and fixing in replacement of tripping coil suitable for VCB 400 to 630 Amps to trip the VCB with the operating voltage of 24 vols DC supply and all as specified and directed.
3
-
-
... More
Supply and fixing in replacement of spring of VCB charging/tensioning with top and bottom connecting assembly suitable to fix on existing VCb of any make and model alongwith connected accessories and all as specified and directed.
2
-
-
... More
Material and labour for in replacement of taking down and replace the vacumeinterruptor of existing VCB's of any make and connecting arrangement and all as required and directed at site by Engr-in-Charge.
1
-
-
... More
Supply and fixing, testing , commissioning in replacement of microprocessor relay of 24 volts DC supply operated with earth fault ,over current and with TDS to protect the HT VCB/OCB of 400 to 630 Amps alongwith control wiring of CT primary/secondary winding and all as specified and directed.
1
-
-
... More
Supply and fixing in replacement of 11000 volts grade HRC fuse barrel type of rating upto 60 Amps suitable for existing VCB’s and all as specified and directed by Engr-in-Charge. Note : Item No 79 to 84 Suitable for existing 12 KV indoor type VCB Make-ABB, Siemens & Schneide
6
-
-
... More
Disconnecting HT Supply, 11 KV opening the RMU (indoor/outdoor) after positioning the earth of indl feeder, material and labour for servicing /testing of RMU/control panel including CT, PT and relays in control panel of RMU of capacity 630- 800 Amp, 3-7 way, Make- ABB, Siemens & Schneider etc and rating 11 KV complete as details mentioned as under:-
10
-
-
... More
(a) Details of servicing of RMU :-
(i) Adjustment of mechanism if required.
(ii) Clean the circuit breaker to remove dust and dirt and insulating materials shall be wiped with a clean cloth.
(iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts.
(iv) Check for rust and wear.
(v) Check Spring Tension and pitting of the Cluster Contacts.
(vi) Visual check for rust and deformation.
(vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc.
(viii) Check for loosened connections, rust, damaged lead wires.
(ix) Check whether the contacts are damaged by arcing.
-
-
-
... More
(x) Checking of control circuit & tighten the connections if any.
(xi) Check close & trip coil.
(xii) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish.
(b) The following test shall be carried out:-
(i) Primary Injection Test of CT / PT
(ii) Closing & Opening Timing Test for all three poles.
(iii) IR Test with megger in open and closed condition.
(c) Testing of relays of control panel with Secondary Injection Kit ,checking and programming of relay.
-
-
-
... More
Supply and fixing in replacement of Standered motorised Kit for V module suitable for RMU, 11 KV, 630- 800 Amp, 2-4 way, complete all as directed by Engr In Charge
1
-
-
... More
Material and labour for filling of SF6 gas and testing suitable for RMU, 11 KV, 630- 800 Amp, 2-4 way, complete all as directed by Engr In Charge
6
-
-
... More
Supply and fixing in replacement of Spring charging Motor with Gear 24 V DC suitable for RMU, 11 KV, 630- 800 Amp, 3-7 way, complete all as directed by Engr In Charge
1
-
-
... More
Supply and fixing in replacement of Operating mechanism suitable for RMU, 11 KV, 630- 800 Amp, 2-4 way, Note : Item No 86 to 89 suitable for existing outdoor type RMU Make-ABB, Siemens & Schneide
1
-
-
... More
Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, resin cast epoxy type, of 18.1 KA/Sec having ratio 100/50/5-15 Amps having Core1: Class 5P10, 10VA for protection , Core2: Class 0.5, 10VA for metering including associated wiring complete all as specified and directed
1
-
-
... More
M&L in replacement of Supply, design, Installation, testing and commissioning of totally enclosed busbar chamber of outdoor type IP-55 protection fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type including locking arrangement, aluminum bus bar 400 Amp rating with air tight insulated mounted on insulators, incoming and outgoing cable chamer incl cable gland suitable for size upto 185 Sqmm HT cable complete suitable for operation of 11000 volts grade , 50 hz, AC supply having mounted on angle iron stand fixed at 75 cm from the ground level made out of angle size 65 X 65 X 6 mm grouted in PCC 1:3:6 and all as specified and directed. (Note: (i) The size of bus bar chamber should not be less than 800x800x800mm (ii) Cost of PCC platform 50 mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of Bus Bar chamber shall be submitted by manufacturer will be approved by Accepting Officer before placing order.
4
-
-
... More
M&L for replacement of defective/damaged type Pin type, pocelain, vitreous, white brow or green insulator including one galvanised mild steel spindle, two galvaanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade with fixing on existing 2 pole/4pole/single pole including taking down of old unsv insulator and all as specified and directed.
