Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date29 Aug 2018
Closing Date10 Oct 2018
Tender Amount₹ 16,30,778 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 36,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_MES_207067_1Bid Award Id
ViewTender No
CWE SGNR-33 OF 2018-19Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F in replacement of Transformer HT bushes 11 KV with rod assembly of metallic alloy (brass gun metal) of suitable dia and length with nuts , washers, packing, oil sealing bushes for transformer of following capacity complete all as specified and directed by Engineer-in-Charge.
-
-
-
... More
25 KVA to 100 KVA
4
-
-
... More
125 KVA to 250 KVA
4
-
-
... More
300 KVA to 400 KVA
1
-
-
... More
500 KVA to 630 KVA
2
-
-
... More
S&F in replacement of Transformer LT bushes, 440 Volt with rod assembly of metallic alloy (brass gun metal) of suitable dia and length with nuts , washers, packing, oil, sealing bushes for transformer of following capacity complete all as specified and directed by Engineer-in-Charge.
-
-
-
... More
25 KVA to 100 KVA
2
-
-
... More
125 KVA to 250 KVA
2
-
-
... More
300 KVA to 400 KVA
1
-
-
... More
500 KVA to 630 KVA
1
-
-
... More
S&F cork sheet gasket( for top cover) of transformer of any capacity complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
Dehydration and filtration of existing transformer oil for transformer of any capacity using centrifugal plant to eliminate foreign particles and to improve di-electric strength not less than 60 KV for 1 minute in 2.5mm electrode gap as per relevant IS di-electric strength and to bring the acidity within the permissible limit complete all as specified and directed by Engineer - in - Charge.
Note :- Transformer oil required for topping up shall be measured and paid for separately under respective item of BOQ.
5000
-
-
... More
Supply and filling of fresh transformer oil confirming to IS 335 having di electric strength not less than 60 KV in existing transformers installed at different locations complete all as specified and directed by Engineer-in-Charge.
Make : Transol / Power oil / savita
180
-
-
... More
M&L for replacement of breather assly transparent plastic body with top and bottom portion pressed with metalic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size15/20/25 mm dia with suitable reducer/connectors etc as per site requirement/capacity of transformer complete all as specified and directed by Engr-in-Charge. NOTE: Rate quoted shall be deemed to include the cost of modification if any required to fix on existing pipe
5
-
-
... More
Disconnecting the incoming and out going electric cable from both sides of transformer of any make, any capacity and any type including all acessories, from plinth (plinth mounted ) by any means like mechnical pully or crane including loading into road vehicle, transporting from site to workshop for repair & bring back to site after repair, unloading at site including connections, testing and commissioning complete all as directed by Engineer-in-Charge
Note: (i) Spare parts shall be measured and paid separetely (ii) If any damage to transformer/OH line/ cables occur during handling, transportation or during hosting/ lifting the same shall be rectified by the contractor without any extra cost to department.
3
-
-
... More
M&L for replacement of conservator oil inspection glass after opening by unscrewing nuts, bolts and washers and replacement with heat resistant glass of size not exc 75 sqcm and 3mm thick, complete with new cork sheet gusket, nuts, bolts and washers complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Supply, fixing, testing and commissioning in replacement of tap changing gear for transformer of any description and any make complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
M&L for Painting externally body of step down transformer 11/0.433 KV by spray painting of following capacities complete after scratching of old paint , rust etc and applying two coats of synthetic enamelled paint complete all as specified and directed by Engineer-Charge.
-
-
-
... More
25 KVA to 100 KVA
6
-
-
... More
125 KVA to 200 KVA
4
-
-
... More
250 KVA to 315 KVA
4
-
-
... More
400 KVA to 630 KVA
2
-
-
... More
Supply and fixing in replacement of defective Gun Metal stop cock/gate valve 25mm dia and plug fixed to drain pipe of transformer of any capacity including testing against leakage to the entire satisfaction complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Supply and fixing in replacement of transformer temperature gauge 110mm dia heavy duty 0-100 degre centigrade with thermostat built in switch complete all as specified and directed by Engineer-in-Charge
3
-
-
... More
Supply, fixing, testing and commissioning in replacement of air release plugs suitable for existing transformer of any size and any make complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Supply, laying, jointing testing and commissioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade of cross-sectional area 120 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system , laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed by Engineer-in-Charge.
Note : Excavation, earthwork, sand cushioning and brick protection shall be measured and paid seperately under respective items of BOQ.
220
-
-
... More
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed by Engineer-in-Charge.
80
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
34
-
-
... More
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
46
-
-
... More
Supply and fixing un-reinforced precast concrete cable cover class HV, type-1, with peak, size 300mm x 180mm x 40mm laid flat length of cover across the length of cable complete all as specified and directed by Engineer-in-Charge.
1200
-
-
... More
M & L for sand cushioning with dry coarse sand to under ground cable below and around after laying the cable gently punning down complete all as specified and directed by Engineer-in-Charge.
Note : Thickness after punning shall be considered for payment.
20
-
-
... More
Supplying and fixing in replacement cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed by Engr-in-Charge.
Note :Exposed steel surface shall be treated with two coats of aluminium paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer. The quoted rate shall be deemed inclusive of the above provn.
1
-
-
... More
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge.
4
-
-
... More
M & L for PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in copingof poles/struts/stays etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
2
-
-
... More
M&L for Brick work using fly ash modular bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) for making platform resting trasformer/ panel etc complete all as specified and directed by Engineer-in-Charge.
16
-
-
... More
M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement mortar (1:4), finished even and smooth without using extra cement and applying two coats of white wash after preparation of newly plastered surfaces of wall complete all as specified and directed by Engineer-in-Charge.
8
-
-
... More
M & L for HT 11 KV XLPE cable fault finding with the help of fault finding pin point location machine complete all as specified and as directed. (Note :- Fault will be located and measured in 500 meter irrespective of number of fault located) .
10
-
-
... More
M & L for jointing and testing cold shrinkable type, end termination cable jointing kit, outdoor type, suitable for 11KV (E) under ground earthed system 3 core XLPE cable of size 95 Sqmm armoured aluminium conductor including making connections complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
M & L for jointing and testing cold shrinkable type, end termination cable jointing kit, outdoor type, suitable for 11KV (E) under ground earthed system 3 core XLPE cable of size 120 Sqmm armoured aluminium conductor including making connections complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
M & L for jointing and testing cold shrinkable type, indoor termination cable jointing kit, indoor type, suitable for 11KV (E) under ground earthed system 3 core XLPE cable of size 120 Sqmm armoured aluminium conductor including making connections complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
M & L for jointing and testing cold shrinkable type, straight through cable jointing kit, suitable for 11KV (E) under ground earthed system 3 core XLPE cable of size 120 Sqmm armoured aluminium conductor iincluding making connections complete all as specified and directed by Engineer-in-Charge.
3
-
-
... More
M&L for preparation of old painted steel surface of 4/2 pole structure HT/LT street light /HT steel tubular poles 8.5/9.0 mtr long above GL/coping including cross arms, channels, flat iron, clamps in HT/LT OH line by scraping with wire brush and applying one coat of aluminium paint including pole numbering all as specified and directed by Engineer-in-Charge.
40
-
-
... More
M & L for preparation of old painted steel surfaces i.e. installation display boards of any discription over 10 cm width/girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
50
-
-
... More
M&L for preparation of old painted steel surface of 33/11 KV grid bus bar comprising of steel poles, framed and braced uneaven surfaces channels, cross arms all metalic parts complete applying two coats of aluminium paint complete all as specified and directed by Engineer-in-Charge.
50
-
-
... More
M&L for writing letter figures (Block, Roman,Italic or Indian) n. exc 30cm high (per CM height) complete all as specified and directed by Engineer-in-Charge.
100
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 6mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engr-in-charge.
Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement shall be 1 kg for each earth pit cover
2
-
-
... More
M&L for numerical digital over current and earth fault relay operated on 30 VDC/110VAC of any make installed in VCB panel for protection against short circuit and earth fault, testing, commissioning and submitting test report proper format Make : ABB or equivalent in CG, Siemens, Schnieder
1
-
-
... More
M&L for disconecting opening draw out VCB trolly complete from its position after isolating safety from contacts of breakers for inspection, checking and reinstalling testing commissioning of same after carry out following repair work and replacement of unserviceable spares complete all as directed and specified and by OEM. (i) Checking of draw out mechanism/arrangement of VCB
(ii) Inspection of isolating contacts and decarburizing the male /female contacts, jaws complete and replacement of worn out contacts if any.
(iii) Checking of alignment with spout and setting of contact gaps.
(iv) Replacement of worn out/defective minor spares parts, lubrication of moving parts of the truck by moly grease.
(v)Checking/setting of master control relay earth fault relay and overload relay
(vi) Replacement of burnout spring charge motor
(vii) Replacement of closing coil 30V DC (viii) Replacement of tripping coil 30V DC
(ix) Replacement of top spout with busbar. (x) Replacement of bottom spout with busbar.
(xi) Replacement of Power pack. (xii) Replacement of push button for open and close, micro switches, indication lamps (xiii) Decarburizing and reinsulation of complete busbar track system complete in all respect.
(xiv) Misc works deemed essential to make VCB in perfectly working order
NOTE : Major spare parts are to be paid separetely under respective item herein after, however minor spare shall be deemed to be included in item rate.
8
-
-
... More
Supply only following spare parts suitable for 30 VDC/110VAC to be incorporated under item no 39 above :-
-
-
-
... More
Replacement of burn out spring charge motor
2
-
-
... More
Replacement of closing coil 30V DC
4
-
-
... More
Replacement of tripping coil 30V DC
2
-
-
... More
Replacement of top spout with busbar 11 KV.
1
-
-
... More
Replacement of bottom spout with busbar 11 KV.
2
-
-
... More
Replacement of power pack
1
-
-
... More
Replacement of push button for open and close
3
-
-
... More
Micro switches
6
-
-
... More
Indication lamps
5
-
-
... More
Selector Switch
6
-
-
... More
M&L for battery charger industrial grade 30 volts DC input 230V AC, 50 Hz, 1Ph, DC output nominal 30V, output current, 6 Amps suitable for battery bank of 30 V DC/65 AH complete including necessary indications and protections viz. Charging current meter charging voltmeter, power ON, input HRC fuse link, over current, short circuit, over charging, over temperature, reverse polarity by means of fuse, controls eg. input ON / OFF, output ON / OFF, DCCDB ON / OFF etc. main cord and plug of suitable length and rating and heavy duty terminal blocks at output complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
M&L lead acid battery bank consisting of heavy duty 2 V DC, 60 AH battries for sub station application to be used for operating controls connected as battery bank of 30 V DC each 2 Volt DC, 60 AH x 15 Battries in series, connected with suitable rating of copper conductor wire battery terminals, float for monitoring of electrolite level, complete placed and mounted in space / wooden / fiber battery mounting stand anti corrosive complete duly connected and tested with battery charger complete all as specified and directed by Engineer-in-Charge (Make : Exide / AMCO / Standard)
2
-
-
... More
M&L for primary and secondry injection testing of existing CTs set of three any type any capacity installed in VCBs located at different sites and providing authentic test results for further necesary action complete all as specified and directed by Engineer-in-Charge
3
-
-
... More
S&F in repairs, current transformer dual ratio of rating 100 / 50 / 5A 33 KV pressure epoxy cast resin complete duly installed commissioned connected and tested at site complete all as specified and directed by Engineer-in-Charge (make : Pragati / Prayag Kappa / Crompton / AE / L&T
2
-
-
... More
S&F in repairs digital voltmeter 144 Sqmm for measuring incoming voltage at VCB operated with potential transformer installed in existing space with minor modification complete all as specified and directed by Engineer-in-Charge (Make : AE / L&T /C&C MECO / IMP / AEI)
6
-
-
... More
S&F in repairs, digital multifunction ammeter CTR 5A, commensurating with existing CTs, 144 Sqmm for measuring current load at VCB operated with installed in existing space with minor modifications complete all as specified and directed by Engineer-in-Charge (AE / L&T /C&C MECO / AEI)
4
-
-
... More
Supply, install, testing and commissioning in replacement of 33 KV outdoor type gang operated air break switch triple pole suitable for horizontal mounting complete with explusion fuses, GI operating rod of suitable length for operation mechanism worked from ground level complete in both OFF and ON position, for current rating upto 400 Amps, each pole consist of galvanized steel base HT insulators as per BSS / ISS non ferrous knife and spriong loaded contracts, arcing horns of adequate section to break magenetizing current of the transformers. All ferrous parts hot dipped galvanized and non ferrous parts heavelly tinned to withstand weather complete all as specified and directed by Engineer-in-Chage (Make : Pactiil (Mumbai) / Universal / BHEL / ELPRO / Jaipuria Brothers)
2
-
-
... More
Supply, install, testing and commissioning in replacement of 11 KV outdoor type gang operated air break switch triple pole suitable for vertical mounting complete with explusion fuses, GI operating rod of suitable length for operation mechanism worked from ground level complete in both OFF and ON position, for current rating upto 200 Amps, each pole consist of galvanized steel base HT insulators as per BSS / ISS non ferrous knife and spriong loaded contracts, arcing horns of adequate section to break magenetizing current of the transformers. All ferrous parts hot dipped galvanized and non ferrous parts heavelly tinned to withstand weather complete all as specified and directed by Engineer-in-Chage (Make : Pactiil (Mumbai) / Universal / BHEL / ELPRO / Jaipuria Brothers)
2
-
-
... More
S&F in replacement drop out fuse unit complete set suitable and including for 11 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning all as specified and directed by Engineer-in-Charge
2
-
-
... More
Supply & Fix in replacement pin type insulator of 11 KV including necessary hardware complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Supply & Fix in replacement disc type insulator ball and socket type, white brown or green for 11 KV including necessary hardware complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
S&F anti climbing device, spikes type fabricated out of MS flat 40mm x 3mm in two havles with 14 Nos., 23cm long, 12mm dia spikes made to shape to suit the cross section of the pole including nuts, bolts and washers and welding including two coats of aluminium paint (under and finishing coat) over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
50
-
-
... More
Supply and Fix danger notice plate of size 25cm x 20cm made out of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps made out of 25mm x 3mm flat iron, nuts bolts and washers of approved size of HT poles / transformers etc. with voltage and danger indicated in Hindi and English complete all as specified and directed by Engineer-in-Chage.
10
-
-
... More
Labour only for laying one layer of bricks / cable protection cover of any size (old bricks reused obtained from item taken out cable here-in-after) for cable protection, laid flat and dry in trenches over the cable, prependicular to the direction of cable complete all as specified and directed by Engineer-in-Charge
800
-
-
... More
Taking out old unserviceable under ground HT XLPE /PVC cable of any size from trenches / wall / roof / road / pipe / pole including taking out of brick layer / cable covers from trenches etc. including serviceable brick / cable cover stack for reuse and relaying the same after detacting the fault complete all as specified and as directed by Engineer-in-Charge (Note : Earth work shall be measured and paid for separately under appropriate item)
200
-
-
... More
Laying only old retrieved sand of any type from excavation of HT cable complete all as specified and directed by Engineer-in-Charge
12
-
-
... More
M&L for GI strip of size 32mm x 6mm as earth continuity conductor or main earthing lead fixed to wall battens or recess or chases or buried in ground or drawn in conduit / pipe or fixed to pole or any other indicated situation for loop earthing etc complete all as specified and directed by Engineer-in-Charge
80
-
-
... More
M&L for 40mm dia GI pipe light grade laid in trenches / fixed to pole / wall for cable protection complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
M&L for 50mm dia GI pipe light grade laid in trenches / fixed to pole / wall for cable protection complete all as specified and directed by Engineer-in-Charge.
18
-
-
... More
M&L for 80mm dia GI pipe light grade laid in trenches / fixed to pole / wall for cable protection complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
M&L for replacement of fire stand post made of angler iron of size 50 x 50 x 6mm and 4' x 8' x 2mm of CGI sheet for roofing of fire post including two coat of synthetic enamel paint over a coat of primer and writing "FIRE" (Hindi & English) complete and necessary arrangement for hanging fire bucket, beater, hook etc. including PCC of 1:2:4 type B1, 20mm for grouting the post complete all as specified and directed by by Engineer-in-Charge. The fire post shall be comprising of the following items :-
(i) Fire bucket 10 Litre Capacity : 04 Nos.
(ii) Fire beather with bamboo handle : 01 No.
(iii) Fire hook with bamboo handle : 01 No.
(iv) Shawl with wooden handle : 01 No.
2
-
-
... More
Supply and fix fire extinguisher rechargeable dry powder (ABC) stored pressure type of 5 Kg capacity including necessary hanging arrangement complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
M&L for replacement of chequered mats for electrical purpose at various sub stations of size 1Mx2Mx19mm thickness ISI marked complete all as specified and directed by Engineer-in-Charge.
3
-
-
... More
M&L for replacement of chequered mats for electrical purpose at various sub stations of size 1Mx2Mx25mm thickness ISI marked complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
S&F cable route indicator made out of precast RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 6mm dia MS bars of semicircular shape 15cm dia 10cm thick duly engraved MES HT cable having RCC pillar of size 10cmx10cmx75cm embedded 45 cm below ground level and 30cm above ground level and painted with two coats of synthetic enamel paint above ground level including necessary excavation and earth work omplete all as specified and directed by Engineer-in-Charge.
90
-
-
... More
M&L for fixing of HT/LT side cable terminal box made out of ISA-40405 angle iron and 2mm thick MS sheet incl removable cover with required holes on flange to fix at body of transformer and removable cover and fixing with new cork sheet gasket with nuts bolts and washers incl a coat of red oxide primer and two coat of synthetic enamel paint omplete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply only 5 to 10mm dia, length exceeding 5 cm & not exceeding 10 cm, MS screw bolt (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and directed by Engineer-in-Charge.
3
-
-
... More
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel & wiremesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engr-in-charge. (Notes :- (i) GI wire upto earth test point/ equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1 metre away from the outer edge of PCC chamber.)
2
-
-
... More
S&F of 10mm dia MS round bar for fixing of chain link fencing with post complete all as specified complete all as specified and directed by Engineer-in-Charge.
200
-
-
... More
S&F chain link fencing galvanised mild steel of mesh 75mm x 75mm size of 3.15mm dia wire complete all as specified and directed by Engineer-in-Charge.
Note:- The weight of chain link fencing shall be measured as per findings of board concured by Accepting Officer.
150
-
-
... More
S&F Mild steel framed work as in grills, cooler stand, grating, railings etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railing, frame work for water tanks and similar work conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge.
200
-
-
... More
M&L for surface excavation not exceeding 30cm deep in hard / dense soil including taking out pabbles cutting of grass roots, bushes if any and filling of lower portion with soil obtained from dressing complete all as specified and directed by Engineer-in-Charge.
300
-
-
... More
M&L for filling of aggregate of gauge 20mm/40mm, graded stone aggregate for loose filling complete all as specified and directed by Engineer-in-Charge.
Note :- Payment shall be made for net compacted qty after making deduction @15% for bulkage/voids. -----------------------------------------------------------------------------------------
Note : A sum of Rs. 38,322.00/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 29 & 30 (Schedule of Credit) of Tender documents
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements