Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 19,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684327_1Tender No
8621/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Distempering with oil bound washable distemper of approved brand and
manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer.
90
-
-
White washing with lime to give an even shade: New work (three or more coats) complete all as specified and directed by Engineer-in-Charge.
20
-
-
White washing with lime to give an even shade : Old work (one or more coats) complete all as specified and directed by Engineer-in-Charge.
10
-
-
Distempering with 1st quality acrylic distember (Ready mix) having VOC
content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats)
5
-
-
Painting Old steel surfaces with synthetic enamel paint of required shade. Old work (one or more coat) of approved brand and manufacture.
10
-
-
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing
and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in charge.
30
-
-
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
35
-
-
Providing and fixing 15 mm thick false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the existing frame work consisting of T-sections and Lsections suitably fixed according to tile size as per direction of Engineer-in-charge
30
-
-
Dismantling tile work in floors and roofs laid in cement mortar including
stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
95
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm.
30
-
-
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm.
2.5
-
-
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
12.5
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
50
-
-
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
15
-
-
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
15
-
-
Demolishing cement concrete manually/ by mechanical means including
disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix).
1.5
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
20
-
-
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : of area 3 sq. metres and below
7
-
-
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for door, windows, ventilators. External member of the frame, Internal member of the frame, Aluminium snap beading on both side, Angle cleat 38x38x4.8 mm 50 mm long, Aluminium T or L sections - C.P. brass /stainless steel screws 20 mm for cleat angle, Powder coating 50 microns on aluminium sections, Labour for drilling holes, hire charges of drill, electricity charges, carriage of dash hold fastners and sundries complete as per direction of Engineer- in-charge.
95
-
-
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors,windows and ventilators - Hanging style, Meeting style, Top & bottom rail, Lock rail, Glazing plate, Aluminium snap beading, Aluminium angle cleat, Anodised Aluminium butt hinges, C.P. brass /stainless steel screws 20 mm for cleat, for glazing plate @ 15 cm centre to centre in 75 cm length, Chromium plated Brass screws 20 mm, Powder coating 50 microns on aluminium sections, Neoprene/ EPDM rubber gasket in groove of meeting style
Neoprene/EPDM rubber gasket, Skilled Beldar for fixing the shutter including hinges, Labour for making provision for fittings and carriage of screws etc. including sundries all complete as per requirement and the directions of Engineer-in-charge.
35
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
12
-
-
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. (Only weight of grill to be measured for payment).
8
-
-
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
5
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm
12
-
-
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
9.96.1 300x16 mm
4
-
-
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
1
-
-
Providing and fixing aluminium handles, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete as per direction of Engineer- in-charge.
15
-
-
Providing and fixing IS: 12817 marked stainless steel but hinges with stainless screws etc. complete 125x64x1.90mm
12
-
-
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
1
-
-
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing 30mm thick plain PVC door shutters.
11
-
-
Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). 18 mm thick
7.5
-
-
Providing M.S. Piano hinges ISI marked IS: 3818 finished with nickel chromium plating grade 1 as per IS: 1068 and fixing with necessary screws etc., complete. Overall width 35 mm
6
-
-
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
120
-
-
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at
ground level as per direction of Engineer-in-charge
1
-
-
Providing and placing on terrace (at all floor levels) polyethylene water
storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1000
-
-
Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 20 mm diameter.
3
-
-
Dismantling G.I. pipes (internal/external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore
30
-
-
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 20 mm dia nominal bore
20
-
-
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 15 mm dia nominal bore
10
-
-
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 20 mm nominal bore
1
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
2
-
-
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
2
-
-
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia
2
-
-
Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore
2
-
-
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required complete all as specified and directed by Engineer-in-charge.
2
-
-
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
2
-
-
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
2
-
-
Providing and fixing C.P. brass bib cock of approved quality, conforming to IS: 8931: 15 mm nominal bore complete all as specified and directed by Engineer-in-charge.
2
-
-
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore
1
-
-
Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia
2
-
-
Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in charge (payment for providing grooves shall be made separately)
30
-
-
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
30
-
-
Taking down carefully aluminum/copper point wiring (light/fan/ socket/ power) complete including fittings such as switch, socket, ceiling roses light fittings etc and and making good disturbed surface of wall all as specified and directed by Engineer-in-Charge.
