Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Dec 2024
Closing Date29 Jan 2025
Tender Amount₹ 34,90,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per Item no 1.00 here in before but plant 2 X 37.5 = 75 TR Capacity (in working) & 1 x 37.5 = 37.5 TR Capacity (as stand by) installed at BOMB DUMP (WSA - II), Make : Blue Star

7

-

-

... More
All as per Item no 1.00 here in before but plant 2 X 75 = 150 TR Capacity (in working) & 1 x 75 = 75 TR Capacity (as stand by) installed at NEW TECH FLT HANGER, Make : Voltas

7

-

-

... More
All as per Item no 1.00 here in before but plant 2 x 11 TR = 22 TR Capacity (in working) & 1 x 11= 11 TR Capacity (as stand by) installed at TRANSMITTER, Make : Blue Star

7

-

-

... More
All as per Item no 1.00 here in before but plant 3 x 11 TR = 33 TR Capacity (in working) & 1 x 11= 11 TR Capacity (as stand by) installed at SEW-I , Make : Blue Star

7

-

-

... More
All as per Item no 1.00 here in before but plant 2 x 7.5 TR = 15 TR Capacity (in working) & 1 x 7.5 TR = 7.5 TR Capacity (as stand by) Package type unit installed at SEW-II BLDG, Make - Voltas Note :- for Item serial number 1.00 to 1.07 (i) T&P and skilled trade man required and replacement of required parts including cleaning of AC plant. The cost for same is deemed to be included in quoted rate (ii) The defective /nonfuctional parts shall be measured and paid seperately under appropriate items of sch 'A' and fixing rates for new items are deemed to included under these items .

7

-

-

... More
Material and labour for Central AC plant of 2 x 36 = 72 TR capacity (in working) & 1 x 36 = 36 TR capacity (as stand by) installed at BASE OPS by de -scaling and cleaning of tubes of condenser (heat Exchanger) unit of central AC plant including opening and refixing of condensor head in origional position all as required at site for shell and tube condensor unit of Central type AC plant by using proper descaling solution by suitable size of drill rod, wire brush,cleaning by circulating pressure water by pressure pumps till the complete deposits/scale is removed as ordered,replacement of packing gasket, nuts, bolts with washer of both ends of condensor complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
All as per Item no 2.00 here in before but plant 2 x 24= 48 TR capacity (in working) & 1 x 24= 24 TR capacity (as stand by) installed at WWR (WSA -III) complete all as specified and directed.

1

-

-

... More
All as per Item no 2.00 here in before but plant 2 X 37.5 = 75 TR capacity (in working) & 1 x 37.5 = 37.5 TR capacity (as stand by) installed at STATION AUDITORIUM complete all as specified and directed.

1

-

-

... More
All as per Item no 2.00 here in before but plant 2 X 37.5 = 75 TR capacity (in working) & 1 x 37.5 = 37.5 TR capacity (as stand by) installed at BOMB DUMP (WSA - II) complete all as specified and directed.

1

-

-

... More
All as per Item no 2.00 here in before but plant 2 X 75 = 150 TR capacity (in working) & 1 x 75 = 75 TR capacity (as stand by) installed at NEW TECH FLT HANGER complete all as specified and directed.

1

-

-

... More
All as per Item no 2.00 here in before but plant 2 x 11 TR = 22 TR capacity (in working) & 1 x 11= 11 TR capacity (as stand by) installed at TRANSMITTER complete all as specified and directed.

1

-

-

... More
All as per Item no 2.00 here in before but plant 3 x 11 TR = 33 TR capacity (in working) & 1 x 11= 11 TR capacity (as stand by) installed at SEW-I complete all as specified and directed.

1

-

-

... More
All as per Item no 2.00 here in before but Package type AC plant 2 x 7.5 TR = 15 TR capacity (in working) & 1 x 7.5 TR = 7.5 TR capacity (as stand by) installed at SEW-II complete all as specified and directed.

1

-

-

... More
M&L for repairing and servicing of FRP cooling tower 72 TR at BASE OPS and 75 TR at STATION AUDITORIUM & BOMB DUMP (WSA - II) of central type AC plant by dismantaling of cooling tower for removing of top cover and cleaning of PVC fills, choked nozzle, PVC louvers and replacement of rusted nuts,bolts with washer etc and cleaning bottom tank to remove dust and mud sand and painting of damged surface oiling of motor and checking of servicibility of motor including painting the interior and exterior parts of cooling towers with epoxy seal paint as per the manufactures specifications complete all as directed by Engr-in charge Note:- others major spare parts shall be measured separetely as under respective item of " Sch A" as Supply only .

4

-

-

... More
All as per item No 3.00 here in before but Cooling tower of capacity 48 TR complete all as specified and directed at WWR (WSA -III).

2

-

-

... More
All as per item No 3.00 here in before but Cooling tower of capacity 150 TR complete all as specified and directed at NEW TECH FLT.

2

-

-

... More
All as per item No 3.00 here in before but Cooling tower of capacity 22 TR complete all as specified and directed at TRANSMITTER.

2

-

-

... More
All as per item No 3.00 here in before but Cooling tower of capacity 33 TR complete all as specified and directed at SEW-I.

2

-

-

... More
All as per item No 3.00 here in before but Cooling tower of capacity 15 TR package type AC plant complete all as specified and directed at SEW-II.

2

-

-

... More
M& L for dismentling / opening air filter ,nuts bolts,tray for AHU general servicing including cleaning of cooling coil from both sides with coil cleaning solution and brushing suitable for AHU ,correcting tension in belts ,checking and correcting allignment of shaft pulley of motor ,cleaning primary & secondary filter ,blower complete of capacity 8500 to 24000 CFM AHU complete all as specified and directed by Engr in Charge. Note:- others major spare parts shall be measured separetely as under respective item of " Sch A" as Supply only .

20

-

-

... More
M& L for dismentling / opening of top cover of Hot water generator of Capacity 30 to 42 KW and cleaning ,servicing of element ,storage tank etc and refixing and testing for desired temperature complete all as specified and directed by Engr-in Charge. Note:- others major spare parts shall be measured separetely as under respective item of " Sch A" as Supply only .

7

-

-

... More
Supply only the following item of AC Plant mentioned here in before to fixed under item serial number 01 to 05 complete all as specified and directed.

-

-

-

... More
Temperature sensor for chiller machine of Blue star/ Voltas all as per sample

3

-

-

... More
Water flow switch of model HFS -25 or as per existing sample. Make : Synergy, Honywell or equivalent .

3

-

-

... More
LP/HP control switch as per sample

3

-

-

... More
Filter drier

3

-

-

... More
Safty Valve for condensor 350 PSI to 550 PSI . Make – SPORLAN/DENFOSS/SANLAN

3

-

-

... More
Microcontroller in replacement of old unserviceable microcontrooler (LCD type) complete with internal PCB controller board/ card along with outer (external )display control unit with inclusive of all control wiring /termination etc complete as a single unit for one machine complete in all respect. Make- Blue star/ Voltas

2

-

-

... More
Thermostatic expansion valve for 15 TR/ 22 TR AC Plant. Make: Honeywell/ Sporlan/Danfoss

2

-

-

... More
Thermostatic expansion valve for 33 TR/ 48 TR AC Plant. Make: Honeywell/ Sporlan/Danfoss

2

-

-

... More
Thermostatic expansion valve for 72 TR/ 75 TR AC Plant. Make: Honeywell/ Sporlan/Danfoss

2

-

-

... More
Air damper for AHU duct as per existing sample. Make : CONIAR or equivalent.

6

-

-

... More
Copper tube thermostat probe of suitable size with sensor

2

-

-

... More
Freon gas pressure gauge of 4''dial ,0 to 14 kgs rating , Make : Fiebig / ACCEL / GURU / WIKA / MAHAVEER

10

-

-

... More
Temperature gauge (Thermometer) suitable for measuring range 0 - 50 degree C . Make : Japsine /GURU

10

-

-

... More
V fan belt for Blower motot of various capacities, Model A-28/A-32 or as per sample Make : Fenner / Hilton/DUNLOP or equivalent

12

-

-

... More
PVC nozzle of size 2 to 3 inch suitable for fixing in cooling tower

12

-

-

... More
PVC filling blocks of size 600mmx300mmx150mm. Make: - MIHIR/SUVIDHA/ AVIRATS

50

-

-

... More
Micro Vee filter having dust filteration capacity 95 % efficiency down to 5 microns with necessary fittings to be fitted in AHU of size 600X600 mm.