6
-
-
... More
Taking out old unserviceable 33 KV pin insulator incl taking out 33 KV OH ACSR conductor and supply and fix 33 KV pin type, porcelain, vitreous, insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for fixing of insulator on HT pole incl refixing the OH ACSR conductor at the same place incl binding the conductor to insulator with new binding wire complete all as directed.
5
-
-
... More
M&L for replacement of defective/damaged Disc insulators suitable for 33 KV overhead conductors including removing/providing jumpers with line conductors as per required at site complete all as specified and directed by EIC.
3
-
-
... More
Supply and fix danger notice plate 1.6 mm thick mild steel sheet vitrous enamelled white with latters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size for 11 KV system size 25 x 20 cm all as specified and confirming to to IS : 2551-1982.
10
-
-
... More
Supplying & Fixing in replacement Caution plate “CAUTION MEN AT WORK" of size 40cmx15cm made out of white acrylic sheet with Red coloured glow tape.
4
-
-
... More
Supply fixing and connecting and testing single pole zinc oxide (gapless surge type) heavy duty station class, self supporting outdoor type lighting arrester having rated voltage 09 KV (rms) discharge current 65 KA insulation level 28/75 KV/KVP (Peak) suitable for rated system voltage of 11 KV supply system with maximum continuous operating voltage (MCOV) not less than 7.65 KV (rms) with highly non linear ceramic resister made of zinc oxide in hermetically sealed container complete with metal base, base inculator and suitable terminals for ground connections and pressure relieving arragement complete all as specified Note : The rate quoted against above item shall include necessary fixing arrangement of lightening arresster on two pole/four pole structure as per recommendations of manufactures.
2
-
-
... More
Supply fixing and connecting and testing single pole zinc oxide (gapless surge type) heavy duty station class, self supporting outdoor type lighting arrester having rated voltage 30 KV (rms) discharge current 65 KA insulation level 35/75 KV/KVP (Peak) suitable for rated system voltage of 33 KV supply system with maximum continuous operating voltage (MCOV) not less than 17.05 KV (rms) with highly non linear ceramic resister made of zinc oxide in hermetically sealed container complete with metal base, base inculator and suitable terminals for ground connections and pressure relieving arragement complete all as specified Note : The rate quoted against above item shall include necessary fixing arrangement of lightening arresster on two pole/four pole structure as per recommendations of manufactures.
2
-
-
... More
M&L for Surface excavation n.exc 30 cm deep and averaging 15 cm and geeting out in any type of soil incl cutting and removing grass, vegetation, bushes/shrubs etc from surrounding of 02 Pole/ 4 Pole structure and LT/ HT Panel E/M installations and removing all rubbish and dressing the gravel/soil and spaying the one time herbicide approved brand (Roundup/Noweed) to prevent the further vegetation and all as specified and directed.
500
-
-
... More
Supply and laying the graded coarse aggregate 40mm size for E/M installations of 33KV MRS yard/2/4 pole HT/LT pole structures/surrounding area of RMU including cleaning the vegetation developed and making plane of surfece and all as specified and directed at site.
40
-
-
... More
Material and labour for cutting the branches/trees near the HT OH line upto clearance area 5mtr around OH line by cutting the branches and removing the wastage from site to disposal area and all as specified and direced, Note :-(i) The necessary man power tool and plant , cutting tools and JCB if required for cutting/ prunning of branches is deemed to incl in the rate quoted for the job (ii) Proper shut down will be taken from JE E/M only.
50
-
-
... More
Supply ,fixing and testing in replacement of 12V 150 AH Tubular type maintence free battery complete connected to existing HT VCB Panel of 33/11 KV complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
Preventive maintenance/servicing and testing of power transformer 3.15 MVA of 33/11KV at MRS ABOD Banar, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge. Note:- Quoted rate shall be deemed to be inclusive of following tests:- (a). Magnetic balance test (b). IR Test (c). Open circuit test (d). Short circuit test (e). Transformer oil test (Test shall be carried out at govt approved lab) (i). Water content test (ii). Neutralisation value (total acidity) test.
1
-
-
... More
Preventive maintance /servicng and testing of indoor type distrubution transformer of capacity 1500 KVA at Banar Area, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge.
Note:- Quoted rate shall be deemed to be inclusive of following tests:- (a). Magnetic balance test (b). IR Test (c).WTO/OTI tripping (d).Oil level and leakage (e). Transformer oil test (i). earthing valve check body and netural (ii).Megar/dielectric strength Complete all as specified and directed by EIC.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements