Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date10 Oct 2024
Closing Date31 Oct 2024
Tender Amount₹ 34,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismanting of insulator any type and size any type complete all as specified and as directed.

120

-

-

... More
Dismanting of old unserviceable street lights with brackets any type complete all as specified and as directed.

50

-

-

... More
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 300 sq mm. 3.5 core complete all as specified and as directed.

500

-

-

... More
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 150 sq mm. 3.5 core complete all as specified and as directed.

281

-

-

... More
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 25 sq mm. 4 core complete all as specified and as directed.

400

-

-

... More
Supply, laying & testing cable XLPE insulated, screened ,PVC bendded galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade, of size 16 sq mm. 4 core complete all as specified and as directed.

2200

-

-

... More
M&L for 190 cm dia cable route indicator made of CI plate 8 mm thick with spike to angle iron 25 x 25 x5mm, 40 mm long makred as LT/HT cable jointing on conductor coil plate complete including fixing and excavation in soft/loose/hard/dense soil, PVC embedded block size 300x300x300 mm (1:3:6) type C-1 using 20 mm graded stone aggreggate complete all as specified and as directed.

20

-

-

... More
Boring of holes under road/pavement/hard standing or any other situation by manual mean and including passing GI pipe 80 mm bore and making good both the ends complete all as specified and as directed. . Note : Pipe and cable will be measured and paid separately

36

-

-

... More
Supply and fix in replacement of GI pipe 80 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and as directed.

30

-

-

... More
Supply and fix in replacement of GI pipe 50 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and as directed.

81

-

-

... More
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and as directed.

811

-

-

... More
All as per item No 14 above but depth exceeding 1.5m and not exceeding 3.0m complete all as specified and as directed.

2.7

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed.

474

-

-

... More
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and as directed.

285

-

-

... More
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and as directed. Note : Thickness after punning shall be considered for payment.

227

-

-

... More
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, stays & mass concrete complete all as specified and as directed.

2.7

-

-

... More
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for poles, stays & mass concrete complete all as specified and as directed.

25

-

-

... More
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in pedestal coping of poles etc including weathering, slightly rounded or chamfered angle and necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and as directed.

2.03

-

-

... More
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and as directed.

22440

-

-

... More
Supply, laying & testing PVC insulated, PVC sheathed cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm 3 core, 1100 Volts grade complete all as specified and as directed.

500

-

-

... More
Supply and fix steel tubular swaged poles type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck, Including foundation and coping complete all as specified and as directed.

50

-

-

... More
Supply, install, testing and commisioning of LT panel duly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of CRCA sheet 3.15mm (outdoor type) thick machine pressed with bottom frame made out of angle iron 50mm x 50mm x 6mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 415 Volt AC 3 phase, 4 strip having insulated Copper bus bar 400 Amps from pole with openable double shutter on both sides (rear and front side) with locking arrangment duly pre-wired with suitable size of copper conductor cable fitted with Incoming proper size copper lugs/thimbless and connecting the incoming MCCBs with suitable size strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including the following accesories & all connected items complete all as specified and as directed. FP No1 Incoming (i) MCCB 400 Amps, four pole with fixed thermal magnetic release, 415 V AC supply, having rupturing capacity 36 KA - 01 No (ii) ATS 400 Amps, 415 volts having rupturing capacity 36 KA - 1Nos (v) Indicating lamps set RYB - 01 Set (VI) Digital Amp Meter 0- 400 A with CT - 400/5 Amp, Digital Voltmeter 0- 500 V

1

-

-

... More
S& F in repair on load changeover switch 400 Amp 3 phase 4 pole 415 volt 50 Hz complete all as specified and as directed.

1

-

-

... More
S & F in replacement, new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP67 roadway luminaire 60 watt with heat resistant clear toughened glass,better optics for uniform distribution street/Roadway luminaire, with driver complete fitting with all accessories and following specifications, complete all as specified and as directed :- (a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) Note :- Bracket for fixing and cable for connection shall be measured and paid separately

50

-

-

... More
Supply and fix in replacement Hot moulded (FRP) junction box of size 155 mm x 210 mm x 92 mm for street light pole with locking arrangement with 32 Amps, 4 way heavy duty terminal block suitable connection for three phase incoming cable three phase outgoing cable and single phase connection for light fittings with control MCB SP 2.5 Amps 01 Nos enclosed in thermoplastic box in closed shock proof safe IP 65, weather, vermin proof, dust and water proof complete with two number cable entry gland of standard size with suitable size mild steel clamps of size 25x3mm with nut and bolt to fix on pole complete all as specified and as directed.

50

-

-

... More
S & F of Automatic Street Light Control Switch using Infrared Sensor based Nature Switch for automatic switching of street lights. Nature Switch operation should be based on Natural Lux Level. Required Illuminance level for switching On is = 30 Lux and for switching OFF =10 Lux. The Circuit should be suitable enough to take Thre phase load of 5 KW with 3 nos Contactors, 3 nos incoming MCBs& 3 nos Outgoing MCBs of 16-20 Amps each & circuit wiring (Copper) of min 10 sqmm. complete all as specified and as directed.

3

-

-

... More
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 32 x 6 mm size by means of bolts, nuts check nuts and washers of galvanised iron and 32 x 6 mm dearth lead protection by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR 2010 Part I and connecting to earth test point all as specified or indicated including testing on completion

5

-

-

... More
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6mm galvanized iron strip complete all as specified and as directed.

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.