10

-

-

... More
Pre filter having dust filteration capacity 90% effiecincy down to 10 micron synthetic non woven ,fire retardant type with aluminium &HDPE mesh of size 600X600 mm

12

-

-

... More
New superior quality canvas including stitching as per existing at site with inspection strip etc

3

-

-

... More
Heating Element of capacity 3/4 KW. Make :- DASSPASS/RECOLD

1

-

-

... More
Heating Element of capacity 5/6 KW. Make :- DASSPASS/RECOLD

1

-

-

... More
Heating Element of capacity 7/8 KW. Make :- DASSPASS/RECOLD

1

-

-

... More
Display unit with sensor for hot water generator with facility auto on/off at set temperature

2

-

-

... More
Refrigerant gas (R407 ) Make : MACRON/FLORON

500

-

-

... More
Cooling tower fan blade assembly for 1.5 HP CT motor. Make: Delta/ Global/Mihir

1

-

-

... More
Cooling tower fan blade assembly for 3 HP CT motor. Make: Delta/ Global/Mihir

1

-

-

... More
Supply & fix in repair of water cooled Scroll chiller , Shell and Tube -DX type of capacity 78 TR suitable for operating with 06 nos 12.5 TR hermetically sealed compressor (Danfos make). Water flow rate 200 Usgpm , water nozzle size 125 mm (nominal bore) designed for water inlet temp 12 C and water outlet temperature 7 C. Existing make- Voltas model ACWCDS078DPMN3X2. Note: Old retrived chiller shall be deposited in MES Store yard.Cost of dismantling and depositing it to MES Store is incluided in quoted rate.

1

-

-

... More
Supply & fix in repair of Shell and Tube type condenser suitable for capacity 26 TR suitable for operating with 02 nos 12.5 TR hermetically sealed compressor (Danfos make). Water flow rate 244 Usgpm , water nozzle size 50 mm (nominal bore) designed for water inlet temp 12 C and water outlet temperature 7 C. Existing make- Voltas model ACWCDS078DPMN3X2. Note: Old retrived condenser shall be deposited in MES Store yard.Cost of dismantling and depositing it to MES Store is incluided in quoted rate.

3

-

-

... More
M&L for finding out the leakage and pressure test of the condensor and cooling coil of 72/75/150 TR capacity AC plant and dismanteling the same for repair the leakage point by dehydration,brazing / soldering including taking down /refixing the unit and testing the AC unit complete all as specified and directed by Engr-in-charge. Note : Cost of T&P and nitrogen gas is deemed to be included in the unit rate quoted.

4

-

-

... More
M&L for finding out the leakage and pressure test of the condensor and cooling coil of 15/22/33/48 TR capacity AC plant and dismanteling the same for repair the leakage point by dehydration,brazing / soldering including taking down /refixing the unit and testing the AC unit complete all as specified and directed by Engr-in-charge. Note : Cost of T&P and nitrogen gas is deemed to be included in the unit rate quoted.

4

-

-

... More
All as per item no 10.00 here in before but for capacity 12.5 TR and charging of regrigerant gas (R-407) & testing complete all as specified and directed . (Make- Model SZ185S4RC of make EmersionCopeland or equivalent make and model of KCL/Emersion/Danfoss

5

-

-

... More
Supply & fix in repair of supply air diffuser of powder coated alumunium but without volume control damper as per specification complete all as specified and directed by EIC

3

-

-

... More
Supply & fix in repair of return air diffuser of powder coated alumunium with aluminium volume control damper as per specification complete all as specified and directed by EIC

2

-

-

... More
Dismantling and taking out monoblock Pumping set of capacity 10 HP for repair/ rewinding of motor and refitting after repair.

4

-

-

... More
Dismantling and taking out monoblock Pumping set of capacity 5HP /7.5 HP for repair/ rewinding of motor and refitting after repair.

6

-

-

... More
Dismantling and taking out Electric motor from cooling tower of capacity 3 HP for repair /rewinding of motor and refitting after repair.

3

-

-

... More
Supply only the following item of pumping set/Motor mentioned here in before to fixed under Item serial No. 12.00 to 14.00 complete all as specified and directed.

-

-

-

... More
Ball bearing suitable for 7.5/10 HP pumping set

3

-

-

... More
Ball bearing suitable for 3/5 HP pumping set

3

-

-

... More
GM Bush suitable for 7.5/10 HP pumping set

2

-

-

... More
GM Bush suitable for 3/5 HP pumping set

2

-

-

... More
S/S shaft suitable for 7.5/10 HP pumping set

2

-

-

... More
S/S shaft suitable for 3/5 HP pumping set

2

-

-

... More
M S Coupling suitable for 7.5/10 HP pumping set

2

-

-

... More
M S Coupling suitable for 5 HP pumping set

2

-

-

... More
Mechanical seal

5

-

-

... More
Rubber bush & nuts bolts of coupling

24

-

-

... More
Rewinding of motor with super enamelled copper wire of existing gauge of cap 2/3 HP

3

-

-

... More
All as per item no. 16.11 but capacity 5 HP

2

-

-

... More
All as per item no.16.11 but capacity 7.5 HP

4

-

-

... More
All as per item no.16.11 but capacity 10 HP

4

-

-

... More
Repair of electric panel by checking defects including required insulation tape ,copper wire of 1.5/2.5 sqmm with replacement of defective items making serviceable condition. Note - Defective items to be measured and paid seperately under "Sch A" as Supply only:-

4

-

-

... More
Supply only the following item of AC Plant electric panel mentioned here in before to fixed under item sr No 17.00 complete all as specified and directed.

-

-

-

... More
Contactor of MNX 12 type, three pole power contactor with 01 NO + 01 NC auxiliary contacts for AC Circuit with AC coil voltage 220 grade, 50 Hz having current rating (AC3) of 12 Amps, 50 Cycle . Make : L&T or equivalent of Siemens / Control & switch gear.

6

-

-

... More
Contactor MNX-18 with auxiliary contacts 1NO + 1NC having current rating (AC3) 18 Amps Make : L&T or equivalent of Siemens / Control & switch gear.

4

-

-

... More
Contactor MNX-25 with auxiliary contacts 1NO + 1NC having current rating (AC3) 25 Amps Make : L&T or equivalent of Siemens / Control & switch gear.

4

-

-

... More
Contactor MNX-32 with auxiliary contacts 1NO + 1NC having current rating (AC3) 32 Amps Make : L&T or equivalent of Siemens / Control & switch gear.

4

-

-

... More
MO-12 contactor with auxiliary contacts 2NO + 2NC having current rating (AC3) 12 Amps Make : L&T or equivalent of Siemens / Control & switch gear.

4

-

-

... More
Thermal over load relay of various ranges from 9 Amps to 42 Amps .Make : L&T / BCH or equivalent.

6

-

-

... More
Single phase preventer, auxiliary volts 415 volts, Make- Minilec, L&T or equivalent

8

-

-

... More
Electronic timer suitable for range 3-30 Seconds . Make : L&T / Havells or equivalent

6

-

-

... More
MCCB, 160 Amps, 4 Pole, 415 Volts having breaking capacity Icu = ICS 100% = 36KA with adjustable thermal setting alongwith SS enclosure including mounting arrangement on panel complete all as specified & directed. Make :Legrand /L&T/Control & Switch gear

2

-

-

... More
All as per Item No 18.09 here-in-before but for capacity 250 Amp 4 pole 36 KA

1

-

-

... More
All as per Item No 18.09 here-in-before but for capacity 100 Amp 4 pole 16 KA

1

-

-

... More
All as per Item No 18.09 here-in-before but for capacity 63 Amp 4 pole 16 KA

1

-

-

... More
All as per Item No 18.09 here-in-before but for capacity 125 Amp 3 pole 16 KA

1

-

-

... More
All as per Item No 18.09 here-in-before but for capacity 100 Amp 3 pole 16 KA

1

-

-

... More
MCB isolator 40 Amps, 3 Pole, 415 Volts 50 HZ, 10 KA breaking capacity complete all as directed.Make :Legrand /L&T/Control & Switch gear

4

-

-

... More
All as per item no. 18.15 here in before but MCB TPN 32/40 amps

4

-

-

... More
All as per item no.18.15 here in before but MCB TPN 63 amps

4

-

-

... More
Amp meter 0-40 / 50 / 60 /100 Amps, 96mm x 96mm, digital type with inbuilt selectorswitch,auxiliary supply 230 V complete all as specified & directed . Make : AE/ L&T/Rishab/Meco/Enercon.