43
-
-
Material and labour for point wiring complete with 1.5 sq mm single core multi stranded copper conductor PVC FRLS insulated unsheathed 1100 Volt grade cable in and incl PVC FRLS CONCEALED CONDUIT PIPE (ISI Marked) with all accessories including new pressed steel terminal boxes (sunk in wall ) with 3.00 mm thick plastic laminated sheet top cover or PVC FRLS board including PVC FRLS top cover with 1.50 sq mm insulated unsheathed PVC FRLS multistranded covered copper conductor for common earth and connecting to earth dolly and making good disturbed surface of wall incl matching the colour of wall/ceiling with extisting wall/ceiling colour all as specified and directed by EIC for
-
-
-
(a) One light/ex fan point controlled by one switch one way
18
-
-
(b) One ceiling fan point controlled by one switch one way
2
-
-
(c) One socket out let 5 Amps 5 Pin on same board with other switch
3
-
-
(d) One socket out let 5 Amps 5 pin on independent board
10
-
-
All as per item No 2 here in before but with single core multistranded cable of size 2.5 Sqmm for one 15 Amps socket outlet on independent board and multistanded insulated copper earth continuity conductor of size 2.5 Sq mm complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Supply and fixing modular switch 6 Amps single module one way complete all as specified and as directed by Engineer-in-Charge.
33
-
-
Supply and fixing modular socket 6 Amps 3/5 pin double module complete all as specified and as directed by Engineer-in-Charge.
13
-
-
S&F in repair modular switch 16 Amps single module complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Supply and fixing modular socket 6&16 Amps 5 pin double module complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Supply and fixing moduler Fan step regulator, two module complete complete all as specified and as directed by Engineer-in-Charge.
2
-
-
Supply and fixing Ceiling rose on PVC FRLS board size 65 X 50 mm three terminal complete all as specified and as directed by Engineer-in-Charge.
18
-
-
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps complete all as specified and as directed by Engineer-in-Charge..
2
-
-
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity of 2.0 TR
2
-
-
Supply and fixing LED lights fitting 1x 10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from rose complete.
2
-
-
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from rose complete all as directed by EIC.
7
-
-
Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
4
-
-
M&L for concealed sub main wiring with 2 single core 4 Sqmm copper conductor (Multistandered) in PVC FRLS conduit of suitable size as required, including 4.0 Sqmm copper conductor as earth continuity complete all as directed by EIC.
42
-
-
M&L for concealed sub main wiring with 2 single core 6 Sqmm copper conductor (Multistandered) in PVC FRLS conduit of suitable size as required, including 6.0 Sqmm copper conductor as earth continuity complete all as directed by EIC.
40
-
-
Supplying and fixing 4 way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required complete all as directed by EIC.
1
-
-
Supplying and fixing 8 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required complete all as directed by EIC.
1
-
-
M&L for Making hole for fixing of exhaust fan size 300 mm sweep in kitchen including complete work by making finishing as existing and round complete all as directed by EIC.
2
-
-
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louver complete all as specified and as directed by Engineer-in-Charge.
2
-
-
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor complete all as specified and as directed by Engineer-in-Charge.
2
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required complete all as directed by EIC
16
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of single poles and neutral in the existing MCB DB complete with connections, testing and commissioning etc complete all as specified and as directed by Engineer-in-Charge.
1
-
-
Supplying and fixing 63 amp rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required complete all as specified and as directed by Engineer-in-Charge.
1
-
-
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed by Engineer-in-Charge.
1
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4.0 core
80
-
-
Excavation in trenches in soft/loose soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out including trimming of sides, complete all as specified and as directed by Engineer-in-Charge.
6
-
-
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick,complete all as specified and as directed by Engineer-in-Charge.
5
-
-
Removing of excavated soil not exc. 50 mtr and depositing where directed at level n. exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
1
-
-
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm under ground cables for protection complete all as specified and as directed by Engineer-in-Charge.
165
-
-
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to under ground cable complete all as specified and as directed by Engineer-in-Charge.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%