Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,15,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689844_1Tender No
84278/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Laying only old stone patti getting out by all as directed by engr in charge
50
-
-
... More
M/L for Tibba sand for cushioning with layers of sand 8 cm before laying of cable & 15 cm after laying of cable (total 23 cm ) in trenches, duly punning to a thickness of 18 cm for cable protection complete all as directed and specified. Note:- Thickness after punning shall be measured for payment.
470
-
-
... More
Taking out UG LT cable of any size/any core including stone patti directed by engr in charge
7300
-
-
... More
Supply ,laying, test and commissioning in repair of LT UG ,XLPE insulated, heavy duty, 1100V grade of electric cable size 95 Sqmm 3.5 core with aluminium conductor ,served with an inner sheathing of PVC tape armoured eith galvanized steel wire or tape and overall PVC sheathed,laid in trench or passing through pipe, making all connection with and including provision of necessary glands ,lugs,bushing etc as required complete all as specified and directed by Engineer-in -Charge of following size:-Note: Earthwork excavation sand cushioning ,Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items.
800
-
-
... More
(a) All as above item no 7 but size 35 Sqmm 3.5core
1000
-
-
... More
(b) All as above item no 7 but size 25 Sqmm 4core
1500
-
-
... More
(c) All as above item no 7 but size 16 Sqmm 4core
2000
-
-
... More
(d) All as above item no 7 but size 10 Sqmm 4core
1000
-
-
... More
Relaying of old retrieved servicable LT UG cable of any size /any core all as directed by Engr -in- charge
1000
-
-
... More
S & F Steel in replacement of tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) and including pole number marking with stencile cutting and one coat of red oxide primer and two coat of aluminium paint over a pole including dismantlaing/taking out existing PCC/Steel tubular pole and making surface good complete all as specified and directed by Engr -in-Charge.
50
-
-
... More
M&L for plain cement concrete (1:4:8) type D-2 using 40mm grade stone aggregate in foundation of pole/struts etc including necessary form work all as specified and directed by Engr-in-Charge.
3.2
-
-
... More
M&L for plain cement concrete (1:3:6) type C-2 using 40mm grade stone aggregate in foundation of stay assembly/pole including necessary form work all as specified and directed by Engr-in-Charge.
32
-
-
... More
M&L for plain cement concrete (1:2:4) type B-1 using 20mm grade stone aggregate for couping/encasing around of pole including necessary form work finished and smooth without using extra cement all as specified and directed by Engr-in-Charge.
3
-
-
... More
Taking down Unservicable street light/ flood light/ solar light/post top lantern fitting of any size /type/capacity any Watt from height of pole/walls/ for repair work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as specified.
Note :- (a) Spares like LED Driver,surge protector ,service wire etc. shall be measured and paid as separetely under relavant items of schedule'A' (b) Necessary tools like mobile ladder & other T&P required etc shall be arranged by the contractor without any extra cost.
(c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts, cirle clips , clamps etc required if any at site.
420
-
-
... More
Supply and fix in replacement of electronic driver for LED light fitting, LED out put power 30 watt, input voltage range : 170 - 300 volt AC , out put voltage DC as per make/ model range: 24 volt to 110 volt, make as per site requirement complete all as specified.
100
-
-
... More
All as per item No 18 above but capacity 45 watt
100
-
-
... More
All as per item No 19above but capacity 60 watt
100
-
-
... More
All as per item No 19 above but capacity 70 watt
50
-
-
... More
All as per item No 19 above but capacity 90 watt
50
-
-
... More
All as per item No 19 above but capacity 200 watt
20
-
-
... More
All as per item No 19 above but capacity 250 watt
20
-
-
... More
Supply and fix in replacement Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified.
50
-
-
... More
Supply & fix in replacement & including taking down of existing Led Street Light Of Capacity 45 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 110 Lumens/Watt, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Complete all as per model no Cat No crompton CRP-409-45-57-SL-GL-NSG or Equivalent in Appx . The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. all as specified and directed by Engr-in-Charge.
60
-
-
... More
Supply & fix in replacement & including taking down of existing Led Street Light Of Capacity 60 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 110 Lumens/Watt with toughend glass , Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Complete all as per crompton cat No TRP-409-60-57-SL-GL-NSG, or Equivalent. TheManufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. all as specified and directed by Engr-in-Charge.
60
-
-
... More
Supply & fix in replacement & including taking down of existing Led Street Light Of Capacity 90 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 110 Lumens/Watt with toughend glass , Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Complete. all as cat No TRP-411-90-57-SL-GL-NSG or Equivalent. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. all as specified and directed by Engr-in-Charge.
90
-
-
... More
Supply and fixing in replacement & including taking down of PVC insulated, sheathed weather proof, copper conductor of size 1.5 sqmm, 3 core complete all as specified.and directed by Engr in charge
500
-
-
... More
Supply and fixing in replacement including taking down of PVC insulated, sheathed weather proof, aluminium conductor of size 6 sqmm, 2 core complete all as specified.and directed by Engr in charge
800
-
-
... More
M&L in replacement & including taking down of PVC conduit 20 mm, heavy duty rigid non metallic including of all tee, bends, elbows ,MS clamps suiable for steel tubular /pcc pole etc complete all as specified.and directed by Engr in charge
500
-
-
... More
Supply & fix in replacement & including taking down of 40 mm bore GI tubing light grade in trenches or on pole for cable protection complete all as specified and as directed.and directed by Engr in charge
150
-
-
... More
Supply & fix in replacement & including taking down of 80 mm bore GI tubing medium grade in trenches or on pole for cable protection complete all as specified and as directed.and directed by Engr in charge
50
-
-
... More
Supply and Fixing in replacement & including taking down of pole mounted junction box of outer size 300x200x120mm made out of FRP body (hot mulded type) with IP-66 protection and locking with screws alongwith 6-32 Amp rating MCB SP-01 No, up to 50 Amp rated 4 pole connector suitable to insert the cable size up to 25 sqmm x 4 core -02 No and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cables and complete all as specified.and directed by Engr in charge
370
-
-
... More
S&F in replacement & including taking down of existing , galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings all as directed by Engr-in-Charge.
80
-
-
... More
S & F in replacement & including taking down of existing two way galvanised iron bracket 0f medium grade pipe 40mm bore ,length 1.2 m bend to be required shape with ms clamps ,nut and bolts ,washer,etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings on 9/11 steel tubular pole all as directed by Engr-in-Charge.
50
-
-
... More
Supply & fix in replacement & including taking down of existing MCB, single pole, 16-32 Amp, 240 Volts, 'C' Curve 10KA Complete all as specifed and directed by Eng-in-Charge.
30
-
-
... More
Supply & fix in replacement & including taking down of existing of MCB, SPN, 32 Amp, 240 Volts, 'C' Curve 10KA Complete all as specifed and directed by Eng-in-Charge.
20
-
-
... More
Supply & fix in replacement & including taking down of existing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB/ Panel box/ feeder piller box complete with connection testing and commissioning.MCB, TPN 63 Amp, Complete all as specifed and directed by Engr-in-Charge.
10
-
-
... More
Supply & fix in replacement & including taking down of existing MCCB 415V, 3 phase 50 HZ 4 pole 100 Amps breaking capacity 16 KA (Ics = 100% Icu) with connection link on LT panel /fedder piller Complete all as specifed and directed by Eng-in-Charge
2
-
-
... More
Supply & fix in replacement & including taking down of existing MCCB 415V, 3 phase 50 HZ 4 pole 125 Amps breaking capacity 16 KA (Ics = 100% Icu). with connection link on LT panel /fedder piller Complete all as specifed and directed by Eng-in-Charge
2
-
-
... More
Supply & fix in replacement & including taking down of existing MCCB 415V, 3 phase 50 HZ 4 pole 160 Amps breaking capacity 36 KA (Ics = 100% Icu). with connection link on LT panel /fedder piller Complete all as specifed and directed by Eng-in-Charge
2
-
-
... More
Supply & fix in replacement & including taking down of MCCB 415V, 3 phase 50 HZ 4 pole 200 Amps breaking capacity 36 KA (Ics = 100% Icu). with connection link on LT panel /fedder piller Complete all as specifed and directed by Eng-in-Charge
2
-
-
... More
Supply & fix in replacement & including taking down of existing MCCB 415V, 3 phase 50 HZ 4 pole 250 Amps breaking capacity 36 KA (Ics = 100% Icu). with connection link on LT panel /fedder piller Complete all as specifed and directed by Eng-in-Charge
2
-
-
... More
Material and labour for straight through in replacement & including taking down of existing (Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 10/95 SQmm including dismantling the old burnt cable joint termination Complete all as specifed and directed by Eng-in-Charge..
10
-
-
... More
Material and labour for preparation of old painted surface of LT Steel tubular pole (height up to 11 mtr )of any length by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing /clamps /brackets /nut and bolts support on poles and writing of identification Nos with proper stencil cut etc as per directions by Engr-in-Charge.
610
-
-
... More
Material and labour for preparation of old painted surface of LT PCC pole of any length by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing /clamps /brackets /nut and bolts support on poles and writing of identification Nos with proper stencil cut etc as per directions by Engr-in-Charge.
548
-
-
... More
Labour only for making serviceable street/security lights/solar light unserviceable placed at pole by disconnection / Isolating power supply either from pole junction box or by disconnecting overhead conductor and carrying out de-carbonization / de-sulphation at connection points with overhead conductor / light fitting / junction box terminal including replacement connection wire complete all as specified Note : - Cable shall be measured and paid seprately.