4

-

-

... More
Volt meter 0-500 Volts, 96mm x 96mm, digital type with inbuilt selectorswitch,auxiliary supply 230 V complete all as specified & directed . Make : AE/ L&T/Rishab/Meco/Enercon.

2

-

-

... More
Push Button Red/Green complete all as specified and approved by Engineer-in-Charge.

6

-

-

... More
LED phase indicator Red/Yellow/Blue complete all as specified and approved by Engineer-in-Charge.

6

-

-

... More
M&L for inter connection control wiring with appropriate copper coductor multicore cable in conduit pipe , checking & connection to condensor pump ,chiller ,cooling tower ,AHU ,including contactors with NO/NC with required accessories complete checking of main panel of ac plant for safe operation of AC plant all as specified and directed.

6

-

-

... More
M&L for Taking up or down cast iron butterfly valve of any description and supplying, fixing and testing new butterfly valve of 100 mm bore in existing pipe line after necessary cleaning etc. complete all as specified and directed :- (Make:- Castle/Zoloto/ Sant/Venus/Advance/Audco)

2

-

-

... More
All as per Item No 21 here-in-before but for size of 80 mm bore

2

-

-

... More
All as per Item No 21 here-in-before but for size of 65 mm bore

2

-

-

... More
All as per Item No 21 here-in-before but for size of 50 mm bore

2

-

-

... More
M&L for Disconnecting and taking out existing unserviceable strip heater of any description and in any position and Supply, fixing and connecting strip heater , 230 volts fin type complete all as specified and directed Make : Daspas or equivalent make as approved by the GE.

4

-

-

... More
M&L synthetic electrical insulating rubber mat of size (2 mtr X1 mtr X3mm ) tested for LT Voltage1100 Volts complete all as specified and directed by Engr-in - Charge

2

-

-

... More
Dismanteling of old broken GI sheet cladding over the duct outside the building and M&L for 26 gauge Alumunium sheet cladding complete over the duct outside the building complete all as specified and directed by engr in charge

30

-

-

... More
Dismentelling of old broken plaster insulation and M &L for External thermal insulation to supply and return airduct laid outside the conditioned space/ room with Closed Cell Class O Nitrile Rubber Elastomeric Insulation of 19 mm thick Density 40 - 55 Kg/m3, Thermal Conductivity of 0.037 W/mk at 200 Celcius Mean Temp. and μ≥7000 (without any additional vapour barrier) and with Factory Laminated aluminium foil of minimum 60 microns thickness to be applied on Ducts using manufacturer's recommended Rubber based Adhesive in a blend of solvents complete and finally finished with 26 gauge aluminium sheet complete to make it wheather proof all as specified in particular specification

45

-

-

... More
Material and labour for 100 mm dia chilled and hot water pipe line insulation of fire retardant quality expanded polystyrene moulded pipe section 50mm thickness and density not less trhan 20 kg/cum covered with layer of 120 gm/sqm polythene sheet (as vapour barrier) duly reinforced with 26 gauge chicken wire mesh with buffing of all joints and tied town with GI lacing wire and finally finished with cement mortar of 1:3 of 12mm thick if laid in ground of air outside the building complete with all accessories comprising contorl valves like butterfly valves,balancing valves, Y- strainers, non return valves, pressure gauges, needle valves, themometers, water flow switches, suitable EPDM bellwos etc including excavation, refilling making good the excavated surface wherever reqired at site . Note : All fittings and other connected items to be measured as unit lengths

100

-

-

... More
All as per Item No 29 here-in-before but for 80 mm dia pipe

120

-

-

... More
All as per Item No 29 here-in-before but for 65 mm dia pipe

100

-

-

... More
All as per Item No 29 here-in-before but for 50 mm dia pipe

100

-

-

... More
Supply & fix of Electronic digital Hygrometer thermometer one at plant room and another tepmerature and humidity sensor at conditioned room connected through wire or communication medium (range 100 mtr minimum) to display inside and outside temperature in celcius and humidity complete all as specified & directed.Make - amicisense or Equivalent

4

-

-

... More
S&F in repair of existing cooling tower motor with fan blade complete of capacity 3 hp ,3 Phase copper wound complete same as existing on site complete all as specified and directed by EIC.

