Military Engineer Services Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 28,200Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_231426_1Bid Award Id
ViewTender No
8822/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L Galvanised iron tubing, 40mm bore light grade, ISI marked, including fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete.
15
-
-
... More
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified.
Note :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
80
-
-
... More
Supply, fixing, installing, testing and commissioning indoor type ceiling mounted shadow less operation theater light (OT Light) micro processor controlled, surgical LED Light suitable for examination, operation & procedure needs in hospital at MH Alwar. This light shall be consist of 2 Domes (Duel Domes). One as main dome and another as setellite dome on a single mount and as per followings :- Cont/-
1
-
-
... More
Cont/- (A) Main Dome ;-
(i) Head size shall be 65 to 70 cm.
(ii) Intensity output shall be 1,60,000 Lux at 1 mt.
(iii) Intensity control in 6 steps (25 to 100 %) 40000 to 160000 Lux
(iv) CRI ≥ 95% Adjustable colour temperture through intuitive control panel 3800 K to 4800 K (v) Light field size 20 cm to 30 cm at 1 mt
(vi) Depth of illumination 85 to 150 cm
(vii) LED Bulb life should be min 50000 hours and bulb should be in single colour (viii) It should be rotating 360 degree at pivot axis and can be stable in any desired position (ix) Should have with sterlizable, autoclavable material, detachable hand grip (x) Should have adjustable focus system (light field size ) can be adjusted from 20 to 30 cm illuminated diameter at 1 mtr
Cont/-
-
-
-
... More
Cont/- (xi) Power input 220 V + 20 V frequency 50 HZ
(xii) It should have all safety standards as appicable and required for Hospitals. CE Certified, FDA Certified, CSA Certified (xiii) There should be low emission and NO UV from the light.
Make : Philips / Luvis / Siemens as approved by GE.
Cont/-
-
-
-
... More
Cont/- (B) Satellite Dome :
(i) Head size shall be 50 cm
(ii) Intensity output shall be 1,20,000 Lux at 1 mt.
(iii) Intensity control in 6 steps (35 to 100 %) 40000 to 120000 Lux
(iv) CRI ≥ 95% Adjustable colour temperture through intuitive control panel 4300 K to 4800 K (v) Light field size 20 cm to 30 cm at 1 mtr
(vi) Depth of illumination 65 to 125 cm
(vii) LED Bulb life should be min 50000 hrs and bulb should be in single colour (viii) It should be rotating 360 degree at pivot axis and can be stable in any desired position (ix) Should have with sterlizable, autoclavable material, detachable hand grip (x) Should have adjustable focus system (light field size ) can be adjusted from 20 to 30 cm illuminated diameter at 1 mtr
(xi) Power input 220 V + 20 V frequency 50 HZ
Cont/-
-
-
-
... More
Cont/- (xii) It should have all safety standards as applicable and required for Hospitals. CE Certified, FDA Certified, CSA Certified (xiii) There should be low emission and NO UV from the light.
Make : Philips / Luvis / Siemens as approved by GE.
(C) Indigenous power : UPS of appropriate rating and should meet ISI Specification Input Voltage : 160 - 260V, Output Voltage : 220-240 Volts, Freq : 50 HZ Consists of inbuilt rechargeble battery backup that should be consealed in UPS and recharge automatically when connected to AC Mains
(D) Documents : to be provided (i) Users manual for OT Lights & UPS
(ii) Service manual for OT Lights & UPS.
(iii) Log Book for routine maintenance and check list.
Cont/-
-
-
-
... More
Cont/- (E) Warranty :
(i) The Contractor should give at least 5 Yrs warranty after commissioning the lights and UPS for all accessoriesand and in any condition circumstances of power supply.
(ii) The Contractor should give written warranty as above from his own as well as from manufacturer / dealer.
(iii) Any defect under Guarantee / Warrantee period shall be attended by technician and shall be rectified with in 24 Hrs of the complaint.
-
-
-
... More
M&L for point wiring complete for Socket 15 amp controlled by one way switch with 4.0 sqmm two run of single core multistranded copper conductor of 1100 volts grade, confirming to IS-694, PVC insulated and unsheathed FRLS cable enclosed in and including PVC casing and capping box type with accessories fixed on surface of walls/ ceiling by means of PVC sleeves /dash thru fasteners with cadimium plated screws all as per IS with wooden box with 3mm thick plastic laminated bakelite (Hylam) sheet top cover for mounting switches ,sockets regulators, bell push etc. including 4.0 sqmm single core multistranded copper conductor with green colour PVC ,FRLS , confirming to IS- 694 ,insulated unsheathed earth continuity conductor to common earth and connecting earth dolly complete all as specified
2
-
-
... More
Supply and fixing switch piano flush type, single pole, one way, 15/16 Amp, 230 Volts.
2
-
-
... More
Supply and fixing socket outlet for 2 in 1, 3 pin 5 & 15 Amp, flush type 240 Volt.
2
-
-
... More
S&F ON LOAD change over switch 415 volt in sheet metal enclosure 4 pole of capacity 63 Amps complete all as specified and directed.
1
-
-
... More
Supply and fixing sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 4 way, 240 volts.
2
-
-
... More
Supply and fixing MCB 32 Amps, single pole & neutral, 240 Volts.
1
-
-
... More
Supply and fixing MCB 6 to 32 Amps, single pole, 240 Volts.
2
-
-
... More
Supply and fixing 2nd class hard wood rectangular block open recessed of size 30x25x5 cm depth with 3mm thick hylum/Bakelite sheet on top grouted with 4 Nos bolts.
1
-
-
... More
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked (IS: 694) cables, drawn through & including suitable size of heavy duty PVC conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed on surfaces of wall/ceiling complete all as specified and directed.
Note:- 02 runs of 6 sqmm size, 01 run of 4 sqmm size cable & conduit with accessories shall be measured as one run length for payment purpose.
30
-
-
... More
M&L for PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in road / hardstanding complete all as specified and directed.
1
-
-
... More
Material and labour earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part I and connection to main switch board or panel and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, (contd....)
2
-
-
... More
(contd....)
PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, 75 mm thick RCC cover 1:2:4 type B-1 shall be provided on CI frame etc complete all as specified & as directed.
Note : PCC chamber shall be constructed at least 1.5 m away from the earth electrode. The pipe for watering shall be provided in slanting manner
-
-
-