450
-
-
... More
S&F in replacement & including taking down of existing Nature switch( using infrared sensor technology ) based automatic street light control panel replacement & including taking down of . The panel should be enough to take three phase load of 25 kw.Nature switch operation should be based on natural light luxes. required illuminance level switching ON is =60 and for Switching OFF =10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable 3 phase load of 25 KW with 3 nos contractor ,3 nos Incoming MCBs of 63 Amps and outgoing MCBs of 63 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof ,Electric shock proof ,Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor Manual or Auto operation . complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
S&F replacement & including taking down of existing Nature switch( using infrared sensor technology ) based automatic street light control panel. The panel should be enough to take three phase load of 12-18 kw.Nature switch operation should be based on natural light luxes. required illuminance level switching ON is =60 and for Switching OFF =10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable 3 phase load of 25 KW with 3 nos contractor ,3 nos Incoming MCBs of 63 Amps and outgoing MCBs of 63 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof ,Electric shock proof ,Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor Manual or Auto operation . complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
S&F replacement & including taking down of existing Nature switch( using infrared sensor technology ) based automatic street light control panel. The panel should be enough to take three phase load of 5-08 kw.Nature switch operation should be based on natural light luxes. required illuminance level switching ON is =60 and for Switching OFF =10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable 3 phase load of 25 KW with 3 nos contractor ,3 nos Incoming MCBs of 63 Amps and outgoing MCBs of 63 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof ,Electric shock proof ,Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor Manual or Auto operation . complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of complete and matching with the surroundings complete all as specified.
20
-
-
... More
M & L bore earthing, including taking down of existing bore earthing, not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground levl connected to galvanized iron strip 32 x 6 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed.
4
-
-
... More
Supply & fix in replacement & including taking down of existing Retro Reflective Tape 3 inch width red and yellow colour sutiable for steel tubular pole and RCC Pole complete all as specified and directed by Engr -in- Charge
100
-
-
... More
Taking down of old existing , Supply & fix ,installation ,testing,and commissioning LT Feeder pillar/Panel board cubical type outdoor conforming to IS 8623 Part 1 1993 ,factory fabricated out of 3.15 mm thick CRCA sheet & suitable size to accommodate all acceessories / fitting , compartmentalized in construction to accomodate incoming and outgoing ,MCCB, MCB and TPN Aluminium Bus bar of rating not less 1.5 times the rated capacity of incomer MCCB/ACB and outdoor feeder. The TPN bud bar shall insulated with color coded heat shrinkable sleeve and shall be mounted on DMC/ Epoxy insulators of suitable size through out the length of TPN bus bar. The incoming as well as outgoing MCCBs shall have copper extension link of current carrying cap not lass than 1.5 times the rated capacity of individul feeders. The extension link shall be supported on DMC /Epoxy insulators having provision for termination of incoming and outgoing cables . All extension links / interconnection shall be insulated with heat shrinkable colour code sleeves. The cubical shall have a bottom channel of size 50x50X5 mm and and 45 cm height above the ground level duly fixed with PCC . a detachable predrilled gland plate of thickness not less than 3 mm thick should be used at a bottom for enrty of armoured cable of adequate size with glands. The above panel shall be front and back openable /lockable by the key from both side and shall have louvers and air vent gasket for natural floe of air.XLPE adhesive type gasket shall be used to make the panel weather , dust and vermin proof with IP 65 degree of protection ,complete as specified and consisting the following switchgears and accessories.:- (a) 4 No's alumnium bus bar of rating 400 Amps mounted on heavy duty rubberised/porcelene support two set (Vertically and horizontaly) (b) Incoming MCCB 4 pole ,250 Amp 415 Volts , 36 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -01 No (Ics =100%Icu) (c) Outgoing MCCB 4 pole ,160 Amp 415 Volts , 16 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -01 No (Ics =100%Icu) (d) Outgoing MCCB 4 pole ,100 Amp 415 Volts , 16 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -02 No (Ics =100%Icu)
2
-
-
... More
(e) Digital type Ampere meter 3 phase including CT ratio 100/5 (three Nos of CT ) including selector switch 0-50 Amp-01 No (f) MCB SPN 32 Amp -02Nos (g) Digital type Voltmeter 0-500 with selector switch- 01 No (h) Indicating lamp LED type 230 volts for RYB including all necessuary items set of three -01 No (j) Plateform for the feeder pillar board with PCC (1:2:4) work (k) digital advance microcontroller and real time clock base astronomical timer panel suitable Time switches 415 V three Phase of 40 Amp rating - 01 Nos. (l) Contactor 415 V three Phase of 63 Amp rating - 01 Nos. Note :- All MCCBs to be Ics= 100% Icu Note : (a) Contractor has to arrange his own vehicles along with mounted hydraulic ladder/articulated & telescopic boom lift arrangement for attending the complaint throughout jaisalmer cantt area. (b) Contractor shall depute minimum 2 staff daily to attend and rectify the complaint. if not, Contractor shall have to bear a penalty of Rs 50.00 per complaint or maximum of Rs 500 per day on this account (c) Complaints has to attend and rectify the complaint/defect irrespective of no of trips/Complaints as alloted by Eng-in-Charge. (d) Complaint should be attend in Night also Note : Contractor has to arrange telescopic boom lift for maintenance at height of 15m at his own cost. No extra payment will be paid by department.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%