1

-

-

... More
S&F in repair of existing monoblock pump of capacity 0.25 hp ,single Phase copper wound complete same as existing on site complete all as specified and directed by EIC.

2

-

-

... More
S&F in repair of existing cooling tower motor with fan blade complete of capacity 1.5 hp ,3 Phase copper wound complete same as existing on site complete all as specified and directed by EIC.

2

-

-

... More
Supply,installation and commissioning of HDPE Water storage tank (cylindrical vertical with closed top) of size 2000 Ltr. complete with air vent and drain connection & overflow, make up connection with float valve complete. .

1

-

-

... More
S&F in repair PVC insulated 1100 volt grade 4 core 4 sqmm heavy duty unarmoured multistranded aluminium coductor laid through suitable saddle complete all as specified

50

-

-

... More
S&F in repair PVC insulated 1100 volt grade 4 core 6 sqmm heavy duty unarmoured multistranded aluminium coductor laid through suitable saddle complete all as specified

50

-

-

... More
S&F in repair XLPE insulated 1100 volt grade 4 core 10 sqmm heavy duty unarmoured multistranded coductor laid through suitable saddle complete all as specified

50

-

-

... More
S&F in repair electronic fire damper 3 phase motor complete with electronic smoke/ fire sensor including electrically operated actuator complete all as specified and directed

1

-

-

... More
S & F digital temperature meter with Red display including temperature sensing probe of suitable size complete all as specified

5

-

-

... More
S & F digital hygrometer with Red display including humidity sensing probe of suitable size complete all as specified

5

-

-

... More
Supply, Install, testing in repair of 3 Way Mixing Valve modulating proportional linear type motorised mixing valve having manual over ride facility with proportional thermostat and wiring with 1.5 sq mm copper conductor multi core armoured cable, 3 way valve suitable size required at site in AHU including actuator of suitable size complete with transformer etc including Electrically controlled /operated control such as humidistat ( to control humidity) and stand alone micro controller based LCD proportionate temperature controller (to control 3 way modulating mixing valve) along with all equipment and accessories including 230V/24 V class 2 transformer complete all asspecified and directed

1

-

-

... More
M&L for fixing of 25 mm gun metal ,globe or gate valve with Iron wheel head screwed both end for Iron pipe complete all as directed by EIC

5

-

-

... More
S&F in repair the 100 mm dia Cast Iron Y Stainer valve of following capacity and Make-Castle/Advance/Audco

1

-

-

... More
All as per Item No 46 here-in-before but for 80 mm dia.

1

-

-

... More
All as per Item No 46 here-in-before but for 65 mm dia.

1

-

-

... More
All as per Item No 46 here-in-before but for 50 mm dia.

1

-

-

... More
Taking down old rusted/ coroded condensor pipe by cutting welding and Supply, fixing ,laying, testing and commissioning of M S Pipes class 'C' confirming to IS : 1239/3589 heavy grade of size 100 mm bore with all fittings laid in floors or fixed to walls and ceilings etc of sizes for condenser water pipes line with complete fittings such as bends, tees, elbows, reducers, flanges, anchor, fasterners, thrust blocks, wooden blocks, special fittings, suspension hangers with suitable supports etc. including painting with synthetic enamel paint with approved colour code complete all as specified and directed. Make :-TATA/Jindal/Prakash

8

-

-

... More
All as per Ser item No 50 but size 80 mm dia.

8

-

-

... More
All as per Ser item No 50 but size 65 mm dia.

6

-

-

... More
All as per Ser item No 50 but size 50 mm dia.

6

-

-

... More
All as per Ser item No 50 but size 40 mm dia.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.